<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article
  PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article article-type="research-article" dtd-version="1.1" specific-use="sps-1.9" xml:lang="es" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
	<front>
		<journal-meta>
			<journal-id journal-id-type="publisher-id">rcq</journal-id>
			<journal-title-group>
				<journal-title>Revista Colombiana de Química</journal-title>
				<abbrev-journal-title abbrev-type="publisher">Rev.Colomb.Quim.</abbrev-journal-title>
			</journal-title-group>
			<issn pub-type="ppub">0120-2804</issn>
			<issn pub-type="epub">2357-3791</issn>
			<publisher>
				<publisher-name>Departamento de Química, Universidad Nacional de Colombia.</publisher-name>
			</publisher>
		</journal-meta>
		<article-meta>
			<article-id pub-id-type="doi">10.15446/rev.colomb.quim.v52n3.111499</article-id>
			<article-id pub-id-type="other">3</article-id>


			<article-categories>
				<subj-group subj-group-type="heading">
					<subject>Artículos originales de investigación</subject>
				</subj-group>
			</article-categories>
			<title-group>
				<article-title>Preparación de muestras sólidas para el análisis por fluorescencia de rayos X: una revisión</article-title>
				<trans-title-group xml:lang="en">
					<trans-title>Solid sample preparation for X-ray fluorescence analysis: a review</trans-title>
				</trans-title-group>
				<trans-title-group xml:lang="pt">
					<trans-title>Preparação de amostras sólidas para análise de fluorescência de raios X: uma revisão</trans-title>
				</trans-title-group>
			</title-group>
			<contrib-group>
				<contrib contrib-type="author">
					<name>
						<surname>Pérez Díaz</surname>
						<given-names>Linda Alejandra</given-names>
					</name>
					<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
					<xref ref-type="corresp" rid="c1"><sup>*</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<name>
						<surname>Serna Saiz</surname>
						<given-names>Juliana</given-names>
					</name>
					<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<name>
						<surname>Torres Quezada</surname>
						<given-names>Henry</given-names>
					</name>
					<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
				</contrib>
			</contrib-group>
			<aff id="aff1">
				<label>1</label>
				<institution content-type="original">Instituto Nacional de Metrología de Colombia. Bogotá, Colombia. liperezd@unal.edu.co</institution>
				<institution content-type="normalized">Universidad Nacional de Colombia</institution>
				<institution content-type="orgname">Instituto Nacional de Metrología de Colombia</institution>
				<addr-line>
					<city>Bogotá</city>
				</addr-line>
				<country country="CO">Colombia</country>
				<email>liperezd@unal.edu.co</email>
			</aff>
			<aff id="aff2">
				<label>2</label>
				<institution content-type="original">Instituto Nacional de Metrología de Colombia. Bogotá, Colombia. jserna@inm.gov.co</institution>
				<institution content-type="normalized">Universidad Nacional de Colombia</institution>
				<institution content-type="orgname">Instituto Nacional de Metrología de Colombia</institution>
				<addr-line>
					<city>Bogotá</city>
				</addr-line>
				<country country="CO">Colombia</country>
				<email>jserna@inm.gov.co</email>
			</aff>
			<aff id="aff3">
				<label>3</label>
				<institution content-type="original">Instituto Nacional de Metrología de Colombia. Bogotá, Colombia. htquezada@inm.gov.co</institution>
				<institution content-type="normalized">Universidad Nacional de Colombia</institution>
				<institution content-type="orgname">Instituto Nacional de Metrología de Colombia</institution>
				<addr-line>
					<city>Bogotá</city>
				</addr-line>
				<country country="CO">Colombia</country>
				<email>htquezada@inm.gov.co</email>
			</aff>
			<author-notes>
				<corresp id="c1">
					<label><sup>*</sup></label>
					<email>liperezd@unal.edu.co</email>
				</corresp>
			</author-notes>
			<pub-date date-type="pub" publication-format="electronic">
				<day>28</day>
				<month>12</month>
				<year>2025</year>
			</pub-date>
			<pub-date date-type="collection" publication-format="electronic">
				<season>Sep-Dec</season>
				<year>2023</year>
			</pub-date>
			<volume>52</volume>
			<issue>3</issue>
			<elocation-id>e111499</elocation-id>
			<history>
				<date date-type="received">
					<day>31</day>
					<month>10</month>
					<year>2023</year>
				</date><bold>.</bold><date date-type="rev-recd">
					<day>22</day>
					<month>03</month>
					<year>2024</year>
				</date>
				<date date-type="accepted">
					<day>15</day>
					<month>05</month>
					<year>2024</year>
				</date>
			</history>
			<permissions>
				<license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/" xml:lang="es">
					<license-p>Este es un artículo publicado en acceso abierto bajo una licencia Creative Commons</license-p>
				</license>
			</permissions>
			<abstract>
				<title>Resumen</title>
				<p>La fluorescencia de rayos X (XRF, por sus siglas en inglés) permite realizar análisis multielementales en diversas matrices sólidas, incluidos polvos y granos. Para obtener resultados confiables, la muestra preparada debe cumplir con ciertos criterios relacionados con su espesor, la plani-tud de su superficie, su homogeneidad y el tamaño de sus partículas. Las muestras sólidas heterogéneas que se deseen medir deben pulverizarse, homogeneizarse y prepararse como polvo suelto, polvos prensados (pellets) o perlas fundidas, si se buscan mediciones precisas y reproducibles. Las condiciones de medición están definidas por la profundidad analítica de los rayos X fluorescentes de los analitos, y se pueden estimar a partir de la relación que existe entre la absorción de cada rayo y su respectiva energía, y la composición y densidad de la muestra. Así mismo, con el propósito de asegurar la validez de los resultados, se debe validar el método de medición, para confirmar que cumple con el propósito para el cual fue desarrollado. Esta revisión está enfocada en la preparación de muestras sólidas, en el análisis cuantitativo, el cual incluye la validación de los métodos involucrados en las mediciones por espectrometría de XRF, y en las principales aplicaciones de la técnica.</p>
			</abstract>
			<trans-abstract xml:lang="en">
				<title>Abstract</title>
				<p>X-ray fluorescence (XRF) allows multielement analysis to be performed on a variety of solid matrices, including powders and grains. To obtain reliable results, the sample must meet certain criteria related to its thickness, surface flatness, homogeneity and particle size. Heterogeneous solid samples to be measured must be pulverized, homogenized, and prepared as loose powder, pressed powders (pellets) or fused beads, if accurate and reproducible measurements are sought. The measurement conditions are defined by the analytical depth of the fluorescent X-rays of the analytes, and can be estimated from the relationship between the absorption of each beam and its respective energy, and the composition and density of the sample. Furthermore, in purpose of assuring the validity of the results, the measurement method must be validated to confirm that it fulfills the purpose for which it was developed. This review is focused on the preparation of solid samples, the quantitative analysis, which includes the validation of the methods involved in XRF spectrometry measurements, and on the main applications of the technique.</p>
			</trans-abstract>
			<trans-abstract xml:lang="pt">
				<title>Resumo</title>
				<p>A fluorescência de raios X (XRF) permite que a análise multielementar seja realizada em uma variedade de matrizes sólidas, incluindo pós e grãos. Para obter resultados confiáveis, a amostra preparada deve atender a determinados critérios relacionados à sua espessura, planicidade da superfície, homogeneidade e tamanho da partícula. As amostras sólidas heterogêneas a serem medidas devem ser pulverizadas, homogeneizadas e preparadas como pós soltos, pós prensados <italic>(pellets)</italic> ou esferas fundidas, caso se deseje obter medidas precisas e reprodutíveis. As condições de medidas são definidas pela profundidade analítica dos raios X fluorescentes dos analitos, e podem ser estimadas a partir da relação entre a absorção de cada raio e sua respectiva energia, além da composição e da densidade da amostra. Também, para garantir a validade dos resultados, o método de medição deve ser validado para confirmar que ele cumpre a finalidade para a qual foi desenvolvido. Esta revisão enfoca na preparação de amostras sólidas, na análise quantitativa, incluindo a validação dos métodos envolvidos nas medidas por XRF, e nas principais aplicações da técnica.</p>
			</trans-abstract>
			<kwd-group xml:lang="es">
				<title>Palabras clave:</title>
				<kwd>XRF</kwd>
				<kwd>efecto matriz</kwd>
				<kwd>muestras sólidas heterogéneas</kwd>
				<kwd>análisis multielemental</kwd>
				<kwd>parámetros de validación</kwd>
			</kwd-group>
			<kwd-group xml:lang="en">
				<title>Keywords:</title>
				<kwd>XRF</kwd>
				<kwd>heterogeneous solid samples</kwd>
				<kwd>matrix effect</kwd>
				<kwd>multielemental analysis</kwd>
				<kwd>validation parameters</kwd>
			</kwd-group>
			<kwd-group xml:lang="pt">
				<title>Palavras-chave:</title>
				<kwd>XRF</kwd>
				<kwd>efeito de matriz</kwd>
				<kwd>amostras sólidas heterogéneas</kwd>
				<kwd>análise multielementar</kwd>
				<kwd>parâmetros de validação</kwd>
			</kwd-group>
			<counts>
				<fig-count count="28"/>
				<table-count count="10"/>
				<equation-count count="5"/>
				<ref-count count="117"/>
				<page-count count="20"/>
			</counts>
		</article-meta>
	</front>
	<body>
		<sec sec-type="intro">
			<title>Introducción</title>
			<p>A medida que las técnicas analíticas instrumentales se vuelven cada vez más sofisticadas, empiezan a ser adoptadas en diversos campos. Actualmente, para realizar análisis multielemental a diversos tipos de matrices, se tiene disponibilidad de un gran número de técnicas instrumentales tales como la espectroscopía de absorción atómica (AA) [<xref ref-type="bibr" rid="B1">1</xref>], la espectrometría de masas con plasma acoplado inductivamente (ICP-MS, por sus siglas en inglés) [<xref ref-type="bibr" rid="B2">2</xref>], la espectrometría de emisión óptica con plasma acoplado inductivamente (ICP-OES, por sus siglas en inglés) [<xref ref-type="bibr" rid="B3">3</xref>], la cromatografía iónica (IC) [<xref ref-type="bibr" rid="B4">4</xref>] y la fluorescencia de rayos X (XRF, por sus siglas en inglés), entre otras. Esta última se destaca porque cuenta con un amplio campo de acción que permite llevar a cabo el análisis multielemental en diversos tipos de muestras y para diferentes propósitos, como en el estudio del medio ambiente, para el análisis de suelos, plantas y agua, en la industria de productos alimenticios y de bebidas, en la medicina, la biología, la mineralogía, la geología, la arqueología, el arte y el campo forense, entre otros [<xref ref-type="bibr" rid="B5">5</xref>, <xref ref-type="bibr" rid="B6">6</xref>].</p>
			<p>Existen algunas técnicas que permiten analizar sólidos directamente: la XRF, que requiere de una fuente de radiación que puede ser un tubo de rayos X, radioisótopos o radiación sincrotrón [<xref ref-type="bibr" rid="B7">7</xref>] (dependiendo del espectrómetro de XRF); el análisis de emisión de rayos X inducido por partículas (PIXE, por sus siglas en inglés), que requiere de un acelerador de iones [<xref ref-type="bibr" rid="B8">8</xref>] y el análisis instrumental de activación de neutrones (INAA, por sus siglas en inglés), que hace uso de un reactor nuclear [<xref ref-type="bibr" rid="B9">9</xref>]. Sin embargo, las dos últimas técnicas son de alto costo de operación, lo que hace que la XRF sea la más versátil y atractiva, ya que permite realizar análisis cualitativos y cuantitativos a muestras sólidas y liquidas en una amplia gama de concentraciones, desde mg/kg hasta niveles de componentes principales expresados en porcentajes. Así mismo, la XRF es una técnica no destructiva que permite el análisis directo de muestras a las cuales no es posible hacer pretratamiento o preparación (objetos preciosos, joyería, artefactos arqueológicos y piezas de arte), ya que permite mantener la integridad de la pieza o muestra analizada.</p>
			<p>En la actualidad, existen diferentes tipos de técnicas de XRF, dentro de las que se destaca la fluorescencia de rayos X por dispersión de longitud de onda (WDXRF), la fluorescencia de rayos X por energía dispersiva (EDXRF) y la fluorescencia de rayos X por reflexión total (TXRF). Se han realizado diversos estudios donde se comparan los espectrómetros de los dos primeros tipos de XRF con el fin de determinar el método de dispersión, la resolución, el límite de detección, el tiempo de análisis, la precisión y exactitud, el método de análisis (cualitativo y cuantitativo) de las muestras [<xref ref-type="bibr" rid="B10">10</xref>], los elementos que se pueden analizar y sus respectivos límites de detección, los cuales van a depender principalmente del sistema que se utilice. Así, el intervalo de medición elemental para EDXRF va desde sodio (Na) hasta uranio (U), para WDXRF es aún más amplio, desde berilio (Be) hasta uranio (U), y para el caso de la TXRF, que se puede considerar una variedad mejorada de la EDXRF, el intervalo de análisis va desde aluminio (Al) hasta uranio (U).</p>
			<p>La naturaleza de las muestras que se pueden medir por WDXRF y EDXRF son muestras liquidas y sólidas, la preparación de muestras sólidas se explica a mayor profundidad en la sección &quot;Análisis por XRF&quot;. Para el caso de la naturaleza de las muestras que se miden por TRXF, es importante destacar que se analizan líquidos, polvos y suspensiones, pero que su preparación es diferente a la preparación convencional para muestras que se miden por WDXRF y EDXRF. En TXRF, las muestras se preparan sobre un portamuestras, como una película delgada para el análisis cuantitativo o como un microfragmento para el análisis cualitativo. Para los líquidos, se requiere de unos pocos microlitros de muestra homogénea con un estándar interno que se deposita sobre el portamuestras, posteriormente se secan por calor o al vacío y se llevan a medición en el espectrómetro [<xref ref-type="bibr" rid="B11">11</xref>]. Las muestras sólidas, como el tejido vegetal y las muestras de suelo, primero se secan y se muelen, luego se suspenden en solución detergente, se diluyen y homogeneizan y, por último, se colocan en el portamuestras. Los polvos, sedimentos u otros sólidos pueden digerirse en una solución ácida suave o convertirse en una suspensión antes de colocarse en el portamuestras [<xref ref-type="bibr" rid="B12">12</xref>].</p>
			<p>Los análisis instrumentales, en términos generales, pueden proporcionar fácilmente un resultado en cualquier condición de la muestra. Sin embargo, un método analítico inadecuado producirá un resultado significativamente erróneo, llevando a los investigadores a una conclusión equivocada. En la XRF, para obtener un resultado confiable, el analista debe optimizar la preparación de la muestra en función de los parámetros de homogeneidad, planitud de la superficie, tamaño de las partículas, espesor y densidad; además, debe establecer correctamente las condiciones de la medición (optimización y validación del método) y realizar el aseguramiento de la validez de los resultados haciendo uso de materiales de referencia certificados (MRC).</p>
			<p>En este sentido, esta revisión presenta la preparación de la muestra (homogeneización, tamaño de las partículas, secado, tipo de muestra y espesor) que suele realizarse a diversas matrices (alimentos, alimentos para animales, cementos, suelos, productos farmacéuticos, polímeros, etc.) para la medición por XRF; además, presenta el proceso de medición de muestras típicas como polvos sueltos, polvos prensados y perlas fundidas, así como sus aplicaciones. Por último, se hace un repaso tanto de la determinación por XRF, como de la calibración y la validación para garantizar la fiabilidad del análisis.</p>
			<sec>
				<title>Principio de medición</title>
				<p>En la XRF la radiación es de tipo ionizante y es originada por la incidencia de los rayos X que emite una fuente artificial (tubo de rayos X) sobre la superficie de la muestra de análisis, afectando a los electrones de energía más baja, que son los que se encuentran cerca al núcleo, obligándolos a cambiar de orbital, o incluso a abandonar el átomo, debido al aumento súbito de la energía [<xref ref-type="bibr" rid="B13">13</xref>]. En seguida, un electrón que está en un nivel externo (más energético) salta hacia un nivel interior o más cercano al núcleo (menos energético), ocupando la vacante que ha sido dejada. Dicho electrón debe perder energía, debido a la modificación de su estado de movimiento y lo hace mediante la emisión de un rayo X característico de elementos químicos irradiados desde la profundidad analítica (profundidad de escape) <bold>(</bold><xref ref-type="fig" rid="f1">figura 1</xref><bold>)</bold> [<xref ref-type="bibr" rid="B14">14</xref>].</p>
				<p>
					<fig id="f1">
						<label>Figura 1</label>
						<caption>
							<title>Mecanismo de generación de rayos X característicos. Tomado de [<xref ref-type="bibr" rid="B17">17</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf1.png"/>
					</fig>
				</p>
				<p>En la muestra se generan impulsos por efecto de los rayos X y estos son proporcionales a la energía de los rayos X. El registro de la amplitud del impulso permite crear un espectro de energía en el que se identifica la composición de la muestra, es decir, los elementos que la conforman y la concentración en la que se encuentran, esto se debe a que cada elemento de la tabla periódica genera una radiación característica correspondiente a cada posible salto de nivel de energía [<xref ref-type="bibr" rid="B14">14</xref>, <xref ref-type="bibr" rid="B15">15</xref>]. El análisis de esta información también permite determinar la concentración de cada elemento que está presente en la muestra, en función de sus espectros de XRF únicos [<xref ref-type="bibr" rid="B16">16</xref>].</p>
				<p>Durante la interacción de los rayos X con la muestra, se pueden presentar, además de la fluorescencia, dos interacciones importantes conocidas como radiaciones dispersivas: el efecto de dispersión de Compton y el efecto de dispersión de Rayleigh.</p>
			</sec>
			<sec>
				<title><italic>Dispersión Compton y Rayleigh</italic></title>
				<p>En la dispersión de los rayos X pueden ocurrir dos fenómenos, uno con pérdida de energía (dispersión Compton) y otro sin pérdida de energía (dispersión Rayleigh). En la dispersión Compton, los electrones poco ligados (los de las capas más externas) [<xref ref-type="bibr" rid="B18">18</xref>] interactúan con los fotones que, al momento de ser dispersados, tienen menos energía y, por lo tanto, una longitud de onda más larga que el fotón incidente. Debido a la interacción, el electrón recibe algo de energía del fotón y es emitido, mientras que el fotón reduce su energía y se dispersa en un ángulo 6 (ángulo que se forma entre la trayectoria original del fotón X y la trayectoria del fotón dispersado después de interactuar con un electrón) [<xref ref-type="bibr" rid="B19">19</xref>] <bold>(</bold><xref ref-type="fig" rid="f2">figura 2</xref><bold>).</bold> El fotón dispersado puede provocar más interacciones con otros electrones del átomo y generar fotoelectrones no deseados de menor energía. La dispersión de Compton suele ocurrir cuando las muestras irradiadas tienen composición elemental de bajo número atómico.</p>
				<p>
					<fig id="f2">
						<label>Figura 2</label>
						<caption>
							<title>Dispersión Compton. Tomado de [<xref ref-type="bibr" rid="B20">20</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf2.png"/>
					</fig>
				</p>
				<p>En la dispersión Rayleigh, el fotón incidente interacciona y excita el átomo, pero no se produce ionización ni pérdida de energía. Tiene lugar a bajas energías (&lt; 30 keV) y, por lo tanto, ninguna energía es convertida en movimiento electrónico ni absorbida en el medio [<xref ref-type="bibr" rid="B21">21</xref>]. El único efecto que ocurre es la dispersión del fotón en pequeños ángulos respecto a la trayectoria inicial del fotón <bold>(</bold><xref ref-type="fig" rid="f3">figura 3</xref><bold>),</bold> los rayos X dispersos tienen la misma longitud de onda que el haz incidente. La dispersión Rayleigh es muy probable cuando las muestras irradiadas tienen una composición elemental de alto número atómico.</p>
				<p>
					<fig id="f3">
						<label>Figura 3</label>
						<caption>
							<title>Dispersión de Rayleigh. Tomado de [<xref ref-type="bibr" rid="B19">19</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf3.png"/>
					</fig>
				</p>
				<sec>
					<title><italic>Notación de la radiación emitida</italic></title>
					<p>Dado que cada átomo posee una estructura de niveles de energía de electrones característica, los fotones emitidos en el llenado de los huecos permiten su identificación, por lo que, dependiendo de la transición que tenga lugar, se denomina la radiación con las letras K, L o M. Existen formas de nombrar a las líneas de radiación característica, tales como las notaciones Siegbahn y IUPAC (Unión Internacional de Química Pura y Aplicada), que son las que más se usan según lo reportado por varias investigaciones. En la notación Siegbahn se identifica cada línea de transición con el símbolo del elemento, el nombre de la capa donde está la vacancia inicial y una letra griega (α, β, Y) que indica la intensidad relativa de la línea [<xref ref-type="bibr" rid="B22">22</xref>]. En la notación Siegbahn no se nombra el nivel del que proviene el electrón que llena la vacancia, en cambio, en la notación IUPAC, la línea es nombrada por el elemento y el nivel donde la vacancia inicial se encuentra, seguido por el nivel del que viene el electrón a llenar esa vacancia. En la <xref ref-type="table" rid="t1">tabla 1</xref> se muestran las equivalencias entre las notaciones Siegbahn y IUPAC.</p>
					<p>
						<table-wrap id="t1">
							<label>Tabla 1</label>
							<caption>
								<title>Equivalencia entre la notación Siegbahn y IUPAC. Tomado de [<xref ref-type="bibr" rid="B23">23</xref>].</title>
							</caption>
							<graphic xlink:href="2357-3791-rcq-52-03-e111499-gt1.png"/>
						</table-wrap>
					</p>
					<p>La <xref ref-type="fig" rid="f4">figura 4</xref> muestra las transiciones típicas de los electrones para las distintas capas (siendo las más fáciles de detectar en un análisis por XRF las líneas K y L). La línea inferior representa la capa de un átomo y las flechas simbolizan una transición de electrones, acompañada de la formación de una línea de XRF. Por su parte, en la <xref ref-type="fig" rid="f5">figura 5</xref> se muestra un espectro de unas muestras de lápices de colores irradiadas por rayos X, en la cual se observan múltiples picos de diferentes intensidades, con las respectivas líneas medidas.</p>
					<p>
						<fig id="f4">
							<label>Figura 4</label>
							<caption>
								<title>Niveles de energía que indican las transiciones más comunes que se producen en XRF. Tomado de [<xref ref-type="bibr" rid="B24">24</xref>].</title>
							</caption>
							<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf4.jpg"/>
						</fig>
					</p>
					<p>
						<fig id="f5">
							<label>Figura 5</label>
							<caption>
								<title>Espectros de XRF de muestras de lápices de colores irradiadas. Tomado de [<xref ref-type="bibr" rid="B25">25</xref>].</title>
							</caption>
							<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf5.jpg"/>
						</fig>
					</p>
				</sec>
			</sec>
			<sec>
				<title>Instrumentos de medición</title>
				<p>Si bien el fenómeno de la generación de rayos X y su emisión sobre la superficie de una muestra son el mismo en todos los tipos de experimentos de XRF, actualmente se cuentan con diferentes equipos involucrados en el análisis. Los espectrómetros de XRF, en general, están compuestos principalmente por una fuente de rayos X, un compartimiento para la muestra, un sistema de detección y el sistema analizador <bold>(</bold><xref ref-type="fig" rid="f6">figura 6</xref><bold>).</bold> De acuerdo con el sistema de detección utilizado, es posible clasificar los espectrómetros XRF en WDXRF y EDXRF. De esta última clasificación es posible encontrar equipos mejorados como lo son los espectrómetros de TXRF, que no serán tratados en la presente revisión bibliográfica.</p>
				<p>
					<fig id="f6">
						<label>Figura 6</label>
						<caption>
							<title>Esquema general de un espectrómetro de XRF. Tomado de [<xref ref-type="bibr" rid="B26">26</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf6.jpg"/>
					</fig>
				</p>
			</sec>
			<sec>
				<title><italic>Espectrómetro de EDXRF</italic></title>
				<p>Los espectrómetros de EDXRF consisten, principalmente, en una fuente de excitación (tubos de rayos X de Rh, Mo, W o Gd, tubos refrigerados por aire o radioisótopos como <sup>125</sup>I, <sup>109</sup>Cd, <sup>241</sup>Am o <sup>238</sup>Pu) [<xref ref-type="bibr" rid="B27">27</xref>], un portamuestras, un sistema de detección de rayos X y un sistema de adquisición de datos. Sea cual sea la fuente de rayos X, el principio básico sigue siendo el mismo: los rayos X primarios inciden en la muestra y los fotones fluorescentes emergentes son registrados por un detector de energía dispersiva (detectores semiconductores de Si(Li) o Ge refrigerados y de diodo PIN), el cual, junto con la electrónica asociada, cuenta y clasifica, según la energía, todos los fotones que le llegan [<xref ref-type="bibr" rid="B28">28</xref>]. Por lo general, el detector sólo dispone de unos pocos microsegundos para el procesamiento de los fotones, de modo que, en algunos casos, los espectrómetros están equipados con filtros para filtrar una parte de la radiación excitadora y así evitar la sobrecarga del detector. Los fotones que inciden sobre el detector producen una gama equivalente de impulsos de tensión que salen del detector y llegan al analizador multicanal, el cual tiene como función clasificar los pulsos para producir un histograma del espectro de energía de rayos X. Todos los espectrómetros incorporarán algún tipo de computador disponible para la extracción espectral, identificación de picos, análisis cuantitativo y una serie de otras funciones útiles [<xref ref-type="bibr" rid="B29">29</xref>].</p>
				<p>En los sistemas de EDXRF son posibles dos configuraciones diferentes para excitar la muestra <bold>(</bold><xref ref-type="fig" rid="f7">figura 7</xref><bold>).</bold> La primera es la excitación directa, en la que el haz de rayos X apunta directamente a la muestra y la segunda es la excitación polarizada, en la que la radiación procedente de la fuente apunta a un objetivo secundario en un ángulo de 45°, el elemento objetivo se excita y emite radiación en un ángulo de 90° que irradia la muestra [<xref ref-type="bibr" rid="B30">30</xref>]. El detector debe estar perpendicular al plano determinado por el tubo, el objetivo y la muestra. El efecto más importante de esta configuración de un espectrómetro de EDXRF es que, al desviar la radiación de rayos X en 90°, la radiación se polariza y se reduce el fondo espectral [<xref ref-type="bibr" rid="B31">31</xref>]. Medir las posiciones de los picos espectrales de fluorescencia ayuda a determinar qué elementos se encuentran en la muestra, y mediante una conversión de las intensidades de radiación a la concentración de elementos, es posible realizar una determinación cuantitativa de los mismos [<xref ref-type="bibr" rid="B32">32</xref>]. Este último proceso se basa en la relación entre la concentración de analito, los rayos X medidos y la intensidad de la fuente de excitación junto con la composición general de la muestra y sus propiedades de absorción.</p>
				<p>
					<fig id="f7">
						<label>Figura 7</label>
						<caption>
							<title>Espectrómetro de EDXRF con A: excitación directa y B: excitación polarizada. Tomada de [<xref ref-type="bibr" rid="B33">33</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf7.png"/>
					</fig>
				</p>
			</sec>
			<sec>
				<title><italic>Espectrómetro de WDXRF</italic></title>
				<p>Los espectrómetros de WDXRF <bold>(</bold><xref ref-type="fig" rid="f8">figura 8</xref><bold>)</bold> consisten en un tubo de rayos X, un filtro, la cámara de la muestra, una máscara de la muestra, el sello de vacío, los colimadores, los cristales analizadores, el goniómetro y el detector o detectores. El tubo de rayos X actúa de manera similar a lo explicado para el espectrómetro de EDXRF, se irradia la muestra de manera directa y la fluorescencia que proviene de la muestra es medida con un sistema de detección de dispersión por longitud de onda. La señal que proviene de la muestra pasa por la máscara del espectrómetro, la cual elimina las señales no deseadas, y posteriormente pasa por el sello de vacío, que separa la cámara de la muestra de la cámara del goniómetro. Durante el ingreso de una muestra, el sello se cierra y la cámara del goniómetro permanece en vacío. Así, solo un pequeño volumen de la cámara de la muestra debe evacuarse cuando se van a medir sólidos o inundarse con helio cuando se van a medir líquidos.</p>
				<p>
					<fig id="f8">
						<label>Figura 8</label>
						<caption>
							<title>Partes de un espectrómetro de WDXRF. Tomado de [<xref ref-type="bibr" rid="B34">34</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf8.png"/>
					</fig>
				</p>
				<p>Cuando la señal llega a los colimadores, estos dirigen y canalizan los rayos X policromáticos fluorescentes, provenientes de la muestra, hacia los cristales. Los colimadores pueden mejorar la resolución al restringir los ángulos en los que los rayos X fluorescentes inciden en el cristal y, así mismo, pueden mejorar la sensibilidad al ampliar los ángulos en los que inciden los rayos X sobre el cristal. Los cristales de un espectrómetro WDXRF <bold>(</bold><xref ref-type="table" rid="t2">tabla 2</xref><bold>)</bold> difractan los rayos X con diferentes longitudes de onda, como un prisma. El ángulo de incidencia de los rayos X fluorescentes en el cristal de análisis es importante para cumplir la ley de difracción de Bragg <bold>(</bold><xref ref-type="fig" rid="f9">figura 9</xref><bold>),</bold> ya que, para una longitud de onda determinada, el cristal refleja los rayos X hacia el detector. Para mantener las condiciones geométricas requeridas, se utiliza un goniómetro que tiene como función garantizar que el ángulo entre la fuente y el cristal y entre el cristal y el detector se mantenga igual [<xref ref-type="bibr" rid="B35">35</xref>].</p>
				<p>
					<table-wrap id="t2">
						<label>Tabla 2</label>
						<caption>
							<title>Cristales analizadores usados en WDXRF. Tomado de [<xref ref-type="bibr" rid="B36">36</xref>].</title>
						</caption>
						<table>
							<colgroup>
								<col/>
								<col/>
								<col/>
							</colgroup>
							<thead>
								<tr>
									<th align="center">Cristal</th>
									<th align="center">Nombre del material</th>
									<th align="center">2d (nm)</th>
								</tr>
							</thead>
							<tbody>
								<tr>
									<td align="center">LiF (200)</td>
									<td align="center">Fluoruro de litio</td>
									<td align="center">0,403</td>
								</tr>
								<tr>
									<td align="center">LiF (220)</td>
									<td align="center">Fluoruro de litio</td>
									<td align="center">0,285</td>
								</tr>
								<tr>
									<td align="center">LiF (420)</td>
									<td align="center">Fluoruro de litio</td>
									<td align="center">0,180</td>
								</tr>
								<tr>
									<td align="center">Ge</td>
									<td align="center">Germanio</td>
									<td align="center">0,653</td>
								</tr>
								<tr>
									<td align="center">TIAP</td>
									<td align="center">Biftalato de talio</td>
									<td align="center">2,576</td>
								</tr>
								<tr>
									<td align="center">PET</td>
									<td align="center">Pentaeritrito</td>
									<td align="center">0,874</td>
								</tr>
								<tr>
									<td align="center">XS-B</td>
									<td align="center">La/B4C multicapa</td>
									<td align="center">19,0</td>
								</tr>
								<tr>
									<td align="center">XS-C</td>
									<td align="center">TiO2/C multicapa</td>
									<td align="center">12,0</td>
								</tr>
								<tr>
									<td align="center">XS-N</td>
									<td align="center">Ni/BN multicapa</td>
									<td align="center">11,0</td>
								</tr>
								<tr>
									<td align="center">XS-55</td>
									<td align="center">W/Si multicapa</td>
									<td align="center">5,5</td>
								</tr>
								<tr>
									<td align="center">XS-CEM</td>
									<td align="center">Estructura específica</td>
									<td align="center">2,75</td>
								</tr>
								<tr>
									<td align="center">ADP</td>
									<td align="center">Fosfato dihidrógeno de amonio</td>
									<td align="center">1,064</td>
								</tr>
								<tr>
									<td align="center">InSb</td>
									<td align="center">Antimoniuro de indio</td>
									<td align="center">0,748</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
				<p>
					<fig id="f9">
						<label>Figura 9</label>
						<caption>
							<title>Diagrama de la ley de Bragg. Tomado de [<xref ref-type="bibr" rid="B37">37</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf9.png"/>
					</fig>
				</p>
				<p>Cuando la señal de los rayos X, que tiene una longitud de onda específica proveniente de los cristales, llega al detector, este la convierte en una intensidad para la muestra analizada. Los detectores más utilizados en los espectrómetros de WDXRF son el contador de flujo proporcional (para medir elementos pesados) y los contadores de centelleo (para medir elementos livianos). Este análisis puede hacerse midiendo la intensidad de los rayos X en diferentes longitudes de onda, una tras otra (secuencial) o en posiciones fijas, es decir, todas al mismo tiempo (simultánea) [<xref ref-type="bibr" rid="B38">38</xref>].</p>
			</sec>
			<sec>
				<title><italic>Espectrómetro de XRF portátil</italic></title>
				<p>Un espectrómetro portátil de XRF, a veces conocido como pistola XRF portátil <bold>(</bold><xref ref-type="fig" rid="f10">figura 10</xref><bold>),</bold> se utiliza para determinar la composición química de materiales, especialmente en el control de procesos y calidad en cualquier punto de las operaciones de fabricación, o para analizar chatarra en los puntos de entrega antes de que ingrese a la cadena de suministro [<xref ref-type="bibr" rid="B39">39</xref>], o incluso para verificar el peso en quilates y el valor de las joyas de oro. Su importancia radica en que permite el análisis directo de las muestras sin necesidad de realizar ningún pretratamiento de las mismas. Esto hace atractivos a los equipos portátiles para el análisis químico de piezas de arte, mediciones in situ, entre otras aplicaciones que requieren de mediciones rápidas y de análisis inmediato de los resultados.</p>
				<p>
					<fig id="f10">
						<label>Figura 10</label>
						<caption>
							<title>Partes de un espectrómetro de XRF portátil. Tomado de [<xref ref-type="bibr" rid="B42">42</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf10.png"/>
					</fig>
				</p>
				<p>Los espectrómetros de XRF portátiles tienen el mismo principio de funcionamiento que los espectrómetros de EDXRF y WDXRF, solo que manejan una geometría diferente. Consisten básicamente en un tubo de rayos X, un detector, un procesador digital, una CPU, una pantalla táctil y un puerto USB. En los sistemas portátiles, el tubo de rayos X crea un haz de rayos X con suficiente energía para impactar los electrones en las capas internas de los átomos de una muestra. Luego, el haz de rayos X se emite desde la parte frontal del analizador XRF portátil [<xref ref-type="bibr" rid="B40">40</xref>]. El haz de rayos X interactúa con los átomos de la muestra y desplaza los electrones de las capas orbitales internas del átomo; después, la radiación secundaria que emite la muestra es capturada por el detector, que usualmente es de dispersión de energía, el cual transforma esa energía en pulsos electrónicos y los envía al preamplificador. El preamplificador amplifica las señales y las envía al procesador de señal digital (DSP), el cual recopila y digitaliza los pulsos de rayos X y envía los datos espectrales a la CPU principal, allí se procesan los datos espectrales para producir un análisis de composición detallado [<xref ref-type="bibr" rid="B41">41</xref>]. Los datos de composición y demás información importante de la medición se almacenan en la memoria del espectrómetro, para recuperarlos o descargarlos posteriormente a una USB externa o pasarlos a un computador.</p>
			</sec>
			<sec>
				<title>Análisis por XRF</title>
			</sec>
			<sec>
				<title><italic>Aspectos de la preparación de la muestra</italic></title>
				<p>Las muestras químicamente homogéneas, con una superficie plana, pueden ser analizadas por XRF sin necesidad de un tratamiento previo. Sin embargo, esta muestra ideal es poco común, ya que la mayoría de las muestras sólidas requieren de algún tipo de pretratamiento como pulverización, homogeneización y secado, para posteriormente ser preparadas como polvos sueltos, polvos prensados (pellets) o perlas fundidas, tal como se muestra en la <xref ref-type="fig" rid="f11">figura 11</xref><bold>.</bold> En la <xref ref-type="table" rid="t3">tabla 3</xref> se presentan varios ejemplos de preparación de muestras como polvo suelto, polvo prensado o perlas fundidas, para diferentes matrices que pueden ser medidas por XRF.</p>
				<p>
					<fig id="f11">
						<label>Figura 11</label>
						<caption>
							<title>Muestras sólidas para el análisis por XRF. A: polvo suelto, tomado de [<xref ref-type="bibr" rid="B51">51</xref>]; B: polvo prensado; y C: perla de fundida. Tomado de [<xref ref-type="bibr" rid="B52">52</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf11.png"/>
					</fig>
				</p>
				<p>
					<table-wrap id="t3">
						<label>Tabla 3</label>
						<caption>
							<title>Preparación de muestras sólidas en el análisis de fluorescencia de rayos X (XRF) de diversas matrices.</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gt3.jpg"/>
						<table-wrap-foot>
							<fn id="TFN1">
								<p>fd: factor de dilución. </p>
							</fn>
							<fn id="TFN2">
								<p>m: masa de la muestra.</p>
							</fn>
							<fn id="TFN3">
								<p>d: diámetro. </p>
							</fn>
							<fn id="TFN4">
								<p>p: presión de prensado.</p>
							</fn>
							<fn id="TFN5">
								<p>ag: aglutinante. </p>
							</fn>
							<fn id="TFN6">
								<p>mp: masa de la perla.</p>
							</fn>
						</table-wrap-foot>
					</table-wrap>
				</p>
				<p>La técnica de preparación de la muestra se selecciona de acuerdo con el propósito analítico y la precisión requerida del estudio. Para determinar la mejor metodología de preparación, se debe tener conocimiento en las técnicas de tratamiento de las muestras (matriz de análisis), es decir, se debe realizar una optimización de los parámetros de preparación, tales como la cantidad de muestra, la presión, el tiempo de prensado (para los polvos prensados) y el tiempo de fusión (para perlas fundidas), con el objetivo de asegurar que se selecciona el método que da resultados más fiables <bold>(</bold><xref ref-type="fig" rid="f12">figura 12</xref><bold>).</bold> En este sentido, se debe establecer si una técnica se puede aplicar a diferentes tipos de matrices o si, por el contrario, una matriz de análisis sólo permite una preparación específica de muestra, como en el caso de los aceros, arcillas y cementos, cuya preparación más común es la perla fundida, o para algunos alimentos y suelos, cuya preparación es por polvos prensados. Las perlas fundidas son las más homogéneas entre estos tipos de preparación de muestras y son las menos afectadas por el efecto matriz (la absorción y el aumento de los rayos X por parte de los componentes).</p>
				<p>
					<fig id="f12">
						<label>Figura 12</label>
						<caption>
							<title>Orden ascendente de fiabilidad en la preparación de muestras para el análisis por XRF. Elaborado a partir de [<xref ref-type="bibr" rid="B53">53</xref>, <xref ref-type="bibr" rid="B54">54</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf12.png"/>
					</fig>
				</p>
			</sec>
			<sec>
				<title><italic>Pretratamiento de la muestra</italic></title>
			</sec>
			<sec>
				<title><bold>Efecto <italic>de la homogenización y el tamaño de</italic> partícula</bold></title>
				<p>Los materiales sólidos de composición multielemental como suelos, rocas, alimentos, entre otros, presentan, en su mayoría, una morfología heterogénea en cuanto a tamaño, textura y estado en el que se encuentran, por lo que algunos componentes de las muestras pueden no determinarse con precisión mediante la medición directa por XRF. Estas muestras sólidas heterogéneas requieren una cuidadosa homogeneización, mediante pulverización y mezcla, para convertirlas en un polvo fino que minimice los efectos indeseados y permita el procesamiento de la muestra, ya sea como polvos prensados o perlas fundidas [<xref ref-type="bibr" rid="B55">55</xref>]. Para estos casos es común hacer uso de equipos de molienda, como morteros [<xref ref-type="bibr" rid="B56">56</xref>] y molinos [<xref ref-type="bibr" rid="B57">57</xref>], que son fabricados de diversos tamaños y materiales tales como ágata [<xref ref-type="bibr" rid="B58">58</xref>], alúmina, acero [<xref ref-type="bibr" rid="B59">59</xref>], carburo de tungsteno, carburo de aluminio [<xref ref-type="bibr" rid="B60">60</xref>], circonio, entre otros.</p>
				<p>Cuando se utiliza un equipo de molienda (por ejemplo, un molino de bolas), se debe considerar que tanto el material de fabricación de las bolas como la cantidad de muestra que se va a moler sean las adecuadas para evitar contaminación, ya que se podría transferir la composición de las bolas y del molino a la muestra, o puede que la muestra no sea pulverizada adecuadamente. En algunos casos, es mejor realizar este tipo de trituraciones o pulverización en un mortero, para así evitar pérdidas que disminuyan el rendimiento de la molienda; esto dependerá del tipo de muestra, su dureza y la cantidad de muestra que se desee homogenizar. Para trituración, maceración, molienda u homogenización en alimentos, se suele hacer uso de los morteros de ágata o de carburo de tungsteno que no son tan agresivos con la muestra, como por ejemplo en el estudio realizado por Jolly et al. [<xref ref-type="bibr" rid="B61">61</xref>], quienes usaron un mortero de carburo de tungsteno para la molienda de unas muestras de leche previamente calcinadas. En el trabajo de Chubarov <italic>et al.,</italic> utilizaron un mortero de ágata para moler muestras de suelo hasta alcanzar un tamaño de partícula inferior a 75 μm[<xref ref-type="bibr" rid="B62">62</xref>].</p>
				<p>Para los análisis cuantitativos, se deben mantener las mismas condiciones de pulverización (cantidad de muestra y tiempo de pulverización) tanto para los materiales de referencia (MR) o MRC como para las muestras de concentración desconocida, cuando se identifique que el tamaño de partícula no es el adecuado para las mediciones por XRF. Es muy importante tener en cuenta que los tiempos de pulverización o molienda varían desde segundos hasta minutos y que dependen de la naturaleza de la muestra. La relación entre la intensidad de los rayos X y el tiempo de pulverización es crucial, ya que, a mayor tiempo de pulverización, menor tamaño de partícula y, por lo tanto, mayor intensidad [<xref ref-type="bibr" rid="B63">63</xref>]. En el estudio realizado por Morikawa [<xref ref-type="bibr" rid="B63">63</xref>], se buscó evaluar la relación entre la intensidad de los rayos X para la línea Si-Kα y el tiempo de pulverización para una muestra de dióxido de silicio (SiO<sub>2</sub>) (<xref ref-type="fig" rid="f13">ver <bold>figura 13)</bold></xref>la cual fue pulverizada en un mortero de carburo de tungsteno hasta obtener un tamaño de partícula menor a 50 μm. En esta figura se evidencia que, para obtener análisis precisos con esta matriz, el tiempo de pulverización recomendado es de 5 min.</p>
				<p>
					<fig id="f13">
						<label>Figura 13</label>
						<caption>
							<title>Relación entre el tiempo de pulverización y la intensidad de los rayos X. Elaborado a partir de [<xref ref-type="bibr" rid="B63">63</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf13.png"/>
					</fig>
				</p>
				<p>Para la homogenización de una muestra de arroz de marca comercial (de Colombia) realizada en el Instituto Nacional de Metrología (INM), se llevaron a cabo ciertos procedimientos hasta obtener el tamaño de partícula deseado (&lt; 100 μm). En primera medida, los granos se molieron en un triturador de comida marca NutriBullet Baby<sup>®</sup>, donde se obtuvieron tamaños de partícula &lt; 350 μm para la fracción minoritaria y &gt; 500 μm para la fracción mayoritaria (tamiz n.° 45). Se observó que el rendimiento relativo (fracción minoritaria (g)/muestra inicial de arroz (g)) de la primera molienda no fue lo suficientemente alto (&lt; 50%) con este triturador de comida, por lo cual se eligió el molino de impacto de rotor SR300, marca Retsch, para moler 200 g de granos de arroz en un tiempo inferior a un minuto. Con esta molienda se obtuvo un polvo fino, con tamaño de partícula inferior a 100 μm (tamiz n.° 170). Los granos de arroz presentaron un aspecto visiblemente homogéneo después de la molienda <bold>(</bold><xref ref-type="fig" rid="f14">figura 14</xref><bold>).</bold></p>
				<p>
					<fig id="f14">
						<label>Figura 14</label>
						<caption>
							<title>Molienda de muestras de arroz hasta obtener tamaños de grano &lt; 100 μm.</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf14.png"/>
					</fig>
				</p>
				<p>Para determinar la homogeneidad química de las muestras pulverizadas, se debe hacer una estimación experimental a partir de la cantidad total de la muestra de polvo y del volumen de muestreo. Esta homogeneidad puede estimarse de forma sencilla de la siguiente manera: primero, preparar aproximadamente cinco a diez submuestras de la muestra de polvo y analizarlas con un espectrómetro de XRF; a continuación, calcular la variación en los resultados utilizando la desviación estándar relativa (RSD) de la intensidad de los rayos X fluorescentes de cada analito; finalmente, la RSD se compara con la estadística teórica de los rayos X estimada a partir de la intensidad de los rayos X fluorescentes y el tiempo de recuento [<xref ref-type="bibr" rid="B64">64</xref>]. De esta manera, será posible evaluar la homogeneidad química de los analitos de interés en la muestra, después de molida o pulverizada, hasta el tamaño de partícula requerido.</p>
				<p>En el estudio realizado por Chuparina <italic>et al.,</italic> evaluaron el efecto que tiene la variación del tamaño de partícula en la heterogeneidad de la determinación de óxidos de Na, Mg, Al, Si, P, K, Ca, Ti, Mn y Fe en residuos de carbón [<xref ref-type="bibr" rid="B47">47</xref>]; la variación de estas desviaciones depende notablemente de la preparación de la muestra y, por lo tanto, del tamaño de partícula <bold>(</bold><xref ref-type="fig" rid="f15">figura 15</xref><bold>).</bold> En esta figura se muestran tres intervalos de tamaño de partícula donde, para el primer intervalo (125 a 250 μm), es notable una alta heterogeneidad que resulta de la variedad de tamaños que presentan los óxidos analizados; en el segundo intervalo la heterogeneidad disminuye; y en el último intervalo, cuando la muestra de residuo de carbón se homogeneizó y se preparó con un tamaño de partícula &lt; 50 μm, las variaciones en la RSD disminuyeron en gran medida al controlar mejor el tamaño de la partícula.</p>
				<p>
					<fig id="f15">
						<label>Figura 15</label>
						<caption>
							<title>Desviación estándar relativa (% RSD) de la determinación por XRF de óxidos de Na, Mg, Al, Si, P, K, Ca, Ti, Mn y Fe en muestras prensadas para diferentes tamaños de partículas. Tomado de [<xref ref-type="bibr" rid="B47">47</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf15.png"/>
					</fig>
				</p>
				<sec>
					<title><bold>Efecto del <italic>secado y la calcinación</italic>
</bold></title>
					<p>El secado de la muestra de interés, que se desea medir por XRF, es otro de los parámetros que se debe tener en cuenta para obtener resultados confiables. La presencia de agua (humedad) afecta no solo la preparación de los polvos prensados y de las perlas fundidas, sino que, al momento de realizar una medición, disminuye la intensidad de las señales obtenidas por XRF para los analitos y, por lo tanto, el valor medido disminuye [<xref ref-type="bibr" rid="B65">65</xref>]. Al preparar un polvo prensado a partir de una muestra húmeda, la muestra se calienta por la irradiación con los rayos X primarios, lo que puede ocasionar que esta se agriete o se rompa; además, el polvo puede estallar cuando se mide bajo una atmósfera de vacío. Por lo tanto, cuando se preparan polvos sueltos y polvos prensados, la muestra se debe secar primero para eliminar humedad.</p>
					<p>Las condiciones de secado de una muestra (método, temperatura y tiempo de secado) pueden establecerse de acuerdo con los estudios realizados por otros autores, es decir, lo que reporta la bibliografía; esto incluye implementar las condiciones de secado que se definen en el certificado de un MRC, siempre y cuando la matriz de análisis sea similar a la del MRC. En el INM, para la preparación de polvos prensados de matrices alimenticias como harina de arroz y harina de trigo, se han tomado como referencia el tiempo y temperatura de secado descritos en el certificado del MRC 1568b rice <italic>flour</italic> [<xref ref-type="bibr" rid="B66">66</xref>] y del MRC 1567b wheat <italic>flour</italic> [<xref ref-type="bibr" rid="B67">67</xref>], respectivamente, secando las muestras en un horno de convección por gravedad marca Binder, a una temperatura de 90 °C durante 2 h. Así mismo, cuando se requieran preparar polvos prensados de un MRC, es necesario seguir las recomendaciones dadas en los certificados para mantener la trazabilidad de las mediciones. Kulail <italic>et al.,</italic> en su estudio para determinar trazas de algunos elementos como Fe, Mn y Co en plantas medicinales, utilizaron el MRC 1573a <italic>tomato leaves</italic> para evaluar la exactitud tanto en términos de veracidad como de sesgo. En este estudio secaron las muestras de hojas de tomate a 60 °C hasta que obtuvieron un peso constante; sin embargo, las condiciones de secado descritas en el certificado del Instituto Nacional de Estándares y Tecnología (NIST) dicen que se debe liofilizar el material durante 24 h a un vacío de 13,3 Pa. Los resultados de las mediciones muestran sesgos de 17,91, 12,42 y 25,60% para Fe, Mn y Co, respectivamente [<xref ref-type="bibr" rid="B68">68</xref>], que pueden atribuirse a no utilizar las condiciones establecidas por el NIST para el secado del MRC, puesto que los valores medidos por XRF fueron menores a los certificados.</p>
					<p>Ahora bien, en algunas situaciones no solo basta con secar la muestra, sino que es necesario utilizar otro pretratamiento como la calcinación, bien sea para concentrar los analitos de interés, eliminar los elementos interferentes o concomitantes de la matriz de la muestra, o para una mejor preparación del polvo prensado. Esto es necesario cuando la muestra es de difícil manejo, por ejemplo, muestras de chocolate. Un ejemplo es el estudio realizado por Chitkara et al., en el cual tomaron 100 g de una barra energética con chocolate y la dispusieron en crisoles para ser sometida a calcinación en una mufla a una temperatura de 500 a 600 °C. Posteriormente, la ceniza se dejó enfriar en la mufla durante 24 a 30 h hasta que alcanzó la temperatura ambiente, para luego preparar un polvo prensado [<xref ref-type="bibr" rid="B69">69</xref>].</p>
					<p>Para la preparación de perlas fundidas, la muestra se usa comúnmente calcinada, para eliminar elementos volátiles que pueden ocasionar que se agrieten, se rompan o desvitrifiquen las perlas fundidas. También se calcina la muestra para oxidar materiales reductores, presentes en ciertos metales como el azufre, que de una u otra manera pueden dañar el crisol de Pt-Au en el proceso de fusión [<xref ref-type="bibr" rid="B70">70</xref>]. En la industria del cemento, es muy común preparar perlas fundidas para los análisis por XRF. Tal es el caso del trabajo de grado realizado por Venegas, quien para la elaboración de perlas fundidas de cemento calcinó 1 g de cada muestra en un crisol de titanio por 10 min, en una mufla a 1000 °C, determinó la pérdida por ignición y realizó el cálculo de la relación ceniza/fundente, necesario para preparar la perla fundida [<xref ref-type="bibr" rid="B71">71</xref>].</p>
				</sec>
			</sec>
			<sec>
				<title><bold>Efecto del <italic>espesor y del diámetro de la muestra</italic>
</bold></title>
				<p>El espesor de la muestra (masa por unidad de superficie) es un factor importante para el análisis confiable por XRF, es importante que las muestras tengan un espesor adecuado para evitar errores analíticos derivados de los efectos de absorción de la muestra. Cuando se analizan rayos X fluorescentes de alta energía de elementos pesados, en muestras que contienen elementos ligeros, la profundidad analítica puede superar el espesor de la muestra [<xref ref-type="bibr" rid="B72">72</xref>]. En este caso, el espesor se vuelve incluso más importante que el tamaño de las partículas, porque la intensidad de los rayos X fluorescentes aumenta con el espesor hasta la profundidad analítica. El problema de la profundidad analítica respecto al espesor de la muestra se produce con frecuencia en los siguientes análisis: 1) muestras compuestas principalmente por elementos ligeros con pequeños coeficientes de absorción de masa; 2) rayos X fluorescentes de alta energía como los espectros K de elementos pesados; 3) muestras de baja densidad como polvos sueltos, y 4) muestras delgadas. Respecto al diámetro de la muestra, también es un parámetro que influye en las intensidades de los rayos X fluorescentes de forma similar al espesor de la muestra [<xref ref-type="bibr" rid="B73">73</xref>].</p>
				<p>En el estudio realizado por Inui <italic>et al.,</italic> se evaluó la relación que hay entre las intensidades de los rayos X fluorescentes y el espesor, utilizando granos de arroz blanco y marrón que contenían 10 mg/kg de Cd. La <xref ref-type="fig" rid="f16">figura 16</xref> muestra la variación de la intensidad de Cd-Kα según el espesor de la muestra. Los autores concluyeron en su estudio que las intensidades de Cd-Kα, en los granos de arroz blanco y marrón, aumentaron gradualmente con el aumento del espesor de la muestra, hasta 0,87 g/cm (utilizando 7 g de muestra) [<xref ref-type="bibr" rid="B74">74</xref>]. De igual manera, ellos evaluaron en su estudio el efecto del diámetro de la muestra, variaron el diámetro del colimador de 1 a 30 mm y observaron que, cuando el diámetro del colimador era inferior a 10 mm, la intensidad del Cd-Kα era débil, causando un % de RSD entre el 15 y el 5%. Para diámetros superiores a 10 mm, observaron un incremento directamente proporcional con las intensidades de la línea de emisión del Cd, tal como se muestra en la <xref ref-type="fig" rid="f16">figura 16</xref><bold>,</bold> por lo que los autores concluyeron que el diámetro óptimo de la muestra y, por ende, del colimador es de 30 mm, ya que consiguieron intensidades más altas, así como % de RSD más bajos (inferiores al 2%).</p>
				<p>
					<fig id="f16">
						<label>Figura 16</label>
						<caption>
							<title>Variaciones de las intensidades de rayos X fluorescentes de Cd-Kα en el grano de arroz marrón y en el grano de arroz blanco con A: el espesor de las muestras y B: el diámetro de la muestra. Tomado de [<xref ref-type="bibr" rid="B74">74</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf16.png"/>
					</fig>
				</p>
				<sec>
					<title><italic>Preparación de las muestras antes de la medición</italic></title>
				</sec>
				<sec>
					<title><italic>Medición directa</italic></title>
					<p>La medición directa puede ser utilizada en el análisis de algunas muestras sólidas, especialmente cuando la muestra no debe ser destruida. Por ejemplo, el hierro, el acero y sus aleaciones pueden analizarse de forma no destructiva mediante mediciones directas por XRF para el control de procesos y la clasificación de productos [<xref ref-type="bibr" rid="B75">75</xref>]. En Japón, las normas industriales especifican que el pretratamiento y el análisis de muestras del hierro, el acero y sus aleaciones se miden directamente por XRF [<xref ref-type="bibr" rid="B76">76</xref>, 77].</p>
					<p>Por simplicidad y conveniencia, la selección y los análisis <italic>in situ</italic> suelen realizarse mediante medición directa por XRF, sin que se prepare la muestra. Por ejemplo, los constituyentes metálicos peligrosos en suelos [<xref ref-type="bibr" rid="B78">78</xref>], en plásticos [<xref ref-type="bibr" rid="B79">79</xref>] y en componentes electrónicos [<xref ref-type="bibr" rid="B80">80</xref>] se analizan normalmente por medición directa. De igual manera, objetos preciosos y joyería, artefactos arqueológicos y piezas de arte <bold>(</bold><xref ref-type="fig" rid="f17">figura 17</xref><bold>)</bold> suelen analizarse de forma no destructiva mediante XRF (incluyendo los dispositivos portátiles) [<xref ref-type="bibr" rid="B81">81</xref>, 82].</p>
					<p>
						<fig id="f17">
							<label>Figura 17</label>
							<caption>
								<title>Medición de piezas de arte con un espectrómetro de EDXRF portátil. Tomado de [<xref ref-type="bibr" rid="B83">83</xref>].</title>
							</caption>
							<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf17.png"/>
						</fig>
					</p>
					<p>La medición directa de las muestras en XRF no solo se aplica en los casos mencionados anteriormente, también ha sido implementada en el análisis de alimentos. Autores como Inui <italic>et al.</italic> han realizado análisis de muestras de granos de arroz por WDXRF por medición directa, donde buscaban determinar la concentración de cadmio en las muestras de arroz [<xref ref-type="bibr" rid="B74">74</xref>].</p>
				</sec>
			</sec>
			<sec>
				<title>Polvo suelto</title>
				<p>Para el análisis de muestras que deben recuperarse después de la medición, o muestras en polvo como el grafito y la mica, que son difíciles de preparar en polvos prensados (incluso utilizando aglutinantes), la muestra puede medirse en atmósfera de vacío por el método de polvo suelto, así mantiene su condición original, sin necesidad de alta presión ni un proceso de fusión. El análisis de material en polvo suelto generalmente requiere que la muestra se coloque en una copa para muestras líquidas con una película como soporte (Prolene, PP Mylar ®, entre otros) <bold>(</bold><xref ref-type="fig" rid="f18">figura 18</xref><bold>).</bold> Esto asegura una superficie plana para que la muestra sea irradiada con los rayos X. Cuanto más pequeño es el tamaño de partícula de la muestra (&lt; 100 μm), más probable es que sea homogénea y que los espacios vacíos sean limitados, esto permite hacer una medición directa del polvo sin necesidad de preparar un <italic>pellet</italic> o una perla. Para ello se debe usar suficiente muestra en polvo, esto asegura que se obtenga un espesor infinito para todos los elementos de interés. Este requisito se puede cumplir utilizando 15 g de muestra para la mayoría de los materiales [<xref ref-type="bibr" rid="B84">84</xref>].</p>
				<p>
					<fig id="f18">
						<label>Figura 18</label>
						<caption>
							<title>Preparación de una muestra de polvo suelto de harina de arroz para el análisis por XRF.</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf18.png"/>
					</fig>
				</p>
				<p>Los polvos sueltos tienen varias desventajas que requieren atención. En primera medida, hay que tener en cuenta que los rayos X fluorescentes de menor energía (especialmente de elementos como Na, Mg, etc.) son absorbidos considerablemente por la película o film y, por lo tanto, disminuye su intensidad <bold>(</bold><xref ref-type="fig" rid="f19">figura 19</xref><bold>)</bold> [<xref ref-type="bibr" rid="B81">81</xref>]. Esta absorción de rayos X podría corregirse, en cierta medida, con un cálculo teórico, utilizando parámetros como la composición elemental, el espesor de la película <bold>(</bold><xref ref-type="table" rid="t4">tabla 4</xref><bold>),</bold> entre otros. En segundo lugar, la reproducibilidad en la preparación de muestras en polvo suelto no es tan alta en comparación con la del método de polvo prensado [<xref ref-type="bibr" rid="B85">85</xref>], esto se debe a que las densidades de empaquetado son variables y las superficies analíticas son gruesas. En tercer lugar, el resultado analítico puede ser poco fiable cuando los polvos y los granos tienen composiciones elementales heterogéneas.</p>
				<p>
					<fig id="f19">
						<label>Figura 19</label>
						<caption>
							<title>Índices de transmisión de rayos X de varias películas usadas en la preparación de polvos sueltos. Tomado de [<xref ref-type="bibr" rid="B86">86</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf19.png"/>
					</fig>
				</p>
				<p>
					<table-wrap id="t4">
						<label>Tabla 4</label>
						<caption>
							<title>Lista de películas poliméricas más usadas en preparación de polvos sueltos. Tomado de [<xref ref-type="bibr" rid="B87">87</xref>].</title>
						</caption>
						<table>
							<colgroup>
								<col/>
								<col/>
							</colgroup>
							<thead>
								<tr>
									<th align="center">Nombre</th>
									<th align="center">Espesor (μm)</th>
								</tr>
							</thead>
							<tbody>
								<tr>
									<td align="left">Ultra-Poliéster</td>
									<td align="left">1,5</td>
								</tr>
								<tr>
									<td align="left">Mylar®</td>
									<td align="left">2,5</td>
								</tr>
								<tr>
									<td align="left">Mylar®</td>
									<td align="left">3,6</td>
								</tr>
								<tr>
									<td align="left">EntonProlene®</td>
									<td align="left">4,0</td>
								</tr>
								<tr>
									<td align="left">Polipropileno</td>
									<td align="left">6,0</td>
								</tr>
								<tr>
									<td align="left">Kapton</td>
									<td align="left">7,5</td>
								</tr>
								<tr>
									<td align="left">Polipropileno</td>
									<td align="left">12,0</td>
								</tr>
								<tr>
									<td align="left">Polipropileno</td>
									<td align="left">6,0</td>
								</tr>
								<tr>
									<td align="left">Poliéster</td>
									<td align="left">6,0</td>
								</tr>
							</tbody>
						</table>
						<table-wrap-foot>
							<fn id="TFN7">
								<p>Mylar y Kapton: marca registrada por Du Pont, EE. UU.</p>
							</fn>
							<fn id="TFN8">
								<p>Prolene: marca registrada por Chemplex, EE. UU.</p>
							</fn>
						</table-wrap-foot>
					</table-wrap>
				</p>
			</sec>
			<sec>
				<title><italic>Polvos prensados</italic></title>
				<p>Los polvos prensados son una preparación relativamente sencilla, que busca moldear y prensar un polvo fino. La muestra en polvo se ubica en una matriz de compactación, posteriormente se somete a presión y así se obtiene la muestra prensada <bold>(</bold><xref ref-type="fig" rid="f20">figura 20</xref><bold>).</bold> La facilidad de compactación de la muestra depende de sus características, del tamaño de partícula, del tiempo de prensado y de la presión de compactación.</p>
				<p>
					<fig id="f20">
						<label>Figura 20</label>
						<caption>
							<title>Esquema general de la compactación de una muestra de harina de arroz utilizando una prensa manual.</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf20.png"/>
					</fig>
				</p>
				<p>La preparación de una muestra en polvos prensados es más rigurosa que verter polvos sueltos en una copa para muestra, pero es muy recomendada porque los resultados son más precisos y reproducibles; esto se debe a que las partículas son más uniformes en tamaño y forma, lo que garantiza que, durante la compactación, el polvo se distribuya uniformemente y se obtenga una superficie adecuadamente plana. Adicionalmente, el prensado mejora la durabilidad de la muestra, lo que permite la medición de rayos X fluorescentes de baja energía de elementos ligeros en condiciones de vacío.</p>
				<p>La preparación de polvos prensados requiere una atención considerable al tamaño heterogéneo de las partículas y a la composición química de la muestra, ya que utilizar tamaños de partícula mayores a 100 μm [<xref ref-type="bibr" rid="B88">88</xref>] podría causar variaciones en la intensidad de los rayos X fluorescentes, lo que llevaría a resultados erróneos, tal como se mencionó en la sección &quot;Efecto de la homogenización y el tamaño de partícula&quot;. Para asegurar una alta precisión y reproducibilidad, la homogeneidad de la muestra pulverizada debe ser examinada adecuadamente, especialmente cuando se determinan elementos ligeros con poca profundidad analítica. Además, antes de la preparación, el polvo debe secarse para eliminar los componentes húmedos y volátiles, como se describe en la sección &quot;Efecto del secado y la calcinación&quot;; si se omite este paso, el polvo prensado puede resultar dañado durante la medición por XRF.</p>
				<p>Los polvos, que son difíciles de compactar por sí solos, requieren del uso de un aglutinante para facilitar la compactación. Medir una muestra que no está lo suficientemente compacta puede generar que las partículas del polvo fino se desprendan y contaminen la cámara de la muestra del espectrómetro, especialmente si la medición se realiza en el modo de vacío. Los polvos cuyas partículas tienen forma esférica, como el SiCh o las cenizas, son difíciles de prensar y la proporción de la mezcla muestra-aglutinante suele ser de 10:1 o 10:2. Es muy importante determinar la pureza del aglutinante, ya que hay que seleccionar un aglutinante que no incluya los elementos que se van a analizar. Los más utilizados son la cera [<xref ref-type="bibr" rid="B89">89</xref>], los polvos a base de poliestireno, los polvos de ácido bórico [<xref ref-type="bibr" rid="B90">90</xref>] y la celulosa [<xref ref-type="bibr" rid="B91">91</xref>].</p>
				<p>Como se mencionó anteriormente, la presión de compactación es una variable a tener en cuenta en la preparación de polvos prensados, esto se debe a que la intensidad de los rayos X cambia en función de esta variable. La <xref ref-type="fig" rid="f21">figura 21 </xref>muestra la relación entre la presión de compactación y la intensidad de los rayos X para una muestra de cemento. En este gráfico se evidencia que la intensidad de los rayos X aumenta con la presión aplicada, debido a que aumenta la densidad de la muestra. Por encima de una determinada presión, la intensidad de los rayos X se satura. Los errores debidos a este efecto pueden minimizarse manteniendo constantes la cantidad de muestra y la presión de compactación para cada polvo prensado que se prepare. Para obtener resultados reproducibles, lo más recomendado es que la muestra se compacte a la presión en la que se satura la intensidad de los rayos X [<xref ref-type="bibr" rid="B92">92</xref>].</p>
				<p>
					<fig id="f21">
						<label>Figura 21</label>
						<caption>
							<title>Relación entre la presión de compactación y la intensidad de los rayos X en una muestra de cemento. Elaborado a partir de [<xref ref-type="bibr" rid="B92">92</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf21.png"/>
					</fig>
				</p>
			</sec>
			<sec>
				<title><bold>Perlas <italic>fundidas</italic>
</bold></title>
				<p>La preparación en general de muestras por perlas fundidas <bold>(</bold><xref ref-type="fig" rid="f22">figura 22</xref><bold>)</bold> se realiza de la siguiente manera: inicialmente se pesa la muestra, finamente pulverizada y seca, junto con el fundente (por ejemplo, tetraborato de litio [<xref ref-type="bibr" rid="B93">93</xref>], metaborato de litio, o una mezcla de metaborato y tetraborato). En algunas situaciones se pesa un agente oxidante, si las muestras a fundir presentan alto contenido de carburos, sulfuros o metales y se llevan a oxidar entre 600 a 800 °C. Una vez pesada la muestra y los reactivos involucrados durante la fusión, se transfieren al crisol donde ocurrirá la fusión. Se deben mezclar muy bien, de manera manual, la muestra y los reactivos antes de la fusión, además de añadirse un agente liberador (como el yoduro de litio [<xref ref-type="bibr" rid="B94">94</xref>], el bromuro de litio [<xref ref-type="bibr" rid="B95">95</xref>] o el cloruro de litio, que se añade en cantidades menores al 1% en masa) para facilitar la extracción de la perla del molde.</p>
				<p>
					<fig id="f22">
						<label>Figura 22</label>
						<caption>
							<title>Proceso de preparación de una perla fundida.</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf22.png"/>
					</fig>
				</p>
				<p>En matrices como el cemento y la piedra caliza, el CaO de la muestra puede estar presente como CaCO<sub>3</sub>, por lo que se debe llevar a cabo una calcinación de la muestra a 800 °C antes de la fusión, debido a que el aumento repentino de la temperatura puede generar la formación de una espuma (liberación de CO<sub>2</sub>) causada por la reacción química CaCO<sub>3</sub> - → CaO + CO<sub>2</sub>. La calcinación reduce el riesgo de sobreflujo de la muestra y de que quede aire atrapado dentro de las perlas fundidas. Las cenizas obtenidas son utilizadas para la preparación de las perlas fundidas.</p>
				<p>Para llevar a cabo la fusión, la mezcla se funde a altas temperaturas (1000 a 1200 °C) en un crisol de Pt-Au [<xref ref-type="bibr" rid="B96">96</xref>], el cual se mantiene inmóvil hasta que la mezcla se funde. Entre mayor sea la temperatura aplicada, mayor será la fluidez durante la fusión, pero esto puede aumentar la volatilización del fundente y de los analitos, además de disminuir la vida útil del crisol. Si se mantiene fijo el tiempo de fusión, la volatilización del fundente es constante y, por lo tanto, puede ignorarse su efecto. Sin embargo, para minimizar la variación en la volatilización de la muestra debida a diferencias en la composición de la muestra, es aconsejable fusionar a temperaturas más bajas [<xref ref-type="bibr" rid="B97">97</xref>].</p>
				<p>Una vez fundida la muestra, el crisol empieza a sufrir pequeños movimientos para homogeneizar el líquido y eliminar las burbujas de aire. Es importante enfriar la muestra fundida manteniendo sus propiedades vítreas, ya que un enfriamiento rápido puede hacer que la muestra se agriete, mientras que un enfriamiento demasiado lento puede provocar la cristalización. Por ello, se recomienda un enfriamiento lento pasivo al inicio, seguido de un enfriamiento activo [<xref ref-type="bibr" rid="B98">98</xref>]. El tiempo de enfriamiento variará en función de la muestra, el tipo de fundente y la proporción de dilución. La <xref ref-type="fig" rid="f23">figura 23</xref> ilustra el tiempo de enfriamiento de la muestra.</p>
				<p>
					<fig id="f23">
						<label>Figura 23</label>
						<caption>
							<title>Efecto del tiempo de enfriamiento en la calidad de una perla fundida. Elaborado a partir de [<xref ref-type="bibr" rid="B98">98</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf23.png"/>
					</fig>
				</p>
				<p>El producto vítreo se desmolda del crisol después de que se enfría a temperatura ambiente y, posteriormente, se envuelve en papel de parafina y se mantiene en un desecador a temperatura ambiente [<xref ref-type="bibr" rid="B96">96</xref>]. La cantidad de muestra utilizada durante la preparación de una perla fundida depende del tamaño del crisol y del factor de dilución establecido para los analitos que interesa medir. Así mismo, el rendimiento de la fusión depende de la relación muestra-fundente y de la composición de la muestra, por lo que utilizar factores de dilución muy bajos (1:1 o 1:2) o extremadamente altos (1:300) afecta negativamente el rendimiento de la fusión. El efecto matriz (efecto de absorción y realce) puede reducirse considerablemente si se realiza una mayor dilución de las muestras; no obstante, la determinación de elementos menores o trazas se hace más difícil. Diversos estudios han utilizado varias relaciones de dilución según los fines analíticos, por ejemplo, alrededor de 1:10 [<xref ref-type="bibr" rid="B99">99</xref>] de dilución para los óxidos principales, alrededor de 1:5 [<xref ref-type="bibr" rid="B100">100</xref>] de dilución para elementos mayoritarios y minoritarios y alrededor de 1:1 de dilución para los componentes traza. En la <xref ref-type="table" rid="t5">tabla 5</xref> se muestra el efecto del factor de dilución con respecto a la intensidad de los rayos X fluorescentes para líneas de emisión del Si- Kα, Ca- Kα, Ti- Kα y Fe- Kα [<xref ref-type="bibr" rid="B101">101</xref>].</p>
				<p>
					<table-wrap id="t5">
						<label>Tabla 5</label>
						<caption>
							<title>Relación entre la dilución y la intensidad relativa de los rayos X. Tomado de [<xref ref-type="bibr" rid="B101">101</xref>].</title>
						</caption>
						<table>
							<colgroup>
								<col/>
								<col span="3"/>
							</colgroup>
							<thead>
								<tr>
									<th align="center">Factor de dilución</th>
									<th align="center" colspan="3">Intensidad relativa </th>
								</tr>
								<tr>
									<th align="center"> </th>
									<th align="center">Si- Kα</th>
									<th align="center">Ca- Kα</th>
									<th align="center">Ti- Kα</th>
									<th align="center">Fe- Kα</th>
								</tr>
							</thead>
							<tbody>
								<tr>
									<td align="center">1</td>
									<td align="center">62</td>
									<td align="center">78</td>
									<td align="center">91</td>
									<td align="center">92</td>
								</tr>
								<tr>
									<td align="center">2</td>
									<td align="center">45</td>
									<td align="center">64</td>
									<td align="center">83</td>
									<td align="center">85</td>
								</tr>
								<tr>
									<td align="center">5</td>
									<td align="center">24</td>
									<td align="center">42</td>
									<td align="center">67</td>
									<td align="center">70</td>
								</tr>
								<tr>
									<td align="center">10</td>
									<td align="center">14</td>
									<td align="center">27</td>
									<td align="center">50</td>
									<td align="center">54</td>
								</tr>
								<tr>
									<td align="center">20</td>
									<td align="center">7,4</td>
									<td align="center">15</td>
									<td align="center">33</td>
									<td align="center">38</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
			</sec>
			<sec>
				<title><italic>Análisis cuantitativo</italic></title>
				<p>La XRF está sujeta a importantes efectos matriz, que deben tenerse en cuenta cuando se lleve a cabo un análisis cuantitativo. El efecto matriz puede deberse a diferencias físicas en la muestra, lo que ocasiona tanto efectos de absorción como de realce, los cuales afectan la magnitud de la señal del analito [<xref ref-type="bibr" rid="B102">102</xref>]. En la <xref ref-type="fig" rid="f24">figura 24</xref> se muestra un ejemplo del efecto matriz que sufre el Fe en diferentes matrices binarias. Cuando los efectos de la matriz son insignificantes o constantes, se obtiene una relación lineal entre la intensidad de la radiación y la fracción másica del analito (curva A). La curva B se obtiene cuando los elementos de la matriz en la muestra absorben la radiación en mayor proporción que el analito (absorción positiva), por ejemplo, en binarios como FeCr, dónde el Cr absorbe en mayor medida la radiación en comparación con el Fe, por lo que se obtiene un comportamiento similar al de la curva B. La curva C muestra un efecto de aumento en la intensidad del analito, por ejemplo, en el caso de la determinación de Fe en binarios como FeNi, donde la presencia del Ni en la matriz realza la intensidad del Fe. Por último, la curva D muestra cuando el elemento matriz de la muestra absorbe la radiación en menor medida que el analito (absorción negativa), por ejemplo, en binarios como FeMn, donde el Mn no causa un efecto significativo sobre el Fe, por lo que se puede presentar un comportamiento un poco similar al de la curva A [<xref ref-type="bibr" rid="B103">103</xref>].</p>
				<p>
					<fig id="f24">
						<label>Figura 24</label>
						<caption>
							<title>Relación entre la intensidad de la radiación de Fe y la fracción en peso de Fe. Curva A: efecto despreciable, curva B: FeCr, curva C: FeNi y curva D: FeMn. Tomado de [<xref ref-type="bibr" rid="B103">103</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf24.png"/>
					</fig>
				</p>
				<p>En el análisis cuantitativo por XRF, la intensidad de la señal característica va a depender de factores como el tipo de muestra, su preparación, la matriz de la muestra, la rugosidad de la muestra, la superficie irradiada, el flujo, la distribución espectral, la geometría del espectrómetro, entre otros. La interpretación de estas señales se logra utilizando métodos teóricos, los cuales se basan en modelos matemáticos que involucran parámetros físicos como coeficientes de atenuación, probabilidad de transición, procesos de excitación y relajación, etc. [<xref ref-type="bibr" rid="B104">104</xref>]. Los métodos más utilizados en el análisis cuantitativo pueden dividirse en tres categorías: métodos de compensación, métodos de corrección y métodos de reducción de los efectos de matriz <bold>(</bold><xref ref-type="fig" rid="f25">figura 25</xref><bold>).</bold> En los métodos de corrección de matriz, la mayor parte de las variables involucradas durante el proceso de excitación se calculan teóricamente y otras de manera experimental. Con el avance de la tecnología en los últimos años, los métodos teóricos (parámetros fundamentales) y el método de los coeficientes influyentes se han convertido en los más utilizados en el análisis por XRF. Los métodos de reducción de los efectos de matriz buscan la disminución de los efectos de reforzamiento y absorción y esto se logra preparando la muestra con un espesor muy fino (películas delgadas), así, los efectos de matriz se vuelven despreciables [<xref ref-type="bibr" rid="B105">105</xref>].</p>
				<p>
					<fig id="f25">
						<label>Figura 25</label>
						<caption>
							<title>Clasificación general de los métodos aplicados en el análisis cuantitativo por XRF. Elaborado a partir de [<xref ref-type="bibr" rid="B105">105</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf25.png"/>
					</fig>
				</p>
				<p>Los dos métodos más eficaces para corregir los efectos de matriz son los algoritmos de los coeficientes influyentes y el método de los parámetros fundamentales. Dado que las concentraciones de elementos presentes en un espécimen son bastante difíciles de cuantificar con certeza, para los métodos presentados a continuación se puede suponer que las muestras son homogéneas, tienen una superficie plana y pulida y un espesor infinito con respecto a la radiación incidente y a las emisiones del XRF [<xref ref-type="bibr" rid="B106">106</xref>].</p>
			</sec>
			<sec>
				<title><bold>Método <italic>de parámetros</italic> fundamentales</bold></title>
				<p>El método de parámetros fundamentales, empleado para la cuantificación en XRF, es único porque se basa en la relación teórica entre las intensidades de los rayos X y las concentraciones de los elementos en la muestra, sin el uso de estándares [<xref ref-type="bibr" rid="B107">107</xref>]. Esta relación teórica se basa en la física de los rayos X y en los valores de los parámetros atómicos fundamentales de la región de rayos X del espectro electromagnético [<xref ref-type="bibr" rid="B108">108</xref>].</p>
			</sec>
			<sec>
				<title><bold>Algoritmo de los <italic>coeficientes influyentes</italic>
</bold></title>
				<p>El método de los coeficientes influyentes se basa en coeficientes numéricos que corrigen el efecto de cada elemento de la matriz sobre el elemento a determinar (analito) en una muestra dada. Los coeficientes de influencia pueden clasificarse en dos categorías: empíricos y teóricos. En el enfoque multielemental, los coeficientes empíricos se obtienen a partir del análisis de regresión lineal múltiple, utilizando intensidades medidas y composiciones de materiales de referencia multielementales. Por otra parte, los coeficientes empíricos se calculan una vez para un conjunto determinado de materiales de referencia y pueden corregir otros efectos de interferencia como los efectos del tamaño de las partículas, los efectos mineralógicos y los efectos de la rugosidad de la superficie, así como el conocimiento deficiente de la composición de los materiales de referencia y la preparación deficiente de las muestras [<xref ref-type="bibr" rid="B109">109</xref>].</p>
			</sec>
			<sec>
				<title><italic>Validación del método</italic></title>
				<p>La validación es importante para garantizar la fiabilidad de un método analítico, incluida la preparación de la muestra y el método de cuantificación [<xref ref-type="bibr" rid="B110">110</xref>]. La validación busca garantizar que un método analítico genera resultados confiables bajo las condiciones de trabajo del laboratorio. El Vocabulario Internacional de Metrología (VIM) define la validación como una &quot;verificación, donde los requisitos especificados son adecuados para un uso previsto&quot;, entendiendo que la verificación es el proceso de presentar de manera objetiva la evidencia de que se cumplen unos requisitos específicos [<xref ref-type="bibr" rid="B111">111</xref>]. En los análisis por XRF, los parámetros de validación que más reportan los autores en sus estudios son el límite de detección (LOD), el límite de cuantificación (LOQ) y la exactitud, aunque no se puede dejar de lado que existen otros parámetros importantes como linealidad, selectividad y robustez. A continuación, se describen estos parámetros teniendo en cuenta su definición en el VIM, la Eurachem y la ISO 3534, esto con el fin de aclarar algunos conceptos inequívocos que se utilizan en lo referente a estos parámetros. De igual manera, se describe la forma de evaluarlos y se presentan ejemplos aplicados en XRF por algunos autores.</p>
			</sec>
			<sec>
				<title><bold>Límite de <italic>detección (LOD) y límite de cuantificación (LOQ)</italic>
</bold></title>
				<p>El VIM define el LOD como &quot;el valor medido, obtenido mediante un procedimiento de medición dado, con una probabilidad β de declarar erróneamente la ausencia de un constituyente en un material, dada una probabilidad α de declarar erróneamente su presencia&quot; [<xref ref-type="bibr" rid="B111">111</xref>]. De esta definición se destaca que se hace referencia a un valor medido y, para evaluar los límites de detección, se debe realizar su confirmación mediante mediciones y no solo estimarlo.</p>
				<p>En los espectrómetros de XRF, el LOD puede alcanzar valores de aproximadamente 0,2 mg/kg; no obstante, este va a depender de varios factores como, por ejemplo, la preparación de la muestra, el tiempo de medición, la matriz de la muestra y la presencia de elementos de interferencia [<xref ref-type="bibr" rid="B112">112</xref>]. En la Ec. (1) se muestra una manera de calcular el LOD del elemento de interés:</p>
				<p>
					<disp-formula id="e1">
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-e1.png"/>
					</disp-formula>
				</p>
				<p>dónde LOD es el límite de detección del elemento objetivo, m es la pendiente de la curva de calibración y σ es la desviación estándar de mediciones para una muestra (N-1) [<xref ref-type="bibr" rid="B113">113</xref>].</p>
				<p>Por otro lado, el LOQ se define como la cantidad mínima de analito que puede ser cuantificada con un desempeño aceptable [<xref ref-type="bibr" rid="B114">114</xref>]. La estimación del LOQ de manera experimental se lleva a cabo de acuerdo con la mayoría de las convenciones: la desviación estándar obtenida (σ) a niveles bajos multiplicada por un factor kQ que puede ser igual a diez. También es posible calcular el LOQ con cualquiera de los métodos empleados para el cálculo del límite de detección, pero en lugar de multiplicar por tres se debe multiplicar por el factor kQ mencionado anteriormente, como muestra la Ec. (2):</p>
				<p>
					<disp-formula id="e2">
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-e2.png"/>
					</disp-formula>
				</p>
				<p>donde, al igual que en la Ec. (1), m es la pendiente de la curva de calibración y σ es la desviación estándar de mediciones para una muestra.</p>
				<p>Por último, de acuerdo con la guía para la validación de métodos en análisis químico cuantitativo, publicada por el INM, es válido tomar el límite inferior del intervalo de trabajo como el límite de cuantificación [<xref ref-type="bibr" rid="B115">115</xref>].</p>
				<p>En la <xref ref-type="table" rid="t6">tabla 6</xref> se muestran valores del LOD calculados para un método de medición de leche en polvo por WDXRF, los cuales fueron calculados por Fernandes et al. [<xref ref-type="bibr" rid="B116">116</xref>] utilizando las Ec. (1) y (2). De los datos reportados por los autores, se tiene que los límites de detección de los metales incluidos en este estudio estaban en el intervalo de 0,2 a 1,8 mg/kg, excepto para el Al, para el que se estimó un LOD de 7,0 mg/kg. Los resultados del límite de cuantificación variaron considerablemente desde Cu, donde el LOQ se estimó desde 0,6 hasta 21,2 mg/kg.</p>
				<p>
					<table-wrap id="t6">
						<label>Tabla 6</label>
						<caption>
							<title>Valores de los límites de detección y cuantificación obtenidos durante la validación del método de WDXRF para análisis de leche en polvo. Tomado de [<xref ref-type="bibr" rid="B116">116</xref>].</title>
						</caption>
						<table>
							<colgroup>
								<col/>
								<col/>
								<col/>
							</colgroup>
							<thead>
								<tr>
									<th align="center">Elemento</th>
									<th align="center">LOD (mg/kg)</th>
									<th align="center">LOQ (mg/kg)</th>
								</tr>
							</thead>
							<tbody>
								<tr>
									<td align="center">Al</td>
									<td align="center">7,0</td>
									<td align="center">21,2</td>
								</tr>
								<tr>
									<td align="center">Cu</td>
									<td align="center">0,8</td>
									<td align="center">2,4</td>
								</tr>
								<tr>
									<td align="center">Fe</td>
									<td align="center">1,8</td>
									<td align="center">5,5</td>
								</tr>
								<tr>
									<td align="center">Zn</td>
									<td align="center">0,2</td>
									<td align="center">0,6</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
				<sec>
					<title><bold>Exactitud: <italic>veracidad y precisión</italic>
</bold></title>
					<p>El VIM define la exactitud &quot;como la proximidad entre un valor medido y un valor verdadero de un mensurando&quot; [<xref ref-type="bibr" rid="B111">111</xref>]. Sin embargo, conocer el valor verdadero del mensurando en la práctica no es posible. De igual manera, la ISO 3534 define la exactitud &quot;como la proximidad de concordancia entre el resultado de una medición y el valor de referencia aceptado&quot; [<xref ref-type="bibr" rid="B117">117</xref>]. Cuando este término se aplica a resultados de medición, se involucra la combinación de errores aleatorios y errores sistemáticos o sesgo. De acuerdo con lo anterior, para evaluar la exactitud se estiman los errores sistemáticos y aleatorios de los resultados en varias mediciones, los cuales están representados por los parámetros de veracidad y precisión, respectivamente. En la <xref ref-type="fig" rid="f26">figura 26</xref> se presenta un esquema que muestra la relación que existe entre la exactitud, los tipos de errores y los parámetros del método [<xref ref-type="bibr" rid="B118">118</xref>].</p>
					<p>
						<fig id="f26">
							<label>Figura 26</label>
							<caption>
								<title>Determinación de la exactitud de un método de medición. Tomado de [<xref ref-type="bibr" rid="B118">118</xref>].</title>
							</caption>
							<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf26.png"/>
						</fig>
					</p>
					<p>Para realizar la validación de estos parámetros (precisión y veracidad) en XRF, es importante tener clara la definición de cada uno. Para hablar de precisión, el VIM la define como &quot;la proximidad entre las indicaciones o los valores medidos obtenidos en mediciones repetidas de un mismo objeto, o de objetos similares, bajo condiciones específicas&quot; [<xref ref-type="bibr" rid="B111">111</xref>]. Por lo tanto, se deben tener en cuenta una serie de criterios para la validación de la precisión, tales como [<xref ref-type="bibr" rid="B115">115</xref>]:</p>
					<p>
						<list list-type="bullet">
							<list-item>
								<p>Realizar un mínimo de diez réplicas instrumentales.</p>
							</list-item>
							<list-item>
								<p>Expresarla como una medida de dispersión (desviación estándar o desviación estándar relativa).</p>
							</list-item>
							<list-item>
								<p>Evaluarla bajo condiciones específicas como repetibilidad y re-producibilidad.</p>
							</list-item>
						</list>
					</p>
					<p>La precisión, en condiciones de repetibilidad, busca determinar la dispersión del método manteniendo condiciones repetibles de medición: muestras idénticas y homogéneas, mismo laboratorio, mismo analista y mismo equipo en intervalos de tiempo cortos. La precisión como reproducibilidad se entiende como la máxima dispersión del método en condiciones en las que los resultados de medición se obtienen de muestras idénticas, pero que se realizan en diferentes laboratorios, con diferente analista, diferentes equipos y durante un intervalo de tiempo en el que se pueden presentar diferencias entre los materiales y equipos, ocasionando la máxima dispersión de un mismo proceso analítico. La precisión como reproducibilidad es bastante costosa y, por tiempos, no tan fácil de llevar a cabo, por lo que suele validarse en condiciones de precisión intermedia.</p>
					<p>La precisión intermedia evalúa la dispersión de los resultados de mediciones independientes que utilizan el mismo método y la misma muestra en el mismo laboratorio, pero que se llevan a cabo por distintos analistas, diferentes equipos o en diferentes días.</p>
					<p>En la <xref ref-type="table" rid="t7">tabla 7</xref> se muestran los resultados relacionados con el parámetro de precisión como repetibilidad y como precisión intermedia, los cuales fueron evaluados por Mijatović et al. en su estudio de medición de arcillas por XRF. La precisión fue evaluada teniendo en cuenta tres preparaciones de muestra diferentes: polvos prensados sin aglutinante (PPB), polvos prensados calcinados (FPP) y polvos sueltos (LP) y fue expresada como la RSD de tres replicas instrumentales. La repetibilidad se estimó en las mismas condiciones, midiendo las mismas muestras de MRC para las tres preparaciones, el mismo día y por triplicado; la precisión intermedia fue evaluada midiendo muestras de MRC en condiciones diferentes, con dos analistas y en diferentes días [<xref ref-type="bibr" rid="B89">89</xref>]. Los autores concluyen que la precisión de las muestras de arcilla, calcinadas y preparadas como FPP, fue mejor para los elementos ligeros, debido a la mayor homogeneización de la muestra en comparación con las otras preparaciones (LP y PPB). Esta conclusión podría estar relacionada con las ventajas destacadas de la preparación de FPP como método de preparación de muestras de arcilla para mediciones por EDXRF.</p>
					<p>
						<table-wrap id="t7">
							<label>Tabla 7</label>
							<caption>
								<title>Repetibilidad y precisión intermedia del método de XRF para evaluar tres métodos de preparación de arcilla. Tomado de [<xref ref-type="bibr" rid="B89">89</xref>].</title>
							</caption>
							<table>
								<colgroup>
									<col/>
									<col span="3"/>
									<col span="3"/>
								</colgroup>
								<thead>
									<tr>
										<th align="center">Elemento</th>
										<th align="center" colspan="3">Repetibilidad (% RSD) </th>
										<th align="center" colspan="3">Precisión intermedia (% RSD) </th>
									</tr>
									<tr>
										<th align="center"> </th>
										<th align="center">LP</th>
										<th align="center">PPB</th>
										<th align="center">FPP</th>
										<th align="center">LP</th>
										<th align="center">PPB</th>
										<th align="center">FPP</th>
									</tr>
								</thead>
								<tbody>
									<tr>
										<td align="center">Si</td>
										<td align="center">1,85</td>
										<td align="center">1,57</td>
										<td align="center">0,41</td>
										<td align="center">2,35</td>
										<td align="center">2,15</td>
										<td align="center">0,75</td>
									</tr>
									<tr>
										<td align="center">Al</td>
										<td align="center">1,52</td>
										<td align="center">1,96</td>
										<td align="center">1,14</td>
										<td align="center">1,71</td>
										<td align="center">2,10</td>
										<td align="center">2,60</td>
									</tr>
									<tr>
										<td align="center">Fe</td>
										<td align="center">1,22</td>
										<td align="center">0,88</td>
										<td align="center">0,84</td>
										<td align="center">1,32</td>
										<td align="center">2,00</td>
										<td align="center">1,34</td>
									</tr>
									<tr>
										<td align="center">Mg</td>
										<td align="center">2,81</td>
										<td align="center">1,23</td>
										<td align="center">1,27</td>
										<td align="center">3,64</td>
										<td align="center">3,82</td>
										<td align="center">3,53</td>
									</tr>
									<tr>
										<td align="center">Ca</td>
										<td align="center">0,72</td>
										<td align="center">0,23</td>
										<td align="center">0,21</td>
										<td align="center">0,86</td>
										<td align="center">0,71</td>
										<td align="center">0,53</td>
									</tr>
									<tr>
										<td align="center">Na</td>
										<td align="center">1,48</td>
										<td align="center">1,25</td>
										<td align="center">1,37</td>
										<td align="center">1,78</td>
										<td align="center">1,26</td>
										<td align="center">2,04</td>
									</tr>
									<tr>
										<td align="center">K</td>
										<td align="center">0,27</td>
										<td align="center">0,30</td>
										<td align="center">0,31</td>
										<td align="center">0,85</td>
										<td align="center">0,42</td>
										<td align="center">0,36</td>
									</tr>
									<tr>
										<td align="center">Ti</td>
										<td align="center">0,47</td>
										<td align="center">0,43</td>
										<td align="center">0,11</td>
										<td align="center">0,72</td>
										<td align="center">0,49</td>
										<td align="center">0,25</td>
									</tr>
									<tr>
										<td align="center">P</td>
										<td align="center">2,09</td>
										<td align="center">0,64</td>
										<td align="center">1,43</td>
										<td align="center">4,11</td>
										<td align="center">1,89</td>
										<td align="center">2,25</td>
									</tr>
									<tr>
										<td align="center">Mn</td>
										<td align="center">0,63</td>
										<td align="center">0,23</td>
										<td align="center">0,72</td>
										<td align="center">1,26</td>
										<td align="center">0,46</td>
										<td align="center">0,79</td>
									</tr>
									<tr>
										<td align="center">S</td>
										<td align="center">2,01</td>
										<td align="center">2,16</td>
										<td align="center">1,96</td>
										<td align="center">2,61</td>
										<td align="center">4,56</td>
										<td align="center">2,70</td>
									</tr>
								</tbody>
							</table>
							<table-wrap-foot>
								<fn id="TFN9">
									<p>PPB: polvos prensados sin aglutinante.</p>
								</fn>
								<fn id="TFN10">
									<p>FPP: polvos prensados calcinados.</p>
								</fn>
								<fn id="TFN11">
									<p>LP: polvos sueltos.</p>
								</fn>
							</table-wrap-foot>
						</table-wrap>
					</p>
					<p>En otro estudio, Margui <italic>et al.</italic> [<xref ref-type="bibr" rid="B119">119</xref>] evaluaron la precisión intermedia del método de WDXRF para la medición de muestras vegetales; para ello, midieron una muestra tres veces durante un período de un mes. Los resultados que se reportan en el trabajo muestran que la RSD fue inferior al 6%, excepto para el Na, el Al y el P, que presentaron un valor de RSD que oscila entre el 9 y el 20%. Los autores atribuyen este hecho a la posible deformación de la superficie plana del polvo prensado, por lo que se sugiere que el tiempo entre el prensado de la muestra y el análisis sea lo más corto posible para evitar cambios en la superficie del polvo prensado, los cuales podrían alterar la intensidad medida de algunos elementos y, por lo tanto, la concentración de analitos.</p>
					<p>Por otra parte, el parámetro veracidad es definido por el VIM &quot;como la proximidad entre la media de un número infinito de valores medidos repetidos y un valor de referencia&quot; [<xref ref-type="bibr" rid="B111">111</xref>]. Esta definición indica que experimentalmente no es posible estimar este parámetro, pues no se pueden llevar a cabo un número infinito de mediciones, por lo que la veracidad se expresa en términos de sesgo y porcentaje de recuperación. La veracidad como sesgo se define como la diferencia entre el valor esperado de los valores medidos y un valor de referencia:</p>
					<p>
						<disp-formula id="e3">
							<graphic xlink:href="2357-3791-rcq-52-03-e111499-e3.png"/>
						</disp-formula>
					</p>
					<p>donde <inline-graphic xlink:href="2357-3791-rcq-52-03-e111499-i032.png"/> es el promedio de las n mediciones realizadas y <italic>Xr</italic> corresponde a un valor de referencia aceptado, que puede ser establecido al realizar las mediciones con un método de referencia o puede ser dado por los valores certificados de un MRC.</p>
					<p>La veracidad como recuperación corresponde a la concentración medida del analito y la concentración conocida o añadida a la muestra, expresadas en términos de porcentaje; es decir, la recuperación estima el error sistemático y, de manera similar al sesgo, puede dar valores positivos (superiores al 100%) y valores negativos (inferiores al 100%) [<xref ref-type="bibr" rid="B115">115</xref>].</p>
					<p>Experimentalmente, para evaluar la veracidad como recuperación, a una muestra considerada como blando de muestra (sin presencia de analito) se le adiciona una cantidad de analito en concentración conocida y, posteriormente, esta muestra fortificada es analizada utilizando el método de medición que se está validando o evaluando. La estimación del porcentaje de recuperación se realiza mediante la Ec. (4):</p>
					<p>
						<disp-formula id="e4">
							<graphic xlink:href="2357-3791-rcq-52-03-e111499-e4.jpg"/>
						</disp-formula>
					</p>
					<p>En algunos casos no es posible obtener un blanco de muestra, por lo que se puede realizar el experimento de recuperación midiendo una muestra que puede contener el analito, pero idealmente en concentraciones inferiores al límite inferior del intervalo de trabajo. En este caso, una alícuota de la muestra sin fortificar y una alícuota de la muestra fortificada son medidas para estimar posteriormente el porcentaje de recuperación usando la Ec. (5):</p>
					<p>
						<disp-formula id="e5">
							<graphic xlink:href="2357-3791-rcq-52-03-e111499-e5.jpg"/>
						</disp-formula>
					</p>
					<p>Autores como Kulal et al. utilizaron tres MRC, 1573a <italic>(tomato</italic> leaves), 1570a (spinach leaves) y CTA OTL 1 <italic>(tobacco</italic> leaves), para la validación del parámetro de veracidad como sesgo. En la <xref ref-type="table" rid="t8">tabla 8 </xref>se muestran los resultados que los autores obtuvieron durante la validación, los menores porcentajes de sesgo se obtuvieron con las mediciones realizadas al MRC de <italic>tobacco leaves</italic> [<xref ref-type="bibr" rid="B68">68</xref>].</p>
					<p>
						<table-wrap id="t8">
							<label>Tabla 8</label>
							<caption>
								<title>Resultados de la evaluación de la veracidad como sesgo de un método de WDXRF para el análisis de plantas medicinales. Tomado de [<xref ref-type="bibr" rid="B68">68</xref>].</title>
							</caption>
							<table>
								<colgroup>
									<col/>
									<col span="3"/>
									<col span="3"/>
									<col span="3"/>
								</colgroup>
								<thead>
									<tr>
										<th align="center">Elemento</th>
										<th align="center" colspan="3"><bold>1573a <italic>(tomato leaves)</italic>
</bold></th>
										<th align="center" colspan="3"><bold>1570a <italic>(spinach leaves)</italic>
</bold></th>
										<th align="center" colspan="3"><bold>CTA OTL 1 <italic>(tobacco leaves)</italic>
</bold></th>
									</tr>
									<tr>
										<th align="center"> </th>
										<th align="center">Valor MRC (mg/kg)</th>
										<th align="center">Valor XRF (mg/kg)</th>
										<th align="center">Sesgo (%)</th>
										<th align="center">Valor MRC (mg/kg)</th>
										<th align="center">Valor XRF (mg/kg)</th>
										<th align="center">Sesgo (%)</th>
										<th align="center">Valor MRC (mg/kg)</th>
										<th align="center">Valor XRF (mg/kg)</th>
										<th align="center">Sesgo (%)</th>
									</tr>
								</thead>
								<tbody>
									<tr>
										<td align="center">Fe</td>
										<td align="center">368</td>
										<td align="center">3302,08</td>
										<td align="center">17,91</td>
										<td align="center">455</td>
										<td align="center">376,82</td>
										<td align="center">17,18</td>
										<td align="center">989</td>
										<td align="center">1033,4</td>
										<td align="center">4,4</td>
									</tr>
									<tr>
										<td align="center">Cr</td>
										<td align="center">1,99</td>
										<td align="center">2,21</td>
										<td align="center">10,85</td>
										<td align="center">NA</td>
										<td align="center">1,77</td>
										<td align="center">NA</td>
										<td align="center">2,59</td>
										<td align="center">2,39</td>
										<td align="center">7,75</td>
									</tr>
									<tr>
										<td align="center">Mn</td>
										<td align="center">246</td>
										<td align="center">215,45</td>
										<td align="center">12,42</td>
										<td align="center">76</td>
										<td align="center">81,49</td>
										<td align="center">7,22</td>
										<td align="center">412</td>
										<td align="center">426,3</td>
										<td align="center">3,48</td>
									</tr>
									<tr>
										<td align="center">Co</td>
										<td align="center">0,57</td>
										<td align="center">0,42</td>
										<td align="center">25,60</td>
										<td align="center">0,39</td>
										<td align="center">0,36</td>
										<td align="center">8,42</td>
										<td align="center">0,87</td>
										<td align="center">0,96</td>
										<td align="center">8,78</td>
									</tr>
									<tr>
										<td align="center">Ni</td>
										<td align="center">1,59</td>
										<td align="center">2,08</td>
										<td align="center">30,95</td>
										<td align="center">2,14</td>
										<td align="center">1,66</td>
										<td align="center">22,5</td>
										<td align="center">6,32</td>
										<td align="center">6,28</td>
										<td align="center">0,59</td>
									</tr>
									<tr>
										<td align="center">Cu</td>
										<td align="center">4,7</td>
										<td align="center">5,17</td>
										<td align="center">9,96</td>
										<td align="center">12,22</td>
										<td align="center">11,3</td>
										<td align="center">7,5</td>
										<td align="center">14,1</td>
										<td align="center">14,55</td>
										<td align="center">3,18</td>
									</tr>
									<tr>
										<td align="center">Zn</td>
										<td align="center">30,9</td>
										<td align="center">28,67</td>
										<td align="center">7,2</td>
										<td align="center">82,3</td>
										<td align="center">82,51</td>
										<td align="center">0,26</td>
										<td align="center">49,9</td>
										<td align="center">50,74</td>
										<td align="center">1,69</td>
									</tr>
									<tr>
										<td align="center">As</td>
										<td align="center">0,112</td>
										<td align="center">0,11</td>
										<td align="center">2,65</td>
										<td align="center">0,06</td>
										<td align="center">0,07</td>
										<td align="center">4,61</td>
										<td align="center">0,53</td>
										<td align="center">0,54</td>
										<td align="center">0,03</td>
									</tr>
									<tr>
										<td align="center">Pb</td>
										<td align="center">NA</td>
										<td align="center">1,02</td>
										<td align="center">NA</td>
										<td align="center">0,2</td>
										<td align="center">0,29</td>
										<td align="center">4,47</td>
										<td align="center">4,91</td>
										<td align="center">4,89</td>
										<td align="center">0,49</td>
									</tr>
								</tbody>
							</table>
						</table-wrap>
					</p>
				</sec>
			</sec>
			<sec>
				<title><italic>Método de referencia</italic></title>
				<p>La validación requiere que el MRC o MR y la muestra objetivo tengan matrices similares, pero esto no siempre es posible, ya que puede que no exista un MRC adecuado o de matriz similar a la muestra. Es posible desarrollar nuevos MR como puntos (niveles) para la construcción de una curva de calibración, pero estos estándares de calibración preparados deben analizarse con otro método de medición (por ejemplo, AA, ICP-MS, ICP-OES, LIBS, etc.) para hacer una comparación cruzada de los resultados por los dos métodos. Autores como Perring y Blanc [<xref ref-type="bibr" rid="B120">120</xref>] desarrollaron y validaron un método rápido y eficaz para la determinación de hierro en cereales infantiles de marcas comerciales mediante EDXRF. Para la validación, ellos utilizaron un conjunto de veinte muestras, las cuales fueron medidas por el método que desarrollaron y compararon los resultados con los obtenidos por el método de referencia, el cual fue la ICP-OES (también conocida como espectroscopia de emisión atómica de plasma acoplado inductivamente o ICP-AES). Durante la validación, para el parámetro de repetibilidad midieron tres muestras con tres réplicas instrumentales, y obtuvieron un valor de 134,1 mg/ kg de Fe, tanto para las mediciones por el método de EDXRF como por ICP-AES. En la <xref ref-type="fig" rid="f27">figura 27</xref> se correlacionan los valores de concentración de Fe (mg/kg) obtenidos por los dos métodos, los autores concluyeron que no se presentaron diferencias significativas entre ambos.</p>
				<p>
					<fig id="f27">
						<label>Figura 27</label>
						<caption>
							<title>Valores de concentración de Fe (mg/kg) por EDXRF vs concentración de Fe (mg/kg) por ICP-AES. Tomado de [<xref ref-type="bibr" rid="B120">120</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf27.png"/>
					</fig>
				</p>
				<p>Algunos investigadores utilizan métodos de referencia, aunque cuenten con MRC para llevar a cabo la validación del método. Tal es el caso de Oliveira <italic>et al.</italic> [<xref ref-type="bibr" rid="B121">121</xref>], quienes desarrollaron un método para análisis elemental en muestras de cocoa y chocolate en polvo usando la EDXRF. Para validar los parámetros de precisión y exactitud, utilizaron el MRC 2384 (baking chocolate) del NIST, también compararon los resultados con el método de referencia ICP-OES y concluyeron que no había diferencias significativas entre las concentraciones obtenidas por medio de los dos métodos. En la <xref ref-type="fig" rid="f28">figura 28</xref> se muestra la correlación entre los dos métodos comparados en este estudio, donde se obtuvo un R<sup>2</sup> &gt; 0,99.</p>
				<p>
					<fig id="f28">
						<label>Figura 28</label>
						<caption>
							<title>Valores de concentración de K (mg/kg) por EDXRF vs concentración de K (mg/kg) por ICP-OES. Tomado de [<xref ref-type="bibr" rid="B121">121</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gf28.png"/>
					</fig>
				</p>
			</sec>
			<sec>
				<title>Aplicaciones recientes de la XRF</title>
				<p>El uso de la espectrometría de XRF en aplicaciones industriales se ha incrementado debido a la flexibilidad de la técnica en los análisis cualitativos y cuantitativos, tanto a nivel de laboratorio como in situ. Los últimos avances en el análisis por XRF se han logrado gracias al desarrollo de nuevas ópticas y detectores de rayos X. Por ejemplo, en la investigación realizada por Tsuji et al., se utilizó la microfluorescencia de rayos X (μ-XRF) con focal para visualizar la distribución elemental de Au-Lα, Ni-Kα, Ti-Kα, Cu-Kα y Br-Kα mientras se realizaban mediciones directas a una tarjeta de memoria microSD y, de manera paralela, los autores propusieron la modificación de un espectrómetro de dispersión por longitud de onda para la obtención rápida de imágenes XRF elementales, utilizando un nuevo detector de rayos X bidimensional, el detector Pilatus [<xref ref-type="bibr" rid="B122">122</xref>].</p>
				<p>Las mediciones <italic>in situ</italic> se han vuelto cada vez más relevantes, por lo tanto, los equipos de XRF portátiles se han convertido en una poderosa herramienta para los análisis en campo. Tal es el caso de las mediciones realizadas por Turner y Filella [<xref ref-type="bibr" rid="B123">123</xref>] para la cuantificación de antimonio (Sb), utilizando XRF con energía dispersiva portátil (p-XRF), en una serie de productos poliméricos de uso frecuente, como aparatos electrónicos (televisores, neveras y computadores), juguetes, bombillas, tapicería, ropa de tela sintética, gafas de sol, productos de PET, entre otros; de este estudio los autores concluyen que hay presencia de Sb catalítico en los envases de alimentos y en los juguetes para niños, lo cual es un tema preocupante por su riesgo para la salud, lo que requiere seguir investigando la toxicidad del Sb y su migración en matrices poliméricas, así como reconsiderar los medios de eliminación y reciclaje de los residuos plásticos y electrónicos con contenido de Sb.</p>
				<p>En la industria alimentaria, la XRF se sigue utilizando como una técnica que permite el análisis cuantitativo de elementos mayoritarios y trazas. En el estudio realizado por Vivek et al. [<xref ref-type="bibr" rid="B124">124</xref>], utilizaron la WDXRF para el estudio de enfermedades agrícolas en plantas y granos de arroz, midiendo los cambios elementales causados por la presencia de nematodos y falso tizón. Utilizaron un método de referencia llamado espectroscopia de descomposición inducida por láser (LIBS) y concluyeron que los resultados obtenidos por las dos técnicas son similares; además, evidenciaron que hay cambios significativos en las concentraciones elementales (elementos mayores, traza y metales pesados) debido a la presencia de la enfermedad, tal como se muestra en la <xref ref-type="table" rid="t9">tabla 9</xref><bold>.</bold></p>
				<p>
					<table-wrap id="t9">
						<label>Tabla 9</label>
						<caption>
							<title>Resumen de las especies de plantas, enfermedades y elementos detectados en muestras de plantas sanas y enfermas. Tomado de [<xref ref-type="bibr" rid="B124">124</xref>].</title>
						</caption>
						<graphic xlink:href="2357-3791-rcq-52-03-e111499-gt9.png"/>
						<table-wrap-foot>
							<fn id="TFN12">
								<p>A: elementos detectados en plantas mediante WDXRF.</p>
							</fn>
							<fn id="TFN13">
								<p>B: elementos con aumento de la concentración en muestras de plantas enfermas.</p>
							</fn>
							<fn id="TFN14">
								<p>C: elementos con disminución de la concentración en muestras de plantas enfermas.</p>
							</fn>
							<fn id="TFN15">
								<p>D: elementos detectados sólo en plantas enfermas.</p>
							</fn>
						</table-wrap-foot>
					</table-wrap>
				</p>
				<p>La determinación de impurezas en las materias primas destinadas a la fabricación de productos farmacéuticos es importante para garantizar la calidad del producto final, así como para evitar daños a la salud. Las impurezas metálicas pueden presentar efectos tóxicos incluso a bajas concentraciones, por lo que las agencias reguladoras y las farmacopeas definen los niveles permisibles. En este sentido, técnicas rápidas, sensibles y precisas, como la técnica de XRF, son una alternativa para el análisis de metales en materiales de uso farmacéutico.</p>
				<p>Paulino <italic>et al.</italic> [<xref ref-type="bibr" rid="B125">125</xref>] vieron la necesidad de investigar la presencia de contaminantes y sus niveles de concentración en productos farmacéuticos, su trabajo se centró en validar un método para utilizar la técnica EDXRF para identificar y cuantificar la composición química de materias primas y productos farmacéuticos. Las muestras se homogeneizaron utilizando un mortero de ágata y un mezclador rotativo que contenía bolas de acero en su interior y, posteriormente, la mezcla se separó en porciones de 4 g y se compactó cada sub-muestra a una presión de 10 t durante 30 s. Una vez preparadas las muestras, se procede con la validación del método, dónde los parámetros validados fueron la selectividad, la linealidad, la precisión, LOD, LOQ y la robustez. Los resultados de la validación demostraron que la EDXRF puede ser utilizada como técnica de detección y cuantificación de impurezas elementales pertenecientes a la clase 1 (Cd, Pb, As, Hg) y a la clase 2A (Co, V, Ni).</p>
				<p>Otro estudio realizado en el campo farmacéutico fue el realizado por Cruz et al. [<xref ref-type="bibr" rid="B126">126</xref>], donde utilizaron la TXRF para el análisis cuantitativo de metales tóxicos (Pb, As, Cr y Hg) en muestras de suplementos dietarios. Se realizó la validación del método, evaluando los parámetros de linealidad, repetibilidad, reproducibilidad, LOD y LOQ. Los valores obtenidos para el LOD fueron 0,59; 0,41; 0,57 y 0,75 μg/L y para el LOQ fueron 1,95; 1,35; 1,9 y 2,5 μg/L para Pb, As, Cr y Hg, respectivamente. Los autores concluyeron que los resultados que obtuvieron fueron satisfactorios, según lo recomendado por la IUPAC y la Administración de Alimentos y Medicamentos (FDA) de los EE. UU.</p>
				<p>Por último, la investigación en materiales inorgánicos se encuentra actualmente en fase de crecimiento (en particular, en el campo de los nanomateriales) y la XRF está desempeñando un papel importante en la caracterización de dichos materiales. El estudio de los procesos de deposición de nanopartículas sobre muestras de superficie plana y lisa, el tamaño medio de las nanopartículas y su forma, fueron realizado por Tiwari [<xref ref-type="bibr" rid="B127">127</xref>] utilizando un espectrómetro de XRF de incidencia rasante (GIXRF), que es una versión mejorada de la TXRF. El empleo de esta técnica permitió determinar el tamaño medio de las nanopartículas tras realizar una única medición, por lo que se concluye que es una técnica que puede emplearse con éxito para analizar la morfología superficial de materiales nanoestructurados, que estén dispersos sobre una superficie pulida o incrustados en el interior de la matriz de análisis.</p>
			</sec>
		</sec>
		<sec sec-type="conclusions">
			<title>Conclusiones</title>
			<p>Este artículo de revisión dio a conocer las generalidades de la técnica de XRF, los diferentes tipos de espectrómetros, las ventajas y el alcance de estos. Así mismo, se logró evidenciar que la técnica de XRF es ampliamente utilizada para el análisis elemental de muestras sólidas y en polvo debido a ventajas tales como su versatilidad, su carácter no destructivo y sus buenos niveles de precisión.</p>
			<p>Es importante mencionar que, para el análisis de matrices orgánicas, se presentan grandes retos durante la medición como, por ejemplo, el efecto matriz, por lo que, en las mediciones por XRF, se hace indispensable lograr una muy buena preparación de las muestras sólidas, esto incluye el pretratamiento al que se debe someter la muestra, tanto para la obtención de muestras en polvo que se puedan medir directamente en el equipo de XRF o para preparar polvos prensados o perlas fundidas; y la elección correcta del método de preparación de la muestra, que dependerá de las características de la misma, de los analitos de interés y del método de medición. Es indispensable realizar la validación del método analítico (la cual incluye la preparación y la determinación de la cantidad mínima de muestra), haciendo uso de MR y MRC, con el fin de garantizar que los métodos de medición cumplan con los criterios establecidos para su uso previsto (sesgo, precisión, selectividad, exactitud, etc.) y se pueda asegurar la validez de los resultados.</p>
			<p>Finalmente, toda la información recopilada en este artículo puede ser utilizada por diversos investigadores como base para el desarrollo de sus diferentes proyectos donde se requiera hacer uso de la técnica de XRF.</p>
			<p>
				<table-wrap id="t10">
					<graphic xlink:href="2357-3791-rcq-52-03-e111499-gt10.jpg"/>
				</table-wrap>
			</p>
		</sec>
	</body>
	<back>
		<ref-list>
			<title>Referencias</title>
			<ref id="B1">
				<label>[1]</label>
				<mixed-citation>[1] Maria D, Posso L. Validacion del método de determinación de calcio y magnesio por espectroscopia de absorción atómica de llama para el laboratorio de análisis de Aguas y alimentos de la Universidad Tecnológica de Pereira. tesis de grado. Universidad Tecnológica de Pereira. Pereira. 2013. <ext-link ext-link-type="uri" xlink:href="https://repositorio.utp.edu.co/server/api/core/bitstreams/a9fcd46b-3fad-4d84-b627-fa4942db5f3c/content">https://repositorio.utp.edu.co/server/api/core/bitstreams/a9fcd46b-3fad-4d84-b627-fa4942db5f3c/content</ext-link>
				</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>Maria</surname>
							<given-names>D</given-names>
						</name>
						<name>
							<surname>Posso</surname>
							<given-names>L</given-names>
						</name>
					</person-group>
					<source>Validacion del método de determinación de calcio y magnesio por espectroscopia de absorción atómica de llama para el laboratorio de análisis de Aguas y alimentos de la Universidad Tecnológica de Pereira</source>
					<comment content-type="degree">tesis de grado</comment>
					<publisher-name>Universidad Tecnológica de Pereira</publisher-name>
					<publisher-loc>Pereira</publisher-loc>
					<year>2013</year>
					<ext-link ext-link-type="uri" xlink:href="https://repositorio.utp.edu.co/server/api/core/bitstreams/a9fcd46b-3fad-4d84-b627-fa4942db5f3c/content">https://repositorio.utp.edu.co/server/api/core/bitstreams/a9fcd46b-3fad-4d84-b627-fa4942db5f3c/content</ext-link>
				</element-citation>
			</ref>
			<ref id="B2">
				<label>[2]</label>
				<mixed-citation>[2] Thomas R. A Beginner's Guide to ICP-MS. Part VII: Mass Separation Devices-Double Focusing Magnetic-Sector Technology. Spectroscopy Tutorial. 2001;161122-27.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Thomas</surname>
							<given-names>R</given-names>
						</name>
					</person-group>
					<article-title>A Beginner's Guide to ICP-MS. Part VII: Mass Separation Devices-Double Focusing Magnetic-Sector Technology</article-title>
					<source>Spectroscopy Tutorial</source>
					<year>2001</year>
					<volume>16</volume>
					<issue>11</issue>
					<fpage>22</fpage>
					<lpage>27</lpage>
				</element-citation>
			</ref>
			<ref id="B3">
				<label>[3]</label>
				<mixed-citation>[3] Jiménez M, Grijalva A, Ponce H. Plasma acoplado inductivamente en espectroscopia de emisión óptica (ICP-OES). Recimundo. 2020;444-12. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.26820/recimundo/4.(4).octubre.2020.4-12">https://doi.org/10.26820/recimundo/4.(4).octubre.2020.4-12</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Jiménez</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Grijalva</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Ponce</surname>
							<given-names>H</given-names>
						</name>
					</person-group>
					<article-title>Plasma acoplado inductivamente en espectroscopia de emisión óptica (ICP-OES)</article-title>
					<source>Recimundo</source>
					<year>2020</year>
					<volume>4</volume>
					<issue>4</issue>
					<fpage>4</fpage>
					<lpage>12</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.26820/recimundo/4.(4).octubre.2020.4-12">https://doi.org/10.26820/recimundo/4.(4).octubre.2020.4-12</ext-link>
				</element-citation>
			</ref>
			<ref id="B4">
				<label>[4]</label>
				<mixed-citation>[4] Trujillo E, Fonseca G, García M, Martínez V. Evaluación de la Cromatografía Iónica para fomentar su uso en la investigación y estudios de posgrado en ciencias del agua. Formación universitaria. 2009;21. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.4067/s071850062009000100003">https://doi.org/10.4067/s071850062009000100003</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Trujillo</surname>
							<given-names>E</given-names>
						</name>
						<name>
							<surname>Fonseca</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>García</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Martínez</surname>
							<given-names>V</given-names>
						</name>
					</person-group>
					<article-title>Evaluación de la Cromatografía Iónica para fomentar su uso en la investigación y estudios de posgrado en ciencias del agua</article-title>
					<source>Formación universitaria</source>
					<year>2009</year>
					<volume>2</volume>
					<issue>1</issue>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.4067/s071850062009000100003">https://doi.org/10.4067/s071850062009000100003</ext-link>
				</element-citation>
			</ref>
			<ref id="B5">
				<label>[5]</label>
				<mixed-citation>[5] XRF scientific. Limitaciones de la tecnología de fluorescencia de rayos X. 2015. <ext-link ext-link-type="uri" xlink:href="https://es.xrfscientific.com/limitaciones-de-la-tecnologia-de-fluorescencia-de-rayos-x/">https://es.xrfscientific.com/limitaciones-de-la-tecnologia-de-fluorescencia-de-rayos-x/</ext-link>
				</mixed-citation>
				<element-citation publication-type="webpage">
					<person-group person-group-type="author">
						<collab>XRF scientific</collab>
					</person-group>
					<source>Limitaciones de la tecnología de fluorescencia de rayos X</source>
					<year>2015</year>
					<ext-link ext-link-type="uri" xlink:href="https://es.xrfscientific.com/limitaciones-de-la-tecnologia-de-fluorescencia-de-rayos-x/">https://es.xrfscientific.com/limitaciones-de-la-tecnologia-de-fluorescencia-de-rayos-x/</ext-link>
				</element-citation>
			</ref>
			<ref id="B6">
				<label>[6]</label>
				<mixed-citation>[6] Wobrauschek P. Total reflection x-ray fluorescence analysis—a review. X-Ray Spectrometry. 2007;361289-300. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/xrs">https://doi.org/10.1002/xrs</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Wobrauschek</surname>
							<given-names>P</given-names>
						</name>
					</person-group>
					<article-title>Total reflection x-ray fluorescence analysis—a review</article-title>
					<source>X-Ray Spectrometry</source>
					<year>2007</year>
					<volume>36</volume>
					<issue>1</issue>
					<fpage>289</fpage>
					<lpage>300</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/xrs">https://doi.org/10.1002/xrs</ext-link>
				</element-citation>
			</ref>
			<ref id="B7">
				<label>[7]</label>
				<mixed-citation>[7] Radtke M, Reinholz U, Riesemeier H. Synchrotron Radiation Induced X-Ray Fluorescence for the characterization of ancient gold objects. ArchéoSciences. 2009;3339-44. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.4000/archeosciences.1969">https://doi.org/10.4000/archeosciences.1969</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Radtke</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Reinholz</surname>
							<given-names>U</given-names>
						</name>
						<name>
							<surname>Riesemeier</surname>
							<given-names>H</given-names>
						</name>
					</person-group>
					<article-title>Synchrotron Radiation Induced X-Ray Fluorescence for the characterization of ancient gold objects</article-title>
					<source>ArchéoSciences</source>
					<year>2009</year>
					<issue>33</issue>
					<fpage>39</fpage>
					<lpage>44</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.4000/archeosciences.1969">https://doi.org/10.4000/archeosciences.1969</ext-link>
				</element-citation>
			</ref>
			<ref id="B8">
				<label>[8]</label>
				<mixed-citation>[8] Tallandini L, et al. Naturally occurring levels of elements in fishes as determined by PIXE y XRF methods. Nuclear Instruments y Methods in Physics Research. 1989;4041630-634. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/0168583X(89)91063-X">https://doi.org/10.1016/0168583X(89)91063-X</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Tallandini</surname>
							<given-names>L</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>Naturally occurring levels of elements in fishes as determined by PIXE y XRF methods</article-title>
					<source>Nuclear Instruments y Methods in Physics Research</source>
					<year>1989</year>
					<volume>40</volume>
					<issue>41</issue>
					<fpage>630</fpage>
					<lpage>634</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/0168583X(89)91063-X">https://doi.org/10.1016/0168583X(89)91063-X</ext-link>
				</element-citation>
			</ref>
			<ref id="B9">
				<label>[9]</label>
				<mixed-citation>[9] Castro M. Activación Néutrónica Cíclica para la determinación del contenido en fluor de muestras de mineral de fluorita. tesis doctoral. Universidad de Oviedo. Oviedo. 2012. <ext-link ext-link-type="uri" xlink:href="https://core.ac.uk/download/pdf/71839524.pdf">https://core.ac.uk/download/pdf/71839524.pdf</ext-link>
				</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>Castro</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<source>Activación Néutrónica Cíclica para la determinación del contenido en fluor de muestras de mineral de fluorita</source>
					<comment content-type="degree">tesis doctoral</comment>
					<publisher-name>Universidad de Oviedo</publisher-name>
					<publisher-loc>Oviedo</publisher-loc>
					<year>2012</year>
					<ext-link ext-link-type="uri" xlink:href="https://core.ac.uk/download/pdf/71839524.pdf">https://core.ac.uk/download/pdf/71839524.pdf</ext-link>
				</element-citation>
			</ref>
			<ref id="B10">
				<label>[10]</label>
				<mixed-citation>[10] Li F, Ge L, Tang Z, Chen Y, Wang J. Recent developments on XRF spectra evaluation. Applied Spectroscopy Reviews. 2020;554263-287. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1080/05704928.2019.1580715">https://doi.org/10.1080/05704928.2019.1580715</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Li</surname>
							<given-names>F</given-names>
						</name>
						<name>
							<surname>Ge</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>Tang</surname>
							<given-names>Z</given-names>
						</name>
						<name>
							<surname>Chen</surname>
							<given-names>Y</given-names>
						</name>
						<name>
							<surname>Wang</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<article-title>Recent developments on XRF spectra evaluation</article-title>
					<source>Applied Spectroscopy Reviews</source>
					<year>2020</year>
					<volume>55</volume>
					<issue>4</issue>
					<fpage>263</fpage>
					<lpage>287</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1080/05704928.2019.1580715">https://doi.org/10.1080/05704928.2019.1580715</ext-link>
				</element-citation>
			</ref>
			<ref id="B11">
				<label>[11]</label>
				<mixed-citation>[11] Dalipi R, Marguí E, Borgese L, Bilo F, Depero LE. Analytical performance of benchtop total reflection X-ray fluorescence instrumentation for multielemental analysis of wine samples. Spectrochimica Acta Part B Atomic Spectroscopy. 2016;12037-43. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.sab.2016.04.001">https://doi.org/10.1016/j.sab.2016.04.001</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Dalipi</surname>
							<given-names>R</given-names>
						</name>
						<name>
							<surname>Marguí</surname>
							<given-names>E</given-names>
						</name>
						<name>
							<surname>Borgese</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>Bilo</surname>
							<given-names>F</given-names>
						</name>
						<name>
							<surname>Depero</surname>
							<given-names>LE</given-names>
						</name>
					</person-group>
					<article-title>Analytical performance of benchtop total reflection X-ray fluorescence instrumentation for multielemental analysis of wine samples</article-title>
					<source>Spectrochimica Acta Part B Atomic Spectroscopy</source>
					<year>2016</year>
					<volume>120</volume>
					<fpage>37</fpage>
					<lpage>43</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.sab.2016.04.001">https://doi.org/10.1016/j.sab.2016.04.001</ext-link>
				</element-citation>
			</ref>
			<ref id="B12">
				<label>[12]</label>
				<mixed-citation>[12] Bruker. ¿Cómo funciona la TXRF?. 2024. <ext-link ext-link-type="uri" xlink:href="https://www.bruker.com/es/landingpages/bna/how-does-TXRF-work.html">https://www.bruker.com/es/landingpages/bna/how-does-TXRF-work.html</ext-link>
				</mixed-citation>
				<element-citation publication-type="webpage">
					<person-group person-group-type="author">
						<collab>Bruker</collab>
					</person-group>
					<source>¿Cómo funciona la TXRF?</source>
					<year>2024</year>
					<ext-link ext-link-type="uri" xlink:href="https://www.bruker.com/es/landingpages/bna/how-does-TXRF-work.html">https://www.bruker.com/es/landingpages/bna/how-does-TXRF-work.html</ext-link>
				</element-citation>
			</ref>
			<ref id="B13">
				<label>[13]</label>
				<mixed-citation>[13] Moradi M, Yamini Y, Kakehmam J, Ahmadi K. A review in the sample preparation of aqueous solutions combined with X-ray fluorescence detection. Journal of the Iranian Chemical Society. 2015;125831-838. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s13738-014-0545-0">https://doi.org/10.1007/s13738-014-0545-0</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Moradi</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Yamini</surname>
							<given-names>Y</given-names>
						</name>
						<name>
							<surname>Kakehmam</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Ahmadi</surname>
							<given-names>K</given-names>
						</name>
					</person-group>
					<article-title>A review in the sample preparation of aqueous solutions combined with X-ray fluorescence detection</article-title>
					<source>Journal of the Iranian Chemical Society</source>
					<year>2015</year>
					<volume>12</volume>
					<issue>5</issue>
					<fpage>831</fpage>
					<lpage>838</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s13738-014-0545-0">https://doi.org/10.1007/s13738-014-0545-0</ext-link>
				</element-citation>
			</ref>
			<ref id="B14">
				<label>[14]</label>
				<mixed-citation>[14] Molina A. Validación del método de determinación de azufre en combustibles por Fluorescencia de Rayos X. tesis de grado. Instituto Tecnológico de Tuxtla Gutierréz. Chiapas. 2011. <ext-link ext-link-type="uri" xlink:href="http://repositoriodigital.tuxtla.tecnm.mx/xmlui/handle/123456789/701?show=full">http://repositoriodigital.tuxtla.tecnm.mx/xmlui/handle/123456789/701?show=full</ext-link>
				</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>Molina</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<source>Validación del método de determinación de azufre en combustibles por Fluorescencia de Rayos X</source>
					<comment content-type="degree">tesis de grado</comment>
					<publisher-name>Instituto Tecnológico de Tuxtla Gutierréz</publisher-name>
					<publisher-loc>Chiapas</publisher-loc>
					<year>2011</year>
					<ext-link ext-link-type="uri" xlink:href="http://repositoriodigital.tuxtla.tecnm.mx/xmlui/handle/123456789/701?show=full">http://repositoriodigital.tuxtla.tecnm.mx/xmlui/handle/123456789/701?show=full</ext-link>
				</element-citation>
			</ref>
			<ref id="B15">
				<label>[15]</label>
				<mixed-citation>[15] Aldazabal V, Silveira M, Custo G, Ortiz M. Colores al norte del Lago Traful, Neuquén, Argentina. Boletin del Museo Chileno de Arte Precolombino. 2014;19295-105. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.4067/S0718-68942014000200006">https://doi.org/10.4067/S0718-68942014000200006</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Aldazabal</surname>
							<given-names>V</given-names>
						</name>
						<name>
							<surname>Silveira</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Custo</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>Ortiz</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<article-title>Colores al norte del Lago Traful, Neuquén, Argentina</article-title>
					<source>Boletin del Museo Chileno de Arte Precolombino</source>
					<year>2014</year>
					<volume>19</volume>
					<issue>2</issue>
					<fpage>95</fpage>
					<lpage>105</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.4067/S0718-68942014000200006">https://doi.org/10.4067/S0718-68942014000200006</ext-link>
				</element-citation>
			</ref>
			<ref id="B16">
				<label>[16]</label>
				<mixed-citation>[16] Moreno M. Aplicación de análisis de componentes principales y conglomerados a datos de Fluorescencia de Rayos X (FRX) en suelos. tesis de especialización. Fundación Universitaria Los Libertadores. Bogotá. 2019. <ext-link ext-link-type="uri" xlink:href="https://repository.libertadores.edu.co/server/api/core/bitstreams/d4df816d-d614-4dfa-87a6-a3e096f64aac/content">https://repository.libertadores.edu.co/server/api/core/bitstreams/d4df816d-d614-4dfa-87a6-a3e096f64aac/content</ext-link>
				</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>Moreno</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<source>Aplicación de análisis de componentes principales y conglomerados a datos de Fluorescencia de Rayos X (FRX) en suelos</source>
					<comment content-type="degree">tesis de especialización</comment>
					<publisher-name>Fundación Universitaria Los Libertadores</publisher-name>
					<publisher-loc>Bogotá</publisher-loc>
					<year>2019</year>
					<ext-link ext-link-type="uri" xlink:href="https://repository.libertadores.edu.co/server/api/core/bitstreams/d4df816d-d614-4dfa-87a6-a3e096f64aac/content">https://repository.libertadores.edu.co/server/api/core/bitstreams/d4df816d-d614-4dfa-87a6-a3e096f64aac/content</ext-link>
				</element-citation>
			</ref>
			<ref id="B17">
				<label>[17]</label>
				<mixed-citation>[17] Uo M, Wada T, Sugiyama T. Applications of X-ray fluorescence analysis (XRF) to dental y medical specimens. Japanese Dental Science Review. 2015;51 12-9. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jdsr.2014.07.001">https://doi.org/10.1016/j.jdsr.2014.07.001</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Uo</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Wada</surname>
							<given-names>T</given-names>
						</name>
						<name>
							<surname>Sugiyama</surname>
							<given-names>T.</given-names>
						</name>
					</person-group>
					<article-title>Applications of X-ray fluorescence analysis (XRF) to dental y medical specimens</article-title>
					<source>Japanese Dental Science Review</source>
					<year>2015</year>
					<volume>51</volume>
					<issue>1</issue>
					<fpage>2</fpage>
					<lpage>9</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jdsr.2014.07.001">https://doi.org/10.1016/j.jdsr.2014.07.001</ext-link>
				</element-citation>
			</ref>
			<ref id="B18">
				<label>[18]</label>
				<mixed-citation>[18] Consejo de Seguridad Nuclear. Tema 2: Interacción de la radiación con la materia. 2021. <ext-link ext-link-type="uri" xlink:href="https://csn.ciemat.es/MDCSN/recursos/ficheros_md/133100241_2411200913036.pdf">https://csn.ciemat.es/MDCSN/recursos/ficheros_md/133100241_2411200913036.pdf</ext-link>
				</mixed-citation>
				<element-citation publication-type="webpage">
					<person-group person-group-type="author">
						<collab>Consejo de Seguridad Nuclear</collab>
					</person-group>
					<source>Tema 2: Interacción de la radiación con la materia</source>
					<year>2021</year>
					<ext-link ext-link-type="uri" xlink:href="https://csn.ciemat.es/MDCSN/recursos/ficheros_md/133100241_2411200913036.pdf">https://csn.ciemat.es/MDCSN/recursos/ficheros_md/133100241_2411200913036.pdf</ext-link>
				</element-citation>
			</ref>
			<ref id="B19">
				<label>[19]</label>
				<mixed-citation>[19] Montufar D. Simulación de los efectos radiobiológicos en el ADN inducidos por partículas alfa del Ra 223 utilizando Geant4-DNA. tesis de maestría. Universidad Nacional de Colombia. Bogotá. 2021. <ext-link ext-link-type="uri" xlink:href="https://repositorio.unal.edu.co/bitstream/handle/unal/79848/1085282844.2021.pdf">https://repositorio.unal.edu.co/bitstream/handle/unal/79848/1085282844.2021.pdf</ext-link>
				</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>Montufar</surname>
							<given-names>D</given-names>
						</name>
					</person-group>
					<source>Simulación de los efectos radiobiológicos en el ADN inducidos por partículas alfa del Ra 223 utilizando Geant4-DNA</source>
					<comment content-type="degree">tesis de maestría</comment>
					<publisher-name>Universidad Nacional de Colombia</publisher-name>
					<publisher-loc>Bogotá</publisher-loc>
					<year>2021</year>
					<ext-link ext-link-type="uri" xlink:href="https://repositorio.unal.edu.co/bitstream/handle/unal/79848/1085282844.2021.pdf">https://repositorio.unal.edu.co/bitstream/handle/unal/79848/1085282844.2021.pdf</ext-link>
				</element-citation>
			</ref>
			<ref id="B20">
				<label>[20]</label>
				<mixed-citation>[20] González M. Programación de un sistema de adquisición de datos para detectores de radiación. tesis de grado. Universidad Carlos III de Madrid. Leganés. 2015.</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>González</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<source>Programación de un sistema de adquisición de datos para detectores de radiación</source>
					<comment content-type="degree">tesis de grado</comment>
					<publisher-name>Universidad Carlos III de Madrid</publisher-name>
					<publisher-loc>Leganés</publisher-loc>
					<year>2015</year>
				</element-citation>
			</ref>
			<ref id="B21">
				<label>[21]</label>
				<mixed-citation>[21] Díaz J. Desarrollo de un código para el transporte de fotones ionizantes en agua con la técnica evento-por-evento. tesis de maestría. Universidad Autónoma del Estado de México. Toluca. 2017. <ext-link ext-link-type="uri" xlink:href="http://ri.uaemex.mx/bitstream/handle/20.500.11799/69412/Tesis%20JorgeDiaz.pdf">http://ri.uaemex.mx/bitstream/handle/20.500.11799/69412/Tesis%20JorgeDiaz.pdf</ext-link>
				</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>Díaz</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<source>Desarrollo de un código para el transporte de fotones ionizantes en agua con la técnica evento-por-evento</source>
					<comment content-type="degree">tesis de maestría</comment>
					<publisher-name>Universidad Autónoma del Estado de México</publisher-name>
					<publisher-loc>Toluca</publisher-loc>
					<year>2017</year>
					<ext-link ext-link-type="uri" xlink:href="http://ri.uaemex.mx/bitstream/handle/20.500.11799/69412/Tesis%20JorgeDiaz.pdf">http://ri.uaemex.mx/bitstream/handle/20.500.11799/69412/Tesis%20JorgeDiaz.pdf</ext-link>
				</element-citation>
			</ref>
			<ref id="B22">
				<label>[22]</label>
				<mixed-citation>[22] Amado J. Estudio de los mecanismos de cristalización y maduración de fosfatos de calcio en medio biológico usando radiación de sincrotrón. tesis de grado. Universidad Nacional de Córdoba. Córdoba. 2009. <ext-link ext-link-type="uri" xlink:href="https://rdu.unc.edu.ar/bitstream/handle/11086/150/DFis135.pdf?sequence=1&amp;isAllowed=y">https://rdu.unc.edu.ar/bitstream/handle/11086/150/DFis135.pdf?sequence=1&amp;isAllowed=y</ext-link>
				</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>Amado</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<source>Estudio de los mecanismos de cristalización y maduración de fosfatos de calcio en medio biológico usando radiación de sincrotrón</source>
					<comment content-type="degree">tesis de grado</comment>
					<publisher-name>Universidad Nacional de Córdoba</publisher-name>
					<publisher-loc>Córdoba</publisher-loc>
					<year>2009</year>
					<ext-link ext-link-type="uri" xlink:href="https://rdu.unc.edu.ar/bitstream/handle/11086/150/DFis135.pdf?sequence=1&amp;isAllowed=y">https://rdu.unc.edu.ar/bitstream/handle/11086/150/DFis135.pdf?sequence=1&amp;isAllowed=y</ext-link>
				</element-citation>
			</ref>
			<ref id="B23">
				<label>[23]</label>
				<mixed-citation>[23] Viñas F, Hernández F, Panelo M, Salazar I, Muglia J. Determinación de la composición de materiales mediante la Fluorescencia de Rayos X. 2007. <ext-link ext-link-type="uri" xlink:href="https://franchsebs.wordpress.com/wp-content/uploads/2007/12/91.pdf">https://franchsebs.wordpress.com/wp-content/uploads/2007/12/91.pdf</ext-link>
				</mixed-citation>
				<element-citation publication-type="webpage">
					<person-group person-group-type="author">
						<name>
							<surname>Viñas</surname>
							<given-names>F</given-names>
						</name>
						<name>
							<surname>Hernández</surname>
							<given-names>F</given-names>
						</name>
						<name>
							<surname>Panelo</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Salazar</surname>
							<given-names>I</given-names>
						</name>
						<name>
							<surname>Muglia</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<source>Determinación de la composición de materiales mediante la Fluorescencia de Rayos X</source>
					<year>2007</year>
					<ext-link ext-link-type="uri" xlink:href="https://franchsebs.wordpress.com/wp-content/uploads/2007/12/91.pdf">https://franchsebs.wordpress.com/wp-content/uploads/2007/12/91.pdf</ext-link>
				</element-citation>
			</ref>
			<ref id="B24">
				<label>[24]</label>
				<mixed-citation>[24] Dolenko G, Poleshchuk O, Latosiñska J. X-ray emission spectroscopy, methods. Encyclopedia of Spectroscopy y Spectrometry. 2017;3691-694. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/B978-0-12-803224-4.00313-7">https://doi.org/10.1016/B978-0-12-803224-4.00313-7</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Dolenko</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>Poleshchuk</surname>
							<given-names>O</given-names>
						</name>
						<name>
							<surname>Latosiñska</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<article-title>X-ray emission spectroscopy, methods</article-title>
					<source>Encyclopedia of Spectroscopy y Spectrometry</source>
					<year>2017</year>
					<volume>3</volume>
					<fpage>691</fpage>
					<lpage>694</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/B978-0-12-803224-4.00313-7">https://doi.org/10.1016/B978-0-12-803224-4.00313-7</ext-link>
				</element-citation>
			</ref>
			<ref id="B25">
				<label>[25]</label>
				<mixed-citation>[25] Da-Col J, Sanchez R, Terra J, Bueno M. Análise exploratória rápida e não destrutiva (Screening) da presença de elementos químicos tóxicos em material escolar por fluorescência de raios X. Quimica Nova. 2013;366874-879. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1590/S0100-40422013000600023">https://doi.org/10.1590/S0100-40422013000600023</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Da-Col</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Sanchez</surname>
							<given-names>R</given-names>
						</name>
						<name>
							<surname>Terra</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Bueno</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<article-title>Análise exploratória rápida e não destrutiva (Screening) da presença de elementos químicos tóxicos em material escolar por fluorescência de raios X</article-title>
					<source>Quimica Nova</source>
					<year>2013</year>
					<volume>36</volume>
					<issue>6</issue>
					<fpage>874</fpage>
					<lpage>879</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1590/S0100-40422013000600023">https://doi.org/10.1590/S0100-40422013000600023</ext-link>
				</element-citation>
			</ref>
			<ref id="B26">
				<label>[26]</label>
				<mixed-citation>[26] Khalid A, Anwar S, Siddiqi S, Anwar M. Energy Dispersive X-ray Fluorescence (EDXRF) for studying coinage from the Indo-Pak subcontinent. 2011. <ext-link ext-link-type="uri" xlink:href="https://www.researchgate.net/publication/268264113_Energy_dispersive_X-ray_fluorescence_EDXRF_for_studying_coinage_from_the_Indo-Pak_subcontinent">https://www.researchgate.net/publication/268264113_Energy_dispersive_X-ray_fluorescence_EDXRF_for_studying_coinage_from_the_Indo-Pak_subcontinent</ext-link>
				</mixed-citation>
				<element-citation publication-type="webpage">
					<person-group person-group-type="author">
						<name>
							<surname>Khalid</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Anwar</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Siddiqi</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Anwar</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<source>Energy Dispersive X-ray Fluorescence (EDXRF) for studying coinage from the Indo-Pak subcontinent</source>
					<year>2011</year>
					<ext-link ext-link-type="uri" xlink:href="https://www.researchgate.net/publication/268264113_Energy_dispersive_X-ray_fluorescence_EDXRF_for_studying_coinage_from_the_Indo-Pak_subcontinent">https://www.researchgate.net/publication/268264113_Energy_dispersive_X-ray_fluorescence_EDXRF_for_studying_coinage_from_the_Indo-Pak_subcontinent</ext-link>
				</element-citation>
			</ref>
			<ref id="B27">
				<label>[27]</label>
				<mixed-citation>[27] Navas M, Asuero A, Jimenez A. A review of energy dispersive X-ray fluorescence (EDXRF) as an analytical tool in numismatic studies. Applied Spectroscopy. 2016;701207-221. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1177/0003702815616594">https://doi.org/10.1177/0003702815616594</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Navas</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Asuero</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Jimenez</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<article-title>A review of energy dispersive X-ray fluorescence (EDXRF) as an analytical tool in numismatic studies</article-title>
					<source>Applied Spectroscopy</source>
					<year>2016</year>
					<volume>70</volume>
					<issue>1</issue>
					<fpage>207</fpage>
					<lpage>221</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1177/0003702815616594">https://doi.org/10.1177/0003702815616594</ext-link>
				</element-citation>
			</ref>
			<ref id="B28">
				<label>[28]</label>
				<mixed-citation>[28] Pushie J, Pickering I, Korbas M, Hackett M, George G. Elemental y chemically specific x-ray fluorescence imaging of biological systems. Chemical Reviews. 2014;114178499-8541. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1021/cr4007297">https://doi.org/10.1021/cr4007297</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Pushie</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Pickering</surname>
							<given-names>I</given-names>
						</name>
						<name>
							<surname>Korbas</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Hackett</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>George</surname>
							<given-names>G</given-names>
						</name>
					</person-group>
					<article-title>Elemental y chemically specific x-ray fluorescence imaging of biological systems</article-title>
					<source>Chemical Reviews</source>
					<year>2014</year>
					<volume>114</volume>
					<issue>17</issue>
					<fpage>8499</fpage>
					<lpage>8541</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1021/cr4007297">https://doi.org/10.1021/cr4007297</ext-link>
				</element-citation>
			</ref>
			<ref id="B29">
				<label>[29]</label>
				<mixed-citation>[29] Jenkins R. X-Ray Techniques: Overview. Encyclopedia of Analytical Chemistry. John Wiley &amp; Sons Ltd.. 2006;11-20. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/9780470027318.a6801">https://doi.org/10.1002/9780470027318.a6801</ext-link>
				</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Jenkins</surname>
							<given-names>R</given-names>
						</name>
					</person-group>
					<chapter-title>X-Ray Techniques: Overview</chapter-title>
					<source>Encyclopedia of Analytical Chemistry</source>
					<publisher-name>John Wiley &amp; Sons Ltd.</publisher-name>
					<year>2006</year>
					<volume>1</volume>
					<fpage>1</fpage>
					<lpage>20</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/9780470027318.a6801">https://doi.org/10.1002/9780470027318.a6801</ext-link>
				</element-citation>
			</ref>
			<ref id="B30">
				<label>[30]</label>
				<mixed-citation>[30] Heckel J, Haschke M, Brumme M, Schindler R. Principles y Applications of Energy-dispersive X-ray Fluorescence Analysis With Polarized Radiation. Journal of Analytical Atomic Spectrometry. 1992;7281-286.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Heckel</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Haschke</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Brumme</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Schindler</surname>
							<given-names>R</given-names>
						</name>
					</person-group>
					<article-title>Principles y Applications of Energy-dispersive X-ray Fluorescence Analysis With Polarized Radiation</article-title>
					<source>Journal of Analytical Atomic Spectrometry</source>
					<year>1992</year>
					<volume>7</volume>
					<fpage>281</fpage>
					<lpage>286</lpage>
				</element-citation>
			</ref>
			<ref id="B31">
				<label>[31]</label>
				<mixed-citation>[31] Wobrauschek P, Streli C, Selin Lindgren E. Energy Dispersive, X-Ray Fluorescence Analysis X-Ray Spectrometry. Encyclopedia of Analytical Chemistry. John Wiley &amp; Sons Ltd.. 2010;31-17. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/9780470027318.A6806.PUB2">https://doi.org/10.1002/9780470027318.A6806.PUB2</ext-link>
				</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Wobrauschek</surname>
							<given-names>P</given-names>
						</name>
						<name>
							<surname>Streli</surname>
							<given-names>C</given-names>
						</name>
						<name>
							<surname>Selin Lindgren</surname>
							<given-names>E</given-names>
						</name>
					</person-group>
					<chapter-title>Energy Dispersive, X-Ray Fluorescence Analysis X-Ray Spectrometry</chapter-title>
					<source>Encyclopedia of Analytical Chemistry</source>
					<publisher-name>John Wiley &amp; Sons Ltd.</publisher-name>
					<year>2010</year>
					<volume>3</volume>
					<fpage>1</fpage>
					<lpage>17</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/9780470027318.A6806.PUB2">https://doi.org/10.1002/9780470027318.A6806.PUB2</ext-link>
				</element-citation>
			</ref>
			<ref id="B32">
				<label>[32]</label>
				<mixed-citation>[32] Yi L, et al. A new background subtraction method for energy dispersive X-ray fluorescence spectra using a cubic spline interpolation. Nuclear Instruments y Methods in Physics Research A. 2015;77512-14. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.nima.2014.11.100">https://doi.org/10.1016/j.nima.2014.11.100</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Yi</surname>
							<given-names>L</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>A new background subtraction method for energy dispersive X-ray fluorescence spectra using a cubic spline interpolation</article-title>
					<source>Nuclear Instruments y Methods in Physics Research A</source>
					<year>2015</year>
					<volume>775</volume>
					<fpage>12</fpage>
					<lpage>14</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.nima.2014.11.100">https://doi.org/10.1016/j.nima.2014.11.100</ext-link>
				</element-citation>
			</ref>
			<ref id="B33">
				<label>[33]</label>
				<mixed-citation>[33] Schramm R. Use of X-ray fluorescence analysis for the determination of rare earth elements. Physical Sciences Reviews. 2016;19. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1515/psr-2016-0061">https://doi.org/10.1515/psr-2016-0061</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Schramm</surname>
							<given-names>R</given-names>
						</name>
					</person-group>
					<article-title>Use of X-ray fluorescence analysis for the determination of rare earth elements</article-title>
					<source>Physical Sciences Reviews</source>
					<year>2016</year>
					<volume>1</volume>
					<issue>9</issue>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1515/psr-2016-0061">https://doi.org/10.1515/psr-2016-0061</ext-link>
				</element-citation>
			</ref>
			<ref id="B34">
				<label>[34]</label>
				<mixed-citation>[34] Bruker. ¿Cómo funciona XRF? - WDXRF. 2024. <ext-link ext-link-type="uri" xlink:href="https://www.bruker.com/es/products-andsolutions/elemental-analyzers/xrf-spectrometers/how-does-xrf-work.html">https://www.bruker.com/es/products-andsolutions/elemental-analyzers/xrf-spectrometers/how-does-xrf-work.html</ext-link>
				</mixed-citation>
				<element-citation publication-type="webpage">
					<person-group person-group-type="author">
						<collab>Bruker</collab>
					</person-group>
					<source>¿Cómo funciona XRF? - WDXRF</source>
					<year>2024</year>
					<ext-link ext-link-type="uri" xlink:href="https://www.bruker.com/es/products-andsolutions/elemental-analyzers/xrf-spectrometers/how-does-xrf-work.html">https://www.bruker.com/es/products-andsolutions/elemental-analyzers/xrf-spectrometers/how-does-xrf-work.html</ext-link>
				</element-citation>
			</ref>
			<ref id="B35">
				<label>[35]</label>
				<mixed-citation>[35] Millholland C. Fluorescencia de Rayos X para monitoreo ambiental. 2021. <ext-link ext-link-type="uri" xlink:href="https://www.thermofisher.com/blog/cienciaacelerada/materiales/fluorescencia-de-rayos-x-para-monitoreo-ambiental/">https://www.thermofisher.com/blog/cienciaacelerada/materiales/fluorescencia-de-rayos-x-para-monitoreo-ambiental/</ext-link>
				</mixed-citation>
				<element-citation publication-type="webpage">
					<person-group person-group-type="author">
						<name>
							<surname>Millholland</surname>
							<given-names>C</given-names>
						</name>
					</person-group>
					<source>Fluorescencia de Rayos X para monitoreo ambiental</source>
					<year>2021</year>
					<ext-link ext-link-type="uri" xlink:href="https://www.thermofisher.com/blog/cienciaacelerada/materiales/fluorescencia-de-rayos-x-para-monitoreo-ambiental/">https://www.thermofisher.com/blog/cienciaacelerada/materiales/fluorescencia-de-rayos-x-para-monitoreo-ambiental/</ext-link>
				</element-citation>
			</ref>
			<ref id="B36">
				<label>[36]</label>
				<mixed-citation>[36] Bruker. Periodic Table of the Elements. 2023. <ext-link ext-link-type="uri" xlink:href="https://es.scribd.com/document/339282717/Tabla-Periodica-Bruker-pdf">https://es.scribd.com/document/339282717/Tabla-Periodica-Bruker-pdf</ext-link>
				</mixed-citation>
				<element-citation publication-type="webpage">
					<person-group person-group-type="author">
						<collab>Bruker</collab>
					</person-group>
					<source>Periodic Table of the Elements</source>
					<year>2023</year>
					<ext-link ext-link-type="uri" xlink:href="https://es.scribd.com/document/339282717/Tabla-Periodica-Bruker-pdf">https://es.scribd.com/document/339282717/Tabla-Periodica-Bruker-pdf</ext-link>
				</element-citation>
			</ref>
			<ref id="B37">
				<label>[37]</label>
				<mixed-citation>[37] Dynatech International. Conceptos básicos de los principios de funcionamiento de XRF. 2023. <ext-link ext-link-type="uri" xlink:href="https://dynatech-int.com/id/page/5/?p=page-18480">https://dynatech-int.com/id/page/5/?p=page-18480</ext-link>
				</mixed-citation>
				<element-citation publication-type="webpage">
					<person-group person-group-type="author">
						<collab>Dynatech International</collab>
					</person-group>
					<source>Conceptos básicos de los principios de funcionamiento de XRF</source>
					<year>2023</year>
					<ext-link ext-link-type="uri" xlink:href="https://dynatech-int.com/id/page/5/?p=page-18480">https://dynatech-int.com/id/page/5/?p=page-18480</ext-link>
				</element-citation>
			</ref>
			<ref id="B38">
				<label>[38]</label>
				<mixed-citation>[38] Malvern Panalytical. Fluorescencia de rayos X de dispersión por longitud de onda (WDXRF). 2021. <ext-link ext-link-type="uri" xlink:href="https://www.malvernpanalytical.com/es/products/technology/xray-analysis/x-ray-fluorescence/wavelength-dispersive-x-ray-fluorescence">https://www.malvernpanalytical.com/es/products/technology/xray-analysis/x-ray-fluorescence/wavelength-dispersive-x-ray-fluorescence</ext-link>
				</mixed-citation>
				<element-citation publication-type="webpage">
					<person-group person-group-type="author">
						<collab>Malvern Panalytical</collab>
					</person-group>
					<source>Fluorescencia de rayos X de dispersión por longitud de onda (WDXRF)</source>
					<year>2021</year>
					<ext-link ext-link-type="uri" xlink:href="https://www.malvernpanalytical.com/es/products/technology/xray-analysis/x-ray-fluorescence/wavelength-dispersive-x-ray-fluorescence">https://www.malvernpanalytical.com/es/products/technology/xray-analysis/x-ray-fluorescence/wavelength-dispersive-x-ray-fluorescence</ext-link>
				</element-citation>
			</ref>
			<ref id="B39">
				<label>[39]</label>
				<mixed-citation>[39] Kingland E. ¿Cómo utilizar un XRF portátil para PMI?. 2024. <ext-link ext-link-type="uri" xlink:href="https://www.sweetfishmedia.com/blog/handheld-xrf-for-pmi">https://www.sweetfishmedia.com/blog/handheld-xrf-for-pmi</ext-link>
				</mixed-citation>
				<element-citation publication-type="webpage">
					<person-group person-group-type="author">
						<name>
							<surname>Kingland</surname>
							<given-names>E</given-names>
						</name>
					</person-group>
					<source>¿Cómo utilizar un XRF portátil para PMI?</source>
					<year>2024</year>
					<ext-link ext-link-type="uri" xlink:href="https://www.sweetfishmedia.com/blog/handheld-xrf-for-pmi">https://www.sweetfishmedia.com/blog/handheld-xrf-for-pmi</ext-link>
				</element-citation>
			</ref>
			<ref id="B40">
				<label>[40]</label>
				<mixed-citation>[40] Bruker. Handheld XRF: How it works?. 2024. <ext-link ext-link-type="uri" xlink:href="https://www.bruker.com/en/products-and-solutions/elemental-analyzers/handheld-xrf-spectrometers/how-xrf-works.html">https://www.bruker.com/en/products-and-solutions/elemental-analyzers/handheld-xrf-spectrometers/how-xrf-works.html</ext-link>
				</mixed-citation>
				<element-citation publication-type="webpage">
					<person-group person-group-type="author">
						<collab>Bruker</collab>
					</person-group>
					<source>Handheld XRF: How it works?</source>
					<year>2024</year>
					<ext-link ext-link-type="uri" xlink:href="https://www.bruker.com/en/products-and-solutions/elemental-analyzers/handheld-xrf-spectrometers/how-xrf-works.html">https://www.bruker.com/en/products-and-solutions/elemental-analyzers/handheld-xrf-spectrometers/how-xrf-works.html</ext-link>
				</element-citation>
			</ref>
			<ref id="B41">
				<label>[41]</label>
				<mixed-citation>[41] Thermo Fisher Scientific. How does handheld XRF work?. 2024. <ext-link ext-link-type="uri" xlink:href="https://www.thermofisher.com/co/en/home/industrial/spectroscopy-elemental-isotope-analysis/spectroscopy-elemental-isotope-analysis-learning-center/elemental-analysis-information/xrf-technology.html">https://www.thermofisher.com/co/en/home/industrial/spectroscopy-elemental-isotope-analysis/spectroscopy-elemental-isotope-analysis-learning-center/elemental-analysis-information/xrf-technology.html</ext-link>
				</mixed-citation>
				<element-citation publication-type="webpage">
					<person-group person-group-type="author">
						<collab>Thermo Fisher Scientific</collab>
					</person-group>
					<source>How does handheld XRF work?</source>
					<year>2024</year>
					<ext-link ext-link-type="uri" xlink:href="https://www.thermofisher.com/co/en/home/industrial/spectroscopy-elemental-isotope-analysis/spectroscopy-elemental-isotope-analysis-learning-center/elemental-analysis-information/xrf-technology.html">https://www.thermofisher.com/co/en/home/industrial/spectroscopy-elemental-isotope-analysis/spectroscopy-elemental-isotope-analysis-learning-center/elemental-analysis-information/xrf-technology.html</ext-link>
				</element-citation>
			</ref>
			<ref id="B42">
				<label>[42]</label>
				<mixed-citation>[42] Kovac S, Konopatzki P. Utilization of Portable X-Ray Fluorescence-Spectrometers for the Registration of Contaminated Sites in Vietnam. 2018.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Kovac</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Konopatzki</surname>
							<given-names>P</given-names>
						</name>
					</person-group>
					<source>Utilization of Portable X-Ray Fluorescence-Spectrometers for the Registration of Contaminated Sites in Vietnam</source>
					<year>2018</year>
				</element-citation>
			</ref>
			<ref id="B43">
				<label>[43]</label>
				<mixed-citation>[43] Guild G, Stangoulis J. EDXRF for screening micronutrients in lentil y sorghum biofortification breeding programs. Plant Soil. 2021;4631-2461-469. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s11104-021-04922-z">https://doi.org/10.1007/s11104-021-04922-z</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Guild</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>Stangoulis</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<article-title>EDXRF for screening micronutrients in lentil y sorghum biofortification breeding programs</article-title>
					<source>Plant Soil</source>
					<year>2021</year>
					<volume>463</volume>
					<issue>1-2</issue>
					<fpage>461</fpage>
					<lpage>469</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s11104-021-04922-z">https://doi.org/10.1007/s11104-021-04922-z</ext-link>
				</element-citation>
			</ref>
			<ref id="B44">
				<label>[44]</label>
				<mixed-citation>[44] Guild G, Paltridge N, Andersson M, Stangoulis J. An energy-dispersive X-ray fluorescence method for analysing Fe y Zn in common bean, maize y cowpea biofortification programs. Plant Soil. 2017;4191-2457-466. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s11104-017-3352-4">https://doi.org/10.1007/s11104-017-3352-4</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Guild</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>Paltridge</surname>
							<given-names>N</given-names>
						</name>
						<name>
							<surname>Andersson</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Stangoulis</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<article-title>An energy-dispersive X-ray fluorescence method for analysing Fe y Zn in common bean, maize y cowpea biofortification programs</article-title>
					<source>Plant Soil</source>
					<year>2017</year>
					<volume>419</volume>
					<issue>1-2</issue>
					<fpage>457</fpage>
					<lpage>466</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s11104-017-3352-4">https://doi.org/10.1007/s11104-017-3352-4</ext-link>
				</element-citation>
			</ref>
			<ref id="B45">
				<label>[45]</label>
				<mixed-citation>[45] Perring L, Andrey D. EDXRF as a tool for rapid minerals control in milk-based products. Journal of Agricultural y Food Chemistry. 2003;51154207-4212. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1021/jf034158p">https://doi.org/10.1021/jf034158p</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Perring</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>Andrey</surname>
							<given-names>D</given-names>
						</name>
					</person-group>
					<article-title>EDXRF as a tool for rapid minerals control in milk-based products</article-title>
					<source>Journal of Agricultural y Food Chemistry</source>
					<year>2003</year>
					<volume>51</volume>
					<issue>15</issue>
					<fpage>4207</fpage>
					<lpage>4212</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1021/jf034158p">https://doi.org/10.1021/jf034158p</ext-link>
				</element-citation>
			</ref>
			<ref id="B46">
				<label>[46]</label>
				<mixed-citation>[46] Sosa P, Guild G, Burgos G, Bonierbale M, zum Felde T. Potential y application of X-ray fluorescence spectrometry to estimate iron y zinc concentration in potato tubers. Journal of Food Composition y Analysis. 2018;7022-27. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jfca.2018.03.004">https://doi.org/10.1016/j.jfca.2018.03.004</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Sosa</surname>
							<given-names>P</given-names>
						</name>
						<name>
							<surname>Guild</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>Burgos</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>Bonierbale</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>zum Felde</surname>
							<given-names>T</given-names>
						</name>
					</person-group>
					<article-title>Potential y application of X-ray fluorescence spectrometry to estimate iron y zinc concentration in potato tubers</article-title>
					<source>Journal of Food Composition y Analysis</source>
					<year>2018</year>
					<volume>70</volume>
					<fpage>22</fpage>
					<lpage>27</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jfca.2018.03.004">https://doi.org/10.1016/j.jfca.2018.03.004</ext-link>
				</element-citation>
			</ref>
			<ref id="B47">
				<label>[47]</label>
				<mixed-citation>[47] Chuparina E, Chubarov V, Paradina L. A comparative determination of major components in coal power plant wastes by wavelength Dispersive X-Ray Fluorescence using pellet y fused bead specimens. Applied Radiation y Isotopes. 2019;152162-167. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.apradiso.2019.06.040">https://doi.org/10.1016/j.apradiso.2019.06.040</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Chuparina</surname>
							<given-names>E</given-names>
						</name>
						<name>
							<surname>Chubarov</surname>
							<given-names>V</given-names>
						</name>
						<name>
							<surname>Paradina</surname>
							<given-names>L</given-names>
						</name>
					</person-group>
					<article-title>A comparative determination of major components in coal power plant wastes by wavelength Dispersive X-Ray Fluorescence using pellet y fused bead specimens</article-title>
					<source>Applied Radiation y Isotopes</source>
					<year>2019</year>
					<volume>152</volume>
					<fpage>162</fpage>
					<lpage>167</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.apradiso.2019.06.040">https://doi.org/10.1016/j.apradiso.2019.06.040</ext-link>
				</element-citation>
			</ref>
			<ref id="B48">
				<label>[48]</label>
				<mixed-citation>[48] Idris A. Between-bottle homogeneity test of new certified reference materials employing wavelength dispersive X-ray fluorescence spectrometry. BMC Chem. 2019;1311-11. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1186/s13065-019-0528-4">https://doi.org/10.1186/s13065-019-0528-4</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Idris</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<article-title>Between-bottle homogeneity test of new certified reference materials employing wavelength dispersive X-ray fluorescence spectrometry</article-title>
					<source>BMC Chem</source>
					<year>2019</year>
					<volume>13</volume>
					<issue>1</issue>
					<fpage>1</fpage>
					<lpage>11</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1186/s13065-019-0528-4">https://doi.org/10.1186/s13065-019-0528-4</ext-link>
				</element-citation>
			</ref>
			<ref id="B49">
				<label>[49]</label>
				<mixed-citation>[49] Bouchard M, et al. Global cement y raw materials fusion/XRF analytical solution. Powder Diffraction. 2011;262176-185. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1154/1.3591181">https://doi.org/10.1154/1.3591181</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Bouchard</surname>
							<given-names>M</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>Global cement y raw materials fusion/XRF analytical solution</article-title>
					<source>Powder Diffraction</source>
					<year>2011</year>
					<volume>26</volume>
					<issue>2</issue>
					<fpage>176</fpage>
					<lpage>185</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1154/1.3591181">https://doi.org/10.1154/1.3591181</ext-link>
				</element-citation>
			</ref>
			<ref id="B50">
				<label>[50]</label>
				<mixed-citation>[50] Tian L, Zou D, Dai Y, Tang G. Determination of tungsten in tantalum-tungsten alloy by X-ray fluorescence spectrometry using fusion, thin layer y pressed powder pellet techniques. Spectrochimica Acta Part B. 2015;110136-138. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.sab.2015.06.007">https://doi.org/10.1016/j.sab.2015.06.007</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Tian</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>Zou</surname>
							<given-names>D</given-names>
						</name>
						<name>
							<surname>Dai</surname>
							<given-names>Y</given-names>
						</name>
						<name>
							<surname>Tang</surname>
							<given-names>G</given-names>
						</name>
					</person-group>
					<article-title>Determination of tungsten in tantalum-tungsten alloy by X-ray fluorescence spectrometry using fusion, thin layer y pressed powder pellet techniques</article-title>
					<source>Spectrochimica Acta Part B</source>
					<year>2015</year>
					<volume>110</volume>
					<fpage>136</fpage>
					<lpage>138</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.sab.2015.06.007">https://doi.org/10.1016/j.sab.2015.06.007</ext-link>
				</element-citation>
			</ref>
			<ref id="B51">
				<label>[51]</label>
				<mixed-citation>[51] Mijatović N, Vasić M, Miličić L, Radomirović M, Radojević Z. Fired pressed pellet as a sample preparation technique of choice for an energy dispersive X-ray fluorescence analysis of raw clays. Talanta. 2023;252. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.talanta.2022.123844">https://doi.org/10.1016/j.talanta.2022.123844</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Mijatović</surname>
							<given-names>N</given-names>
						</name>
						<name>
							<surname>Vasić</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Miličić</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>Radomirović</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Radojević</surname>
							<given-names>Z</given-names>
						</name>
					</person-group>
					<article-title>Fired pressed pellet as a sample preparation technique of choice for an energy dispersive X-ray fluorescence analysis of raw clays</article-title>
					<source>Talanta</source>
					<year>2023</year>
					<volume>252</volume>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.talanta.2022.123844">https://doi.org/10.1016/j.talanta.2022.123844</ext-link>
				</element-citation>
			</ref>
			<ref id="B52">
				<label>[52]</label>
				<mixed-citation>[52] Zhang D, Xue D, Liu Y, Wan B, Guo Q, Guo J. Comparative study of three mixing methods in fusion technique for determining major y minor elements using wavelength dispersive x-ray fluorescence spectroscopy. Sensors. 2020;20181-17. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/s20185325">https://doi.org/10.3390/s20185325</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Zhang</surname>
							<given-names>D</given-names>
						</name>
						<name>
							<surname>Xue</surname>
							<given-names>D</given-names>
						</name>
						<name>
							<surname>Liu</surname>
							<given-names>Y</given-names>
						</name>
						<name>
							<surname>Wan</surname>
							<given-names>B</given-names>
						</name>
						<name>
							<surname>Guo</surname>
							<given-names>Q</given-names>
						</name>
						<name>
							<surname>Guo</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<article-title>Comparative study of three mixing methods in fusion technique for determining major y minor elements using wavelength dispersive x-ray fluorescence spectroscopy</article-title>
					<source>Sensors</source>
					<year>2020</year>
					<volume>20</volume>
					<issue>18</issue>
					<fpage>1</fpage>
					<lpage>17</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/s20185325">https://doi.org/10.3390/s20185325</ext-link>
				</element-citation>
			</ref>
			<ref id="B53">
				<label>[53]</label>
				<mixed-citation>[53] Morales J. Cuantificación de los elementos mayoritarios en material arqueológico de la provincia Nor Lípez utilizando fluorescencia de rayos X por energía dispersiva. tesis de grado. Universidad Mayor de San Andres. La Paz. 2019. <ext-link ext-link-type="uri" xlink:href="https://repositorio.umsa.bo/bitstream/handle/123456789/25934/T-2902.pdf?sequence=1&amp;isAllowed=y">https://repositorio.umsa.bo/bitstream/handle/123456789/25934/T-2902.pdf?sequence=1&amp;isAllowed=y</ext-link>
				</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>Morales</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<source>Cuantificación de los elementos mayoritarios en material arqueológico de la provincia Nor Lípez utilizando fluorescencia de rayos X por energía dispersiva</source>
					<comment content-type="degree">tesis de grado</comment>
					<publisher-name>Universidad Mayor de San Andres</publisher-name>
					<publisher-loc>La Paz</publisher-loc>
					<year>2019</year>
					<ext-link ext-link-type="uri" xlink:href="https://repositorio.umsa.bo/bitstream/handle/123456789/25934/T-2902.pdf?sequence=1&amp;isAllowed=y">https://repositorio.umsa.bo/bitstream/handle/123456789/25934/T-2902.pdf?sequence=1&amp;isAllowed=y</ext-link>
				</element-citation>
			</ref>
			<ref id="B54">
				<label>[54]</label>
				<mixed-citation>[54] Premier Lab Supply. XRF Sample Preparation Specialists. 2023. <ext-link ext-link-type="uri" xlink:href="https://www.premierlabsupply.com">https://www.premierlabsupply.com</ext-link>
				</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>Premier Lab Supply</collab>
					</person-group>
					<source>XRF Sample Preparation Specialists</source>
					<year>2023</year>
					<ext-link ext-link-type="uri" xlink:href="https://www.premierlabsupply.com">https://www.premierlabsupply.com</ext-link>
				</element-citation>
			</ref>
			<ref id="B55">
				<label>[55]</label>
				<mixed-citation>[55] Malvern Panalytical. Preparación de muestras para análisis XRF e ICP. 2022. <ext-link ext-link-type="uri" xlink:href="https://www.malvernpanalytical.com/es/products/category/sample-preparation-equipment/">https://www.malvernpanalytical.com/es/products/category/sample-preparation-equipment/</ext-link>
				</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>Malvern Panalytical</collab>
					</person-group>
					<source>Preparación de muestras para análisis XRF e ICP</source>
					<year>2022</year>
					<ext-link ext-link-type="uri" xlink:href="https://www.malvernpanalytical.com/es/products/category/sample-preparation-equipment/">https://www.malvernpanalytical.com/es/products/category/sample-preparation-equipment/</ext-link>
				</element-citation>
			</ref>
			<ref id="B56">
				<label>[56]</label>
				<mixed-citation>[56] Sada A. Heavy metals distribution in soil y paddy plants (super): a case study of Kibokwa Basin, Zanzibar. tesis de maestría. The State University of Zanzibar. Zanzibar. 2017. <ext-link ext-link-type="uri" xlink:href="http://repository.suza.ac.tz:8080/bitstream/handle/123456789/163/FINALTHESIS.pdf?sequence=1&amp;isAllowed=y">http://repository.suza.ac.tz:8080/bitstream/handle/123456789/163/FINALTHESIS.pdf?sequence=1&amp;isAllowed=y</ext-link>
				</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>Sada</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<source>Heavy metals distribution in soil y paddy plants (super): a case study of Kibokwa Basin, Zanzibar</source>
					<comment content-type="degree">tesis de maestría</comment>
					<publisher-name>The State University of Zanzibar</publisher-name>
					<publisher-loc>Zanzibar</publisher-loc>
					<year>2017</year>
					<ext-link ext-link-type="uri" xlink:href="http://repository.suza.ac.tz:8080/bitstream/handle/123456789/163/FINALTHESIS.pdf?sequence=1&amp;isAllowed=y">http://repository.suza.ac.tz:8080/bitstream/handle/123456789/163/FINALTHESIS.pdf?sequence=1&amp;isAllowed=y</ext-link>
				</element-citation>
			</ref>
			<ref id="B57">
				<label>[57]</label>
				<mixed-citation>[57] Costa Vinicius C, Amorim FAC, de Babos DV, Pereira Filho ER. Direct determination of Ca, K, Mg, Na, P, S, Fe y Zn in bivalve mollusks by wavelength dispersive X-ray fluorescence (WDXRF) y laser-induced breakdown spectroscopy (LIBS). Food Chemistry. 2019;27391-98. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/J.FOODCHEM.2018.02.016">https://doi.org/10.1016/J.FOODCHEM.2018.02.016</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Costa Vinicius</surname>
							<given-names>C</given-names>
						</name>
						<name>
							<surname>Amorim</surname>
							<given-names>FAC</given-names>
						</name>
						<name>
							<surname>de Babos</surname>
							<given-names>DV</given-names>
						</name>
						<name>
							<surname>Pereira</surname>
							<given-names>ER</given-names>
							<suffix>Filho</suffix>
						</name>
					</person-group>
					<article-title>Direct determination of Ca, K, Mg, Na, P, S, Fe y Zn in bivalve mollusks by wavelength dispersive X-ray fluorescence (WDXRF) y laser-induced breakdown spectroscopy (LIBS)</article-title>
					<source>Food Chemistry</source>
					<year>2019</year>
					<volume>273</volume>
					<fpage>91</fpage>
					<lpage>98</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/J.FOODCHEM.2018.02.016">https://doi.org/10.1016/J.FOODCHEM.2018.02.016</ext-link>
				</element-citation>
			</ref>
			<ref id="B58">
				<label>[58]</label>
				<mixed-citation>[58] Folch E. Determinación de hierro en arroz: aplicación de la Espectroscopía de Fluorescencia de Rayos X (XRF) y Espectrometría de Emisión Atómica (ICP-AES). Invenio. Revista de investigación académica. 2007;1018129-137.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Folch</surname>
							<given-names>E</given-names>
						</name>
					</person-group>
					<article-title>Determinación de hierro en arroz: aplicación de la Espectroscopía de Fluorescencia de Rayos X (XRF) y Espectrometría de Emisión Atómica (ICP-AES)</article-title>
					<source>Invenio. Revista de investigación académica</source>
					<year>2007</year>
					<volume>10</volume>
					<issue>18</issue>
					<fpage>129</fpage>
					<lpage>137</lpage>
				</element-citation>
			</ref>
			<ref id="B59">
				<label>[59]</label>
				<mixed-citation>[59] Beninca C, de Oliveira C, Bet C, Bisinella R, Gaglieri C, Schnitzler E. Effect of ball milling treatment on thermal, structural y morphological properties of phosphated starches from corn y pinhão. Starch. 2020;723. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/STAR.201900233">https://doi.org/10.1002/STAR.201900233</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Beninca</surname>
							<given-names>C</given-names>
						</name>
						<name>
							<surname>de Oliveira</surname>
							<given-names>C</given-names>
						</name>
						<name>
							<surname>Bet</surname>
							<given-names>C</given-names>
						</name>
						<name>
							<surname>Bisinella</surname>
							<given-names>R</given-names>
						</name>
						<name>
							<surname>Gaglieri</surname>
							<given-names>C</given-names>
						</name>
						<name>
							<surname>Schnitzler</surname>
							<given-names>E</given-names>
						</name>
					</person-group>
					<article-title>Effect of ball milling treatment on thermal, structural y morphological properties of phosphated starches from corn y pinhão</article-title>
					<source>Starch</source>
					<year>2020</year>
					<volume>72</volume>
					<issue>3</issue>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/STAR.201900233">https://doi.org/10.1002/STAR.201900233</ext-link>
				</element-citation>
			</ref>
			<ref id="B60">
				<label>[60]</label>
				<mixed-citation>[60] Muhammad A, Tasrina Rabia C, Babul H, Md Panna A. Determination of traces of molybdenum y lead in foods by x-ray fluorescence spectrometry. SpringerPlus. 2014;311-9. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1186/2193-1801-3-341">https://doi.org/10.1186/2193-1801-3-341</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Muhammad</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Tasrina Rabia</surname>
							<given-names>C</given-names>
						</name>
						<name>
							<surname>Babul</surname>
							<given-names>H</given-names>
						</name>
						<name>
							<surname>Md Panna</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<article-title>Determination of traces of molybdenum y lead in foods by x-ray fluorescence spectrometry</article-title>
					<source>SpringerPlus</source>
					<year>2014</year>
					<volume>3</volume>
					<issue>1</issue>
					<fpage>1</fpage>
					<lpage>9</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1186/2193-1801-3-341">https://doi.org/10.1186/2193-1801-3-341</ext-link>
				</element-citation>
			</ref>
			<ref id="B61">
				<label>[61]</label>
				<mixed-citation>[61] Jolly Y, Iqbal S, Rahman M, Kabir J, Akter S, Ahmad I. Energy dispersive X-ray fluorescence detection of heavy metals in Bangladesh cows' milk. Heliyon. 2017;391-22. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/J.HELIYON.2017.E00403">https://doi.org/10.1016/J.HELIYON.2017.E00403</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Jolly</surname>
							<given-names>Y</given-names>
						</name>
						<name>
							<surname>Iqbal</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Rahman</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Kabir</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Akter</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Ahmad</surname>
							<given-names>I</given-names>
						</name>
					</person-group>
					<article-title>Energy dispersive X-ray fluorescence detection of heavy metals in Bangladesh cows' milk</article-title>
					<source>Heliyon</source>
					<year>2017</year>
					<volume>3</volume>
					<issue>9</issue>
					<fpage>1</fpage>
					<lpage>22</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/J.HELIYON.2017.E00403">https://doi.org/10.1016/J.HELIYON.2017.E00403</ext-link>
				</element-citation>
			</ref>
			<ref id="B62">
				<label>[62]</label>
				<mixed-citation>[62] Chubarov V, Pashkova G, Panteeva S, Amosova A. Multielement analysis of continental y lacustrine ferromanganese nodules by WDXRF, TXRF y ICP-MS methods. Intercomparison study y accuracy assessment. Applied Radiation y Isotopes. 2021;1781099811-8. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.apradiso.2021.109981">https://doi.org/10.1016/j.apradiso.2021.109981</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Chubarov</surname>
							<given-names>V</given-names>
						</name>
						<name>
							<surname>Pashkova</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>Panteeva</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Amosova</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<article-title>Multielement analysis of continental y lacustrine ferromanganese nodules by WDXRF, TXRF y ICP-MS methods. Intercomparison study y accuracy assessment</article-title>
					<source>Applied Radiation y Isotopes</source>
					<year>2021</year>
					<volume>178</volume>
					<issue>109981</issue>
					<fpage>1</fpage>
					<lpage>8</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.apradiso.2021.109981">https://doi.org/10.1016/j.apradiso.2021.109981</ext-link>
				</element-citation>
			</ref>
			<ref id="B63">
				<label>[63]</label>
				<mixed-citation>[63] Morikawa A. Sample preparation for X-ray fluorescence analysis II. Pulverizing methods of powder samples. Rigaku Journal. 2014;30223-27.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Morikawa</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<article-title>Sample preparation for X-ray fluorescence analysis II. Pulverizing methods of powder samples</article-title>
					<source>Rigaku Journal</source>
					<year>2014</year>
					<volume>30</volume>
					<issue>2</issue>
					<fpage>23</fpage>
					<lpage>27</lpage>
				</element-citation>
			</ref>
			<ref id="B64">
				<label>[64]</label>
				<mixed-citation>[64] Nakayama K, Nakamura T. X-Ray Fluorescence Spectroscopy for Geochemistry. Treatise on Geochemistry. 2nd ed. Elsevier Ltd.. 2013;15181-194. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/B978-0-08-095975-7.01413-3">https://doi.org/10.1016/B978-0-08-095975-7.01413-3</ext-link>
				</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Nakayama</surname>
							<given-names>K</given-names>
						</name>
						<name>
							<surname>Nakamura</surname>
							<given-names>T</given-names>
						</name>
					</person-group>
					<chapter-title>X-Ray Fluorescence Spectroscopy for Geochemistry</chapter-title>
					<source>Treatise on Geochemistry</source>
					<edition>2nd ed</edition>
					<publisher-name>Elsevier Ltd.</publisher-name>
					<year>2013</year>
					<volume>15</volume>
					<fpage>181</fpage>
					<lpage>194</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/B978-0-08-095975-7.01413-3">https://doi.org/10.1016/B978-0-08-095975-7.01413-3</ext-link>
				</element-citation>
			</ref>
			<ref id="B65">
				<label>[65]</label>
				<mixed-citation>[65] Masson P, Gallet A, Guezenoc J. LIBS y XRF: dos técnicas para una medición rápida de los elementos nutritivos en los suelos. Technical Reviews. 2020. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.20870/ives-tr.2020.4518">https://doi.org/10.20870/ives-tr.2020.4518</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Masson</surname>
							<given-names>P</given-names>
						</name>
						<name>
							<surname>Gallet</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Guezenoc</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<article-title>LIBS y XRF: dos técnicas para una medición rápida de los elementos nutritivos en los suelos</article-title>
					<source>Technical Reviews</source>
					<year>2020</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.20870/ives-tr.2020.4518">https://doi.org/10.20870/ives-tr.2020.4518</ext-link>
				</element-citation>
			</ref>
			<ref id="B66">
				<label>[66]</label>
				<mixed-citation>[66] Christopher, S. et al. Certificate of Analysis Analytical Standard Reference Material® 1568b Rice Flour. 2021. Gaithersburg.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>Christopher, S. et al</collab>
					</person-group>
					<source>Certificate of Analysis Analytical Standard Reference Material® 1568b Rice Flour</source>
					<year>2021</year>
					<publisher-loc>Gaithersburg</publisher-loc>
				</element-citation>
			</ref>
			<ref id="B67">
				<label>[67]</label>
				<mixed-citation>[67] Christopher, S. et al. Certificate of Analysis Analytical Standard Reference Material® 1567b Wheat Flour. 2014. Gaithersburg.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>Christopher, S. et al</collab>
					</person-group>
					<source>Certificate of Analysis Analytical Standard Reference Material® 1567b Wheat Flour</source>
					<year>2014</year>
					<publisher-loc>Gaithersburg</publisher-loc>
				</element-citation>
			</ref>
			<ref id="B68">
				<label>[68]</label>
				<mixed-citation>[68] Kulal C, Padhi R, Venkatraj K, Satpathy K, Mallaya S. Study on Trace Elements Concentration in Medicinal Plants Using EDXRF Technique. Biological Trace Element Research. 2020;1981293-302. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s12011-020-02037-7">https://doi.org/10.1007/s12011-020-02037-7</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Kulal</surname>
							<given-names>C</given-names>
						</name>
						<name>
							<surname>Padhi</surname>
							<given-names>R</given-names>
						</name>
						<name>
							<surname>Venkatraj</surname>
							<given-names>K</given-names>
						</name>
						<name>
							<surname>Satpathy</surname>
							<given-names>K</given-names>
						</name>
						<name>
							<surname>Mallaya</surname>
							<given-names>S</given-names>
						</name>
					</person-group>
					<article-title>Study on Trace Elements Concentration in Medicinal Plants Using EDXRF Technique</article-title>
					<source>Biological Trace Element Research</source>
					<year>2020</year>
					<volume>198</volume>
					<issue>1</issue>
					<fpage>293</fpage>
					<lpage>302</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s12011-020-02037-7">https://doi.org/10.1007/s12011-020-02037-7</ext-link>
				</element-citation>
			</ref>
			<ref id="B69">
				<label>[69]</label>
				<mixed-citation>[69] Chitkara M, Kohli R, Sandhu I, Singh D, Kaur G, Sindhu R. Mineral content analysis of polyherbal energy bar using X-ray fluorescence technique. Pharmacognosy Journal. 2019;11153-56. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.5530/pj.2019.L10">https://doi.org/10.5530/pj.2019.L10</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Chitkara</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Kohli</surname>
							<given-names>R</given-names>
						</name>
						<name>
							<surname>Sandhu</surname>
							<given-names>I</given-names>
						</name>
						<name>
							<surname>Singh</surname>
							<given-names>D</given-names>
						</name>
						<name>
							<surname>Kaur</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>Sindhu</surname>
							<given-names>R</given-names>
						</name>
					</person-group>
					<article-title>Mineral content analysis of polyherbal energy bar using X-ray fluorescence technique</article-title>
					<source>Pharmacognosy Journal</source>
					<year>2019</year>
					<volume>11</volume>
					<issue>1</issue>
					<fpage>53</fpage>
					<lpage>56</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.5530/pj.2019.L10">https://doi.org/10.5530/pj.2019.L10</ext-link>
				</element-citation>
			</ref>
			<ref id="B70">
				<label>[70]</label>
				<mixed-citation>[70] INTECO. Análisis químico del cemento por Fluorescencia de Rayos X. Método de ensayo. Costa Rica. 2019;1-18.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>INTECO</collab>
					</person-group>
					<source>Análisis químico del cemento por Fluorescencia de Rayos X. Método de ensayo</source>
					<publisher-loc>Costa Rica</publisher-loc>
					<year>2019</year>
					<fpage>1</fpage>
					<lpage>18</lpage>
				</element-citation>
			</ref>
			<ref id="B71">
				<label>[71]</label>
				<mixed-citation>[71] Venegas P. Evaluación del contenido de cromo, plomo y mercurio en cementos hidráulicos de uso general comercializados en Costa Rica. tesis de grado. Universidad Nacional - Campus Omar Dengo. Heredia. 2016. <ext-link ext-link-type="uri" xlink:href="https://repositorio.una.ac.cr/handle/11056/26436">https://repositorio.una.ac.cr/handle/11056/26436</ext-link>
				</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>Venegas</surname>
							<given-names>P</given-names>
						</name>
					</person-group>
					<source>Evaluación del contenido de cromo, plomo y mercurio en cementos hidráulicos de uso general comercializados en Costa Rica</source>
					<comment content-type="degree">tesis de grado</comment>
					<publisher-name>Universidad Nacional - Campus Omar Dengo</publisher-name>
					<publisher-loc>Heredia</publisher-loc>
					<year>2016</year>
					<ext-link ext-link-type="uri" xlink:href="https://repositorio.una.ac.cr/handle/11056/26436">https://repositorio.una.ac.cr/handle/11056/26436</ext-link>
				</element-citation>
			</ref>
			<ref id="B72">
				<label>[72]</label>
				<mixed-citation>[72] Shibata Y, Suyama J, Kitano M, Nakamura T. X-ray fluorescence analysis of Cr, As, Se, Cd, Hg y Pb in soil using pressed powder pellet y loose powder methods. X-Ray Spectrometry. 2009;385410-416. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/xrs.1195">https://doi.org/10.1002/xrs.1195</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Shibata</surname>
							<given-names>Y</given-names>
						</name>
						<name>
							<surname>Suyama</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Kitano</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Nakamura</surname>
							<given-names>T</given-names>
						</name>
					</person-group>
					<article-title>X-ray fluorescence analysis of Cr, As, Se, Cd, Hg y Pb in soil using pressed powder pellet y loose powder methods</article-title>
					<source>X-Ray Spectrometry</source>
					<year>2009</year>
					<volume>38</volume>
					<issue>5</issue>
					<fpage>410</fpage>
					<lpage>416</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/xrs.1195">https://doi.org/10.1002/xrs.1195</ext-link>
				</element-citation>
			</ref>
			<ref id="B73">
				<label>[73]</label>
				<mixed-citation>[73] Ichikawa S, Nakayama K, Nakamura T. Loose-powder technique for X-ray fluorescence analysis of ancient pottery using a small (100 mg) powdered sample. X-Ray Spectrometry. 2012;415288-297. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/xrs.2394">https://doi.org/10.1002/xrs.2394</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Ichikawa</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Nakayama</surname>
							<given-names>K</given-names>
						</name>
						<name>
							<surname>Nakamura</surname>
							<given-names>T</given-names>
						</name>
					</person-group>
					<article-title>Loose-powder technique for X-ray fluorescence analysis of ancient pottery using a small (100 mg) powdered sample</article-title>
					<source>X-Ray Spectrometry</source>
					<year>2012</year>
					<volume>41</volume>
					<issue>5</issue>
					<fpage>288</fpage>
					<lpage>297</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/xrs.2394">https://doi.org/10.1002/xrs.2394</ext-link>
				</element-citation>
			</ref>
			<ref id="B74">
				<label>[74]</label>
				<mixed-citation>[74] Inui T, Koike Y, Nakamura T. Preparation of cadmium-containing brown rice grains as calibration standards for X-ray fluorescence analysis of cadmium in rice grains. X-Ray Spectrometry. 2014;432112-117. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/xrs.2524">https://doi.org/10.1002/xrs.2524</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Inui</surname>
							<given-names>T</given-names>
						</name>
						<name>
							<surname>Koike</surname>
							<given-names>Y</given-names>
						</name>
						<name>
							<surname>Nakamura</surname>
							<given-names>T</given-names>
						</name>
					</person-group>
					<article-title>Preparation of cadmium-containing brown rice grains as calibration standards for X-ray fluorescence analysis of cadmium in rice grains</article-title>
					<source>X-Ray Spectrometry</source>
					<year>2014</year>
					<volume>43</volume>
					<issue>2</issue>
					<fpage>112</fpage>
					<lpage>117</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/xrs.2524">https://doi.org/10.1002/xrs.2524</ext-link>
				</element-citation>
			</ref>
			<ref id="B75">
				<label>[75]</label>
				<mixed-citation>[75] Mohammad A-E, Ahmed K. Elemental analysis of steel products using X-ray fluorescence (XRF) technique. Journal of King Saud University - Engineering Sciences. 2011;23275-79. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jksues.2011.03.002">https://doi.org/10.1016/j.jksues.2011.03.002</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Mohammad</surname>
							<given-names>A-E</given-names>
						</name>
						<name>
							<surname>Ahmed</surname>
							<given-names>K</given-names>
						</name>
					</person-group>
					<article-title>Elemental analysis of steel products using X-ray fluorescence (XRF) technique</article-title>
					<source>Journal of King Saud University - Engineering Sciences</source>
					<year>2011</year>
					<volume>23</volume>
					<issue>2</issue>
					<fpage>75</fpage>
					<lpage>79</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jksues.2011.03.002">https://doi.org/10.1016/j.jksues.2011.03.002</ext-link>
				</element-citation>
			</ref>
			<ref id="B76">
				<label>[76]</label>
				<mixed-citation>[76] Japanese Industrial Standards. Iron y steel -- Method for X-ray fluorescence spectrometric analysis. Japón. 2013. <ext-link ext-link-type="uri" xlink:href="https://www.antpedia.com/standard/sp/en/11312.html">https://www.antpedia.com/standard/sp/en/11312.html</ext-link>
				</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>Japanese Industrial Standards</collab>
					</person-group>
					<source>Iron y steel -- Method for X-ray fluorescence spectrometric analysis</source>
					<publisher-loc>Japón</publisher-loc>
					<year>2013</year>
					<ext-link ext-link-type="uri" xlink:href="https://www.antpedia.com/standard/sp/en/11312.html">https://www.antpedia.com/standard/sp/en/11312.html</ext-link>
				</element-citation>
			</ref>
			<ref id="B77">
				<label>[77]</label>
				<mixed-citation>[77] Japanese Industrial Standards. Copper alloys -- Methods for X-ray fluorescence spectrometric analysis. Japón. 2018. <ext-link ext-link-type="uri" xlink:href="https://www.antpedia.com/standard/sp/en/11312.html">https://www.antpedia.com/standard/sp/en/11312.html</ext-link>
				</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>Japanese Industrial Standards</collab>
					</person-group>
					<source>Copper alloys -- Methods for X-ray fluorescence spectrometric analysis</source>
					<publisher-loc>Japón</publisher-loc>
					<year>2018</year>
					<ext-link ext-link-type="uri" xlink:href="https://www.antpedia.com/standard/sp/en/11312.html">https://www.antpedia.com/standard/sp/en/11312.html</ext-link>
				</element-citation>
			</ref>
			<ref id="B78">
				<label>[78]</label>
				<mixed-citation>[78] Fujimori T, Takigami H. Pollution distribution of heavy metals in surface soil at an informal electronic-waste recycling site. Environmental Geochemistry y Health. 2014;361159-168. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s10653-013-9526-y">https://doi.org/10.1007/s10653-013-9526-y</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Fujimori</surname>
							<given-names>T</given-names>
						</name>
						<name>
							<surname>Takigami</surname>
							<given-names>H</given-names>
						</name>
					</person-group>
					<article-title>Pollution distribution of heavy metals in surface soil at an informal electronic-waste recycling site</article-title>
					<source>Environmental Geochemistry y Health</source>
					<year>2014</year>
					<volume>36</volume>
					<issue>1</issue>
					<fpage>159</fpage>
					<lpage>168</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s10653-013-9526-y">https://doi.org/10.1007/s10653-013-9526-y</ext-link>
				</element-citation>
			</ref>
			<ref id="B79">
				<label>[79]</label>
				<mixed-citation>[79] Van, M. et al. Study on RoHS y WEEE Directives. European Commission DG Enterprise and Industry. 2008.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>Van, M. et al</collab>
					</person-group>
					<source>Study on RoHS y WEEE Directives</source>
					<publisher-name>European Commission DG Enterprise and Industry</publisher-name>
					<year>2008</year>
				</element-citation>
			</ref>
			<ref id="B80">
				<label>[80]</label>
				<mixed-citation>[80] Hutton L, O'Neil G, Read T, Ayres Z, Newton M, MacPherson J. Electrochemical X-ray fluorescence spectroscopy for trace heavy metal analysis: Enhancing X-ray fluorescence detection capabilities by four orders of magnitude. Analytical Chemistry. 2014;8694566-4572. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1021/ac500608d">https://doi.org/10.1021/ac500608d</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Hutton</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>O'Neil</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>Read</surname>
							<given-names>T</given-names>
						</name>
						<name>
							<surname>Ayres</surname>
							<given-names>Z</given-names>
						</name>
						<name>
							<surname>Newton</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>MacPherson</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<article-title>Electrochemical X-ray fluorescence spectroscopy for trace heavy metal analysis: Enhancing X-ray fluorescence detection capabilities by four orders of magnitude</article-title>
					<source>Analytical Chemistry</source>
					<year>2014</year>
					<volume>86</volume>
					<issue>9</issue>
					<fpage>4566</fpage>
					<lpage>4572</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1021/ac500608d">https://doi.org/10.1021/ac500608d</ext-link>
				</element-citation>
			</ref>
			<ref id="B91">
				<label>[91]</label>
				<mixed-citation>[91] Mino Y. Determination of tin in canned foods by X-ray fluorescence spectrometry. Journal of Health Science. 2006;52167-72. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1248/jhs.52.67">https://doi.org/10.1248/jhs.52.67</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Mino</surname>
							<given-names>Y</given-names>
						</name>
					</person-group>
					<article-title>Determination of tin in canned foods by X-ray fluorescence spectrometry</article-title>
					<source>Journal of Health Science</source>
					<year>2006</year>
					<volume>52</volume>
					<issue>1</issue>
					<fpage>67</fpage>
					<lpage>72</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1248/jhs.52.67">https://doi.org/10.1248/jhs.52.67</ext-link>
				</element-citation>
			</ref>
			<ref id="B92">
				<label>[92]</label>
				<mixed-citation>[92] Takahashi G. Sample preparation for X-ray fluorescence analysis III. Pressed y loose powder methods. Rigaku Journal. 2015;31126-30.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Takahashi</surname>
							<given-names>G</given-names>
						</name>
					</person-group>
					<article-title>Sample preparation for X-ray fluorescence analysis III. Pressed y loose powder methods</article-title>
					<source>Rigaku Journal</source>
					<year>2015</year>
					<volume>31</volume>
					<issue>1</issue>
					<fpage>26</fpage>
					<lpage>30</lpage>
				</element-citation>
			</ref>
			<ref id="B93">
				<label>[93]</label>
				<mixed-citation>[93] Younis A, Ahmadi Z, Adams M, Iqbal A. A simple method for quantitative analysis of elements by WD-XRF using variable dilution factors in fusion bead technique for geologic specimens. X-Ray Spectrometry. 2017;46169-76. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/xrs.2729">https://doi.org/10.1002/xrs.2729</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Younis</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Ahmadi</surname>
							<given-names>Z</given-names>
						</name>
						<name>
							<surname>Adams</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Iqbal</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<article-title>A simple method for quantitative analysis of elements by WD-XRF using variable dilution factors in fusion bead technique for geologic specimens</article-title>
					<source>X-Ray Spectrometry</source>
					<year>2017</year>
					<volume>46</volume>
					<issue>1</issue>
					<fpage>69</fpage>
					<lpage>76</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/xrs.2729">https://doi.org/10.1002/xrs.2729</ext-link>
				</element-citation>
			</ref>
			<ref id="B94">
				<label>[94]</label>
				<mixed-citation>[94] A. Bell <italic>et al</italic>., “X-ray fluorescence analysis of feldspars y silicate glass: Effects of melting time on fused bead consistency y volatilisation”, <italic>Minerals</italic>, vol. 10, nro. 5, pp. 442-459, 2020. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/min10050442">https://doi.org/10.3390/min10050442</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Bell</surname>
							<given-names>A.</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>X-ray fluorescence analysis of feldspars y silicate glass: Effects of melting time on fused bead consistency y volatilisation</article-title>
					<source>Minerals</source>
					<volume>10</volume>
					<issue>5</issue>
					<fpage>442</fpage>
					<lpage>459</lpage>
					<year>2020</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/min10050442">https://doi.org/10.3390/min10050442</ext-link>
				</element-citation>
			</ref>
			<ref id="B95">
				<label>[95]</label>
				<mixed-citation>[95] Rohiman A, Arifin AS. Comparation of Pressed Powder Pellet y Fused Glass Bead Preparation Techniques for Mayor Elements Analysis of Rock Samples using X-Ray Fluorescence (XRF). Indonesian Journal of Physics. 2020;31224-27. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.5614/itb.ijp.2020.31.2.4">https://doi.org/10.5614/itb.ijp.2020.31.2.4</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Rohiman</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Arifin</surname>
							<given-names>AS</given-names>
						</name>
					</person-group>
					<article-title>Comparation of Pressed Powder Pellet y Fused Glass Bead Preparation Techniques for Mayor Elements Analysis of Rock Samples using X-Ray Fluorescence (XRF)</article-title>
					<source>Indonesian Journal of Physics</source>
					<year>2020</year>
					<volume>31</volume>
					<issue>2</issue>
					<fpage>24</fpage>
					<lpage>27</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.5614/itb.ijp.2020.31.2.4">https://doi.org/10.5614/itb.ijp.2020.31.2.4</ext-link>
				</element-citation>
			</ref>
			<ref id="B96">
				<label>[96]</label>
				<mixed-citation>[96] Ramsey M, Potts P, Webb P, Watkins P, Watson J, Coles B. An objective assessment of analytical method precision: comparison of ICP-AES y XRF for the analysis of silicate rocks. Chemical Geology. 1995;1241-19. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/0009-2541(95)00020-M">https://doi.org/10.1016/0009-2541(95)00020-M</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Ramsey</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Potts</surname>
							<given-names>P</given-names>
						</name>
						<name>
							<surname>Webb</surname>
							<given-names>P</given-names>
						</name>
						<name>
							<surname>Watkins</surname>
							<given-names>P</given-names>
						</name>
						<name>
							<surname>Watson</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Coles</surname>
							<given-names>B</given-names>
						</name>
					</person-group>
					<article-title>An objective assessment of analytical method precision: comparison of ICP-AES y XRF for the analysis of silicate rocks</article-title>
					<source>Chemical Geology</source>
					<year>1995</year>
					<volume>124</volume>
					<fpage>1</fpage>
					<lpage>19</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/0009-2541(95)00020-M">https://doi.org/10.1016/0009-2541(95)00020-M</ext-link>
				</element-citation>
			</ref>
			<ref id="B97">
				<label>[97]</label>
				<mixed-citation>[97] Busatlic I, Haracic N, Merdic N. XRF Spectrometer sample preparation by using fused beads technique. 2009. <ext-link ext-link-type="uri" xlink:href="https://www.researchgate.net/publication/316253039">https://www.researchgate.net/publication/316253039</ext-link>
				</mixed-citation>
				<element-citation publication-type="webpage">
					<person-group person-group-type="author">
						<name>
							<surname>Busatlic</surname>
							<given-names>I</given-names>
						</name>
						<name>
							<surname>Haracic</surname>
							<given-names>N</given-names>
						</name>
						<name>
							<surname>Merdic</surname>
							<given-names>N</given-names>
						</name>
					</person-group>
					<source>XRF Spectrometer sample preparation by using fused beads technique</source>
					<year>2009</year>
					<ext-link ext-link-type="uri" xlink:href="https://www.researchgate.net/publication/316253039">https://www.researchgate.net/publication/316253039</ext-link>
				</element-citation>
			</ref>
			<ref id="B98">
				<label>[98]</label>
				<mixed-citation>[98] Watanabe M. Sample preparation for X-ray fluorescence analysis IV. Fusion bead method part 1 basic principals. Rigaku Journal. 2015;31212-17.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Watanabe</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<article-title>Sample preparation for X-ray fluorescence analysis IV. Fusion bead method part 1 basic principals</article-title>
					<source>Rigaku Journal</source>
					<year>2015</year>
					<volume>31</volume>
					<issue>2</issue>
					<fpage>12</fpage>
					<lpage>17</lpage>
				</element-citation>
			</ref>
			<ref id="B99">
				<label>[99]</label>
				<mixed-citation>[99] Yamasaki T. XRF major element analyses of silicate rocks using 1:10 dilution ratio glass bead y a synthetically extended calibration curve method. Bulletin of the Geological Survey of Japan. 2014;657-897-103. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.9795/bullgsj.65.97">https://doi.org/10.9795/bullgsj.65.97</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Yamasaki</surname>
							<given-names>T</given-names>
						</name>
					</person-group>
					<article-title>XRF major element analyses of silicate rocks using 1:10 dilution ratio glass bead y a synthetically extended calibration curve method</article-title>
					<source>Bulletin of the Geological Survey of Japan</source>
					<year>2014</year>
					<volume>65</volume>
					<issue>7-8</issue>
					<fpage>97</fpage>
					<lpage>103</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.9795/bullgsj.65.97">https://doi.org/10.9795/bullgsj.65.97</ext-link>
				</element-citation>
			</ref>
			<ref id="B100">
				<label>[100]</label>
				<mixed-citation>[100] Yamasaki T, Yamashita K. Whole rock multiple trace element analyses using fused glass bead by laser ablation-ICP-MS. Bulletin of the Geological Survey of Japan. 2016;67127-40. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.9795/bullgsj.67.27">https://doi.org/10.9795/bullgsj.67.27</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Yamasaki</surname>
							<given-names>T</given-names>
						</name>
						<name>
							<surname>Yamashita</surname>
							<given-names>K</given-names>
						</name>
					</person-group>
					<article-title>Whole rock multiple trace element analyses using fused glass bead by laser ablation-ICP-MS</article-title>
					<source>Bulletin of the Geological Survey of Japan</source>
					<year>2016</year>
					<volume>67</volume>
					<issue>1</issue>
					<fpage>27</fpage>
					<lpage>40</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.9795/bullgsj.67.27">https://doi.org/10.9795/bullgsj.67.27</ext-link>
				</element-citation>
			</ref>
			<ref id="B101">
				<label>[101]</label>
				<mixed-citation>[101] Watanabe M. Sample preparation for X-ray fluorescence analysis V. Fusion bead method-part 2: practical applications. Rigaku Journal. 2016;32117-21.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Watanabe</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<article-title>Sample preparation for X-ray fluorescence analysis V. Fusion bead method-part 2: practical applications</article-title>
					<source>Rigaku Journal</source>
					<year>2016</year>
					<volume>32</volume>
					<issue>1</issue>
					<fpage>17</fpage>
					<lpage>21</lpage>
				</element-citation>
			</ref>
			<ref id="B102">
				<label>[102]</label>
				<mixed-citation>[102] Liu H, Lu C, Zhou Z, Huang F, Hu X. Specimen variation effects on XRF analysis by the Monte Carlo method: thicknesses, densities y particle sizes. Journal of Applied Mathematics y Physics. 2018;64628-639. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.4236/jamp.2018.64055">https://doi.org/10.4236/jamp.2018.64055</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Liu</surname>
							<given-names>H</given-names>
						</name>
						<name>
							<surname>Lu</surname>
							<given-names>C</given-names>
						</name>
						<name>
							<surname>Zhou</surname>
							<given-names>Z</given-names>
						</name>
						<name>
							<surname>Huang</surname>
							<given-names>F</given-names>
						</name>
						<name>
							<surname>Hu</surname>
							<given-names>X</given-names>
						</name>
					</person-group>
					<article-title>Specimen variation effects on XRF analysis by the Monte Carlo method: thicknesses, densities y particle sizes</article-title>
					<source>Journal of Applied Mathematics y Physics</source>
					<year>2018</year>
					<volume>6</volume>
					<issue>4</issue>
					<fpage>628</fpage>
					<lpage>639</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.4236/jamp.2018.64055">https://doi.org/10.4236/jamp.2018.64055</ext-link>
				</element-citation>
			</ref>
			<ref id="B103">
				<label>[103]</label>
				<mixed-citation>[103] Sitko R, Zawisza B. Quantification in X-Ray Fluorescence Spectrometry. X-Ray Spectroscopy. Print edition. Polonia. 2012;137-162.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Sitko</surname>
							<given-names>R</given-names>
						</name>
						<name>
							<surname>Zawisza</surname>
							<given-names>B</given-names>
						</name>
					</person-group>
					<chapter-title>Quantification in X-Ray Fluorescence Spectrometry</chapter-title>
					<source>X-Ray Spectroscopy</source>
					<publisher-name>Print edition</publisher-name>
					<publisher-loc>Polonia</publisher-loc>
					<year>2012</year>
					<fpage>137</fpage>
					<lpage>162</lpage>
				</element-citation>
			</ref>
			<ref id="B104">
				<label>[104]</label>
				<mixed-citation>[104] Bazaes A. Comparación de corrección teórica de efecto matriz, análisis de interferencias y corrección por compensación para equipos portátiles de fluorescencia de rayos X en minerales y suelos. tesis de grado. Universidad de Chile. Santiago de Chile. 2013. <ext-link ext-link-type="uri" xlink:href="https://repositorio.uchile.cl/handle/2250/115141">https://repositorio.uchile.cl/handle/2250/115141</ext-link>
				</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>Bazaes</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<source>Comparación de corrección teórica de efecto matriz, análisis de interferencias y corrección por compensación para equipos portátiles de fluorescencia de rayos X en minerales y suelos</source>
					<comment content-type="degree">tesis de grado</comment>
					<publisher-name>Universidad de Chile</publisher-name>
					<publisher-loc>Santiago de Chile</publisher-loc>
					<year>2013</year>
					<ext-link ext-link-type="uri" xlink:href="https://repositorio.uchile.cl/handle/2250/115141">https://repositorio.uchile.cl/handle/2250/115141</ext-link>
				</element-citation>
			</ref>
			<ref id="B105">
				<label>[105]</label>
				<mixed-citation>[105] Melara O. Determinación de contaminación por metales pesados nefrotóxicos, mediante Fluorescencia de Rayos X, en suelos de áreas rurales del municipio de San Luis Talpa, El Salvador. tesis de grado. Universidad de El Salvador. San Salvador. 2016. <ext-link ext-link-type="uri" xlink:href="http://ri.ues.edu.sv/id/eprint/12789/1/19201049.pdf">http://ri.ues.edu.sv/id/eprint/12789/1/19201049.pdf</ext-link>
				</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>Melara</surname>
							<given-names>O</given-names>
						</name>
					</person-group>
					<source>Determinación de contaminación por metales pesados nefrotóxicos, mediante Fluorescencia de Rayos X, en suelos de áreas rurales del municipio de San Luis Talpa, El Salvador</source>
					<comment content-type="degree">tesis de grado</comment>
					<publisher-name>Universidad de El Salvador</publisher-name>
					<publisher-loc>San Salvador</publisher-loc>
					<year>2016</year>
					<ext-link ext-link-type="uri" xlink:href="http://ri.ues.edu.sv/id/eprint/12789/1/19201049.pdf">http://ri.ues.edu.sv/id/eprint/12789/1/19201049.pdf</ext-link>
				</element-citation>
			</ref>
			<ref id="B106">
				<label>[106]</label>
				<mixed-citation>[106] Rousseau R. Corrections for matrix effects in X-ray fluorescence analysis-A tutorial. Spectrochimica Acta Part B. 2006;617759-777. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.sab.2006.06.014">https://doi.org/10.1016/j.sab.2006.06.014</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Rousseau</surname>
							<given-names>R</given-names>
						</name>
					</person-group>
					<article-title>Corrections for matrix effects in X-ray fluorescence analysis-A tutorial</article-title>
					<source>Spectrochimica Acta Part B</source>
					<year>2006</year>
					<volume>61</volume>
					<issue>7</issue>
					<fpage>759</fpage>
					<lpage>777</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.sab.2006.06.014">https://doi.org/10.1016/j.sab.2006.06.014</ext-link>
				</element-citation>
			</ref>
			<ref id="B107">
				<label>[107]</label>
				<mixed-citation>[107] Takahara H. Thickness y composition analysis of thin film samples using FP method by XRF analysis. Rigaku Journal. 2017;33217-21.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Takahara</surname>
							<given-names>H</given-names>
						</name>
					</person-group>
					<article-title>Thickness y composition analysis of thin film samples using FP method by XRF analysis</article-title>
					<source>Rigaku Journal</source>
					<year>2017</year>
					<volume>33</volume>
					<issue>2</issue>
					<fpage>17</fpage>
					<lpage>21</lpage>
				</element-citation>
			</ref>
			<ref id="B108">
				<label>[108]</label>
				<mixed-citation>[108] Thomsen V. Basic Fundamental Parameters in X-Ray Fluorescence. 2007. <ext-link ext-link-type="uri" xlink:href="https://www.spectroscopyonline.com/view/basic-fundamental-parameters-x-ray-fluorescence">https://www.spectroscopyonline.com/view/basic-fundamental-parameters-x-ray-fluorescence</ext-link>
				</mixed-citation>
				<element-citation publication-type="webpage">
					<person-group person-group-type="author">
						<name>
							<surname>Thomsen</surname>
							<given-names>V</given-names>
						</name>
					</person-group>
					<source>Basic Fundamental Parameters in X-Ray Fluorescence</source>
					<year>2007</year>
					<ext-link ext-link-type="uri" xlink:href="https://www.spectroscopyonline.com/view/basic-fundamental-parameters-x-ray-fluorescence">https://www.spectroscopyonline.com/view/basic-fundamental-parameters-x-ray-fluorescence</ext-link>
				</element-citation>
			</ref>
			<ref id="B109">
				<label>[109]</label>
				<mixed-citation>[109] Rousseau R. Concept of the influence coefficient. The Rigaku Journal. 2001;1818-21. <ext-link ext-link-type="uri" xlink:href="https://www.researchgate.net/publication/313180256">https://www.researchgate.net/publication/313180256</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Rousseau</surname>
							<given-names>R</given-names>
						</name>
					</person-group>
					<article-title>Concept of the influence coefficient</article-title>
					<source>The Rigaku Journal</source>
					<year>2001</year>
					<volume>18</volume>
					<issue>1</issue>
					<fpage>8</fpage>
					<lpage>21</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://www.researchgate.net/publication/313180256">https://www.researchgate.net/publication/313180256</ext-link>
				</element-citation>
			</ref>
			<ref id="B110">
				<label>[110]</label>
				<mixed-citation>[110] Ichikawa S, Nakamura T. Approaches to solid sample preparation based on analytical depth for reliable X-ray fluorescence analysis. X-Ray Spectrometry. 2016;456302-307. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/xrs.2700">https://doi.org/10.1002/xrs.2700</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Ichikawa</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Nakamura</surname>
							<given-names>T</given-names>
						</name>
					</person-group>
					<article-title>Approaches to solid sample preparation based on analytical depth for reliable X-ray fluorescence analysis</article-title>
					<source>X-Ray Spectrometry</source>
					<year>2016</year>
					<volume>45</volume>
					<issue>6</issue>
					<fpage>302</fpage>
					<lpage>307</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1002/xrs.2700">https://doi.org/10.1002/xrs.2700</ext-link>
				</element-citation>
			</ref>
			<ref id="B111">
				<label>[111]</label>
				<mixed-citation>[111] Oficina Internacional de Pesas y Medidas (BIPM) et al. Vocabulario Internacional de Metrología: Conceptos fundamentales y generales y términos asociados (VIM). 3rd ed. 2012;1.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>Oficina Internacional de Pesas y Medidas (BIPM) et al</collab>
					</person-group>
					<source>Vocabulario Internacional de Metrología: Conceptos fundamentales y generales y términos asociados (VIM)</source>
					<edition>3rd ed</edition>
					<year>2012</year>
					<volume>1</volume>
				</element-citation>
			</ref>
			<ref id="B112">
				<label>[112]</label>
				<mixed-citation>[112] Organización Mundial de la Salud (OMS). Guía breve de los métodos analíticos para determinar el contenido de plomo de la pintura. 2nd ed. Ginebra. 2020;2.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>Organización Mundial de la Salud (OMS)</collab>
					</person-group>
					<source>Guía breve de los métodos analíticos para determinar el contenido de plomo de la pintura</source>
					<edition>2nd ed</edition>
					<publisher-loc>Ginebra</publisher-loc>
					<year>2020</year>
					<volume>2</volume>
				</element-citation>
			</ref>
			<ref id="B113">
				<label>[113]</label>
				<mixed-citation>[113] Guangxi W, et al. Determination y analysis of mineral elements content in rice samples. Nuclear Techniques. 2017;4081-6. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.11889/J.0253-3219.2017.HJS.40.080501">https://doi.org/10.11889/J.0253-3219.2017.HJS.40.080501</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Guangxi</surname>
							<given-names>W</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>Determination y analysis of mineral elements content in rice samples</article-title>
					<source>Nuclear Techniques</source>
					<year>2017</year>
					<volume>40</volume>
					<issue>8</issue>
					<fpage>1</fpage>
					<lpage>6</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.11889/J.0253-3219.2017.HJS.40.080501">https://doi.org/10.11889/J.0253-3219.2017.HJS.40.080501</ext-link>
				</element-citation>
			</ref>
			<ref id="B114">
				<label>[114]</label>
				<mixed-citation>[114] Barwick V, et al. The fitness for purpose of analytical methods: a laboratory guide to method validation y related topics. Eurolab España. 2014;2.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Barwick</surname>
							<given-names>V</given-names>
						</name>
						<etal/>
					</person-group>
					<source>The fitness for purpose of analytical methods: a laboratory guide to method validation y related topics</source>
					<publisher-name>Eurolab España</publisher-name>
					<year>2014</year>
					<volume>2</volume>
				</element-citation>
			</ref>
			<ref id="B115">
				<label>[115]</label>
				<mixed-citation>[115] Ahumada D, Paredes C, Abella J, González I. Guía de validación de métodos en análisis químico cuantitativo. INM. Bogotá. 2023;1.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Ahumada</surname>
							<given-names>D</given-names>
						</name>
						<name>
							<surname>Paredes</surname>
							<given-names>C</given-names>
						</name>
						<name>
							<surname>Abella</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>González</surname>
							<given-names>I</given-names>
						</name>
					</person-group>
					<source>Guía de validación de métodos en análisis químico cuantitativo</source>
					<publisher-name>INM</publisher-name>
					<publisher-loc>Bogotá</publisher-loc>
					<year>2023</year>
					<volume>1</volume>
				</element-citation>
			</ref>
			<ref id="B116">
				<label>[116]</label>
				<mixed-citation>[116] Fernandes T, Brito J, Gonçalves L. Analysis of Micronutrients y Heavy Metals in Portuguese Infant Milk Powders by Wavelength Dispersive X-ray Fluorescence Spectrometry (WDXRF). Food Analytical Methods. 2015;8152-57. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/S12161-014-9866-Y">https://doi.org/10.1007/S12161-014-9866-Y</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Fernandes</surname>
							<given-names>T</given-names>
						</name>
						<name>
							<surname>Brito</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Gonçalves</surname>
							<given-names>L</given-names>
						</name>
					</person-group>
					<article-title>Analysis of Micronutrients y Heavy Metals in Portuguese Infant Milk Powders by Wavelength Dispersive X-ray Fluorescence Spectrometry (WDXRF)</article-title>
					<source>Food Analytical Methods</source>
					<year>2015</year>
					<volume>8</volume>
					<issue>1</issue>
					<fpage>52</fpage>
					<lpage>57</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/S12161-014-9866-Y">https://doi.org/10.1007/S12161-014-9866-Y</ext-link>
				</element-citation>
			</ref>
			<ref id="B117">
				<label>[117]</label>
				<mixed-citation>[117] International Organization for Standardization (ISO). ISO 3534-1. Estadística: Vocabulario y símbolos. Parte 1: Términos de probabilidad y estadística general. 2006;1-105.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>International Organization for Standardization (ISO)</collab>
					</person-group>
					<source>ISO 3534-1. Estadística: Vocabulario y símbolos. Parte 1: Términos de probabilidad y estadística general</source>
					<year>2006</year>
					<fpage>1</fpage>
					<lpage>105</lpage>
				</element-citation>
			</ref>
			<ref id="B118">
				<label>[118]</label>
				<mixed-citation>[118] Domarchi C. Estudio de reproducibilidad de mediciones manuales de flujo vehicular: hacia la determinación de la exactitud y precisión de los estudios de base de tránsito. Ingeniería de Transporte. 2009;1353-8.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Domarchi</surname>
							<given-names>C</given-names>
						</name>
					</person-group>
					<article-title>Estudio de reproducibilidad de mediciones manuales de flujo vehicular: hacia la determinación de la exactitud y precisión de los estudios de base de tránsito</article-title>
					<source>Ingeniería de Transporte</source>
					<year>2009</year>
					<volume>13</volume>
					<issue>5</issue>
					<fpage>3</fpage>
					<lpage>8</lpage>
				</element-citation>
			</ref>
			<ref id="B119">
				<label>[119]</label>
				<mixed-citation>[119] Marguí E, Hidalgo M, Queralt I. Multielemental fast analysis of vegetation samples by wavelength dispersive X-ray fluorescence spectrometry: Possibilities y drawbacks. Spectrochimica Acta Part B. 2005;609-101363-1372. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.sab.2005.08.004">https://doi.org/10.1016/j.sab.2005.08.004</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Marguí</surname>
							<given-names>E</given-names>
						</name>
						<name>
							<surname>Hidalgo</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Queralt</surname>
							<given-names>I</given-names>
						</name>
					</person-group>
					<article-title>Multielemental fast analysis of vegetation samples by wavelength dispersive X-ray fluorescence spectrometry: Possibilities y drawbacks</article-title>
					<source>Spectrochimica Acta Part B</source>
					<year>2005</year>
					<volume>60</volume>
					<issue>9-10</issue>
					<fpage>1363</fpage>
					<lpage>1372</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.sab.2005.08.004">https://doi.org/10.1016/j.sab.2005.08.004</ext-link>
				</element-citation>
			</ref>
			<ref id="B120">
				<label>[120]</label>
				<mixed-citation>[120] Perring L, Blanc J. EDXRF determination of iron during infant cereals production y its fitness for purpose. International Journal of Food Science y Technology. 2007;425551-555. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1111/j.13652621.2006.01265.x">https://doi.org/10.1111/j.13652621.2006.01265.x</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Perring</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>Blanc</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<article-title>EDXRF determination of iron during infant cereals production y its fitness for purpose</article-title>
					<source>International Journal of Food Science y Technology</source>
					<year>2007</year>
					<volume>42</volume>
					<issue>5</issue>
					<fpage>551</fpage>
					<lpage>555</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1111/j.13652621.2006.01265.x">https://doi.org/10.1111/j.13652621.2006.01265.x</ext-link>
				</element-citation>
			</ref>
			<ref id="B121">
				<label>[121]</label>
				<mixed-citation>[121] Oliveira L, dos Santos W, Teixeira L, Korn M. Direct Analysis of Cocoa Powder, Chocolate Powder y Powdered Chocolate Drink for Multi-element Determination by Energy Dispersive X-ray Fluorescence Spectrometry. Food Analytical Methods. 2020;131195-202. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s12161-019-01565-w">https://doi.org/10.1007/s12161-019-01565-w</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Oliveira</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>dos Santos</surname>
							<given-names>W</given-names>
						</name>
						<name>
							<surname>Teixeira</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>Korn</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<article-title>Direct Analysis of Cocoa Powder, Chocolate Powder y Powdered Chocolate Drink for Multi-element Determination by Energy Dispersive X-ray Fluorescence Spectrometry</article-title>
					<source>Food Analytical Methods</source>
					<year>2020</year>
					<volume>13</volume>
					<issue>1</issue>
					<fpage>195</fpage>
					<lpage>202</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s12161-019-01565-w">https://doi.org/10.1007/s12161-019-01565-w</ext-link>
				</element-citation>
			</ref>
			<ref id="B122">
				<label>[122]</label>
				<mixed-citation>[122] Tsuji K, et al. New developments of X-ray fluorescence imaging techniques in laboratory. Spectrochimica Acta Part B. 2015;11343-53. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.sab.2015.09.001">https://doi.org/10.1016/j.sab.2015.09.001</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Tsuji</surname>
							<given-names>K</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>New developments of X-ray fluorescence imaging techniques in laboratory</article-title>
					<source>Spectrochimica Acta Part B</source>
					<year>2015</year>
					<volume>113</volume>
					<fpage>43</fpage>
					<lpage>53</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.sab.2015.09.001">https://doi.org/10.1016/j.sab.2015.09.001</ext-link>
				</element-citation>
			</ref>
			<ref id="B123">
				<label>[123]</label>
				<mixed-citation>[123] Turner A, Filella M. Field-portable-XRF reveals the ubiquity of antimony in plastic consumer products. Science of the Total Environment. 2017;584-585982-989. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.scitotenv.2017.01.149">https://doi.org/10.1016/j.scitotenv.2017.01.149</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Turner</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Filella</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<article-title>Field-portable-XRF reveals the ubiquity of antimony in plastic consumer products</article-title>
					<source>Science of the Total Environment</source>
					<year>2017</year>
					<volume>584-585</volume>
					<fpage>982</fpage>
					<lpage>989</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.scitotenv.2017.01.149">https://doi.org/10.1016/j.scitotenv.2017.01.149</ext-link>
				</element-citation>
			</ref>
			<ref id="B124">
				<label>[124]</label>
				<mixed-citation>[124] Singh V, Sharma N, Singh VK. Application of Wavelength Dispersive X-ray Fluorescence to Agricultural Disease Research. Spectroscopy. 2021;362223-30.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Singh</surname>
							<given-names>V</given-names>
						</name>
						<name>
							<surname>Sharma</surname>
							<given-names>N</given-names>
						</name>
						<name>
							<surname>Singh</surname>
							<given-names>VK</given-names>
						</name>
					</person-group>
					<article-title>Application of Wavelength Dispersive X-ray Fluorescence to Agricultural Disease Research</article-title>
					<source>Spectroscopy</source>
					<year>2021</year>
					<volume>36</volume>
					<issue>22</issue>
					<fpage>23</fpage>
					<lpage>30</lpage>
				</element-citation>
			</ref>
			<ref id="B125">
				<label>[125]</label>
				<mixed-citation>[125] Paulino T, et al. Validation of the analytical method using the Energy Dispersive X-ray Fluorescence technique (EDXRF) for application in pharmaceutical sciences. Brazilian Journal of Radiation Sciences. 2022;1041-20. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.15392/2319-0612.2022.2080">https://doi.org/10.15392/2319-0612.2022.2080</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Paulino</surname>
							<given-names>T</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>Validation of the analytical method using the Energy Dispersive X-ray Fluorescence technique (EDXRF) for application in pharmaceutical sciences</article-title>
					<source>Brazilian Journal of Radiation Sciences</source>
					<year>2022</year>
					<volume>10</volume>
					<issue>4</issue>
					<fpage>1</fpage>
					<lpage>20</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.15392/2319-0612.2022.2080">https://doi.org/10.15392/2319-0612.2022.2080</ext-link>
				</element-citation>
			</ref>
			<ref id="B126">
				<label>[126]</label>
				<mixed-citation>[126] Cruz G, Reza F, Yáñez Y. Espectroscopía de fluorescencia de rayos X por reflexión total (TXRF): Validación y aplicación en suplementos alimenticios. Revista Tendencias en Docencia e Investigación en Química. 2020;6686-93.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Cruz</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>Reza</surname>
							<given-names>F</given-names>
						</name>
						<name>
							<surname>Yáñez</surname>
							<given-names>Y</given-names>
						</name>
					</person-group>
					<article-title>Espectroscopía de fluorescencia de rayos X por reflexión total (TXRF): Validación y aplicación en suplementos alimenticios</article-title>
					<source>Revista Tendencias en Docencia e Investigación en Química</source>
					<year>2020</year>
					<volume>6</volume>
					<issue>6</issue>
					<fpage>86</fpage>
					<lpage>93</lpage>
				</element-citation>
			</ref>
			<ref id="B127">
				<label>[127]</label>
				<mixed-citation>[127] Tiwari M. Recent trends in X-ray fluorescence spectrometry: precise investigation of nanomaterials. Spectroscopy Europe. 2018;30115-19. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1255/sew.2018.a1">https://doi.org/10.1255/sew.2018.a1</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Tiwari</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<article-title>Recent trends in X-ray fluorescence spectrometry: precise investigation of nanomaterials</article-title>
					<source>Spectroscopy Europe</source>
					<year>2018</year>
					<volume>30</volume>
					<issue>1</issue>
					<fpage>15</fpage>
					<lpage>19</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1255/sew.2018.a1">https://doi.org/10.1255/sew.2018.a1</ext-link>
				</element-citation>
			</ref>
		</ref-list>
		<fn-group>
			<fn fn-type="other" id="fn1">
				<label>Citación del artículo:</label>
				<p> L. A. Pérez Díaz, J. Serna Saiz y H.Torres Quezada, &quot;Preparación de muestras sólidas para el análisis por fluorescencia de rayos X: una revisión&quot;, Rev. Colomb. Quim., vol. 52, nro. 3, pp. 21-40, 2023. DOI: <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.15446/rev.colomb.quim.v52n3.111499">https://doi.org/10.15446/rev.colomb.quim.v52n3.111499</ext-link>
				</p>
			</fn>
		</fn-group>
	</back>
</article>