<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article
  PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article article-type="research-article" dtd-version="1.1" specific-use="sps-1.9" xml:lang="en" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
	<front>
		<journal-meta>
			<journal-id journal-id-type="publisher-id">iei</journal-id>
			<journal-title-group>
				<journal-title>Ingeniería e Investigación</journal-title>
				<abbrev-journal-title abbrev-type="publisher">Ing. Investig.</abbrev-journal-title>
			</journal-title-group>
			<issn pub-type="ppub">0120-5609</issn>
			<publisher>
				<publisher-name>Facultad de Ingeniería, Universidad Nacional de Colombia.</publisher-name>
			</publisher>
		</journal-meta>
		<article-meta>
			<article-id pub-id-type="doi">10.15446/ing.investig.v39n1.73638</article-id>
			<article-categories>
				<subj-group subj-group-type="heading">
					<subject>Original articles</subject>
				</subj-group>
			</article-categories>
			<title-group>
				<article-title>Modeling and simulation for mechanical behavior of modified biocomposite for scaffold application</article-title>
				<trans-title-group xml:lang="es">
					<trans-title>Modelado y simulación para el comportamiento mecánico de un biocompuesto modificado para la aplicación de andamios</trans-title>
				</trans-title-group>
			</title-group>
			<contrib-group>
				<contrib contrib-type="author">
					<name>
						<surname>Kashan</surname>
						<given-names>Jenan S.</given-names>
					</name>
					<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<name>
						<surname>Ali</surname>
						<given-names>Saad M</given-names>
					</name>
					<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
				</contrib>
			</contrib-group>
			<aff id="aff1">
				<label>1</label>
				<institution content-type="original"> B. and M.Sc. in Production Engineering and Metallurgy, University of Technology, Baghdad, Iraq. Ph.D. in Biomaterials, University of Technology, Iraq and SPEME University of Leeds U.K. Affiliation: Full-time Assistant Professor and Scientific Assistant of the Head of Biomedical Engineering Department, University of Technology, Iraq. E-mail: 70010@uotechnology.edu.iq. </institution>
				<institution content-type="orgdiv1">Head of Biomedical Engineering Department</institution>
				<institution content-type="orgname">University of Technology</institution>
				<country country="IQ">Iraq</country>
				<email>70010@uotechnology.edu.iq</email>
			</aff>
			<aff id="aff2">
				<label>2</label>
				<institution content-type="original"> B. in Production Engineering and Metallurgy, University of Technology, Iraq, M.Sc. Degree in Industrial Engineering, University of Baghdad, Iraq. Ph.D. Degree in Applied Mechanical Engineering, University of Technology, Iraq. Affiliation: Full-time Lecturer and Official Scientific and Cultural Division of Biomedical Engineering Department, University of Technology, Iraq. E-mail: 30249@uotechnology.edu.iq. </institution>
				<institution content-type="orgdiv1">Official Scientific and Cultural Division of Biomedical Engineering Department</institution>
				<institution content-type="orgname">University of Technology</institution>
				<country country="IQ">Iraq</country>
				<email>30249@uotechnology.edu.iq</email>
			</aff>
			<pub-date pub-type="epub" publication-format="electronic">
				<day>05</day>
				<month>11</month>
				<year>2019</year>
			</pub-date>
			<pub-date date-type="collection" publication-format="electronic">
				<season>Jan-Apr</season>
				<year>2019</year>
			</pub-date>
			<volume>39</volume>
			<issue>1</issue>
			<fpage>63</fpage>
			<lpage>75</lpage>
			<history>
				<date date-type="received">
					<day>22</day>
					<month>07</month>
					<year>2018</year>
				</date>
				<date date-type="accepted">
					<day>01</day>
					<month>04</month>
					<year>2019</year>
				</date>
			</history>
			<permissions>
				<license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/" xml:lang="en">
					<license-p>This is an open-access article distributed under the terms of the Creative Commons Attribution License</license-p>
				</license>
			</permissions>
			<abstract>
				<title>ABSTRACT</title>
				<p>Bones in the human body are a natural composite material that can be fractured due to impact stress and excessive loads. Human bones become less dense and strong when age increases, thereby they become more susceptible to fracture. The present work aims to study the effect of adding nano-ceramic particles on the mechanical properties to fabricate four types of hybrids of Titanium dioxide (TiO<sub>2</sub>) and Alumina (Al<sub>2</sub>O<sub>3</sub>) reinforced polyetheretherketone (PEEK) biocomposites. The objective of this study is to develop and improve the biomechanical properties of the fabricated biomaterials to withstand the loads of the daily human activities. Modeling and analysis of femur bone biomechanics were implemented by using the SOLIDWORKS 17.0 and the finite element ANSYS 15.0 software programs. The response surface methodology (RSM) technique and the Design Expert 11.0 software program were used to improve and verify the results of biomechanical performance of the fabricated biocomposites. From the current research results, it was deduce that the maximum equivalent (von-Misses) and shear stresses on the modeled femur bone are 1 20,93 and 60,80 MPa. The tensile for modeling the fabricated 20 vol.% TiO<sub>2</sub>/5 vol. % Al<sub>2</sub>O<sub>3</sub>/PEEK biocomposite material is higher than the one of natural femur bone by 10%. The maximum strain energy and the maximum equivalent elastic strain were reduced by 20% and 26,09%, respectively. The stress safety factor values increased in 5,81 %, and the fatigue life for the fabricated biocomposite is more than 40,43 %, when compared with natural femur bone material.</p>
			</abstract>
			<trans-abstract xml:lang="es">
				<title>RESUMEN</title>
				<p>Los huesos en el cuerpo humano son un material compuesto natural que puede fracturarse debido a la tensión de impacto y cargas excesivas. Los huesos humanos pierden densidad y fuerza al aumentar la edad, por lo que se vuelven más susceptibles a las fracturas. En el presente trabajo, se ha estudiado el efecto de la adición de partículas de nanocerámica en las propiedades mecánicas para fabricar cuatro tipos de híbridos de biocompuestos de polieteretercetona reforzada con dióxido de titanio (TiO<sub>2</sub>) y alúmina (Al<sub>2</sub>O<sub>3</sub>). El objetivo de este estudio es desarrollar y mejorar las propiedades biomecánicas de los biomateriales fabricados para soportar las cargas de las actividades humanas diarias. El modelado y análisis de la biomecánica ósea del fémur se implementó utilizando los programas de software SOLIDWORKS 17.0 y de elementos finitos ANSYS 15.0. La técnica de metodología de superficie de respuesta (RSM) y el programa de software Design Expert 11.0 se utilizaron para mejorar y verificar los resultados de las propiedades de rendimiento biomecánico de los biocompuestos fabricados. Los principales resultados de la investigación actual deducen que el máximo equivalente (von-Misses) y las tensiones de cizallamiento en el hueso del fémur modelado son 120,93 y 60,80 MPa. La tensión para modelar el fabricado es 20 vol. % TiO2/5 vol. El material biocompuesto % Al<sub>2</sub>O<sub>3</sub>/PEEK es más alto que el del hueso del fémur natural en un 10 %. La energía de tensión máxima y la máxima tensión elástica equivalente se redujeron en un 20 % y en un 26,09 %, respectivamente. Los valores del factor de seguridad de estrés aumentaron en un 5,81 %, y la vida de fatiga del biocompuesto fabricado es superior al 40,43 % en comparación con el material del hueso del fémur natural.</p>
			</trans-abstract>
			<kwd-group xml:lang="en">
				<title>Keywords:</title>
				<kwd>Femur bone replacement</kwd>
				<kwd>Nano PEEK</kwd>
				<kwd>Titanium Oxide</kwd>
				<kwd>Nano alumina</kwd>
				<kwd>Biocomposite</kwd>
				<kwd>RSM</kwd>
				<kwd>ANSYS modeling</kwd>
				<kwd>Femur bone fatigue life</kwd>
			</kwd-group>
			<kwd-group xml:lang="es">
				<title>Palabras clave:</title>
				<kwd>Reemplazo del hueso del fémur</kwd>
				<kwd>Nano PEEK</kwd>
				<kwd>Óxido de titanio</kwd>
				<kwd>Nano alúmina</kwd>
				<kwd>Biocompuesto</kwd>
				<kwd>RSM</kwd>
				<kwd>ANSYS modelado</kwd>
				<kwd>vida de fatiga ósea del fémur</kwd>
			</kwd-group>
			<counts>
				<fig-count count="11"/>
				<table-count count="8"/>
				<equation-count count="7"/>
				<ref-count count="33"/>
				<page-count count="13"/>
			</counts>
		</article-meta>
	</front>
	<body>
		<sec sec-type="intro">
			<title>Introduction</title>
			<p>Bones are natural composite living tissues supporting the softer parts of the human body (Maharaja <italic>et al.,</italic> 2013). They are approximately 60 % inorganic on a weight basis, 30 % organic, and 10 % water (<xref ref-type="bibr" rid="B13">Keaveny, Morgan and Yeh, 2004</xref>). Femur bone is the longest, strongest and heaviest bone in the human body with a length that is almost 26 % of the person height and a mass of about 0,455 kg (<xref ref-type="bibr" rid="B21">Popa, Gherghina, Tudor and Tarnita, 2006</xref>; <xref ref-type="bibr" rid="B19">Mughal, Khawaja and Moatamedi, 2015</xref>). The durability of biomaterials for prosthesis and orthopedic implants are of critical importance, mainly fabricated by using various alloys and metals to achieve the sufficient strength covered by the polymers biomaterials (<xref ref-type="bibr" rid="B10">Dhanopia and Bhargava, 2016</xref>).</p>
			<p>Today the titanium, stainless steel, cobalt, chrome and zirconium are the most used biomaterials because of a favorable combination of corrosion resistance, mechanical properties and cost effectiveness (<xref ref-type="bibr" rid="B27">Shireesha, Ramana and Rao, 2013</xref>; <xref ref-type="bibr" rid="B9">Das and Sarangi, 2014</xref>). For artificial femur materials, different ceramic materials like alumina (Al<sub>2</sub>O<sub>3</sub>), hydroxyapatite, zirconia (ZrO<sub>2</sub>), Ti6Al4V and Al<sub>2</sub>O<sub>3</sub>/Al FGM are widely researched for implant applications due to their good biocompatibility (<xref ref-type="bibr" rid="B1">Ahmed, Rahman and Adhikary, 2013</xref>; <xref ref-type="bibr" rid="B23">Reddy et al., 2016</xref>).</p>
			<p>Different synthetic hybrid biocompatible polymer-based matrices materials like polyethylene (PE), polyether ether ketone (PEEK), hydroxyapatite (HA), and poly methyl methacrylate (PMMA) are being used for bone scaffolds for potential load-bearing bone replacement and other biomaterial applications due to their durability, low cost, less weight, simple manufacturing, high strength and corrosion resistance. These biocomposites have also the advantages of high strength to weight-ratio, besides high specific modulus and superior fracture toughness (<xref ref-type="bibr" rid="B3">Bernhardt, Lode, Peters and Gelinsky, 2011</xref>; <xref ref-type="bibr" rid="B15">Lee et al., 2012</xref>; <xref ref-type="bibr" rid="B17">Mohammed et al., 2013</xref>; <xref ref-type="bibr" rid="B20">Nautiyal, Nain and Kumar, 2014</xref>).</p>
			<p>The polyether ether ketone (PEEK) thermoplastic is an organic colorless thermoplastic polymer with its own high mechanical, thermal properties and chemical stability. The high biocompatibility of titanium dioxide (TiO<sub>2</sub>) has a wide range of applications, for orthopedic biomaterials. The bioinert ceramic aluminum oxide (Al<sub>2</sub>O<sub>3</sub>) is a chemical compound of aluminum and oxygen with high abrasion resistance and high hardness. It is commonly called alumina. Due to its high melting point, Al<sub>2</sub>O<sub>3</sub> is a refractory material that naturally appears in a crystalline polymorphic phase a-Al<sub>2</sub>O<sub>3</sub>.</p>
			<p>Long bones have different mechanical properties in the transverse and longitudinal directions, while loaded along different directions (<xref ref-type="bibr" rid="B29">Toth-Tascau, Rusu and Toader, 2010</xref>). The mechanical properties and structure understanding of natural bone is vital for developing new biomaterial bone implants. The mean fluctuating loads on the hip joint in general are expected to increase the body weight three to five times during jogging and jumping, depending on the human activities such as running, standing, sitting, staircase climbing, etc. (<xref ref-type="bibr" rid="B17">Mohammed et al., 2013</xref>).</p>
			<p>Bone remodeling is a complex process that involves interactions between mechanical, biochemical, and mechanic-biological parameters to explain the relationship between mechanical forces and bone structure (<xref ref-type="bibr" rid="B4">Bougherara, Klika, Marsik, Marik and Yahia, 2010</xref>; <xref ref-type="bibr" rid="B31">Yousif and Aziz, 2012</xref>). Different efforts were made to analyze the stresses experienced by the human femur and CAD models were developed (<xref ref-type="bibr" rid="B19">Mughal et al., 2015</xref>). The 3D models of human femur were constructed by reverse engineering method and using finite element model under single, expanded loads (<xref ref-type="bibr" rid="B32">Zakiuddin, Khan, Roshni and Hinge, 2016</xref>).</p>
			<p>During normal activities, the femur bone is subjected to tensile, compressive, and shear stresses. Shear stress magnitudes are relatively small, but can become significant in long bones subjected to torsion. Bone will fail along the weakest plane and this fracture plane coincides with maximum tensile stresses (<xref ref-type="bibr" rid="B30">Turner, Wang and Burr, 2001</xref>). The literature show that there is still a lack of predictive models despite the progress in bone remodeling and simulation using the finite element (FE) method (<xref ref-type="bibr" rid="B11">Hambli, 2014</xref>). The use of specific finite element models in orthopedic biomechanics still represents a challenge in the prediction of fracture risk and stress-state induced in bones under various loading conditions (<xref ref-type="bibr" rid="B24">Schileo, Taddei, Malandrino, Cristofolini, and Vicecont, 2007</xref>).</p>
			<p>A limited number of researchers have worked on 3D modeling of the femur bone. In biomechanics, specific problems of the FEM are still difficult to model <italic>(</italic><xref ref-type="bibr" rid="B31">Yousif and Aziz, 2012</xref>; <xref ref-type="bibr" rid="B20">Nautiyal et al., 2014</xref>). Research done by Nautiyal <italic>et al.</italic> (2014) has explored the replacement of defective bone for a perfect design and comfort of the patient including rotation, i.e. ease for changing direction, and weight for maximizing comfort, balance and speed (Nautiyal <italic>et al.,</italic> 2014).</p>
			<p>In the present work, the remarkable and promising properties of Titanium dioxide (TiO2) and Alumina (Al<sub>2</sub>O<sub>3</sub>) nano-ceramic particles were added for reinforcement of polyetheretherketone (PEEK) matrices to fabricate four types of hybrid bio-composites by using the powder metallurgy process. An attempt has been made to develop and study the effect of adding these nano-ceramic particles on the mechanical properties and inflammation behavior using animal model for the fabricated bio-composites systems. The aim of this study was to improve the biomechanical properties of these fabricated biomaterials to meet the wide demands for orthopedic application, particularly in bone and hip joint replacement.</p>
			<p>The objectives of this study also included finding the best bio-material fatigue life and stress factor of safety to withstand the daily human normal walking, running and jumping activities loads. A three-dimensional femur bone geometry was initiated by using SOLIDWORKS 17.0 and it was modeled and analyzed by using finite element ANSYS 15.0 software programs. The response surface methodology (RSM) technique and the Design Expert software program were used to improve and verify the results of biomechanical properties of the fabricated biocomposites.</p>
		</sec>
		<sec sec-type="methods">
			<title>Experimental Procedure</title>
			<p>Numerical analyses of biomaterial hard tissue are closely related to the selection of biomechanical properties and of biomaterials and implants (<xref ref-type="bibr" rid="B26">Sherekar and Pawar, 2013</xref>). In this study, four biocomposite materials were fabricated using a polymeric matrix of PEEK powder with an average particle size of 10 μm and a density of 1,3 g/cm<sup>3</sup>. The first material used was TiO<sub>2</sub> ceramic filler of 99,9 % purity, average particle size of 40 nm and particle density equal to 4,23 g/cm<sup>3</sup>. The second material used was Al<sub>2</sub>O<sub>3</sub> ceramic powder of 10 nm average particle size and a density of (3,890 g/cm<sup>2</sup>). The powders were mixed by using the micro powder ball mill mixing and grinding machine type YLK, rotated at 180 RPM for 12 h. Then, they were hot pressed at 180,190, and 200 °C and using a compounding pressure of 30, 60, and 90 MPa, respectively.</p>
			<p>The four mixed biocomposites were prepared for implants with different compositions with composites of 10 vol. % of TiO<sub>2</sub> and 90% PEEK, 20 vol.% of TO and 80% PEEK, 10 vol.% of TiO<sub>2</sub> with 5 vol.% of Al<sub>2</sub>O<sub>3</sub> and 85 % PEEK, and 20 vol. % TiO<sub>2</sub> with 5 vol. % of Al<sub>2</sub>O<sub>3</sub> and 75 % PEEK. The mechanical and physical properties of the PEEK, TiO<sub>2</sub> and Al<sub>2</sub>O<sub>3</sub> are presented in <xref ref-type="table" rid="t1">Table 1</xref>.</p>
			<p>
				<table-wrap id="t1">
					<label>Table 1</label>
					<caption>
						<title>Mechanical and physical properties of the PEEK, TiO<sub>2</sub> and Al2O3</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gt1.png"/>
					<table-wrap-foot>
						<fn id="TFN1">
							<p>Source: Authors from <xref ref-type="bibr" rid="B6">Burgal, Peeva, Marchetti and Livingston (2015)</xref>
							</p>
						</fn>
					</table-wrap-foot>
				</table-wrap>
			</p>
			<p>Then, the prepared biocomposites were compacted by using the hot-pressing powder metallurgical technique with an applied compression pressure of 50MPa under sintering temperatures of 370, 380, 390, and 400 °C. The fabrication process parameters with the experimentally obtained mechanical properties of the fabricated biocomposites and natural bones properties are given in <xref ref-type="table" rid="t2">Table 2</xref>.</p>
			<p>
				<table-wrap id="t2">
					<label>Table 2</label>
					<caption>
						<title>Mechanical properties obtained for the fabricated biocomposites and natural bones properties</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gt2.png"/>
					<table-wrap-foot>
						<fn id="TFN2">
							<p>((*) MIT, 2006); ((**) Carter, Caler, Spencler and Frankel, 2017); ((***) <xref ref-type="bibr" rid="B12">Ibrahim, Daud, Zain, Izzawati and Bajuri, 2017</xref>)</p>
						</fn>
						<fn id="TFN3">
							<p>Source: Authors</p>
						</fn>
					</table-wrap-foot>
				</table-wrap>
			</p>
			<p>For examining the implant biological reactivity of the highest mechanical properties of the fabricated biocomposite, i.e. 20 vol.% of TiO<sub>2</sub> with 5 vol.% of Al<sub>2</sub>O<sub>3</sub> and 75% of PEEK, <italic>in vivo</italic> tests were implemented with cylindrical shapes in four breed rabbits to study the implants inflammation behavior. X-Ray radiographical examinations were implemented in all animals after 2, 4, 6 and 8 weeks, using Shimadzu digital x-ray machine grid type 2016/CRX10.</p>
		</sec>
		<sec>
			<title>Modeling and Analyzing of Femur bone</title>
			<p>The longest bone in human body is the femur, which is subjected to maximum deformation and compressive stresses. Finding these deformation and stress concentrations zones is very important in the femur bone implant (<xref ref-type="bibr" rid="B2">Amalraju and Dawood, 2012</xref>). The biomechanical behavior research on the femur bone is a hard task, since it is a live part in constant change and very complicated in terms of material properties, geometry, porosity and density. Finite element analysis (FEA) is the most reliable method among all of them (<xref ref-type="bibr" rid="B28">Taheri et al., 2012</xref>; <xref ref-type="bibr" rid="B18">Mohd Sheikh, Ganorkar and Dehankar, 2016</xref>). By using finite element analysis with different simulations, the weak points of the femur can be known, thus helping in the design and biomaterial selection (<xref ref-type="bibr" rid="B33">Zhang, Wang, Yu and Zheng, 2017</xref>).</p>
			<p>In this work, the geometry of the human femur bone was implemented using the 3D Solidworks 17.0 software. The modeling dimensions of the bone were taken from a plastic copy of the adult bone. The modeling and analysis of human bone were done by using Ansys Workbench 15.7. The present bone model of the long femur was assumed to be homogeneous and isotropic. The suggested model for the real human bone was represented by two sections. The epiphysis part is made of spongy cancellous (trabecular) bone covered by a thin layer of compact trabecular bone. The bone model is also considered with two sections: the upper (epiphysis) edge part includes the head, neck and trochanters and the lower (diaphysis) edge is defined as the condyles (<xref ref-type="bibr" rid="B8">Dash, Kishor and Panda, 2013</xref>).</p>
			<p>For modeling the natural femur bone composite, the process for creating the outer cortical bone part and the inner trabecular-bone part of the femur was done after importing the 3D model by creating a new part and using the freeze commands in ANSYS workbench. Then, the femur bone will appear as a complete femur bone (one piece) as shown in <xref ref-type="fig" rid="f1">Figures 1</xref>a and b. The 3D finite element analysis (FEA) model of the femur bone was discretized by using a fine size volumetric meshing. To avoid unrealistic stress concentration points a mesh refinement was performed in the desired segments of the bone with higher gradients. The aim was to magnify the accuracy and ensure the quality of results, as shown in <xref ref-type="fig" rid="f1">Figure 1</xref>c for modeling the natural femur bone composite and 1d and 1e for modeling the fabricated femur biocomposite bone. The number of created nodes is 39 957 and 19 480 elements.</p>
			<p>
				<fig id="f1">
					<label>Figure 1</label>
					<caption>
						<title>Modeling of femur bone: (a) natural outer part as cortical bone part; (b) natural inner part as trabecular bone; (c) mesh refinement of the natural bone; (d) mesh refinement of the fabricated biocomposite bones; (e) the resulted mesh refinement of the bones; (f) mesh refinement of the fabricated biocomposite bones.</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gf1.png"/>
					<attrib>Source: Authors</attrib>
				</fig>
			</p>
			<p>In the present study, the stress analysis called multiphysics static structural analysis is used to determine the dynamic response of loads on the head of the femur during the hardest activity of the gait cycle (<xref ref-type="bibr" rid="B22">Qasim et al., 2016</xref>). The bone was analyzed for stresses/forces during running and jumping activities. The femur bone was considered as an inflexible and solid condition. The resulting loads at the hip joint contact for these complicated activities are applied on the femoral head contact area and the other end lower part surface of the bone, i.e. the lateral condyle installed by a fixed support (free clamped for all degrees of freedom).</p>
			<p>At walking activities with a speed of more than 5 km/h and during running and jumping activities, a longitudinal compressive load was simulated for an average adult male patient. Weight of 750 N was applied on the femoral head eccentrically and concentrically at the extremes with a maximum inclined angle of knee joint considered as a couple torque force (moment) of 10 N.mm applied normal to the long edge of the implant (<xref ref-type="bibr" rid="B29">Toth-Tascau et al., 2010</xref>; <xref ref-type="bibr" rid="B1">Ahmed et al., 2013</xref>). The applied loads components in -x, -y and -z directions are the human weight * cos 30° * tan 30°, weight * cos 30° * sin 30° and weight * cos 30° * cos 30°, respectively. The applied moment components were calculated in the same manner and directions using a moment value of 10 N.mm. The boundary conditions of the modeled femur bone are shown in <xref ref-type="fig" rid="f1">Figure 1</xref>f.</p>
		</sec>
		<sec sec-type="results|discussion">
			<title>Results and Discussion</title>
			<p>The main contribution of this study is to create a simulation model that can demonstrate the highest stresses, strains distribution and fatigue failure of the natural femur bone and for the fabricated nano-composites for bones replacements. The performance of the mechanical properties in the modeling results for the natural femur bone and all the fabricated biocomposites are given in <xref ref-type="table" rid="t3">Table 3</xref>.</p>
			<p>
				<table-wrap id="t3">
					<label>Table 3</label>
					<caption>
						<title>Results of the performance of mechanical properties for the natural femur bone and the fabricated biocomposite materials</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gt3.png"/>
					<table-wrap-foot>
						<fn id="TFN4">
							<p>Source: Authors</p>
						</fn>
					</table-wrap-foot>
				</table-wrap>
			</p>
			<p>The resulting maximum equivalent (von-Mises) and shear stresses for the applied force and moment on the modeled femur bone is 120,93 and 60,80 MPa, respectively, as shown in <xref ref-type="fig" rid="f2">Figures 2</xref>a and b. These stresses increased in the middle uniform part of the bone, where fractures are expected, as confirmed by most cases of injury and fractures in various accidents. Senthil Maharaj, Maheswaran and Vasanthanathan reported that the maximum equivalent stress is generated at the middle section of the femur. It reached 65,35 MPa in the study of Maharaja <italic>et al.</italic> (2013), while <xref ref-type="bibr" rid="B1">Ahmed et al. (2013)</xref> concluded that the von-Mises stress distributions on the surface of the implanted femur are 128,05 MPa in stance and 1 127,8 MPa in fall.</p>
			<p>
				<fig id="f2">
					<label>Figure 2</label>
					<caption>
						<title>(a) Maximum equivalent (von-Misses) stress on the modeled femur bone; (b) Maximum shear stress.</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gf2.png"/>
					<attrib>Source: Authors</attrib>
				</fig>
			</p>
			<p>In the present work, the experiments were designed using the response surface methodology (RSM) and the full factorial method (FFM). The results were analyzed using an analysis of variance (ANOVA) technique. <xref ref-type="table" rid="t4">Table 4</xref> presents the ANOVA analysis of the tensile strength resulting from changing the compact temperature and the density of the fabricated biocomposite materials. The F-value of 258,81 implies that the model is significant. The 3D graphs for the tensile strength of the fabricated biocomposite materials are shown in <xref ref-type="fig" rid="f3">Figure 3</xref>. These graphs show that the maximum tensile strength reached 220 MPa when modelling the fabricated 20 vol. % TiO<sub>2</sub>/5 vol. % Al<sub>2</sub>O<sub>3</sub>/PEEK biocomposite material.</p>
			<p>
				<table-wrap id="t4">
					<label>Table 4</label>
					<caption>
						<title>ANOVA analysis of the tensile strength for the fabricated biocomposite materials</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gt4.png"/>
					<table-wrap-foot>
						<fn id="TFN5">
							<p>* significant</p>
						</fn>
						<fn id="TFN6">
							<p>Source: Authors</p>
						</fn>
					</table-wrap-foot>
				</table-wrap>
			</p>
			<p>
				<fig id="f3">
					<label>Figure 3</label>
					<caption>
						<title>3D graphs for the tensile strength of the fabricated biocomposite materials.</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gf3.png"/>
					<attrib>Source: Authors</attrib>
				</fig>
			</p>
			<p>This value is higher than for natural femur bone by 10%. The tensile strength value increased with the compact temperature during the powder metallurgical process. The increase in the density also helped to obtain higher tensile strength values because it means an increase in the molecular bouncing of the crystal structure. Increasing the proportion of titanium dioxide nano-ceramic material to the base PEEK material also increased the durability, as these materials possess high mechanical properties such as the tensile strength, endurance limit and compressive strength. This strength increased considerably by increasing the alumina particle ratios because its endurance limit and fracture toughness improved significantly. This conclusion agrees with <xref ref-type="bibr" rid="B17">Mohammed et al. (2013)</xref>, whose study showed that the tensile strength of biocomposite materials increase with higher filler contents percentage of Al<sub>2</sub>O<sub>3</sub> and of TiO<sub>2</sub>.</p>
			<p>The external mechanical work causes the elastic deformation of the femur bone structure in daily human activities, as movement is transformed into internal strain energy. The bone failure occurs when the maximum shear strain energy component is equal to the corresponding value at the yield point in the tensile test. The ANOVA analysis of the internal strain energy of the fabricated biocomposite materials are given in <xref ref-type="table" rid="t5">Table 5</xref>. The F-value of 195,28 implies that the model is significant. The 3D graphs show that the strain energy values increased with the biomaterial density and vice versa, with the tensile strength, the elastic strain and compact temperature, as shown in <xref ref-type="fig" rid="f4">Figure 4</xref>.</p>
			<p>
				<table-wrap id="t5">
					<label>Table 5</label>
					<caption>
						<title>ANOVA analysis of the internal strain energy of the fabricated biocomposite materials</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gt5.png"/>
					<table-wrap-foot>
						<fn id="TFN7">
							<p>Source Authors</p>
						</fn>
					</table-wrap-foot>
				</table-wrap>
			</p>
			<p>
				<fig id="f4">
					<label><bold>Figure 4</bold></label>
					<caption>
						<title>3D graphs for the internal strain energy of the fabricated biocomposites materials. </title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gf4.png"/>
					<attrib>Source: Authors</attrib>
				</fig>
			</p>
			<p>These graphs show that the lower maximum strain energy values are due to external loadings for these complex states of stress systems. This was obtained with the model of the natural femur bone and the best fabricated biocomposite material (20% vol. TiO<sub>2</sub>/5% vol. Al<sub>2</sub>O<sub>3</sub>/PEEK) at the highest compact temperature of 400 °C. Strain energy values were equal to 15,61 and 13,01 m.J., as shown in <xref ref-type="fig" rid="f5">Figures 5</xref>a and b. The strain energy was reduced by 20 %, when compared with the natural femur bone material. This means that for this type of fabricated biocomposite material, the required value of the strain energy conversion into mechanical kinetic energy and the rising in the temperature generated is the lowest. This is in favor of patients who are fractured and injured and undergo partial repair or replacement of femur bone. For the same human weight, the maximum displacement that <xref ref-type="bibr" rid="B2">Amalraju et al. (2012)</xref> found was 0,0012 mm, and values of 0,0012 for Ti6Al4V and 0,0036 for Al<sub>2</sub>O<sub>3</sub>/Al FGM were reported by <xref ref-type="bibr" rid="B1">Ahmed et al. (2013)</xref>.</p>
			<p>
				<fig id="f5">
					<label>Figure 5</label>
					<caption>
						<title>(a) Maximum strain energy of the natural modeled femur bone; (b) for the fabricated (20% vol. TiO2/5 % vol. Al2O3/PEEK) biocomposite at compact temperature of 400 °C.</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gf5.png"/>
					<attrib>Source: Authors</attrib>
				</fig>
			</p>
			<p>ANOVA analysis of the equivalent elastic strain and the stress safety factor values for all the examined biomaterials are listed in <xref ref-type="table" rid="t6">Tables 6</xref> and <xref ref-type="table" rid="t7">7</xref>. The F-values of 185,14 and 252,14 imply that the models are significant. The 3D graphs show that the equivalent elastic values increased with the decrease in the biomaterial density and in compact temperature, as shown in <xref ref-type="fig" rid="f6">Figure 6</xref>. <xref ref-type="fig" rid="f7">Figure 7</xref> shows the 3D graphs of the stress safety factor values, which decreased with the increase in the biomaterial density and in compact temperature.</p>
			<p>
				<table-wrap id="t6">
					<label>Table 6</label>
					<caption>
						<title>ANOVA analysis of the equivalent elastic strain of the fabricated biocomposite materials</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gt6.png"/>
					<table-wrap-foot>
						<fn id="TFN8">
							<p>Source: Authors</p>
						</fn>
					</table-wrap-foot>
				</table-wrap>
			</p>
			<p>
				<table-wrap id="t7">
					<label>Table 7</label>
					<caption>
						<title>ANOVA analysis of the stress safety factor of the fabricated biocomposite materials</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gt7.png"/>
					<table-wrap-foot>
						<fn id="TFN9">
							<p>Source: Authors</p>
						</fn>
					</table-wrap-foot>
				</table-wrap>
			</p>
			<p>
				<fig id="f6">
					<label>Figure 6</label>
					<caption>
						<title>3D graphs for the equivalent elastic strain of the fabricated biocomposite materials.</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gf6.png">/</graphic>
					<attrib>Source: Authors</attrib>
				</fig>
			</p>
			<p>
				<fig id="f7">
					<label>Figure 7</label>
					<caption>
						<title>3D graphs for stress safety factor of the fabricated biocomposite materials.</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gf7.png">/</graphic>
					<attrib>Source: Authors</attrib>
				</fig>
			</p>
			<p>The maximum equivalent elastic strain and the stress safety factor values for the best fabricated (20 % vol. TiO<sub>2</sub>/5 % vol. Al<sub>2</sub>O<sub>3</sub>/PEEK) biocomposite material were obtained at compact temperature of 400 °C in the simulation model, resulting from the external loads applied on the femur. These values are the lowest of all types of the fabricated biocomposite materials and for all the compact temperatures used, reaching 0,0051 mm/mm and 1,82. These equivalent elastic strain and stress safety factor values are better than the values obtained for the modeled natural composite femur bone, which reached 0,0069 mm/mm and 1,72, by 26,09% and 5,81 %, as shown in <xref ref-type="fig" rid="f8">Figures 8</xref>a and b and <xref ref-type="fig" rid="f9">9</xref>a and b, respectively. These values are highly important for helping the patient's replaced femur bone to carry higher external loads and weights and withstand any sudden dynamic movement events, which are expected to occur within the daily activities of life.</p>
			<p>
				<fig id="f8">
					<label>Figure 8</label>
					<caption>
						<title>(a) Maximum equivalent elastic strain of the modeled natural femur bone; (b) for the fabricated biocomposite (20% vol. TiO<sub>2</sub>/5% vol. Al<sub>2</sub>O<sub>3</sub>/PEEK) at compact temperature of 400 °C.</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gf8.png">/</graphic>
					<attrib>Source: Authors</attrib>
				</fig>
			</p>
			<p>
				<fig id="f9">
					<label>Figure 9</label>
					<caption>
						<title>(a) Maximum stress safety factor of the modeled natural femur bone; (b) for the fabricated biocomposite (20% vol. TiO<sub>2</sub>/5% vol. Al<sub>2</sub>O<sub>3</sub>/PEEK) at compact temperature of 400 °C.</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gf9.png"/>
					<attrib>Source: Authors</attrib>
				</fig>
			</p>
			<p>To calculate the fatigue lives in cycles for the natural femur bone, all the four fabricated biocomposites at all compact temperatures are used. Firstly, endurance (S’<sub>e</sub>) should be calculated from the ultimate tensile stress (S<sub>ut</sub>) values limit by using the following equation (Shigley and Mischke, 2006):</p>
			<p>
				<disp-formula id="e1">
					<graphic xlink:href="0120-5609-iei-39-01-63-e1.png"/> The modified endurance limit (S) can be found as:</disp-formula>
			</p>
			<p>
				<disp-formula id="e2">
					<graphic xlink:href="0120-5609-iei-39-01-63-e2.png"/>
				</disp-formula>
			</p>
			<p>where the Surface Condition Factor (k<sub>a</sub>) for grinding surface is equal to:</p>
			<p>
				<disp-formula id="e3">
					<graphic xlink:href="0120-5609-iei-39-01-63-e3.png"/>
				</disp-formula>
			</p>
			<p>The size Factor (k<sub>b</sub>) for bending and torsion (assuming that the mean diameter of the femur bone is equal to 25 mm) is:</p>
			<p>
				<disp-formula id="e4">
					<graphic xlink:href="0120-5609-iei-39-01-63-e4.png"/>
				</disp-formula>
			</p>
			<p>The loading factor <italic>(k</italic>
 <sub>
 <italic>c</italic>
</sub> 
 <italic>)</italic> for bending and torsion is:</p>
			<p>
				<disp-formula id="e5">
					<graphic xlink:href="0120-5609-iei-39-01-63-e5.png"/>
				</disp-formula>
			</p>
			<p>The temperature factor for human life <italic>(k</italic>
 <sub>
 <italic>d</italic>
</sub> 
 <italic>)</italic> = 1. For 99 % reliability, the reliability factor corresponds to 8 % standard deviation of the endurance limit <italic>(k</italic>
 <sub>
 <italic>e</italic>
</sub> 
 <italic>)</italic> = 0, 82. The miscellaneous-effects factor <italic>(k</italic>
 <sub>
 <italic>f</italic>
</sub> 
 <italic>)</italic> = 1. Then, the modified endurance limit <italic>(S</italic>
 <sub>
 <italic>e</italic>
</sub> 
 <italic>)</italic> can be obtained by using equation (2). The fatigue life, i.e. the number of cycles to the failure (<italic>N</italic>) at a given fatigue stress (<italic>σ</italic>), is found as:</p>
			<p>
				<disp-formula id="e6">
					<graphic xlink:href="0120-5609-iei-39-01-63-e6.png"/>
				</disp-formula>
			</p>
			<p>where:</p>
			<p>
				<disp-formula id="e7">
					<graphic xlink:href="0120-5609-iei-39-01-63-e7.png"/>
				</disp-formula>
			</p>
			<p>The fatigue lives (σ) and the results of all the fabricated biocomposite materials were calculated for all fatigue stresses, as well as for the natural femur bone for all the stress rates, starting from the tensile strength to the endurance limit stress values with a difference of 5 MPa.</p>
			<p>These results with the mechanical properties obtained from the experimental tests, presented in <xref ref-type="table" rid="t2">Table 2</xref>, have been introduced in the engineering date of the ANSYS 15,7 software program.</p>
			<p>The ANOVA analyses of the values of fatigue life for the fabricated biomaterials are listed in <xref ref-type="table" rid="t8">Table 8</xref>. The model F-value of 227,69 implies that the model is significant. The 3D graphs show that the fatigue life values increased with the biomaterial density and compact temperature, as shown in <xref ref-type="fig" rid="f10">Figure 10</xref>. <xref ref-type="fig" rid="f11">Figure 11</xref> shows the maximum values of fatigue lives of the modeled natural femur bone and for the best result of the fabricated biocomposite (20% vol. TiO<sub>2</sub>/5% vol. Al<sub>2</sub>O<sub>3</sub>/PEEK) at compact temperature of400 <sup>°</sup>C, reaching 50,51 and 70,93 x 10<sup>6</sup> cycles, respectively.</p>
			<p>
				<table-wrap id="t8">
					<label>Table 8</label>
					<caption>
						<title>ANOVA analysis of the stress safety factor of the fabricated biocomposite materials</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gt8.png"/>
					<table-wrap-foot>
						<fn id="TFN10">
							<label><sup>*</sup></label>
							<p>significant </p>
						</fn>
						<fn id="TFN11">
							<p>Source: Authors</p>
						</fn>
					</table-wrap-foot>
				</table-wrap>
			</p>
			<p>
				<fig id="f10">
					<label>Figure 10</label>
					<caption>
						<title>3D graphs for stress safety factor of the fabricated biocomposite materials.</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gf10.png"/>
					<attrib>Source: Authors</attrib>
				</fig>
			</p>
			<p>
				<fig id="f11">
					<label>Figure 11</label>
					<caption>
						<title>(a) Maximum fatigue life of the modeled natural femur bone; (b) for the fabricated biocomposite (20% vol. TiO2/5 % vol. Al<sub>2</sub>O<sub>3</sub>/PEEK) at compact temperature of 400 °C.</title>
					</caption>
					<graphic xlink:href="0120-5609-iei-39-01-63-gf11.png"/>
					<attrib>Source: Authors</attrib>
				</fig>
			</p>
			<p>These results show that the fatigue life for the fabricated biocomposite is 40,43 % more than that of the natural femur bone life. These results give hope to bone fractures and osteoporosis patients to use successful biocomposite substances in the <italic>in vitro</italic> and <italic>in vivo</italic> tests with good durability, flexibility and a better life performance.</p>
		</sec>
		<sec sec-type="conclusions">
			<title>Conclusions</title>
			<p>The maximum equivalent (von-Misses) and shear stresses on the modeled femur bone are 120,93 and 60,80 MPa.</p>
			<p>The tensile strength increased with the compact temperature and the density. The maximum tensile strength reached 220 MPa when modeling the fabricated biocomposite of 20 vol. % TiO<sub>2</sub>/5 vol. % Al<sub>2</sub>O<sub>3</sub>/PEEK material. This value is higher than that for natural femur bone by 10%.</p>
			<p>The lower maximum strain energy values obtained with the modeled the natural femur bone and the best fabricated biocomposite (20% vol. TiO<sub>2</sub>/5 % vol. Al<sub>2</sub>O<sub>3</sub>/PEEK) at the highest compact temperature of 400 <sup>°</sup>C are equal to 15,61 and 13,01 m.J., respectively. The strain energy was reduced in 20%, when compared with natural femur bone material.</p>
			<p>The maximum equivalent elastic strain and the stress safety factor values for the best fabricated biocomposite (20 % vol. TiO<sub>2</sub>/5% vol. Al<sub>2</sub>O<sub>3</sub>/PEEK) at compact temperature of 400 <sup>°</sup> C reached 0,0051 mm/mm and 1,82, respectively. These equivalent elastic strains and these values are better than those obtained for the modeled natural femur bone composite by 26,09% and 5,81 %, respectively.</p>
			<p>The maximum values of fatigue lives for the modeled natural femur bone and for the best fatigue life result of the fabricated biocomposite (20% vol. TiO<sub>2</sub>/5% vol. Al<sub>2</sub>O<sub>3</sub>/PEEK) at compact temperature of 400 °C reached 50,51 and 70,93 x 10<sup>6</sup> cycles, respectively. These results show that the fatigue life for the fabricated biocomposite is 40,43 % more than that of the natural femur bone life.</p>
		</sec>
	</body>
	<back>
		<ref-list>
			<title>References</title>
			<ref id="B1">
				<mixed-citation>Ahmed, T., Rahman, M.Z. and Adhikary, D. (2013). Analysis of Al<sub>2</sub>O<sub>3</sub>/Al FGM as Biomaterial of Artificial Human Femoral Bone and Compare with Ti6Al4V Alloy through Computational Study. <italic>Global Journal of Researches in Engineering</italic>, 13(3), 1-8. Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://engineeringresearch.org/index.php/GJRE/article/view/811">https://engineeringresearch.org/index.php/GJRE/article/view/811</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Ahmed</surname>
							<given-names>T.</given-names>
						</name>
						<name>
							<surname>Rahman</surname>
							<given-names>M.Z.</given-names>
						</name>
						<name>
							<surname>Adhikary</surname>
							<given-names>D</given-names>
						</name>
					</person-group>
					<year>2013</year>
					<article-title>Analysis of Al2O3/Al FGM as Biomaterial of Artificial Human Femoral Bone and Compare with Ti6Al4V Alloy through Computational Study</article-title>
					<source>Global Journal of Researches in Engineering</source>
					<volume>13</volume>
					<issue>3</issue>
					<fpage>1</fpage>
					<lpage>8</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://engineeringresearch.org/index.php/GJRE/article/view/811">https://engineeringresearch.org/index.php/GJRE/article/view/811</ext-link>
				</element-citation>
			</ref>
			<ref id="B2">
				<mixed-citation>Amalraju, D. and Dawood, A. K. (2012). Mechanical Strength Evaluation Analysis of Stainless Steel and Titanium Locking Plate for Femur Bone Fracture. <italic>Engineering Science and Technology: An International Journal</italic>, 2 (3), 381-388.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Amalraju</surname>
							<given-names>D.</given-names>
						</name>
						<name>
							<surname>Dawood</surname>
							<given-names>A. K</given-names>
						</name>
					</person-group>
					<year>2012</year>
					<article-title>Mechanical Strength Evaluation Analysis of Stainless Steel and Titanium Locking Plate for Femur Bone Fracture</article-title>
					<source>Engineering Science and Technology: An International Journal</source>
					<volume>2</volume>
					<issue>3</issue>
					<fpage>381</fpage>
					<lpage>388</lpage>
				</element-citation>
			</ref>
			<ref id="B3">
				<mixed-citation>Bernhardt, A., Lode, A., Peters, F. and Gelinsky, M. (2011). Novel ceramic bone replacement material Osbones in a comparative in vitro study with osteoblasts. <italic>Clinical Oral Implants Research</italic>, 22(6), 651-657. DOI: 10.1111/j.1600-0501.2010.02015.x</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Bernhardt</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Lode</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Peters</surname>
							<given-names>F.</given-names>
						</name>
						<name>
							<surname>Gelinsky</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<year>2011</year>
					<article-title>Novel ceramic bone replacement material Osbones in a comparative in vitro study with osteoblasts</article-title>
					<source>Clinical Oral Implants Research</source>
					<volume>22</volume>
					<issue>6</issue>
					<fpage>651</fpage>
					<lpage>657</lpage>
					<pub-id pub-id-type="doi">10.1111/j.1600-0501.2010.02015.x</pub-id>
				</element-citation>
			</ref>
			<ref id="B4">
				<mixed-citation>Bougherara, H., Klika, V., Marsik, F., Marik, I. A. and Yahia, L. (2010). New Predictive Model for Monitoring Bone Remodeling. <italic>Journal of Biomedical Materials Research</italic>, 95(1). 9-24. DOI: 10.1002/jbm.a.32679</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Bougherara</surname>
							<given-names>H.</given-names>
						</name>
						<name>
							<surname>Klika</surname>
							<given-names>V.</given-names>
						</name>
						<name>
							<surname>Marsik</surname>
							<given-names>F.</given-names>
						</name>
						<name>
							<surname>Marik</surname>
							<given-names>I. A.</given-names>
						</name>
						<name>
							<surname>Yahia</surname>
							<given-names>L</given-names>
						</name>
					</person-group>
					<year>2010</year>
					<article-title>New Predictive Model for Monitoring Bone Remodeling</article-title>
					<source>Journal of Biomedical Materials Research</source>
					<volume>95</volume>
					<issue>1</issue>
					<fpage>9</fpage>
					<lpage>24</lpage>
					<pub-id pub-id-type="doi">10.1002/jbm.a.32679</pub-id>
				</element-citation>
			</ref>
			<ref id="B5">
				<mixed-citation>Budynas, R. G. and Nisbett, J. K. (2006). <italic>Shigley's Mechanical Engineering Design</italic> (8<sup>th</sup> ed.). New York: McGraw-Hill.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Budynas</surname>
							<given-names>R. G.</given-names>
						</name>
						<name>
							<surname>Nisbett</surname>
							<given-names>J. K</given-names>
						</name>
					</person-group>
					<year>2006</year>
					<source>Shigley's Mechanical Engineering Design</source>
					<edition>8</edition>
					<publisher-loc>New York</publisher-loc>
					<publisher-name>McGraw-Hill</publisher-name>
				</element-citation>
			</ref>
			<ref id="B6">
				<mixed-citation>Burgal, J. S., Peeva, L., Marchetti, P. and Livingston, A. (2015). Controlling molecular weight cut-off of PEEK nanofiltration membranes using a drying method. <italic>Journal of Membrane Science</italic>. <italic>493</italic>(1<italic>),</italic> 524-538. DOI: 10.1016/j.memsci.2015.07.012</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Burgal</surname>
							<given-names>J. S.</given-names>
						</name>
						<name>
							<surname>Peeva</surname>
							<given-names>L.</given-names>
						</name>
						<name>
							<surname>Marchetti</surname>
							<given-names>P.</given-names>
						</name>
						<name>
							<surname>Livingston</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<year>2015</year>
					<article-title>Controlling molecular weight cut-off of PEEK nanofiltration membranes using a drying method</article-title>
					<source>Journal of Membrane Science</source>
					<volume>493</volume>
					<issue>1</issue>
					<fpage>524</fpage>
					<lpage>538</lpage>
					<pub-id pub-id-type="doi">10.1016/j.memsci.2015.07.012</pub-id>
				</element-citation>
			</ref>
			<ref id="B7">
				<mixed-citation>Carter, D. R., Caler, W., Spencler, D. M. and Frankel, V. H. (2009). Fatigue Behavior of Adult Cortical Bone: The Influence of Mean Strain and Strain Range. <italic>Acta orthop Scand</italic> 
 <italic>52</italic>, 481-490. DOI: 10.3109/17453678108992136</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Carter</surname>
							<given-names>D. R.</given-names>
						</name>
						<name>
							<surname>Caler</surname>
							<given-names>W.</given-names>
						</name>
						<name>
							<surname>Spencler</surname>
							<given-names>D. M.</given-names>
						</name>
						<name>
							<surname>Frankel</surname>
							<given-names>V. H</given-names>
						</name>
					</person-group>
					<year>2009</year>
					<article-title>Fatigue Behavior of Adult Cortical Bone: The Influence of Mean Strain and Strain Range</article-title>
					<source>Acta orthop Scand</source>
					<volume>52</volume>
					<fpage>481</fpage>
					<lpage>490</lpage>
					<pub-id pub-id-type="doi">10.3109/17453678108992136</pub-id>
				</element-citation>
			</ref>
			<ref id="B8">
				<mixed-citation>Dash, P. P., Kishor, K. and Panda, S. K. (2013). <italic>Biomechanical Stress Analysis of Human Femur Bone</italic>. Paper presented at the International Conference on Computer Aided Engineering, Madras, Indian Institute of Technology.</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>Dash</surname>
							<given-names>P. P.</given-names>
						</name>
						<name>
							<surname>Kishor</surname>
							<given-names>K.</given-names>
						</name>
						<name>
							<surname>Panda</surname>
							<given-names>S. K</given-names>
						</name>
					</person-group>
					<year>2013</year>
					<source>Biomechanical Stress Analysis of Human Femur Bone</source>
					<conf-name>Paper presented at the International Conference on Computer Aided Engineering</conf-name>
					<conf-loc>Madras</conf-loc>
					<conf-sponsor>Indian Institute of Technology</conf-sponsor>
				</element-citation>
			</ref>
			<ref id="B9">
				<mixed-citation>Das, S. and Sarangi, S. K. (2014). Finite Element Analysis of Femur Fracture Fixation Plates. <italic>International Journal of Basic and Applied Biology</italic> 1 (1), 1-5.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Das</surname>
							<given-names>S.</given-names>
						</name>
						<name>
							<surname>Sarangi</surname>
							<given-names>S. K</given-names>
						</name>
					</person-group>
					<year>2014</year>
					<article-title>Element Analysis of Femur Fracture Fixation Plates</article-title>
					<source>International Journal of Basic and Applied Biology</source>
					<volume>1</volume>
					<issue>1</issue>
					<fpage>1</fpage>
					<lpage>5</lpage>
				</element-citation>
			</ref>
			<ref id="B10">
				<mixed-citation>Dhanopia, A. and Bhargava, M. (2016). Three Dimensional Virtual Modeling of Human Femur Bone with Prosthetic Plate and Screws. <italic>International Journal of Advanced Engineering, Management and Science</italic>, 2(9), 1489-1494. Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://ijaems.com/upload_images/issue_files/14%20IJAEMS-SEP-2016-11-3%20Dimensional%20Virtual%20Modelling%20of%20Human%20Femur%20Bone%20with%20Prosthetic%20Plate%20and%20Screws %20.pdf">https://ijaems.com/upload_images/issue_files/14%20IJAEMS-SEP-2016-11-3%20Dimensional%20Virtual%20Modelling%20of%20Human%20Femur%20Bone%20with%20Prosthetic%20Plate%20and%20Screws %20.pdf</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Dhanopia</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Bhargava</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<year>2016</year>
					<article-title>Three Dimensional Virtual Modeling of Human Femur Bone with Prosthetic Plate and Screws</article-title>
					<source>International Journal of Advanced Engineering, Management and Science</source>
					<volume>2</volume>
					<issue>9</issue>
					<fpage>1489</fpage>
					<lpage>1494</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://ijaems.com/upload_images/issue_files/14%20IJAEMS-SEP-2016-11-3%20Dimensional%20Virtual%20Modelling%20of%20Human%20Femur%20Bone%20with%20Prosthetic%20Plate%20and%20Screws %20.pdf">https://ijaems.com/upload_images/issue_files/14%20IJAEMS-SEP-2016-11-3%20Dimensional%20Virtual%20Modelling%20of%20Human%20Femur%20Bone%20with%20Prosthetic%20Plate%20and%20Screws %20.pdf</ext-link>
				</element-citation>
			</ref>
			<ref id="B11">
				<mixed-citation>Hambli, R. (2014). Connecting mechanics and bone cell activities in the bone remodeling process: an integrated finite element modeling. <italic>Frontiers Bioengineering and Biotechnology</italic>, 2(6), 1-12. DOI: 10.3389/fbioe.2014.00006</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Hambli</surname>
							<given-names>R</given-names>
						</name>
					</person-group>
					<year>2014</year>
					<article-title>Connecting mechanics and bone cell activities in the bone remodeling process: an integrated finite element modeling</article-title>
					<source>Frontiers Bioengineering and Biotechnology</source>
					<volume>2</volume>
					<issue>6</issue>
					<fpage>1</fpage>
					<lpage>12</lpage>
					<pub-id pub-id-type="doi">10.3389/fbioe.2014.00006</pub-id>
				</element-citation>
			</ref>
			<ref id="B12">
				<mixed-citation>Ibrahim, N. F., Daud, R., Zain, N. A., Izzawati, B. and Bajuri, Y. (2017). <italic>Stress Interaction Analysis of Uniaxial Fixator Pins-Diaphysis Femur Bone Interface Subjected to Four-Point Bending</italic>. Paper presented at the International Medical Device and Technology Conference, Kuala Lumpur, Universiti Teknologi Malaysia. Retrieved from: <ext-link ext-link-type="uri" xlink:href="http://www.utm.my/imeditec2017/files/2017/10/P14_Stress-Interaction-Analysis-of-Uniaxial-Fixator-Pins-Diaphysis-Femur-Bone-Interface-Subjected-to-Four-Point-Bending.pdf">http://www.utm.my/imeditec2017/files/2017/10/P14_Stress-Interaction-Analysis-of-Uniaxial-Fixator-Pins-Diaphysis-Femur-Bone-Interface-Subjected-to-Four-Point-Bending.pdf</ext-link>
				</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>Ibrahim</surname>
							<given-names>N. F.</given-names>
						</name>
						<name>
							<surname>Daud</surname>
							<given-names>R.</given-names>
						</name>
						<name>
							<surname>Zain</surname>
							<given-names>N. A.</given-names>
						</name>
						<name>
							<surname>Izzawati</surname>
							<given-names>B.</given-names>
						</name>
						<name>
							<surname>Bajuri</surname>
							<given-names>Y</given-names>
						</name>
					</person-group>
					<year>2017</year>
					<source>Stress Interaction Analysis of Uniaxial Fixator Pins-Diaphysis Femur Bone Interface Subjected to Four-Point Bending</source>
					<conf-name>Paper presented at the International Medical Device and Technology Conference</conf-name>
					<conf-loc>Kuala Lumpur</conf-loc>
					<conf-sponsor>Universiti Teknologi Malaysia</conf-sponsor>
					<ext-link ext-link-type="uri" xlink:href="http://www.utm.my/imeditec2017/files/2017/10/P14_Stress-Interaction-Analysis-of-Uniaxial-Fixator-Pins-Diaphysis-Femur-Bone-Interface-Subjected-to-Four-Point-Bending.pdf">http://www.utm.my/imeditec2017/files/2017/10/P14_Stress-Interaction-Analysis-of-Uniaxial-Fixator-Pins-Diaphysis-Femur-Bone-Interface-Subjected-to-Four-Point-Bending.pdf</ext-link>
				</element-citation>
			</ref>
			<ref id="B13">
				<mixed-citation>Keaveny, T. M., Morgan, E. F. and Yeh, O. C. (2004). Bone Mechanics. In: Kutz, Myer. <italic>Standard Handbook of Biomedical Engineering and Design</italic>. Bone Mechanics. New York: McGraw-Hill . </mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Keaveny</surname>
							<given-names>T. M.</given-names>
						</name>
						<name>
							<surname>Morgan</surname>
							<given-names>E. F.</given-names>
						</name>
						<name>
							<surname>Yeh</surname>
							<given-names>O. C</given-names>
						</name>
					</person-group>
					<year>2004</year>
					<chapter-title>Bone Mechanics</chapter-title>
					<person-group person-group-type="author">
						<name>
							<surname>Kutz</surname>
							<given-names>Myer</given-names>
						</name>
					</person-group>
					<source>Standard Handbook of Biomedical Engineering and Design</source>
					<comment>Bone Mechanics</comment>
					<publisher-loc>New York</publisher-loc>
					<publisher-name>McGraw-Hill</publisher-name>
				</element-citation>
			</ref>
			<ref id="B14">
				<mixed-citation>Kumar, N., Tandon, T., Silori, P. and Shaikh, A. (2015). <italic>Biomechanical stress analysis of a Human Femur bone using ANSYS</italic>. Paper presented at the 4th International Conference on Materials, Hyderabad, Institute of Engineering and Technology. DOI: 10.1016/j.matpr.2015.07.211</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>Kumar</surname>
							<given-names>N.</given-names>
						</name>
						<name>
							<surname>Tandon</surname>
							<given-names>T.</given-names>
						</name>
						<name>
							<surname>Silori</surname>
							<given-names>P.</given-names>
						</name>
						<name>
							<surname>Shaikh</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<year>2015</year>
					<source>Biomechanical stress analysis of a Human Femur bone using ANSYS</source>
					<conf-name>Paper presented at the 4th International Conference on Materials</conf-name>
					<conf-loc>Hyderabad</conf-loc>
					<conf-sponsor>Institute of Engineering and Technology</conf-sponsor>
					<pub-id pub-id-type="doi">10.1016/j.matpr.2015.07.211</pub-id>
				</element-citation>
			</ref>
			<ref id="B15">
				<mixed-citation>Lee, S., Porter, M., Wasko, S., Lau, G., Chen, P., Novitskaya, E. E., Tomsia, A. P., Almutairi, A., Meyers, M. A. and McKittrick, J. (2012) . <italic>Potential Bone Replacement Materials Prepared by Two Methods</italic>. Paper presented at the Symposium LL/MM -Gels and Biomedical Materials, Warrendale, Pa, Materials Research Society. DOI: 10.1557/opl.2012.671</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>Lee</surname>
							<given-names>S.</given-names>
						</name>
						<name>
							<surname>Porter</surname>
							<given-names>M.</given-names>
						</name>
						<name>
							<surname>Wasko</surname>
							<given-names>S.</given-names>
						</name>
						<name>
							<surname>Lau</surname>
							<given-names>G.</given-names>
						</name>
						<name>
							<surname>Chen</surname>
							<given-names>P.</given-names>
						</name>
						<name>
							<surname>Novitskaya</surname>
							<given-names>E. E.</given-names>
						</name>
						<name>
							<surname>Tomsia</surname>
							<given-names>A. P.</given-names>
						</name>
						<name>
							<surname>Almutairi</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Meyers</surname>
							<given-names>M. A.</given-names>
						</name>
						<name>
							<surname>McKittrick</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<year>2012</year>
					<source>Potential Bone Replacement Materials Prepared by Two Methods</source>
					<conf-name>Paper presented at the Symposium LL/MM -Gels and Biomedical Materials</conf-name>
					<conf-loc>Warrendale, Pa</conf-loc>
					<conf-sponsor>Materials Research Society</conf-sponsor>
					<pub-id pub-id-type="doi">10.1557/opl.2012.671</pub-id>
				</element-citation>
			</ref>
			<ref id="B16">
				<mixed-citation>Massachusetts Institute of Technology- MIT (Producer) (2006). Topic 21: Biomaterials for Organ Replacement. In: 3.051J/20.340J - <italic>Materials for Biomedical Applications</italic> [Online course]. Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://ocw.mit.edu/courses/materials-science-and-engineering/3-051j-materials-for-biomedical-applications-spring-2006/index.htm">https://ocw.mit.edu/courses/materials-science-and-engineering/3-051j-materials-for-biomedical-applications-spring-2006/index.htm</ext-link>
				</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>Massachusetts Institute of Technology- MIT (Producer)</collab>
					</person-group>
					<year>2006</year>
					<chapter-title>Topic 21: Biomaterials for Organ Replacement</chapter-title>
					<comment>3.051J/20.340J</comment>
					<source>Materials for Biomedical Applications</source>
					<ext-link ext-link-type="uri" xlink:href="https://ocw.mit.edu/courses/materials-science-and-engineering/3-051j-materials-for-biomedical-applications-spring-2006/index.htm">https://ocw.mit.edu/courses/materials-science-and-engineering/3-051j-materials-for-biomedical-applications-spring-2006/index.htm</ext-link>
				</element-citation>
			</ref>
			<ref id="B17">
				<mixed-citation>Mohammed, H., Fazlur, R., Mohammed, Y., Syed, Z., Shanawaz, P. and Tajuddin, Y. (2013). Hybrid Polymer Matrix Composites for Biomedical Applications. <italic>International Journal of Modern Engineering Research</italic>, 3(2), 970-979.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Mohammed</surname>
							<given-names>H.</given-names>
						</name>
						<name>
							<surname>Fazlur</surname>
							<given-names>R.</given-names>
						</name>
						<name>
							<surname>Mohammed</surname>
							<given-names>Y.</given-names>
						</name>
						<name>
							<surname>Syed</surname>
							<given-names>Z.</given-names>
						</name>
						<name>
							<surname>Shanawaz</surname>
							<given-names>P.</given-names>
						</name>
						<name>
							<surname>Tajuddin</surname>
							<given-names>Y</given-names>
						</name>
					</person-group>
					<year>2013</year>
					<article-title>Hybrid Polymer Matrix Composites for Biomedical Applications</article-title>
					<source>International Journal of Modern Engineering Research</source>
					<volume>3</volume>
					<issue>2</issue>
					<fpage>970</fpage>
					<lpage>979</lpage>
				</element-citation>
			</ref>
			<ref id="B18">
				<mixed-citation>Mohd Sheikh, S. A., Ganorkar, A. P. and Dehankar, R. N. (2016). Finite Element Analysis of Femoral Intramedullary Nailing. <italic>Journal for Research</italic>, 02(10), 1-8. Retrieved from: <ext-link ext-link-type="uri" xlink:href="http://www.journal4research.org/Article.php?manuscript=J4RV2I10003">http://www.journal4research.org/Article.php?manuscript=J4RV2I10003</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Mohd Sheikh</surname>
							<given-names>S. A.</given-names>
						</name>
						<name>
							<surname>Ganorkar</surname>
							<given-names>A. P.</given-names>
						</name>
						<name>
							<surname>Dehankar</surname>
							<given-names>R. N</given-names>
						</name>
					</person-group>
					<year>2016</year>
					<article-title>Finite Element Analysis of Femoral Intramedullary Nailing</article-title>
					<source>Journal for Research</source>
					<volume>02</volume>
					<issue>10</issue>
					<fpage>1</fpage>
					<lpage>8</lpage>
					<ext-link ext-link-type="uri" xlink:href="http://www.journal4research.org/Article.php?manuscript=J4RV2I10003">http://www.journal4research.org/Article.php?manuscript=J4RV2I10003</ext-link>
				</element-citation>
			</ref>
			<ref id="B19">
				<mixed-citation>Mughal, U. N., Khawaja, H. A. and Moatamedi, M. (2015). Finite element analysis of human femur bone. <italic>International Journal of Multiphysics</italic>, 9(2), 101-108. DOI: 10.1260/1750-9548.9.2.101</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Mughal</surname>
							<given-names>U. N.</given-names>
						</name>
						<name>
							<surname>Khawaja</surname>
							<given-names>H. A.</given-names>
						</name>
						<name>
							<surname>Moatamedi</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<year>2015</year>
					<article-title>Finite element analysis of human femur bone</article-title>
					<source>International Journal of Multiphysics</source>
					<volume>9</volume>
					<issue>2</issue>
					<fpage>101</fpage>
					<lpage>108</lpage>
					<pub-id pub-id-type="doi">10.1260/1750-9548.9.2.101</pub-id>
				</element-citation>
			</ref>
			<ref id="B20">
				<mixed-citation>Nautiyal, A. N., Nain, P. K. S. and Kumar, P. (2014). Study of Knee-Joint Mechanism before Implanting a Knee Prosthesis by Modeling and Finite Element Analysis of Knee-Joint Bones. <italic>International Journal of Advanced Mechanical Engineering</italic>, 4(7), 721-727.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Nautiyal</surname>
							<given-names>A. N.</given-names>
						</name>
						<name>
							<surname>Nain</surname>
							<given-names>P. K. S.</given-names>
						</name>
						<name>
							<surname>Kumar</surname>
							<given-names>P</given-names>
						</name>
					</person-group>
					<year>2014</year>
					<article-title>Study of Knee-Joint Mechanism before Implanting a Knee Prosthesis by Modeling and Finite Element Analysis of Knee-Joint Bones</article-title>
					<source>International Journal of Advanced Mechanical Engineering</source>
					<volume>4</volume>
					<issue>7</issue>
					<fpage>721</fpage>
					<lpage>727</lpage>
				</element-citation>
			</ref>
			<ref id="B21">
				<mixed-citation>Popa, D., Gherghina, G., Tudor, M. and Tarnita, D. (2006). A 3D Graphical Modeling Method for Human Femur Bone. <italic>Journal of Industrial Design and Engineering Graphics</italic>, 1 (2), 37-40. Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://doaj.org/article/4545cc912b034022a5d6ff84e03880d5">https://doaj.org/article/4545cc912b034022a5d6ff84e03880d5</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Popa</surname>
							<given-names>D.</given-names>
						</name>
						<name>
							<surname>Gherghina</surname>
							<given-names>G.</given-names>
						</name>
						<name>
							<surname>Tudor</surname>
							<given-names>M.</given-names>
						</name>
						<name>
							<surname>Tarnita</surname>
							<given-names>D</given-names>
						</name>
					</person-group>
					<year>2006</year>
					<article-title>A 3D Graphical Modeling Method for Human Femur Bone</article-title>
					<source>Journal of Industrial Design and Engineering Graphics</source>
					<volume>1</volume>
					<issue>2</issue>
					<fpage>37</fpage>
					<lpage>40</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doaj.org/article/4545cc912b034022a5d6ff84e03880d5">https://doaj.org/article/4545cc912b034022a5d6ff84e03880d5</ext-link>
				</element-citation>
			</ref>
			<ref id="B22">
				<mixed-citation>Qasim, M., Farinella, G., Zhang, J., Li, X., Yang, L., Eastell, R. and Viceconti, M. (2016). Patient-specific finite element estimated femur strength as a predictor of the risk of hip fracture: the effect of methodological determinants. <italic>Osteoporosis International</italic> 27(9), 2815-2822. DOI: 10.1007/s00198-016-3597-4</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Qasim</surname>
							<given-names>M.</given-names>
						</name>
						<name>
							<surname>Farinella</surname>
							<given-names>G.</given-names>
						</name>
						<name>
							<surname>Zhang</surname>
							<given-names>J.</given-names>
						</name>
						<name>
							<surname>Li</surname>
							<given-names>X.</given-names>
						</name>
						<name>
							<surname>Yang</surname>
							<given-names>L.</given-names>
						</name>
						<name>
							<surname>Eastell</surname>
							<given-names>R.</given-names>
						</name>
						<name>
							<surname>Viceconti</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<year>2016</year>
					<article-title>Patient-specific finite element estimated femur strength as a predictor of the risk of hip fracture: the effect of methodological determinants</article-title>
					<source>Osteoporosis International</source>
					<volume>27</volume>
					<issue>9</issue>
					<fpage>2815</fpage>
					<lpage>2822</lpage>
					<pub-id pub-id-type="doi">10.1007/s00198-016-3597-4</pub-id>
				</element-citation>
			</ref>
			<ref id="B23">
				<mixed-citation>Reddy, V. K. Ganesh, B. K. Bharathi K. C. ChittiBabu, P. (2016). Use of Finite Element Analysis to Predict Type of Bone Fractures and Fracture Risks in Femur due to Osteoporosis. <italic>Journal of Osteoporosis and Physical Activity</italic>, 4(3), 1-8. DOI: 10.4172/2329-9509.1000180</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Reddy</surname>
							<given-names>V. K</given-names>
						</name>
						<name>
							<surname>Ganesh</surname>
							<given-names>B. K</given-names>
						</name>
						<name>
							<surname>Bharathi</surname>
							<given-names>K. C</given-names>
						</name>
						<name>
							<surname>ChittiBabu</surname>
							<given-names>P</given-names>
						</name>
					</person-group>
					<year>2016</year>
					<article-title>Use of Finite Element Analysis to Predict Type of Bone Fractures and Fracture Risks in Femur due to Osteoporosis</article-title>
					<source>Journal of Osteoporosis and Physical Activity</source>
					<volume>4</volume>
					<issue>3</issue>
					<fpage>1</fpage>
					<lpage>8</lpage>
					<pub-id pub-id-type="doi">10.4172/2329-9509.1000180</pub-id>
				</element-citation>
			</ref>
			<ref id="B24">
				<mixed-citation>Schileo, E., Taddei, F., Malandrino, A., Cristofolini, L. and Vicecont, M. (2007). Subject-specific finite element models can accurately predict strain levels in long bones. <italic>Journal of Biomechanics</italic>, 40(13), 2982-2989. DOI: 10.1016/j.jbiomech.2007.02.010</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Schileo</surname>
							<given-names>E.</given-names>
						</name>
						<name>
							<surname>Taddei</surname>
							<given-names>F.</given-names>
						</name>
						<name>
							<surname>Malandrino</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Cristofolini</surname>
							<given-names>L.</given-names>
						</name>
						<name>
							<surname>Vicecont</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<year>2007</year>
					<article-title>Subject-specific finite element models can accurately predict strain levels in long bones</article-title>
					<source>Journal of Biomechanics</source>
					<volume>40</volume>
					<issue>13</issue>
					<fpage>2982</fpage>
					<lpage>2989</lpage>
					<pub-id pub-id-type="doi">10.1016/j.jbiomech.2007.02.010</pub-id>
				</element-citation>
			</ref>
			<ref id="B25">
				<mixed-citation>Senthil Maharaj, P. S., Maheswaran, R. and Vasanthanathan, A. (2013). Numerical Analysis of Fractured Femur Bone with Prosthetic Bone Plates. <italic>Procedia Engineering</italic>, <italic>64</italic>, 1242-1251. DOI: 10.1016/j.proeng.2013.09.204</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Senthil Maharaj</surname>
							<given-names>P. S.</given-names>
						</name>
						<name>
							<surname>Maheswaran</surname>
							<given-names>R.</given-names>
						</name>
						<name>
							<surname>Vasanthanathan</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<year>2013</year>
					<article-title>Numerical Analysis of Fractured Femur Bone with Prosthetic Bone Plates</article-title>
					<source>Procedia Engineering</source>
					<volume>64</volume>
					<fpage>1242</fpage>
					<lpage>1251</lpage>
					<pub-id pub-id-type="doi">10.1016/j.proeng.2013.09.204</pub-id>
				</element-citation>
			</ref>
			<ref id="B26">
				<mixed-citation>Sherekar, R. M. and Pawar, A. N. (2013). Numerical Analysis of Human Femoral Bone in Different Phases. <italic>International Journal of Engineering and Innovative Technology</italic>, 2(12), 76-80.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Sherekar</surname>
							<given-names>R. M.</given-names>
						</name>
						<name>
							<surname>Pawar</surname>
							<given-names>A. N</given-names>
						</name>
					</person-group>
					<year>2013</year>
					<article-title>Numerical Analysis of Human Femoral Bone in Different Phases</article-title>
					<source>International Journal of Engineering and Innovative Technology</source>
					<volume>2</volume>
					<issue>12</issue>
					<fpage>76</fpage>
					<lpage>80</lpage>
				</element-citation>
			</ref>
			<ref id="B27">
				<mixed-citation>Shireesha, Y., Ramana, S. V. and Rao, P. G. (2013). Modelling and static analysis of femur bone by using different implant materials. <italic>Journal of Mechanical and Civil Engineering</italic>, 7(4), 82-91. DOI: 10.9790/1684-0748291</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Shireesha</surname>
							<given-names>Y.</given-names>
						</name>
						<name>
							<surname>Ramana</surname>
							<given-names>S. V.</given-names>
						</name>
						<name>
							<surname>Rao</surname>
							<given-names>P. G</given-names>
						</name>
					</person-group>
					<year>2013</year>
					<article-title>Modelling and static analysis of femur bone by using different implant materials</article-title>
					<source>Journal of Mechanical and Civil Engineering</source>
					<volume>7</volume>
					<issue>4</issue>
					<fpage>82</fpage>
					<lpage>91</lpage>
					<pub-id pub-id-type="doi">10.9790/1684-0748291</pub-id>
				</element-citation>
			</ref>
			<ref id="B28">
				<mixed-citation>Taheri, N. S., Blicblau, A. S. and Singh, M. (2012). Effect of different load conditions on a DHS Effect of different load conditions on a DHS Effect of different load conditions on a DHS implanted human femur. GSTF <italic>Journal of Engineering Technology</italic>, 1 (1), 141-146. Retrieved from: <ext-link ext-link-type="uri" xlink:href="http://dl6.globalstf.org/index.php/jet/article/view/37">http://dl6.globalstf.org/index.php/jet/article/view/37</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Taheri</surname>
							<given-names>N. S.</given-names>
						</name>
						<name>
							<surname>Blicblau</surname>
							<given-names>A. S.</given-names>
						</name>
						<name>
							<surname>Singh</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<year>2012</year>
					<article-title>Effect of different load conditions on a DHS Effect of different load conditions on a DHS Effect of different load conditions on a DHS implanted human femur</article-title>
					<source>GSTF Journal of Engineering Technology</source>
					<volume>1</volume>
					<issue>1</issue>
					<fpage>141</fpage>
					<lpage>146</lpage>
					<ext-link ext-link-type="uri" xlink:href="http://dl6.globalstf.org/index.php/jet/article/view/37">http://dl6.globalstf.org/index.php/jet/article/view/37</ext-link>
				</element-citation>
			</ref>
			<ref id="B29">
				<mixed-citation>Toth-Tascau, M., Rusu, L. and Toader, C. (2010). Biomechanical Behavior of Implanted Long Bones. <italic>Annals of the Oradea University. Fascicle of Management and Technological Engineering</italic>
 <italic>, [</italic>
 <italic>XIX (IX)</italic>] 2. 283-288. DOI: 10.15660/auofmte.2010-2.1891</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Toth-Tascau</surname>
							<given-names>M.</given-names>
						</name>
						<name>
							<surname>Rusu</surname>
							<given-names>L.</given-names>
						</name>
						<name>
							<surname>Toader</surname>
							<given-names>C</given-names>
						</name>
					</person-group>
					<year>2010</year>
					<article-title>Biomechanical Behavior of Implanted Long Bones</article-title>
					<source>Annals of the Oradea University. Fascicle of Management and Technological Engineering</source>
					<comment>XIX (IX)</comment>
					<fpage>283</fpage>
					<lpage>288</lpage>
					<pub-id pub-id-type="doi">10.15660/auofmte.2010-2.1891</pub-id>
				</element-citation>
			</ref>
			<ref id="B30">
				<mixed-citation>Turner, C. H., Wang, T. and Burr, D. B. (2001). Shear Strength and Fatigue Properties of Human Cortical Bone Determined from Pure Shear Tests. <italic>Calcified Tissue International</italic>, 69(6), 373-378. DOI: 10.1007/s00223-001-1006-1</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Turner</surname>
							<given-names>C. H.</given-names>
						</name>
						<name>
							<surname>Wang</surname>
							<given-names>T.</given-names>
						</name>
						<name>
							<surname>Burr</surname>
							<given-names>D. B</given-names>
						</name>
					</person-group>
					<year>2001</year>
					<article-title>Shear Strength and Fatigue Properties of Human Cortical Bone Determined from Pure Shear Tests</article-title>
					<source>Calcified Tissue International</source>
					<volume>69</volume>
					<issue>6</issue>
					<fpage>373</fpage>
					<lpage>378</lpage>
					<pub-id pub-id-type="doi">10.1007/s00223-001-1006-1</pub-id>
				</element-citation>
			</ref>
			<ref id="B31">
				<mixed-citation>Yousif, A. E. and Aziz, M. Y. (2012). Biomechanical Analysis of the human femur bone during normal walking and standing up. <italic>IOSR Journal of Engineering</italic>, 2(8), 13-19.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Yousif</surname>
							<given-names>A. E.</given-names>
						</name>
						<name>
							<surname>Aziz</surname>
							<given-names>M. Y</given-names>
						</name>
					</person-group>
					<year>2012</year>
					<article-title>Biomechanical Analysis of the human femur bone during normal walking and standing up</article-title>
					<source>IOSR Journal of Engineering</source>
					<volume>2</volume>
					<issue>8</issue>
					<fpage>13</fpage>
					<lpage>19</lpage>
				</element-citation>
			</ref>
			<ref id="B32">
				<mixed-citation>Zakiuddin, K., Khan, I. A., Roshni, A. and Hinge, A. (2016). A review Paper on Biomechanical Analysis of Human Femur. <italic>International Journal of innovative research in Science and Engineering</italic>, 2(3), 356-363.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Zakiuddin</surname>
							<given-names>K.</given-names>
						</name>
						<name>
							<surname>Khan</surname>
							<given-names>I. A.</given-names>
						</name>
						<name>
							<surname>Roshni</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Hinge</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<year>2016</year>
					<article-title>A review Paper on Biomechanical Analysis of Human Femur</article-title>
					<source>International Journal of innovative research in Science and Engineering</source>
					<volume>2</volume>
					<issue>3</issue>
					<fpage>356</fpage>
					<lpage>363</lpage>
				</element-citation>
			</ref>
			<ref id="B33">
				<mixed-citation>Zhang, B., Wang, X., Yu, Y. and Zheng, J. (2017). Heterogeneous modelling and finite element analysis of the femur. <italic>MATEC Web of Conferences</italic>, 139(55), 1-4. DOI: 10.1051/matecconf/201713900055</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Zhang</surname>
							<given-names>B.</given-names>
						</name>
						<name>
							<surname>Wang</surname>
							<given-names>X.</given-names>
						</name>
						<name>
							<surname>Yu</surname>
							<given-names>Y.</given-names>
						</name>
						<name>
							<surname>Zheng</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<year>2017</year>
					<article-title>Heterogeneous modelling and finite element analysis of the femur</article-title>
					<source>MATEC Web of Conferences</source>
					<volume>139</volume>
					<issue>55</issue>
					<fpage>1</fpage>
					<lpage>4</lpage>
					<pub-id pub-id-type="doi">10.1051/matecconf/201713900055</pub-id>
				</element-citation>
			</ref>
		</ref-list>
		<fn-group>
			<fn fn-type="other" id="fn1">
				<label>How to cite:</label>
				<p> Kashan, J. S., and Ali, S. M. (2019). Modeling and simulation for mechanical behavior of modified biocomposite for scaffold application. <italic>Ingeniería e Investigación,</italic> 39(1), 63-75. DOI: 10.15446/ing.investig.v39n1.73638</p>
			</fn>
			<fn fn-type="other" id="fn2">
				<label>Attribution 4.0 International</label>
				<p> (CC BY 4.0) Share - Adapt <graphic xlink:href="0120-5609-iei-39-01-63-g001.png"/>
				</p>
			</fn>
		</fn-group>
	</back>
</article>