<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article
  PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article article-type="research-article" dtd-version="1.1" specific-use="sps-1.9" xml:lang="en" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
	<front>
		<journal-meta>
			<journal-id journal-id-type="publisher-id">dyna</journal-id>
			<journal-title-group>
				<journal-title>DYNA</journal-title>
				<abbrev-journal-title abbrev-type="publisher">Dyna rev.fac.nac.minas</abbrev-journal-title>
			</journal-title-group>
			<issn pub-type="ppub">0012-7353</issn>
			<issn pub-type="epub">2346-2183</issn>
			<publisher>
				<publisher-name>Universidad Nacional de Colombia</publisher-name>
			</publisher>
		</journal-meta>
		<article-meta>
			<article-id pub-id-type="doi">10.15446/dyna.v90n225.104707</article-id>
			<article-categories>
				<subj-group subj-group-type="heading">
					<subject>Article</subject>
				</subj-group>
			</article-categories>
			<title-group>
				<article-title>Rotational inertia-based tuned-mass-damper for controlling force transmission</article-title>
				<trans-title-group xml:lang="es">
					<trans-title>Absorbedor dinámico de vibración sintonizado con inercia rotacional para controlar transmisión de fuerza</trans-title>
				</trans-title-group>
			</title-group>
			<contrib-group>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0002-0180-4874</contrib-id>
					<name>
						<surname>Barredo</surname>
						<given-names>Eduardo</given-names>
					</name>
					<xref ref-type="aff" rid="aff1"><sup>a</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0002-2878-2476</contrib-id>
					<name>
						<surname>Mendoza-Larios</surname>
						<given-names>José Gabriel</given-names>
					</name>
					<xref ref-type="aff" rid="aff2"><sup>b</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0001-7989-6935</contrib-id>
					<name>
						<surname>Mazón-Valadez</surname>
						<given-names>Cuauhtémoc</given-names>
					</name>
					<xref ref-type="aff" rid="aff1"><sup>a</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0001-9777-2119</contrib-id>
					<name>
						<surname>Maldonado-Bravo</surname>
						<given-names>Irving Abdiel</given-names>
					</name>
					<xref ref-type="aff" rid="aff2"><sup>b</sup></xref>
				</contrib>
			</contrib-group>
			<aff id="aff1">
				<label>a</label>
				<institution content-type="original"> Universidad Tecnológica de la Mixteca, Instituto de Ingeniería Industrial y Automotriz, Huajuapan de León, Oaxaca, México, eduardin@mixteco.utm.mx, jgml@mixteco.utm.mx</institution>
				<institution content-type="normalized">Universidad Tecnológica de la Mixteca</institution>
				<institution content-type="orgname">Universidad Tecnológica de la Mixteca</institution>
				<institution content-type="orgdiv1">Instituto de Ingeniería Industrial y Automotriz</institution>
				<addr-line>
					<city>Huajuapan de León</city>
					<state>Oaxaca</state>
				</addr-line>
				<country country="MX">México</country>
				<email>eduardin@mixteco.utm.mx</email>
				<email>jgml@mixteco.utm.mx</email>
			</aff>
			<aff id="aff2">
				<label>b</label>
				<institution content-type="original"> Tecnológico Nacional de México - CENIDET, Cuernavaca, Morelos, México, d17ce022@cenidet.tecnm.mx, d20ce004@cenidet.tecnm.mx</institution>
				<institution content-type="normalized">Universidad Tecnológica de la Mixteca</institution>
				<institution content-type="orgname">Tecnológico Nacional de México - CENIDET</institution>
				<addr-line>
					<city>Cuernavaca</city>
					<state>Morelos</state>
				</addr-line>
				<country country="MX">México</country>
				<email>d17ce022@cenidet.tecnm.mx</email>
			</aff>
			<pub-date date-type="pub" publication-format="electronic">
				<day>15</day>
				<month>02</month>
				<year>2024</year>
			</pub-date>
			<pub-date date-type="collection" publication-format="electronic">
				<season>Jan-Mar</season>
				<year>2023</year>
			</pub-date>
			<volume>90</volume>
			<issue>225</issue>
			<fpage>131</fpage>
			<lpage>139</lpage>
			<history>
				<date date-type="received">
					<day>08</day>
					<month>09</month>
					<year>2022</year>
				</date>
				<date date-type="rev-recd">
					<day>09</day>
					<month>02</month>
					<year>2023</year>
				</date>
				<date date-type="accepted">
					<day>21</day>
					<month>02</month>
					<year>2023</year>
				</date>
			</history>
			<permissions>
				<license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by-nc-nd/4.0/" xml:lang="en">
					<license-p>This is an open-access article distributed under the terms of the Creative Commons Attribution License</license-p>
				</license>
			</permissions>
			<abstract>
				<title>Abstract</title>
				<p>Nowadays, the inerter device has become one of most popular mechanical devices in the vibration absorption field for both stationary and non-stationary mechanical structures. One of the problems commonly reported in the literature is the force transmission control in the foundations that support the machines, which is generally addressed by using either isolators or classic dynamic vibration absorbers (DVAs). However, the mechanical energy dissipation capability of these two solutions is still limited. This work focuses on improving the control performance for the conventional absorber using the inerter’s inertial mass amplification and negative stiffness effects. In order to fairly evaluate the control performance of the DVA based on grounded inerter, the <inline-formula id="e1">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie1.jpg"/>
					</inline-formula> and <inline-formula id="e2">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie2.jpg"/>
					</inline-formula> optimization criteria are proposed. When the dimensionless frequency response function (FRF) of the transmissibility is minimized at the resonant peaks, the <inline-formula id="e3">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie3.jpg"/>
					</inline-formula> criterion reveals an improvement of 29.74% in mitigating harmonic vibration. Finally, the total vibration energy transmitted to the foundation is minimized via <inline-formula id="e4">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie4.jpg"/>
					</inline-formula> criterion that provides an improvement of 33.03%. </p>
			</abstract>
			<trans-abstract xml:lang="es">
				<title>Resumen</title>
				<p>Hoy en día, el inersor se ha convertido en uno de los dispositivos mecánicos más populares en el campo de absorción de vibración tanto en estructuras mecánicas estacionarias como no estacionarias. Uno de los problemas comúnmente reportados en la literatura es el control de transmisión de fuerza en los cimientos que soportan a las maquinas, que generalmente se atacan utilizando ya sea aisladores o absorbedores dinámicos de vibración (DVAs). Sin embargo, la capacidad de disipación de energía mecánica de estas dos soluciones es aún limitada. Este trabajo se centra en mejorar el rendimiento de control del absorbedor convencional utilizando los efectos de amplificación de masa inercial y el de rigidez negativa del inersor. Para evaluar justamente el rendimiento de control del DVA basado en inersor conectado a tierra, se proponen los criterios de optimización <inline-formula id="e5">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie1.jpg"/>
					</inline-formula> y <inline-formula id="e6">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie4.jpg"/>
					</inline-formula>. Cuando se minimiza la función de respuesta en frecuencia adimensional de la transmisibilidad en los puntos resonantes, el criterio <inline-formula id="e7">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie1.jpg"/>
					</inline-formula> revela un mejoramiento del 29.74% de atenuación de vibración. Finalmente, se minimiza la energía total de vibración transmitida a los cimientos a través del criterio <inline-formula id="e8">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie8.jpg"/>
					</inline-formula> que proporciona un mejoramiento del 33.03%.</p>
			</trans-abstract>
			<kwd-group xml:lang="en">
				<title>Keywords:</title>
				<kwd>Inerter</kwd>
				<kwd>control frequencies tuning</kwd>
				<kwd>passive vibration control</kwd>
				<kwd>invariant frequencies</kwd>
				<kwd>ℋ∞ norm</kwd>
				<kwd>ℋ<sub>2</sub> norm</kwd>
			</kwd-group>
			<kwd-group xml:lang="es">
				<title>Palabras clave:</title>
				<kwd>Inersor</kwd>
				<kwd>sintonización de frecuencias de control</kwd>
				<kwd>control pasivo de vibración</kwd>
				<kwd>frecuencias invariantes</kwd>
				<kwd>norma ℋ∞</kwd>
				<kwd>norma ℋ<sub>2</sub></kwd>
			</kwd-group>
			<counts>
				<fig-count count="6"/>
				<table-count count="1"/>
				<equation-count count="32"/>
				<ref-count count="36"/>
				<page-count count="9"/>
			</counts>
		</article-meta>
	</front>
	<body>
		<sec sec-type="intro">
			<title>1. Introduction</title>
			<p>Vibration attenuation is one of the most important and challenging tasks into stationary and non-stationary mechanical structures subjected to the different kinds of environmental loads such as seismic excitation, wind loads, sea waves, vehicular traffic, among other excitation inputs. It is worth mentioning that most of these types of broadband power spectrum excitations are controlled via electronically controlled devices. However, active control techniques demand high power consumption, sophisticated control laws, bulky actuators, and so on. On the other hand, semi-active control can emulate the dynamic behavior of an actively controlled actuator while the threshold or saturation point of the device is not exceeded, demanding a minimal energy consumption. In contrast, passive control is one of the most widely used technologies in structural engineering due to its low implementation cost, it does not require industrial maintenance, and simplicity in the design topology, among other important characteristics. Dynamic vibration absorbers (DVAs) are fully mechanical devices for the passive control, which is mainly composed of a tuned physical mass coupled to the parallel arrangement of a spring with a viscous fluid damper, which was proposed by Ormondroyd and Den Hartog over a hundred years ago <sup>[</sup><xref ref-type="bibr" rid="B1"><sup>1</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B2"><sup>2</sup></xref><sup>]</sup>. Certainly, the vibration mitigation effectiveness of the DVAs strongly depends on both the tuned physical mass and the suspension system’s mechanical energy dissipation capability. To address this drawback, different variant design topologies of the DVA have been proposed, which are: the non-traditional DVA designed by Ren <sup>[</sup><xref ref-type="bibr" rid="B3"><sup>3</sup></xref><sup>]</sup>, Maxweel element-based DVA studied by Nishihara and Anh <sup>[</sup><xref ref-type="bibr" rid="B4"><sup>4</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B5"><sup>5</sup></xref><sup>]</sup>, Kelvin element-based DVA proposed by Kaul <sup>[</sup><xref ref-type="bibr" rid="B6"><sup>6</sup></xref><sup>]</sup>, as well as other layouts. </p>
			<p>When the target is to suppress broadband vibration, the aforementioned devices lack both robust frequency filtering and transient and steady-state vibration mitigation effectiveness. To address with these concerns, the DVA’s performance has been improved by Asami <sup>[</sup><xref ref-type="bibr" rid="B7"><sup>7</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B8"><sup>8</sup></xref><sup>]</sup> through the usage of multiple DVAs connected both in series and in parallel, and the Two-Degree-of-Freedom Tuned Mass Damper (TDOF-TMD) based on the stiff beam that undergoes translational and rotational dynamics which was analyzed by Zuo <sup>[</sup><xref ref-type="bibr" rid="B9"><sup>9</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B10"><sup>10</sup></xref><sup>]</sup>. The engineering applications of these devices are only limited to the installation space, to mention a few: horizontal axis wind turbines <sup>[</sup><xref ref-type="bibr" rid="B11"><sup>11</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B12"><sup>12</sup></xref><sup>]</sup>, machining processes improvement <sup>[13]</sup>, seismic vibration mitigation <sup>[</sup><xref ref-type="bibr" rid="B14"><sup>14</sup></xref><sup>]</sup>, as well as other substantial applications. In view of the vibration attenuation potential of these devices, the technology of multiple DVAs configured in series was hybridized by Barredo et al. <sup>[</sup><xref ref-type="bibr" rid="B15"><sup>15</sup></xref><sup>]</sup> by means of the rotational inertia concept. This passive control technology is well known in the literature as The Inerter, which was proposed by Smith in 2002 <sup>[</sup><xref ref-type="bibr" rid="B16"><sup>16</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B17"><sup>17</sup></xref><sup>]</sup>.</p>
			<p>The inerter is a mechanical device that stores kinetic energy through a flywheel, which has been studied by Chen et al. <sup>[</sup><xref ref-type="bibr" rid="B18"><sup>18</sup></xref><sup>]</sup>. When such a mechanical energy is released, the inerter’s terminals provide reaction forces directly proportional to the product of the inertance value with the acceleration difference value of its terminals. Recently, Ma et al. <sup>[</sup><xref ref-type="bibr" rid="B19"><sup>19</sup></xref><sup>]</sup> reported the three important dynamic characteristics of such a device, which are the following: a) frequency isolation capacity, b) inertial mass improvement and c) negative stiffness effect. It is worth mentioning that, since the invention of the inerter, many different investigations have been conducted on its dynamic performance for both stationary and non-stationary structures, which were reported by Wagg <sup>[</sup><xref ref-type="bibr" rid="B20"><sup>20</sup></xref><sup>]</sup>. Although much research has been performed on the control performance for inerter-based DVAs considering different kinds of excitation sources, the control performance of DVA based on grounded inerter under base excitation has not yet been considered. In fact, it leads to the study of the inerter’s control effectiveness considering the frequency response function (FRF) of the force transmission from the structure to the mechanical structure’s foundation, which is one of the force transmissibility problems commonly reported in the literature <sup>[</sup><xref ref-type="bibr" rid="B21"><sup>21</sup></xref><sup>]</sup>. Hence, in this paper the calibration process of the dimensionless transmissibility function is presented using the fixed-point technique (FPT) that is based on Krenk’s theory. Then, the <inline-formula id="e9">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie9.jpg"/>
				</inline-formula> and <inline-formula id="e10">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie10.jpg"/>
				</inline-formula> criteria are proposed as dynamic performance measures for the performance evaluation of both harmonic and random vibration inputs. In the first instance, the double rack-pinion inerter’s operating principle and motion equation is presented with the aim of analytically explaining its operation mechanism, which was developed by the authors.</p>
		</sec>
		<sec>
			<title>2. Theoretical mechanical models</title>
			<p>Currently, there are several simple physical designs of the inerter, such designs are the following: the rack-pinion mechanism-based inerter, ball-screw type inerter and the last one based on the hydraulic transmission, among other modern inerters reported in <sup>[</sup><xref ref-type="bibr" rid="B20"><sup>20</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B22"><sup>22</sup></xref><sup>]</sup>. In order to provide a greater rotational inertia, a double rack-pinion type inerter could be used, see. <xref ref-type="fig" rid="f1">Fig. 1</xref>. The double rack-pinion type inerter is mainly composed of a rack that consists of teeth on both the top and bottom, a gear transmission system with a ratio of 2 to 1, and two flywheels.</p>
			<p>
				<fig id="f1">
					<label>Figure 1</label>
					<caption>
						<title>Double rack-pinion type inerter</title>
					</caption>
					<graphic xlink:href="2346-2183-dyna-90-225-131-gf1.png"/>
					<attrib>Source: Authors</attrib>
				</fig>
			</p>
			<p>In <xref ref-type="fig" rid="f1">Fig. 1</xref>, <italic>f</italic>
 <sub>
 <italic>e</italic>
</sub> (<italic>t</italic>), <italic>x</italic>
 <sub>1</sub> (<italic>t</italic>) and <italic>x</italic>
 <sub>2</sub> represent force input, rack’s displacement (terminal 1), and inerter’s terminal 2 displacement, respectively. With this in mind, the inerter’s dynamic equation can be easily obtained by applying the Euler-Lagrange formulism. By doing this, it results in the following:</p>
			<p>
				<disp-formula id="e11">
					<graphic xlink:href="2346-2183-dyna-90-225-131-e11.jpg"/>
				</disp-formula>
			</p>
			<p>where, <italic>b</italic> is the inerter’s inertance in units of kilograms, which can be increased either by changing the gear transmission ratio or increasing the flywheel’s rotational inertia. From eq. (1), the force exerted by the inerter is directly proportional to the acceleration difference <inline-formula id="e12">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie12.jpg"/>
				</inline-formula> of its terminals. In the next section, the inerter’s intrinsic dynamic properties are explained, and how they can improve the control performance of classic DVAs.</p>
			<sec>
				<title>2.1. Inerter-based mechanical systems</title>
				<p>In this section, the theoretical mathematical models are obtained when the inerter is coupled to the single and two degree-of-freedom mechanical systems, in order to reveal its vibration mitigation effectiveness in base-excited structures.</p>
				<p>In <xref ref-type="fig" rid="f2">Fig. 2</xref>, three undamped mechanical systems are described, of which b) and c) are of two degrees-of-freedom (DOF), while the first shown in a) is only of a single DOF. In addition, the dynamical system shown in <xref ref-type="fig" rid="f2">Fig. 2</xref> c) is analogous to the Tuned-Mass-Damper-Inerter (TMDI) <sup>[</sup><xref ref-type="bibr" rid="B23"><sup>23</sup></xref><sup>]</sup>. Note that, the inerter’s terminals are strategically configured to reveal its operation principle, especially when the systems shown in <xref ref-type="fig" rid="f2">Fig. 2</xref> are subjected to the resonance. Indeed, it implies to analyze the dimensionless frequency response function (FRF) of the force that is transmitted towards the base of the primary structure. To achieve such a target, it is necessary to write the motion equations for each dynamical system in a dimensionless form, as described in eq. (2).</p>
				<p>
					<fig id="f2">
						<label>Figure 2</label>
						<caption>
							<title>The inerter coupled to single and two degrees-of-freedom mechanical systems. a) grounded inerter-based vibration isolator, b) ungrounded inerter-based DVA and c) grounded inerter-based DVA (TMDI).</title>
						</caption>
						<graphic xlink:href="2346-2183-dyna-90-225-131-gf2.png"/>
						<attrib>Source: Authors</attrib>
					</fig>
				</p>
				<p>
					<disp-formula id="e13">
						<graphic xlink:href="2346-2183-dyna-90-225-131-e13.jpg"/>
					</disp-formula>
				</p>
				<p>From eq. (2), <italic>β</italic> is absorber to primary structure mass ratio, while <italic>μ</italic> is inertance to absorber’s physical mass ratio. Then, <italic>q</italic> is undamped circular frequency ratio. Furthermore, <inline-formula id="e14">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie14.jpg"/>
					</inline-formula> and <inline-formula id="e15">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie15.jpg"/>
					</inline-formula> are the damping factors for the primary structure and the absorber, respectively. Finally, Ω is the forced frequency ratio. It is worth mentioning that if the system shown in <xref ref-type="fig" rid="f2">Fig. 2</xref> a) is undamped, it is easy to determine its natural frequency <italic>ω</italic>
 <sub>
 <italic>n</italic>
</sub> from the dimensionless eq. (2)-a). This results in:</p>
				<p>
					<disp-formula id="e16">
						<graphic xlink:href="2346-2183-dyna-90-225-131-e16.jpg"/>
					</disp-formula>
				</p>
				<p>Note that, if the inertance <italic>b</italic> increases in eq. (3), the primary structure’s natural frequency <italic>ω</italic>
 <sub>
 <italic>n</italic>
</sub> decreases. It means that the inerter can modify the vibration isolator’s natural frequency, which allows it to work away of resonance. However, the primary system’s dynamic response increases by increasing the inerter’s inertance. This results in the inerter assisting the movement of the primary structure, providing a similar effect to that produced by the negative stiffness damper (NSD) <sup>[</sup><xref ref-type="bibr" rid="B24"><sup>24</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B25"><sup>25</sup></xref><sup>]</sup>. In fact, this can be easily proved by applying the Fourier transform to the inerter’s dynamic equation. It gives the following equation:</p>
				<p>
					<disp-formula id="e17">
						<graphic xlink:href="2346-2183-dyna-90-225-131-e17.jpg"/>
					</disp-formula>
				</p>
				<p>From eq. (4), it is clear to note that the product - <italic>bω</italic>
 <sup>2</sup> results in negative stiffness physical units. This is one of the most inerter’s beneficial dynamic properties, which is worth exploiting in passive control systems. When the inerter’s terminals are not connected to the mechanical ground as shown in <xref ref-type="fig" rid="f2">Fig. 2</xref> b), it is not easy to qualitatively determine its control effect on the primary structure mass <italic>M</italic>
 <sub>
 <italic>s</italic>
</sub> . Meanwhile, control effect for the grounded inerter-based DVA depicted in <xref ref-type="fig" rid="f2">Fig. 2</xref> c), which is intuitive as it will increase the DVA’s control force causing the primary structure’s dynamic response reduction. This will be revealed in the next section through a frequency calibration process based on the FPT.</p>
			</sec>
		</sec>
		<sec sec-type="methods">
			<title>3. Frequency calibration procedure</title>
			<p>To apply the FPT, it is necessary to compute the transmissibility FRFs for the dynamic systems described in <xref ref-type="fig" rid="f2">Fig. 2</xref> b) and c). Such dimensionless functions can be computed by simultaneously solving the sets of eqs. (2) (b) and (c). By doing this, the following are obtained.</p>
			<p>
				<disp-formula id="e18">
					<graphic xlink:href="2346-2183-dyna-90-225-131-e18.jpg"/>
				</disp-formula>
			</p>
			<p>
				<disp-formula id="e19">
					<graphic xlink:href="2346-2183-dyna-90-225-131-e19.jpg"/>
				</disp-formula>
			</p>
			<p>Note that, eq. (5) represents the dimensionless transmissibility FRF for the system shown in <xref ref-type="fig" rid="f2">Fig. 2</xref> (b), while the eq. (6) denotes that of the system depicted in <xref ref-type="fig" rid="f2">Fig. 2</xref> (c). Then the subfunctions of these FRFs can be written as follows:</p>
			<p>
				<disp-formula id="e20">
					<graphic xlink:href="2346-2183-dyna-90-225-131-e20.jpg"/>
				</disp-formula>
			</p>
			<p>The FPT basically consists of two operating modes of the absorber’s damper. The first mode is when the damping factor <inline-formula id="e21">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie21.jpg"/>
				</inline-formula> approaches zero, which means that the resulting system becomes a two-DOF mechanical system with two undamped resonant frequencies. The second mode is when the damping factor <inline-formula id="e22">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie22.jpg"/>
				</inline-formula> approaches infinite value, which implies that the damper is blocked causing the masses <italic>m</italic>
 <sub>1</sub> and <italic>M</italic>
 <sub>
 <italic>s</italic>
</sub> are virtually clamped together. By applying these conditions to the FRFs given by eqs. (5) and (6), the following are produced.</p>
			<p>
				<disp-formula id="e23">
					<graphic xlink:href="2346-2183-dyna-90-225-131-e23.jpg"/>
				</disp-formula>
			</p>
			<p>
				<disp-formula id="e24">
					<graphic xlink:href="2346-2183-dyna-90-225-131-e24.jpg"/>
				</disp-formula>
			</p>
			<p>Considering the plus sign into eq. (7), the trivial solution for the dimensionless variable <italic>q</italic> is yielded. While the minus sign yields the transmissibility FRF’s invariant frequencies, see the first equation of the set of eq. (9). Additionally, these invariant frequencies can also be expressed in terms of the tuning magnitude |<italic>T</italic>
 <sub>
 <italic>b</italic>
</sub> |, as described by the second equation of eq. (9).</p>
			<p>
				<disp-formula id="e25">
					<graphic xlink:href="2346-2183-dyna-90-225-131-e25.jpg"/>
				</disp-formula>
			</p>
			<p>Taking into consideration that the ratio <inline-formula id="e26">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie26.jpg"/>
				</inline-formula>, the biquadratic equations of eq. (9) yield positive real roots that are generally well known in the literature as dynamic system’s invariant frequencies <sup>[</sup><xref ref-type="bibr" rid="B26"><sup>26</sup></xref><sup>]</sup>. The fixed-point technique holds that vibration amplitudes yielded at the transmissibility FRF’s invariant frequencies must be equal. To achieve this target, it is necessary to apply Vieta’s theorem to the set of equations of eq. (9). This leads to the calibration of the invariant frequencies by means of the optimal variable q which is given by the following mathematical expression.</p>
			<p>
				<disp-formula id="e27">
					<graphic xlink:href="2346-2183-dyna-90-225-131-e27.jpg"/>
				</disp-formula>
			</p>
			<p>In eq. (10), q<sub>
 <italic>b,ópt</italic>
</sub> and |T<sub>
 <italic>b</italic>
</sub> (β)| represent the optimal tuning frequency and the maximum tuning magnitude at the dynamical system’s invariant frequencies for the ungrounded inerter-based DVAs depicted in <xref ref-type="fig" rid="f2">Fig. 2</xref> (b). It is clear to see that the optimal fixed magnitude |T<sub>
 <italic>b</italic>
</sub> (β)| is a monotonic function that increases when the inertance to the DVA’s physical mass ratio μ increases, meaning that the ungrounded inerter does not work well when connected between the masses m<sub>1</sub> and M<sub>
 <italic>s</italic>
</sub> . Note that the FPT quickly revealed the dynamic performance of the ungrounded inerter-based DVA. Now, it is also possible to reveal the performance for grounded inerter-based DVA by applying the EFP to eq. (8). It results in,</p>
			<p>
				<disp-formula id="e28">
					<graphic xlink:href="2346-2183-dyna-90-225-131-e28.jpg"/>
				</disp-formula>
			</p>
			<p>Eq. (11) reveals that the transmissibility FRF contains three invariant frequencies that can be denoted as <inline-formula id="e29">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie29.jpg"/>
				</inline-formula>, <inline-formula id="e30">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie30.jpg"/>
				</inline-formula> and <inline-formula id="e31">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie31.jpg"/>
				</inline-formula>. The existence of the third invariant frequency <inline-formula id="e32">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie32.jpg"/>
				</inline-formula> does not directly allow the application of the FPT in a conventional way. Inspired by the methodology developed by Hu et al. <sup>[</sup><xref ref-type="bibr" rid="B27"><sup>27</sup></xref><sup>]</sup>, the invariant frequencies of eq. (11) can be written as follows.</p>
			<p>
				<disp-formula id="e33">
					<graphic xlink:href="2346-2183-dyna-90-225-131-e33.jpg"/>
				</disp-formula>
			</p>
			<p>The auxiliary equation that relates to the invariant frequencies <inline-formula id="e34">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie34.jpg"/>
				</inline-formula> and <inline-formula id="e35">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie35.jpg"/>
				</inline-formula> is obtained when eq. (8) is evaluated at <inline-formula id="e36">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie36.jpg"/>
				</inline-formula> →∞, creating the possibility to compute the optimal variable q. This equation is the following:</p>
			<p>
				<disp-formula id="e37">
					<graphic xlink:href="2346-2183-dyna-90-225-131-e37.jpg"/>
				</disp-formula>
			</p>
			<p>Both square invariant frequency <inline-formula id="e38">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie38.jpg"/>
				</inline-formula> and the optimal variable q<sub>
 <italic>c,ópt</italic>
</sub> can be determined by combining the set of equations of eq. (12) together with that given by (13). By performing this, the following are yielded.</p>
			<p>
				<disp-formula id="e39">
					<graphic xlink:href="2346-2183-dyna-90-225-131-e39.jpg"/>
				</disp-formula>
			</p>
			<p>where,</p>
			<p>
				<disp-formula id="e40">
					<graphic xlink:href="2346-2183-dyna-90-225-131-e40.jpg"/>
				</disp-formula>
			</p>
			<p>Thus, the remaining invariant frequencies can be computed by substituting <inline-formula id="e41">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie41.jpg"/>
				</inline-formula> into eq. (12). For the specific mass ratios β = 0.1 and μ = 1, the optimal tuning variable q<sub>
 <italic>c,ópt</italic>
</sub> = 1.2028 is computed by eq. (14). Then, the three invariant frequencies for the grounded inerter-based DVA are described in <xref ref-type="fig" rid="f3">Fig. 3</xref>.</p>
			<p>
				<fig id="f3">
					<label>Figure 3</label>
					<caption>
						<title>Invariant frequencies and maximum tuning magnitude for the grounded inerter-based DVA’s dimensionless transmissibility FRF.</title>
					</caption>
					<graphic xlink:href="2346-2183-dyna-90-225-131-gf3.png"/>
					<attrib>Source: Authors</attrib>
				</fig>
			</p>
			<p>In <xref ref-type="fig" rid="f3">Fig. 3</xref>, it is possible to note that the transmissibility FRF presents two well-calibrated invariant points which are both denoted as the optimal tuning magnitude |T<sub>
 <italic>c</italic>
</sub> |<sub>fijo</sub>. Moreover, the invariant frequency <inline-formula id="e42">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie42.jpg"/>
				</inline-formula> is always higher than the <inline-formula id="e43">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie43.jpg"/>
				</inline-formula> and <inline-formula id="e44">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie44.jpg"/>
				</inline-formula>. Based on this observation, in order to compute the optimal damping factor, the Krenk’s damping factor tuning technique is employed here <sup>[</sup><xref ref-type="bibr" rid="B28"><sup>28</sup></xref><sup>]</sup>. This theory holds the existence of a singular frequency when the absorber’s dashpot is blocked, yielding a vibration amplitude must have the same vibration magnitude as those produced at the invariant frequencies <inline-formula id="e45">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie45.jpg"/>
				</inline-formula> and <inline-formula id="e46">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie46.jpg"/>
				</inline-formula>. Because the analytical solution for the optimal damping factor <inline-formula id="e47">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie47.jpg"/>
				</inline-formula> is a very long rational mathematical expression, the optimal numerical values of such a solution are presented in <xref ref-type="table" rid="t1">Table 1</xref> for the range of μ ∈ [0.5,2].</p>
			<p>
				<table-wrap id="t1">
					<label>Table 1</label>
					<caption>
						<title>Numerical solutions for both <inline-graphic xlink:href="2346-2183-dyna-90-225-131-i049.jpg"/> and FPT</title>
					</caption>
					<table>
						<colgroup>
							<col span="6"/>
						</colgroup>
						<thead>
							<tr>
								<th align="left" colspan="6">a) ℋ<sub>∞</sub> criterion </th>
							</tr>
						</thead>
						<tbody>
							<tr>
								<td align="center"> </td>
								<td align="center">μ</td>
								<td align="center">q<sub>ópt</sub></td>
								<td align="center">𝜁1,ópt </td>
								<td align="center">r<sub>min</sub></td>
								<td align="center"> ℋ∞ norm</td>
							</tr>
							<tr>
								<td align="center" rowspan="5">β = 0.1</td>
								<td align="center">0</td>
								<td align="center">0.9090</td>
								<td align="center"> 0.1854</td>
								<td align="center">0.9759</td>
								<td align="center">4.5891</td>
							</tr>
							<tr>
								<td align="center">0.5</td>
								<td align="center">1.0760</td>
								<td align="center">0.2745</td>
								<td align="center">0.9633</td>
								<td align="center">3.7299</td>
							</tr>
							<tr>
								<td align="center">1</td>
								<td align="center">1.2023</td>
								<td align="center">0.3607</td>
								<td align="center">0.9506</td>
								<td align="center">3.2240</td>
							</tr>
							<tr>
								<td align="center">1.5</td>
								<td align="center">1.3023</td>
								<td align="center">0.4443</td>
								<td align="center">0.9379</td>
								<td align="center">2.8835</td>
							</tr>
							<tr>
								<td align="center">2</td>
								<td align="center">1.3838</td>
								<td align="center">0.5252</td>
								<td align="center">0.9252</td>
								<td align="center">2.6360</td>
							</tr>
							<tr>
								<td align="left" colspan="6">b) Fixed-points technique </td>
								<td align="center">|𝑇𝑐|fijo</td>
							</tr>
							<tr>
								<td align="center" rowspan="4">β = 0.1</td>
								<td align="center">0</td>
								<td align="center">0.9090</td>
								<td align="center">0.2132</td>
								<td align="center">---</td>
								<td align="center">4.5825</td>
							</tr>
							<tr>
								<td align="center">0.5</td>
								<td align="center">1.0762</td>
								<td align="center">0.3124</td>
								<td align="center">---</td>
								<td align="center">3.7103</td>
							</tr>
							<tr>
								<td align="center">1</td>
								<td align="center">1.2028</td>
								<td align="center">0.4070</td>
								<td align="center">---</td>
								<td align="center">3.1944</td>
							</tr>
							<tr>
								<td align="center">1.5</td>
								<td align="center">1.3033</td>
								<td align="center">0.4973</td>
								<td align="center">---</td>
								<td align="center">2.8465</td>
							</tr>
							<tr>
								<td align="center">2</td>
								<td align="center">1.3853</td>
								<td align="center">0.5837</td>
								<td align="center">---</td>
								<td align="center">2.5939</td>
							</tr>
						</tbody>
					</table>
					<table-wrap-foot>
						<fn id="TFN1">
							<p>Source: Authors</p>
						</fn>
					</table-wrap-foot>
				</table-wrap>
			</p>
			<p>In order to differentiate the inerter’s control effect in the anti-vibration devices shown in <xref ref-type="fig" rid="f2">Fig. 2</xref> (b) and (c), it is necessary to perform a numerical simulation considering the optimal numerical solutions depicted in <xref ref-type="table" rid="t1">Table 1</xref>. By performing this, the undamped primary structure’s optimal FRF curves evolution is shown in <xref ref-type="fig" rid="f4">Fig. 4</xref>.</p>
			<p>
				<fig id="f4">
					<label>Figure 4</label>
					<caption>
						<title>Optimal transmissibility FRF curves considering the mass ratio of the β = 0.1 and μ ∈ [0.5,2].</title>
					</caption>
					<graphic xlink:href="2346-2183-dyna-90-225-131-gf4.png"/>
					<attrib>Source: Authors</attrib>
				</fig>
			</p>
			<p>When observing the optimal transmissibility FRF curves in <xref ref-type="fig" rid="f4">Fig. 4</xref>, the transmissibility FRF’s vibration amplitude increases for ungrounded inerter-based DVA coupled to the primary structure, while for the grounded inerter-based DVA decreases. This is mainly due to the inerter’s inertial mass amplification and the negative stiffness effects. Therefore, the classic DVA’s control performance can be improved by using a grounded inerter. To fairly assess the control performance for grounded inerter-based DVA, it is necessary to apply the performance measures <inline-formula id="e48">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie48.jpg"/>
				</inline-formula> and <inline-formula id="e49">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie49.jpg"/>
				</inline-formula>.</p>
		</sec>
		<sec>
			<title>4. Performance evaluation</title>
			<p>To evaluate the vibration mitigation potential for anti-vibration systems subjected to both harmonic and random vibrations, many researchers often use control performance measures <inline-formula id="e50">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie50.jpg"/>
				</inline-formula> and <inline-formula id="e51">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie49.jpg"/>
				</inline-formula>. When the dynamical system is under harmonic vibration, the <inline-formula id="e52">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie52.jpg"/>
				</inline-formula> criterion is more convenient to use than the <inline-formula id="e53">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie53.jpg"/>
				</inline-formula> criterion. In addition, <inline-graphic xlink:href="2346-2183-dyna-90-225-131-i056.jpg"/> criterion focuses on minimizing the control signal’s supreme value, meanwhile the <inline-formula id="e54">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie54.jpg"/>
				</inline-formula> criterion is used to minimize the total vibration energy into the system under random vibration <sup>[</sup><xref ref-type="bibr" rid="B29"><sup>29</sup></xref><sup>]</sup>.</p>
			<sec>
				<title><italic>4.1. ℋ∞ criterion</italic></title>
				<p>The transmissibility FRF’s supreme values for the grounded inerter-based DVA can be calculated through eq. (8), which basically represent the dynamical system’s resonant peaks. In the literature, it has been reported that the system’s best dynamic balance can be achieved when the resonant peaks reach the same Dynamic Magnification Factor (DMF) <sup>[</sup><xref ref-type="bibr" rid="B30"><sup>30</sup></xref><sup>]</sup>. In order to achieve this dynamic trade-off between the resonant peaks, a constrained nonlinear multivariable optimization problem needs to be formulated herein,</p>
				<p>
					<disp-formula id="e55">
						<graphic xlink:href="2346-2183-dyna-90-225-131-e55.jpg"/>
					</disp-formula>
				</p>
				<p>Note that the nonlinear optimization problem given by formulation (17) can be numerically solved as in <sup>[</sup><xref ref-type="bibr" rid="B31"><sup>31</sup></xref><sup>]</sup>. However, in order to achieve a high precision in the minimization process of the system’s resonant points, it is convenient to use the methodology recently developed by Asami et al. <sup>[</sup><xref ref-type="bibr" rid="B32"><sup>32</sup></xref><sup>]</sup>. For two-DOF mechanical systems, Asami’s methodology holds that the primary structure’s FRF becomes a fourth-order algebraic equation <inline-formula id="e56">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie56.jpg"/>
					</inline-formula> in terms of <inline-formula id="e57">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie57.jpg"/>
					</inline-formula> when the magnitude |H<sub>
 <italic>M</italic>
</sub> | is replaced by function <inline-formula id="e58">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie58.jpg"/>
					</inline-formula>. Now, by defining the control square resonant frequencies as <inline-formula id="e59">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie59.jpg"/>
					</inline-formula> and <inline-formula id="e60">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie60.jpg"/>
					</inline-formula>, then <inline-formula id="e61">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie61.jpg"/>
					</inline-formula>. The variable Ω can be deleted by properly applying Vieta’s theorem, resulting in an overdetermined system with two nonlinear equations <inline-formula id="e62">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie62.jpg"/>
					</inline-formula>. It is worth emphasizing that the overdetermined system provides a necessary condition, but not sufficient to yield a trade-off between the two resonant peaks. The remaining condition can be obtained by using the Jacobian matrix <inline-formula id="e63">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie63.jpg"/>
					</inline-formula> of the infinitesimal variation of unknown variable r with respect to the design parameters <inline-formula id="e64">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie64.jpg"/>
					</inline-formula>. Then, the optimality criteria approach is satisfied when any 2x2 minor determinant of the Jacobian matrix is equalized zero. By calculating such a determinant, a constitutive equation is obtained that completes the conditions to solve the overdetermined system. Therefore, the objective function given by eq. (8) can be precisely minimized at two resonant peaks by solving the following set of nonlinear equations.</p>
				<p>
					<disp-formula id="e65">
						<graphic xlink:href="2346-2183-dyna-90-225-131-e65.jpg"/>
					</disp-formula>
				</p>
				<p>where <inline-formula id="e66">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie66.jpg"/>
					</inline-formula> for i = 1,..4 are rational functions described in Appendix A. Then, the set of nonlinear equations of eq. (18) can be solved through the Newton-Raphson method, considering the numerical solutions described in <xref ref-type="table" rid="t1">Table 1</xref> as convergence initial points. For the sake of the fair comparison, a numerical simulation comparison between the FPT and <inline-formula id="e67">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie67.jpg"/>
					</inline-formula> criteria needs to be performed. By selecting the mass ratios β = 0.1 and μ = 1, the optimal FRFs are shown in <xref ref-type="fig" rid="f5">Fig. 5</xref>.</p>
				<p>
					<fig id="f5">
						<label>Figure 5</label>
						<caption>
							<title>Numerical comparison between the tuning FPT and the <inline-formula id="e68">
									<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie68.jpg"/>
								</inline-formula> criterion, considering the mass ratios β = 0.1 and μ = 1.</title>
						</caption>
						<graphic xlink:href="2346-2183-dyna-90-225-131-gf5.png"/>
						<attrib>Source: Authors</attrib>
					</fig>
				</p>
				<p>From <xref ref-type="fig" rid="f5">Fig. 5</xref>, the maximum tuning magnitude |T<sub>
 <italic>b</italic>
</sub> |<sub>fijo</sub> yielded at invariant frequencies is approximately equal to that produced at resonant frequencies which can be denoted as <inline-formula id="e69">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie69.jpg"/>
					</inline-formula> norm, meaning that the FPT is an approximation to the <inline-formula id="e70">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie50.jpg"/>
					</inline-formula> optimization. Additionally, the percentage of the dynamic magnification factor reduction (%DMFR) is approximately 29.74% when the inerter’s inertial force effect is the same as that produced by the DVA’s physical mass. Indeed, it is evident that the grounded inerter’s intrinsic dynamic characteristics significantly improve the control performance of the classic DVA under harmonic vibration. When the system is subjected to random vibration, the optimal parameters change because the control objective is the minimization of the total vibration energy instead of resonant peaks. In this regard, the <inline-formula id="e71">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie71.jpg"/>
					</inline-formula> criterion is more convenient than <inline-formula id="e72">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie67.jpg"/>
					</inline-formula> norm.</p>
			</sec>
			<sec>
				<title><italic>4.2. ℋ</italic>
 <sub>
 <italic>2</italic>
</sub> criterion</title>
				<p>The performance measure <inline-formula id="e74">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie71.jpg"/>
					</inline-formula> is mainly based on the minimization of the expected value of the system’s dynamic response subjected to a stationary stochastic process whose power spectral density (PSD) is uniform at the whole excitation frequency band. Considering the input PSD of the signal x<sub>
 <italic>e</italic>
</sub> (t) is <inline-formula id="e75">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie75.jpg"/>
					</inline-formula>, then the output PSD is <inline-formula id="e76">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie76.jpg"/>
					</inline-formula>. Therefore, the expected value is given by the following mathematical expression,</p>
				<p>
					<disp-formula id="e77">
						<graphic xlink:href="2346-2183-dyna-90-225-131-e77.jpg"/>
					</disp-formula>
				</p>
				<p>Note that eq. (17) represents the total vibrational energy of the dynamic system over the whole range of excitation frequencies, which can be expressed in a dimensionless form when the response |T<sub>
 <italic>c</italic>
</sub> (ω)|<sup>2</sup> becomes in <inline-formula id="e78">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie78.jpg"/>
					</inline-formula><sup>[</sup><xref ref-type="bibr" rid="B33"><sup>33</sup></xref><sup>]</sup>. It gives,</p>
				<p>
					<disp-formula id="e79">
						<graphic xlink:href="2346-2183-dyna-90-225-131-e79.jpg"/>
					</disp-formula>
				</p>
				<p>In eq. (18), the mathematical term <inline-formula id="e80">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie80.jpg"/>
					</inline-formula> is not only commonly known as the dimensionless variance of the system’s dynamic response, but also as the control performance index <inline-formula id="e81">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie71.jpg"/>
					</inline-formula><sup>[</sup><xref ref-type="bibr" rid="B34"><sup>34</sup></xref><sup>]</sup>. Then, the improper integral can be calculated either by the integration method of residues <sup>[</sup><xref ref-type="bibr" rid="B35"><sup>35</sup></xref><sup>]</sup> or obtaining the unique solution of the Lyapunov equation <sup>[</sup><xref ref-type="bibr" rid="B36"><sup>36</sup></xref><sup>]</sup>. When the integration method of residues is applied in eq. (18), it becomes:</p>
				<p>
					<disp-formula id="e82">
						<graphic xlink:href="2346-2183-dyna-90-225-131-e82.jpg"/>
					</disp-formula>
				</p>
				<p>where,</p>
				<p>
					<disp-formula id="e83">
						<graphic xlink:href="2346-2183-dyna-90-225-131-e83.jpg"/>
					</disp-formula>
				</p>
				<p>It is easy to see that the rational function of the integrand of eq. (19) has four simple poles (Ω<sub>1</sub>, Ω<sub>2</sub>, Ω<sub>3</sub> y Ω<sub>4</sub>) that are located in the upper middle part of the complex plane. Then, the residues yielded at each simple pole can be written as follows:</p>
				<p>
					<disp-formula id="e84">
						<graphic xlink:href="2346-2183-dyna-90-225-131-e84.jpg"/>
					</disp-formula>
				</p>
				<p>In eq. (21) <inline-formula id="e85">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie85.jpg"/>
					</inline-formula> is the imaginary unit. Then, the residues of eq. (21) can be simplified by using Vieta’s theorem, yielding the analytical mathematical expression for the dimensionless variance <inline-formula id="e86">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie86.jpg"/>
					</inline-formula> given in terms of the coefficients described in eq. (20). It results in the following:</p>
				<p>
					<disp-formula id="e87">
						<graphic xlink:href="2346-2183-dyna-90-225-131-e87.jpg"/>
					</disp-formula>
				</p>
				<p>Finally, the dimensionless variance <inline-formula id="e88">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie88.jpg"/>
					</inline-formula> is,</p>
				<p>
					<disp-formula id="e89">
						<graphic xlink:href="2346-2183-dyna-90-225-131-e89.jpg"/>
					</disp-formula>
				</p>
				<p>Now, it is necessary to formulate an unconstrained nonlinear multivariable optimization problem to minimize the dimensionless variance <inline-formula id="e90">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie90.jpg"/>
					</inline-formula>, as follows:</p>
				<p>
					<disp-formula id="e91">
						<graphic xlink:href="2346-2183-dyna-90-225-131-e91.jpg"/>
					</disp-formula>
				</p>
				<p>The optimal variables q<sub>ópt</sub> and <inline-formula id="e92">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie92.jpg"/>
					</inline-formula> satisfy to eq. (24), are obtained by solving the following set of nonlinear equations.</p>
				<p>
					<disp-formula id="e93">
						<graphic xlink:href="2346-2183-dyna-90-225-131-e93.jpg"/>
					</disp-formula>
				</p>
				<p>therefore,</p>
				<p>
					<disp-formula id="e94">
						<graphic xlink:href="2346-2183-dyna-90-225-131-e94.jpg"/>
					</disp-formula>
				</p>
				<p>The analytical solutions given by eq. (26) minimize the system’s total vibration energy, which also yields the significant reduction of the primary structure’s dynamic displacement. It is worth performing a numerical simulation to evaluate the control performance for the grounded inerter-based DVA considering the numerical solutions β = 0.1, μ = 1, q<sub>ópt</sub> = 1.2856 and <inline-formula id="e95">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie95.jpg"/>
					</inline-formula> = 0.3224, see <xref ref-type="fig" rid="f6">Fig. 6</xref>.</p>
				<p>
					<fig id="f6">
						<label>Figure 6</label>
						<caption>
							<title>Optimal FRF curves computed via <inline-formula id="e96">
									<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie71.jpg"/>
								</inline-formula> criterion. The classic DVA’s optimal parameters are q<sub>ópt</sub> = 0.9315 and <inline-formula id="e97">
									<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie95.jpg"/>
								</inline-formula> = 0.1525.</title>
						</caption>
						<graphic xlink:href="2346-2183-dyna-90-225-131-gf6.png"/>
						<attrib>Source: Authors</attrib>
					</fig>
				</p>
				<p>From <xref ref-type="fig" rid="f6">Fig. 6</xref>, it is clear to observe that by increasing the inerter’s rotational inertia, the vibration amplitudes are considerably reduced. Therefore, the grounded inerter-based DVA can effectively mitigate random vibration and consequently reduces the energy transmitted to the foundation. In addition, the control performance <inline-formula id="e98">
						<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie98.jpg"/>
					</inline-formula> can be calculated similarly as in <sup>[</sup><xref ref-type="bibr" rid="B31"><sup>31</sup></xref><sup>]</sup>, being approximately 33.03%.</p>
			</sec>
		</sec>
		<sec sec-type="conclusions">
			<title>5. Conclusion</title>
			<p>In this work, the inerter’s dynamic was coupled to single and two DOF mechanical systems with the aim of revealing its control effect under harmonic and random vibrations. It was theoretically demonstrated by means of the FPT that the inerter does not provide a good control performance when its terminals are connected between the primary structure mass and that of the absorber, demonstrating a detrimental effect on the system’s dynamic response. However, when one of its terminals is connected to the ground and the another to the absorber mass, the inerter provides excellent control performance. To demonstrate the vibration attenuation effectiveness of the inerter device coupled to harmonically and randomly excited mechanical systems, the performance criteria <inline-formula id="e99">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie99.jpg"/>
				</inline-formula> and <inline-formula id="e100">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie100.jpg"/>
				</inline-formula> were computed from formulation of the constrained and unconstrained nonlinear multivariable optimization problems. When the inerter’s inertial force effect is equal to that yielded by the absorber physical mass, the numerical solutions for the <inline-formula id="e101">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie52.jpg"/>
				</inline-formula> criterion revealed that the grounded inerter-based DVA provides an improvement of approximately 29.74% in reducing the transmissibility FRF’s resonant peaks; whereas, the analytical solutions for <inline-formula id="e102">
					<inline-graphic xlink:href="2346-2183-dyna-90-225-131-ie71.jpg"/>
				</inline-formula> criterion revealed a dynamic improvement of approximately 33.03% in minimizing the total vibration energy transmitted to the foundation. Therefore, the control performance of classic DVA can be significantly improved by the inerter’s inertial mass amplification and the negative stiffness effects.</p>
		</sec>
	</body>
	<back>
		<ack>
			<title>Acknowledgment</title>
			<p>This work was partially financed by the Technological University of the Mixteca (UTM).</p>
		</ack>
		<ref-list>
			<title>References</title>
			<ref id="B1">
				<mixed-citation>[1] Den-Hartog, J-P., Mechanical vibrations, Dover Publications, 1947, pp. 119-132.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Den-Hartog</surname>
							<given-names>J-P</given-names>
						</name>
					</person-group>
					<source>Mechanical vibrations</source>
					<publisher-name>Dover Publications</publisher-name>
					<year>1947</year>
					<fpage>119</fpage>
					<lpage>132</lpage>
				</element-citation>
			</ref>
			<ref id="B2">
				<mixed-citation>[2] Brock, J-E., Theory of the damped dynamic vibration absorber for inertial disturbances, Transactions of the ASME, 16(1), pp. 86-92, 1949. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.4009897">https://doi.org/10.1115/1.4009897</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Brock</surname>
							<given-names>J-E</given-names>
						</name>
					</person-group>
					<article-title>Theory of the damped dynamic vibration absorber for inertial disturbances</article-title>
					<source>Transactions of the ASME</source>
					<volume>16</volume>
					<issue>1</issue>
					<fpage>86</fpage>
					<lpage>92</lpage>
					<year>1949</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.4009897">https://doi.org/10.1115/1.4009897</ext-link>
				</element-citation>
			</ref>
			<ref id="B3">
				<mixed-citation>[3] Ren, M.Z., A variant design of the dynamic vibration absorber, Journal of Sound and Vibration, 245(4), pp. 762-770, 2001. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1006/jsvi.2001.3564">https://doi.org/10.1006/jsvi.2001.3564</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Ren</surname>
							<given-names>M.Z</given-names>
						</name>
					</person-group>
					<article-title>A variant design of the dynamic vibration absorber</article-title>
					<source>Journal of Sound and Vibration</source>
					<volume>245</volume>
					<issue>4</issue>
					<fpage>762</fpage>
					<lpage>770</lpage>
					<year>2001</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1006/jsvi.2001.3564">https://doi.org/10.1006/jsvi.2001.3564</ext-link>
				</element-citation>
			</ref>
			<ref id="B4">
				<mixed-citation>[4] Nishihara, O., Exact optimization of a three-element dynamic vibration absorber: minimization of the maximum amplitude magnification factor, Journal of Vibration and Acoustics, 141(1), pp. 1-7, 2019. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.4040575">https://doi.org/10.1115/1.4040575</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Nishihara</surname>
							<given-names>O</given-names>
						</name>
					</person-group>
					<article-title>Exact optimization of a three-element dynamic vibration absorber: minimization of the maximum amplitude magnification factor</article-title>
					<source>Journal of Vibration and Acoustics</source>
					<volume>141</volume>
					<issue>1</issue>
					<fpage>1</fpage>
					<lpage>7</lpage>
					<year>2019</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.4040575">https://doi.org/10.1115/1.4040575</ext-link>
				</element-citation>
			</ref>
			<ref id="B5">
				<mixed-citation>[5] Anh, N.D., Nguyen, N.X. and Hoa, L.T., Design of three-element dynamic vibration absorber for damped linear structures, Journal of Sound and Vibration , 332(19), pp. 4482-4495, 2013. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jsv.2013.03.032">https://doi.org/10.1016/j.jsv.2013.03.032</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Anh</surname>
							<given-names>N.D.</given-names>
						</name>
						<name>
							<surname>Nguyen</surname>
							<given-names>N.X.</given-names>
						</name>
						<name>
							<surname>Hoa</surname>
							<given-names>L.T</given-names>
						</name>
					</person-group>
					<article-title>Design of three-element dynamic vibration absorber for damped linear structures</article-title>
					<source>Journal of Sound and Vibration</source>
					<volume>332</volume>
					<issue>19</issue>
					<fpage>4482</fpage>
					<lpage>4495</lpage>
					<year>2013</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jsv.2013.03.032">https://doi.org/10.1016/j.jsv.2013.03.032</ext-link>
				</element-citation>
			</ref>
			<ref id="B6">
				<mixed-citation>[6] Kaul, S., Modeling and analysis of passive vibration isolation systems, Elsevier, USA, 2021, pp. 27-61. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/B978-0-12-819420-1.00003-0">https://doi.org/10.1016/B978-0-12-819420-1.00003-0</ext-link>.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Kaul</surname>
							<given-names>S</given-names>
						</name>
					</person-group>
					<source>Modeling and analysis of passive vibration isolation systems</source>
					<publisher-name>Elsevier</publisher-name>
					<publisher-loc>USA</publisher-loc>
					<year>2021</year>
					<fpage>27</fpage>
					<lpage>61</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/B978-0-12-819420-1.00003-0">https://doi.org/10.1016/B978-0-12-819420-1.00003-0</ext-link>
				</element-citation>
			</ref>
			<ref id="B7">
				<mixed-citation>[7] Zuo, L., Effective and robust vibration control using series multiple tuned-mass dampers, Journal of Vibration and Acoustics , 133(1), pp. 1-11, 7 April 2009. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.3085879.">https://doi.org/10.1115/1.3085879. </ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Zuo</surname>
							<given-names>L</given-names>
						</name>
					</person-group>
					<article-title>Effective and robust vibration control using series multiple tuned-mass dampers</article-title>
					<source>Journal of Vibration and Acoustics</source>
					<volume>133</volume>
					<issue>1</issue>
					<fpage>1</fpage>
					<lpage>11</lpage>
					<day>07</day>
					<month>04</month>
					<year>2009</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.3085879.">https://doi.org/10.1115/1.3085879. </ext-link>
				</element-citation>
			</ref>
			<ref id="B8">
				<mixed-citation>[8] Asami, T., Optimal design of double-mass dynamic vibration absorbers arranged in series or in parallel, Journal of Vibration and Acoustics , 139(1), pp. 1-16, 23 November 2016. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.4034776">https://doi.org/10.1115/1.4034776</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Asami</surname>
							<given-names>T</given-names>
						</name>
					</person-group>
					<article-title>Optimal design of double-mass dynamic vibration absorbers arranged in series or in parallel</article-title>
					<source>Journal of Vibration and Acoustics</source>
					<volume>139</volume>
					<issue>1</issue>
					<fpage>1</fpage>
					<lpage>16</lpage>
					<day>23</day>
					<month>11</month>
					<year>2016</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.4034776">https://doi.org/10.1115/1.4034776</ext-link>
				</element-citation>
			</ref>
			<ref id="B9">
				<mixed-citation>[9] Zuo, L. and Nayfeh, S.A., The two-degree-of-freedom tuned-mass damper for suppression of single-mode vibration under random and harmonic excitation, Journal of Vibration and Acoustics , 128(1), pp. 56-65, 1 April 2006. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.2128639">https://doi.org/10.1115/1.2128639</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Zuo</surname>
							<given-names>L.</given-names>
						</name>
						<name>
							<surname>Nayfeh</surname>
							<given-names>S.A</given-names>
						</name>
					</person-group>
					<article-title>The two-degree-of-freedom tuned-mass damper for suppression of single-mode vibration under random and harmonic excitation</article-title>
					<source>Journal of Vibration and Acoustics</source>
					<volume>128</volume>
					<issue>1</issue>
					<fpage>56</fpage>
					<lpage>65</lpage>
					<day>01</day>
					<month>04</month>
					<year>2006</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.2128639">https://doi.org/10.1115/1.2128639</ext-link>
				</element-citation>
			</ref>
			<ref id="B10">
				<mixed-citation>[10] Barredo, E., Mendoza-Larios, J.G., Máyen, J., Flores-Hernández, A.A., Colín, J. and Arias Montiel, M., Optimal design for high-performance passive dynamic vibration absorbers under random vibration, Engineering Structures, 195, pp. 469-489, 15 September 2019. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.engstruct.2019.05.105">https://doi.org/10.1016/j.engstruct.2019.05.105</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Barredo</surname>
							<given-names>E.</given-names>
						</name>
						<name>
							<surname>Mendoza-Larios</surname>
							<given-names>J.G.</given-names>
						</name>
						<name>
							<surname>Máyen</surname>
							<given-names>J.</given-names>
						</name>
						<name>
							<surname>Flores-Hernández</surname>
							<given-names>A.A.</given-names>
						</name>
						<name>
							<surname>Colín</surname>
							<given-names>J.</given-names>
						</name>
						<name>
							<surname>Arias Montiel</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<article-title>Optimal design for high-performance passive dynamic vibration absorbers under random vibration</article-title>
					<source>Engineering Structures</source>
					<volume>195</volume>
					<fpage>469</fpage>
					<lpage>489</lpage>
					<day>15</day>
					<month>09</month>
					<year>2019</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.engstruct.2019.05.105">https://doi.org/10.1016/j.engstruct.2019.05.105</ext-link>
				</element-citation>
			</ref>
			<ref id="B11">
				<mixed-citation>[11] Elias, S. and Matsagar, V., Research developments in vibration control of structures using passive tuned mass dampers, Annual Reviews in Control, 44, pp. 129-156, 2017. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.arcontrol.2017.09.015">https://doi.org/10.1016/j.arcontrol.2017.09.015</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Elias</surname>
							<given-names>S.</given-names>
						</name>
						<name>
							<surname>Matsagar</surname>
							<given-names>V</given-names>
						</name>
					</person-group>
					<article-title>Research developments in vibration control of structures using passive tuned mass dampers</article-title>
					<source>Annual Reviews in Control</source>
					<volume>44</volume>
					<fpage>129</fpage>
					<lpage>156</lpage>
					<year>2017</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.arcontrol.2017.09.015">https://doi.org/10.1016/j.arcontrol.2017.09.015</ext-link>
				</element-citation>
			</ref>
			<ref id="B12">
				<mixed-citation>[12] Zuo, H., Bi, K. and Hao, H., A state-of-the-art review on the vibration mitigation of wind turbines, Renewable and Sustainable Energy Reviews, 121, pp. 1-19, April 2020. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.rser.2020.109710">https://doi.org/10.1016/j.rser.2020.109710</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Zuo</surname>
							<given-names>H.</given-names>
						</name>
						<name>
							<surname>Bi</surname>
							<given-names>K.</given-names>
						</name>
						<name>
							<surname>Hao</surname>
							<given-names>H</given-names>
						</name>
					</person-group>
					<article-title>A state-of-the-art review on the vibration mitigation of wind turbines</article-title>
					<source>Renewable and Sustainable Energy Reviews</source>
					<volume>121</volume>
					<fpage>1</fpage>
					<lpage>19</lpage>
					<month>04</month>
					<year>2020</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.rser.2020.109710">https://doi.org/10.1016/j.rser.2020.109710</ext-link>
				</element-citation>
			</ref>
			<ref id="B13">
				<mixed-citation>[13] Ma, W., Yang, Y. and Yu. J., General routine of suppressing single vibration mode by multi-DOF tuned mass damper: application of three-DOF, Mechanical Systems and Signal Processing, 121, pp. 77-96, April 2019. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.ymssp.2018.11.010">https://doi.org/10.1016/j.ymssp.2018.11.010</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Ma</surname>
							<given-names>W.</given-names>
						</name>
						<name>
							<surname>Yang</surname>
							<given-names>Y.</given-names>
						</name>
						<name>
							<surname>Yu</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<article-title>General routine of suppressing single vibration mode by multi-DOF tuned mass damper: application of three-DOF</article-title>
					<source>Mechanical Systems and Signal Processing</source>
					<volume>121</volume>
					<fpage>77</fpage>
					<lpage>96</lpage>
					<month>04</month>
					<year>2019</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.ymssp.2018.11.010">https://doi.org/10.1016/j.ymssp.2018.11.010</ext-link>
				</element-citation>
			</ref>
			<ref id="B14">
				<mixed-citation>[14] Kim, S.Y. and Lee, C.H., Optimum design of linear multiple tuned mass dampers subjected to white-noise base acceleration considering practical configurations, Engineering Structures , 171, pp. 516-528, 2019. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.engstruct.2018.06.002">https://doi.org/10.1016/j.engstruct.2018.06.002</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Kim</surname>
							<given-names>S.Y.</given-names>
						</name>
						<name>
							<surname>Lee</surname>
							<given-names>C.H</given-names>
						</name>
					</person-group>
					<article-title>Optimum design of linear multiple tuned mass dampers subjected to white-noise base acceleration considering practical configurations</article-title>
					<source>Engineering Structures</source>
					<volume>171</volume>
					<fpage>516</fpage>
					<lpage>528</lpage>
					<year>2019</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.engstruct.2018.06.002">https://doi.org/10.1016/j.engstruct.2018.06.002</ext-link>
				</element-citation>
			</ref>
			<ref id="B15">
				<mixed-citation>[15] Barredo, E., Mendoz-Larios, J.G., Colín, J., Máyen, J., Flores-Hernández, A.A. and Arias-Montiel, M., A novel high-performance passive non-traditional inerter-based dynamic vibration absorber, Journal of Sound and Vibration , 485, pp. 1-24, 2020. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jsv.2020.115583">https://doi.org/10.1016/j.jsv.2020.115583</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Barredo</surname>
							<given-names>E.</given-names>
						</name>
						<name>
							<surname>Mendoz-Larios</surname>
							<given-names>J.G.</given-names>
						</name>
						<name>
							<surname>Colín</surname>
							<given-names>J.</given-names>
						</name>
						<name>
							<surname>Máyen</surname>
							<given-names>J.</given-names>
						</name>
						<name>
							<surname>Flores-Hernández</surname>
							<given-names>A.A.</given-names>
						</name>
						<name>
							<surname>Arias-Montiel</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<article-title>A novel high-performance passive non-traditional inerter-based dynamic vibration absorber</article-title>
					<source>Journal of Sound and Vibration</source>
					<volume>485</volume>
					<fpage>1</fpage>
					<lpage>24</lpage>
					<year>2020</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jsv.2020.115583">https://doi.org/10.1016/j.jsv.2020.115583</ext-link>
				</element-citation>
			</ref>
			<ref id="B16">
				<mixed-citation>[16] Smith, M.C., Synthesis of mechanical networks: the inerter, IEEE Transactions on Automatic Control, 47(10), pp. 1648-1662, October 2002. DOI: 10.1109/TAC.2002.803532. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Smith</surname>
							<given-names>M.C</given-names>
						</name>
					</person-group>
					<article-title>Synthesis of mechanical networks: the inerter</article-title>
					<source>IEEE Transactions on Automatic Control</source>
					<volume>47</volume>
					<issue>10</issue>
					<fpage>1648</fpage>
					<lpage>1662</lpage>
					<month>10</month>
					<year>2002</year>
					<pub-id pub-id-type="doi">10.1109/TAC.2002.803532</pub-id>
				</element-citation>
			</ref>
			<ref id="B17">
				<mixed-citation>[17] Smith, M.C., The inerter: a retrospective, Annual Review of Control, Robotics, and Autonomous Systems, 3, pp. 361-391, May 2020. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1146/annurev-control-053018-023917">https://doi.org/10.1146/annurev-control-053018-023917</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Smith</surname>
							<given-names>M.C</given-names>
						</name>
					</person-group>
					<article-title>The inerter: a retrospective</article-title>
					<source>Annual Review of Control, Robotics, and Autonomous Systems</source>
					<volume>3</volume>
					<fpage>361</fpage>
					<lpage>391</lpage>
					<month>05</month>
					<year>2020</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1146/annurev-control-053018-023917">https://doi.org/10.1146/annurev-control-053018-023917</ext-link>
				</element-citation>
			</ref>
			<ref id="B18">
				<mixed-citation>[18] Chen, M.Q., Papageorgiou, C., Scheibe, F., Wang, F-W. and Smith, M.C., The missing mechanical circuit element, IEEE Circuits and Systems Magazine, 9(1), pp. 10-26, March 2009. DOI: 10.1109/MCAS.2008.931738. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Chen</surname>
							<given-names>M.Q.</given-names>
						</name>
						<name>
							<surname>Papageorgiou</surname>
							<given-names>C.</given-names>
						</name>
						<name>
							<surname>Scheibe</surname>
							<given-names>F.</given-names>
						</name>
						<name>
							<surname>Wang</surname>
							<given-names>F-W.</given-names>
						</name>
						<name>
							<surname>Smith</surname>
							<given-names>M.C</given-names>
						</name>
					</person-group>
					<article-title>The missing mechanical circuit element</article-title>
					<source>IEEE Circuits and Systems Magazine</source>
					<volume>9</volume>
					<issue>1</issue>
					<fpage>10</fpage>
					<lpage>26</lpage>
					<month>03</month>
					<year>2009</year>
					<pub-id pub-id-type="doi">10.1109/MCAS.2008.931738</pub-id>
				</element-citation>
			</ref>
			<ref id="B19">
				<mixed-citation>[19] Ma, R., Bi, K. and Hao, H., Inerter-based structural vibration control: A state-of-the-art review, Engineering Structures , 243, pp. 1-23, September 2021. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.engstruct.2021.112655">https://doi.org/10.1016/j.engstruct.2021.112655</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Ma</surname>
							<given-names>R.</given-names>
						</name>
						<name>
							<surname>Bi</surname>
							<given-names>K.</given-names>
						</name>
						<name>
							<surname>Hao</surname>
							<given-names>H</given-names>
						</name>
					</person-group>
					<article-title>Inerter-based structural vibration control: A state-of-the-art review</article-title>
					<source>Engineering Structures</source>
					<volume>243</volume>
					<fpage>1</fpage>
					<lpage>23</lpage>
					<month>09</month>
					<year>2021</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.engstruct.2021.112655">https://doi.org/10.1016/j.engstruct.2021.112655</ext-link>
				</element-citation>
			</ref>
			<ref id="B20">
				<mixed-citation>[20] Wagg, D.J., A review of the mechanical inerter: historical context, physical realisations and nonlinear applications, Nonlinear Dynamics, 104, pp. 13-34, September 2021. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s11071-021-06303-8">https://doi.org/10.1007/s11071-021-06303-8</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Wagg</surname>
							<given-names>D.J</given-names>
						</name>
					</person-group>
					<article-title>A review of the mechanical inerter: historical context, physical realisations and nonlinear applications</article-title>
					<source>Nonlinear Dynamics</source>
					<volume>104</volume>
					<fpage>13</fpage>
					<lpage>34</lpage>
					<month>09</month>
					<year>2021</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s11071-021-06303-8">https://doi.org/10.1007/s11071-021-06303-8</ext-link>
				</element-citation>
			</ref>
			<ref id="B21">
				<mixed-citation>[21] Carrella, A., Brennan, M.J., Waters, T.P. and Lopes Jr., V., Force and displacement transmissibility of a nonlinear isolator with high-static-low-dynamic-stiffness, International Journal of Mechanical Sciences, 55(1), pp. 22-29, Febrary 2012. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/J.IJMECSCI.2011.11.012">https://doi.org/10.1016/J.IJMECSCI.2011.11.012</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Carrella</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Brennan</surname>
							<given-names>M.J.</given-names>
						</name>
						<name>
							<surname>Waters</surname>
							<given-names>T.P.</given-names>
						</name>
						<name>
							<surname>Lopes</surname>
							<given-names>V</given-names>
							<suffix>Jr.</suffix>
						</name>
					</person-group>
					<article-title>Force and displacement transmissibility of a nonlinear isolator with high-static-low-dynamic-stiffness</article-title>
					<source>International Journal of Mechanical Sciences</source>
					<volume>55</volume>
					<issue>1</issue>
					<fpage>22</fpage>
					<lpage>29</lpage>
					<month>02</month>
					<year>2012</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/J.IJMECSCI.2011.11.012">https://doi.org/10.1016/J.IJMECSCI.2011.11.012</ext-link>
				</element-citation>
			</ref>
			<ref id="B22">
				<mixed-citation>[22] Liu, C., Chen, L., Lee, H-P., Yang, Y. and Zhang, X., A review of the inerter and inerter-based vibration isolation: theory, devices, and applications, Journal of the Franklin Institute, 359(14), pp. 7677-7707, September 2022. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/J.JFRANKLIN.2022.07.030">https://doi.org/10.1016/J.JFRANKLIN.2022.07.030</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Liu</surname>
							<given-names>C.</given-names>
						</name>
						<name>
							<surname>Chen</surname>
							<given-names>L.</given-names>
						</name>
						<name>
							<surname>Lee</surname>
							<given-names>H-P.</given-names>
						</name>
						<name>
							<surname>Yang</surname>
							<given-names>Y.</given-names>
						</name>
						<name>
							<surname>Zhang</surname>
							<given-names>X</given-names>
						</name>
					</person-group>
					<article-title>A review of the inerter and inerter-based vibration isolation: theory, devices, and applications</article-title>
					<source>Journal of the Franklin Institute</source>
					<volume>359</volume>
					<issue>14</issue>
					<fpage>7677</fpage>
					<lpage>7707</lpage>
					<month>09</month>
					<year>2022</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/J.JFRANKLIN.2022.07.030">https://doi.org/10.1016/J.JFRANKLIN.2022.07.030</ext-link>
				</element-citation>
			</ref>
			<ref id="B23">
				<mixed-citation>[23] Marian, L. and Giaralis, A., Optimal design of a novel tuned mass-damper-inerter (TMDI) passive vibration control configuration for stochastically support-excited structural systems, Probabilistic Engineering Mechanics, 38, pp. 156-164, October 2014. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.probengmech.2014.03.007">https://doi.org/10.1016/j.probengmech.2014.03.007</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Marian</surname>
							<given-names>L.</given-names>
						</name>
						<name>
							<surname>Giaralis</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<article-title>Optimal design of a novel tuned mass-damper-inerter (TMDI) passive vibration control configuration for stochastically support-excited structural systems</article-title>
					<source>Probabilistic Engineering Mechanics</source>
					<volume>38</volume>
					<fpage>156</fpage>
					<lpage>164</lpage>
					<month>10</month>
					<year>2014</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.probengmech.2014.03.007">https://doi.org/10.1016/j.probengmech.2014.03.007</ext-link>
				</element-citation>
			</ref>
			<ref id="B24">
				<mixed-citation>[24] Xiuchang, H., Zhiwei, S. and Hongxing, H., Optimal parameters for dynamic vibration absorber with negative stiffness in controlling force transmission to a rigid foundation, International Journal of Mechanical Sciences , 152, pp. 88-98, March 2019. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.ijmecsci.2018.12.033">https://doi.org/10.1016/j.ijmecsci.2018.12.033</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Xiuchang</surname>
							<given-names>H.</given-names>
						</name>
						<name>
							<surname>Zhiwei</surname>
							<given-names>S.</given-names>
						</name>
						<name>
							<surname>Hongxing</surname>
							<given-names>H</given-names>
						</name>
					</person-group>
					<article-title>Optimal parameters for dynamic vibration absorber with negative stiffness in controlling force transmission to a rigid foundation</article-title>
					<source>International Journal of Mechanical Sciences</source>
					<volume>152</volume>
					<fpage>88</fpage>
					<lpage>98</lpage>
					<month>03</month>
					<year>2019</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.ijmecsci.2018.12.033">https://doi.org/10.1016/j.ijmecsci.2018.12.033</ext-link>
				</element-citation>
			</ref>
			<ref id="B25">
				<mixed-citation>[25] Barredo, E., López-Rojas, G., Mayén, J. and Flores-Hernández, A.A., Innovative negative-stiffness inerter-based mechanical networks, International Journal of Mechanical Sciences , 205, pp. 1-16, 2021. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/J.IJMECSCI.2021.106597">https://doi.org/10.1016/J.IJMECSCI.2021.106597</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Barredo</surname>
							<given-names>E.</given-names>
						</name>
						<name>
							<surname>López-Rojas</surname>
							<given-names>G.</given-names>
						</name>
						<name>
							<surname>Mayén</surname>
							<given-names>J.</given-names>
						</name>
						<name>
							<surname>Flores-Hernández</surname>
							<given-names>A.A</given-names>
						</name>
					</person-group>
					<article-title>Innovative negative-stiffness inerter-based mechanical networks</article-title>
					<source>International Journal of Mechanical Sciences</source>
					<volume>205</volume>
					<fpage>1</fpage>
					<lpage>16</lpage>
					<year>2021</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/J.IJMECSCI.2021.106597">https://doi.org/10.1016/J.IJMECSCI.2021.106597</ext-link>
				</element-citation>
			</ref>
			<ref id="B26">
				<mixed-citation>[26] Barredo, E., Blanco, A., Colín, J., Penagos, V.M., Abúndez, A., Vela, L.G., Meza, V., Cruz, R.H. and Mayén, J., Closed-form solutions for the optimal design of inerter-based dynamic vibration absorbers, International Journal of Mechanical Sciences , 144, pp. 41-53, August 2018. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.ijmecsci.2018.05.025">https://doi.org/10.1016/j.ijmecsci.2018.05.025</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Barredo</surname>
							<given-names>E.</given-names>
						</name>
						<name>
							<surname>Blanco</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Colín</surname>
							<given-names>J.</given-names>
						</name>
						<name>
							<surname>Penagos</surname>
							<given-names>V.M.</given-names>
						</name>
						<name>
							<surname>Abúndez</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Vela</surname>
							<given-names>L.G.</given-names>
						</name>
						<name>
							<surname>Meza</surname>
							<given-names>V.</given-names>
						</name>
						<name>
							<surname>Cruz</surname>
							<given-names>R.H.</given-names>
						</name>
						<name>
							<surname>Mayén</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<article-title>Closed-form solutions for the optimal design of inerter-based dynamic vibration absorbers</article-title>
					<source>International Journal of Mechanical Sciences</source>
					<volume>144</volume>
					<fpage>41</fpage>
					<lpage>53</lpage>
					<month>08</month>
					<year>2018</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.ijmecsci.2018.05.025">https://doi.org/10.1016/j.ijmecsci.2018.05.025</ext-link>
				</element-citation>
			</ref>
			<ref id="B27">
				<mixed-citation>[27] Hu, Y., Chen, M-Q., Shu, Z. and Huang, L., Analysis and optimisation for inerter-based isolators via fixed-point theory and algebraic solution, Journal of Sound and Vibration , 346, pp. 17-36, June 2015. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jsv.2015.02.041">https://doi.org/10.1016/j.jsv.2015.02.041</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Hu</surname>
							<given-names>Y.</given-names>
						</name>
						<name>
							<surname>Chen</surname>
							<given-names>M-Q.</given-names>
						</name>
						<name>
							<surname>Shu</surname>
							<given-names>Z.</given-names>
						</name>
						<name>
							<surname>Huang</surname>
							<given-names>L</given-names>
						</name>
					</person-group>
					<article-title>Analysis and optimisation for inerter-based isolators via fixed-point theory and algebraic solution</article-title>
					<source>Journal of Sound and Vibration</source>
					<volume>346</volume>
					<fpage>17</fpage>
					<lpage>36</lpage>
					<month>06</month>
					<year>2015</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jsv.2015.02.041">https://doi.org/10.1016/j.jsv.2015.02.041</ext-link>
				</element-citation>
			</ref>
			<ref id="B28">
				<mixed-citation>[28] Krenk, S., Frequency analysis of the tuned mass damper, J. Appl. Mech., 72(6), pp. 936-942, 2005. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.2062867">https://doi.org/10.1115/1.2062867</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Krenk</surname>
							<given-names>S</given-names>
						</name>
					</person-group>
					<article-title>Frequency analysis of the tuned mass damper</article-title>
					<source>J. Appl. Mech</source>
					<volume>72</volume>
					<issue>6</issue>
					<fpage>936</fpage>
					<lpage>942</lpage>
					<year>2005</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.2062867">https://doi.org/10.1115/1.2062867</ext-link>
				</element-citation>
			</ref>
			<ref id="B29">
				<mixed-citation>[29] Asami, T., Nishihara, O. and Baz, A.M., Analytical solutions to H ∞ and 𝐇 𝟐 optimization of dynamic vibration absorbers attached to damped linear systems, Journal of Vibration and Acoustics , 124(2), pp. 284-295, March 2002. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.1456458">https://doi.org/10.1115/1.1456458</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Asami</surname>
							<given-names>T.</given-names>
						</name>
						<name>
							<surname>Nishihara</surname>
							<given-names>O.</given-names>
						</name>
						<name>
							<surname>Baz</surname>
							<given-names>A.M</given-names>
						</name>
					</person-group>
					<article-title>Analytical solutions to H ∞ and 𝐇 𝟐 optimization of dynamic vibration absorbers attached to damped linear systems</article-title>
					<source>Journal of Vibration and Acoustics</source>
					<volume>124</volume>
					<issue>2</issue>
					<fpage>284</fpage>
					<lpage>295</lpage>
					<month>03</month>
					<year>2002</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.1456458">https://doi.org/10.1115/1.1456458</ext-link>
				</element-citation>
			</ref>
			<ref id="B30">
				<mixed-citation>[30] Nishihara, O. and Asami, T., Closed-form solutions to the exact optimizations of dynamic vibration absorbers (minimizations of the maximum amplitude magnification factors), Journal of Vibration and Acoustics , 124(4), pp. 576-582, September 2002. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.1500335">https://doi.org/10.1115/1.1500335</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Nishihara</surname>
							<given-names>O.</given-names>
						</name>
						<name>
							<surname>Asami</surname>
							<given-names>T</given-names>
						</name>
					</person-group>
					<article-title>Closed-form solutions to the exact optimizations of dynamic vibration absorbers (minimizations of the maximum amplitude magnification factors)</article-title>
					<source>Journal of Vibration and Acoustics</source>
					<volume>124</volume>
					<issue>4</issue>
					<fpage>576</fpage>
					<lpage>582</lpage>
					<month>09</month>
					<year>2002</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.1500335">https://doi.org/10.1115/1.1500335</ext-link>
				</element-citation>
			</ref>
			<ref id="B31">
				<mixed-citation>[31] Hu, Y. and Chen, M.Q., Performance evaluation for inerter-based dynamic vibration absorbers, International Journal of Mechanical Sciences , 99, pp. 297-307, August 2015. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.ijmecsci.2015.06.003">https://doi.org/10.1016/j.ijmecsci.2015.06.003</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Hu</surname>
							<given-names>Y.</given-names>
						</name>
						<name>
							<surname>Chen</surname>
							<given-names>M.Q</given-names>
						</name>
					</person-group>
					<article-title>Performance evaluation for inerter-based dynamic vibration absorbers</article-title>
					<source>International Journal of Mechanical Sciences</source>
					<volume>99</volume>
					<fpage>297</fpage>
					<lpage>307</lpage>
					<month>08</month>
					<year>2015</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.ijmecsci.2015.06.003">https://doi.org/10.1016/j.ijmecsci.2015.06.003</ext-link>
				</element-citation>
			</ref>
			<ref id="B32">
				<mixed-citation>[32] Asami, T., Mizukawa, Y. and Ise, T., Optimal design of double-mass dynamic vibration absorbers minimizing the mobility transfer function, Journal of Vibration and Acoustics , 140(6), pp. 1-14, June 2018. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.4040229">https://doi.org/10.1115/1.4040229</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Asami</surname>
							<given-names>T.</given-names>
						</name>
						<name>
							<surname>Mizukawa</surname>
							<given-names>Y.</given-names>
						</name>
						<name>
							<surname>Ise</surname>
							<given-names>T</given-names>
						</name>
					</person-group>
					<article-title>Optimal design of double-mass dynamic vibration absorbers minimizing the mobility transfer function</article-title>
					<source>Journal of Vibration and Acoustics</source>
					<volume>140</volume>
					<issue>6</issue>
					<fpage>1</fpage>
					<lpage>14</lpage>
					<month>06</month>
					<year>2018</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1115/1.4040229">https://doi.org/10.1115/1.4040229</ext-link>
				</element-citation>
			</ref>
			<ref id="B33">
				<mixed-citation>[33] Javidialesaadi, A. and Wierschem, M.E., Optimal design of rotational inertial double tuned mass dampers under random excitation, Engineering Structures , 165, pp. 412-421, June 2018. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.engstruct.2018.03.033">https://doi.org/10.1016/j.engstruct.2018.03.033</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Javidialesaadi</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Wierschem</surname>
							<given-names>M.E</given-names>
						</name>
					</person-group>
					<article-title>Optimal design of rotational inertial double tuned mass dampers under random excitation</article-title>
					<source>Engineering Structures</source>
					<volume>165</volume>
					<fpage>412</fpage>
					<lpage>421</lpage>
					<month>06</month>
					<year>2018</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.engstruct.2018.03.033">https://doi.org/10.1016/j.engstruct.2018.03.033</ext-link>
				</element-citation>
			</ref>
			<ref id="B34">
				<mixed-citation>[34] F.B.T.A. Doyle, J., Feedback Control Theory, Dover Publications, 1990. </mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>F.B.T.A. Doyle</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<source>Feedback Control Theory</source>
					<publisher-name>Dover Publications</publisher-name>
					<year>1990</year>
				</element-citation>
			</ref>
			<ref id="B35">
				<mixed-citation>[35] Kreyszig, E., Residue integration method, de Advanced Engineering Mathematics, Willey, 2011, pp. 719-735.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Kreyszig</surname>
							<given-names>E</given-names>
						</name>
					</person-group>
					<source>Residue integration method, de Advanced Engineering Mathematics</source>
					<publisher-name>Willey</publisher-name>
					<year>2011</year>
					<fpage>719</fpage>
					<lpage>735</lpage>
				</element-citation>
			</ref>
			<ref id="B36">
				<mixed-citation>[36] Hu, Y., Chen, M.Q. and Shu, Z., Passive vehicle suspensions employing inerters with multiple performance requirements, Journal of Sound and Vibration , 333(8), pp. 2212-2225, pril 2014. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jsv.2013.12.016">https://doi.org/10.1016/j.jsv.2013.12.016</ext-link>. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Hu</surname>
							<given-names>Y.</given-names>
						</name>
						<name>
							<surname>Chen</surname>
							<given-names>M.Q.</given-names>
						</name>
						<name>
							<surname>Shu</surname>
							<given-names>Z</given-names>
						</name>
					</person-group>
					<article-title>Passive vehicle suspensions employing inerters with multiple performance requirements</article-title>
					<source>Journal of Sound and Vibration</source>
					<volume>333</volume>
					<issue>8</issue>
					<fpage>2212</fpage>
					<lpage>2225</lpage>
					<month>04</month>
					<year>2014</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jsv.2013.12.016">https://doi.org/10.1016/j.jsv.2013.12.016</ext-link>
				</element-citation>
			</ref>
		</ref-list>
		<fn-group>
			<fn fn-type="other" id="fn0">
				<label>How to cite:</label>
				<p> Barredo, E., Mazón-Valadez,C., Mendoza-Larios, J.G. and Maldonado-Bravo, I.A., Rotational inertia-based tuned-mass-damper for controlling force transmission. DYNA, 90(225), pp. 131-139, January - March, 2023.</p>
			</fn>
		</fn-group>
		<fn-group>
			<fn fn-type="other" id="fn1">
				<label>E. Barredo,</label>
				<p> got a PhD in Mechanical Engineering Sciences from the National Center for Research and Technological Development (CENIDET), Mexico. He currently works as a full-time professor at the Technological University of the Mixteca (UTM), in Oaxaca, Mexico. Dr. Barredo is a member of both National System of Researchers (SNI) and PRODEP. His areas of interests are passive random vibration control based on inerter devices, energy harvesting systems, nonlinear optimization, among other areas. ORCID: 0000-0002-0180-4874.</p>
			</fn>
			<fn fn-type="other" id="fn2">
				<label>C. Mazón-Valadez,</label>
				<p> got a MSc. in Mechanical Engineering and is currently enrolled in the doctoral program in Sciences in Mechanical Engineering at TecNM/CENIDET, Mexico. His area of interest is passive vibration control using negative stiffness damper technology mixed with inerter-based mechanical networks. ORCID: 0000-0001-7989-6935.</p>
			</fn>
			<fn fn-type="other" id="fn3">
				<label>J.G. Mendoza-Larios,</label>
				<p> got a PhD. in Mechanical Engineering Sciences from the National Center for Research and Technological Development (CENIDET), Mexico. He has the desirable profile distinction from PRODEP and has co-supervised three master theses and supervised one bachelor thesis. He is a full-time professor at the Technological University of the Mixteca (UTM), Mexico, where he cultivates the research lines of Rotodynamics and Passive Vibration Control based on inerter devices. ORCID: 0000-0002-2878-2476.</p>
			</fn>
			<fn fn-type="other" id="fn4">
				<label>I.A. Maldonado-Bravo,</label>
				<p> got a MSc. in Mechanical Engineering Sciences from TecNM/CENIDET, Mexico. His area of interest is passive vibration control in mechanical structures such as isolated base buildings, using high-performance non-traditional inerter-based dynamic vibration absorbers. ORCID: 0000-0001-9777-2119.</p>
			</fn>
		</fn-group>
		<app-group>
			<app id="app1">
				<label>Appendix A. Dimensionless functions / for i = 1,..4.</label>
				<p>
					<disp-formula id="e103">
						<graphic xlink:href="2346-2183-dyna-90-225-131-e103.jpg"/>
					</disp-formula>
				</p>
			</app>
		</app-group>
	</back>
</article>