<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article
  PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article article-type="research-article" dtd-version="1.1" specific-use="sps-1.9" xml:lang="en" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
	<front>
		<journal-meta>
			<journal-id journal-id-type="publisher-id">rfnam</journal-id>
			<journal-title-group>
				<journal-title>Revista Facultad Nacional de Agronomía Medellín</journal-title>
				<abbrev-journal-title abbrev-type="publisher">Rev. Fac. Nac. Agron. Medellín</abbrev-journal-title>
			</journal-title-group>
			<issn pub-type="ppub">0304-2847</issn>
			<issn pub-type="epub">2248-7026</issn>
			<publisher>
				<publisher-name>Facultad de Ciencias Agrarias - Universidad Nacional de Colombia</publisher-name>
			</publisher>
		</journal-meta>
		<article-meta>
			<article-id pub-id-type="doi">10.15446/rfnam.v75n1.96247</article-id>
			<article-categories>
				<subj-group subj-group-type="heading">
					<subject>Artículos</subject>
				</subj-group>
			</article-categories>
			<title-group>
				<article-title>Bioclimatic performance of wet coffee processing facilities: conditions for workers and coffee</article-title>
				<trans-title-group xml:lang="es">
					<trans-title>Desempeño bioclimático de instalaciones de procesamiento de café húmedo: condiciones para los trabajadores y el café</trans-title>
				</trans-title-group>
			</title-group>
			<contrib-group>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0001-9115-9057</contrib-id>
					<name>
						<surname>Guerra García</surname>
						<given-names>Lina Marcela</given-names>
					</name>
					<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
				</contrib>
				<contrib contrib-type="author" corresp="yes">
					<contrib-id contrib-id-type="orcid">0000-0002-8698-7234</contrib-id>
					<name>
						<surname>Osorio Hernández</surname>
						<given-names>Robinson</given-names>
					</name>
					<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0002-4358-3600</contrib-id>
					<name>
						<surname>Osorio Saráz</surname>
						<given-names>Jairo Alexander</given-names>
					</name>
					<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0003-3868-0307</contrib-id>
					<name>
						<surname>Carlo</surname>
						<given-names>Joyce Correna</given-names>
					</name>
					<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0002-8284-7496</contrib-id>
					<name>
						<surname>Damasceno</surname>
						<given-names>Flavio Alves</given-names>
					</name>
					<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
				</contrib>
			</contrib-group>
			<aff id="aff1">
				<label>1</label>
				<institution content-type="original"> Universidad Nacional de Colombia. Bogotá and Medellín campus, Colombia. lmguerra@unal.edu.co, rosorioh@unal.edu.co, aosorio@unal.edu.co</institution>
				<institution content-type="normalized">Universidad Nacional de Colombia</institution>
				<institution content-type="orgname">Universidad Nacional de Colombia</institution>
				<country country="CO">Colombia</country>
				<email>lmguerra@unal.edu.co</email>
				<email>rosorioh@unal.edu.co</email>
				<email>aosorio@unal.edu.co</email>
			</aff>
			<aff id="aff2">
				<label>2</label>
				<institution content-type="original"> Universidade Federal de Viçosa. Minas Gerais, Brasil. joycecarlo@ufb.br</institution>
				<institution content-type="normalized">Universidade Federal de Viçosa</institution>
				<institution content-type="orgname">Universidade Federal de Viçosa</institution>
				<addr-line>
					<city>Minas Gerais</city>
				</addr-line>
				<country country="BR">Brazil</country>
				<email>joycecarlo@ufb.br</email>
			</aff>
			<aff id="aff3">
				<label>3</label>
				<institution content-type="original"> Universidade Federal de Lavras. Minas Gerais, Brasil. flavio.damasceno@ufla.br</institution>
				<institution content-type="normalized">Universidade Federal de Lavras</institution>
				<institution content-type="orgname">Universidade Federal de Lavras</institution>
				<addr-line>
					<city>Minas Gerais</city>
				</addr-line>
				<country country="BR">Brazil</country>
				<email>flavio.damasceno@ufla.br</email>
			</aff>
			<pub-date date-type="pub" publication-format="electronic">
				<day>31</day>
				<month>01</month>
				<year>2022</year>
			</pub-date>
			<pub-date date-type="collection" publication-format="electronic">
				<season>Jan-Apr</season>
				<year>2022</year>
			</pub-date>
			<volume>75</volume>
			<issue>1</issue>
			<fpage>9763</fpage>
			<lpage>9772</lpage>
			<history>
				<date date-type="received">
					<day>02</day>
					<month>11</month>
					<year>2021</year>
				</date>
				<date date-type="accepted">
					<day>08</day>
					<month>12</month>
					<year>2021</year>
				</date>
			</history>
			<permissions>
				<license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by-nc-sa/4.0/" xml:lang="en">
					<license-p>This is an open-access article distributed under the terms of the Creative Commons Attribution License</license-p>
				</license>
			</permissions>
			<abstract>
				<title>ABSTRACT</title>
				<p>This study aimed to evaluate the bioclimatic performance of three wet coffee processing facilities in Colombia, focused on the conditions for workers and coffee parchment, through computer simulation. In addition to temperature and relative humidity, the Wet-Bulb Globe Temperature index (WBGT) was simulated during the highest coffee production month. The proposed simulation model was able to predict hygrothermal behavior within the three coffee processing facilities. Case 3 presented the warmest environment, and case 2 the most humid environment concerning the appropriate conditions for the coffee and the worker. The WBGT index limit was exceeded in case 3. Since this type of facility emits large amounts of heat and steam, constructive modifications are suggested to improve the environmental conditions of workers and coffee. Mainly, the physical separation of the heat exchangers is recommended, which ideally should be outside the post-harvest facility. The steam produced in the drying process should be quickly evacuated with ventilation strategies. Additionally, the use of strategies that reduce the energy gain from solar radiation is suggested.</p>
			</abstract>
			<trans-abstract xml:lang="es">
				<title>RESUMEN</title>
				<p>Este estudio tuvo como objetivo evaluar el desempeño bioclimático de tres instalaciones de procesamiento húmedo de café en Colombia, enfocado en las condiciones para los trabajadores y el café pergamino, a través de simulación computacional. Además de la temperatura y la humedad relativa, se simuló el índice de temperatura del globo negro y bulbo húmedo (WBGT) durante el mes de mayor producción de café. El modelo de simulación propuesto pudo predecir el comportamiento higrotérmico dentro de las tres instalaciones de procesamiento de café. El caso 3 presentó el ambiente más cálido, y el caso 2 el ambiente más húmedo con respecto a las condiciones adecuadas para el café y el trabajador. En el caso 3 se superó el límite del índice WBGT. Dado que este tipo de instalaciones emite grandes cantidades de calor y vapor, se sugieren modificaciones constructivas para mejorar las condiciones ambientales de los trabajadores y el café. Principalmente, se recomienda la separación física de los intercambiadores de calor, que idealmente deberían estar fuera de la instalación de poscosecha. El vapor producido en el secado debe evacuarse rápidamente con estrategias de ventilación. Además, se sugiere el uso de estrategias que reduzcan la ganancia de energía de radiación solar.</p>
			</trans-abstract>
			<kwd-group xml:lang="en">
				<title>Keywords:</title>
				<kwd>Computational simulation</kwd>
				<kwd>Hygrothermal behavior</kwd>
				<kwd>Post-harvest coffee</kwd>
				<kwd>Thermal comfort</kwd>
				<kwd>WBGT index.</kwd>
			</kwd-group>
			<kwd-group xml:lang="es">
				<title>Palabras clave:</title>
				<kwd>Simulación computacional</kwd>
				<kwd>Ambiente higrotérmico</kwd>
				<kwd>Poscosecha de café</kwd>
				<kwd>Confort térmico</kwd>
				<kwd>Índice WBGT</kwd>
			</kwd-group>
			<counts>
				<fig-count count="5"/>
				<table-count count="4"/>
				<equation-count count="5"/>
				<ref-count count="21"/>
				<page-count count="10"/>
			</counts>
		</article-meta>
	</front>
	<body>
		<p>In Colombia, coffee is mainly processed wet, through sub-processes that include pulping, fermentation, washing, and drying of the beans. The bioclimatic conditions of the facilities where these processes take place can be decisive for both the comfort of the workers (<xref ref-type="bibr" rid="B8">Guerra-García <italic>et al</italic>., 2019</xref>) and the quality preservation of dry parchment coffee. The coffee is often stored there for a long time (sometimes exceeding two weeks), where a large amount of heat and steam is generated by the machines during mechanical drying (<xref ref-type="bibr" rid="B16">Osorio <italic>et al</italic>., 2018</xref>; <xref ref-type="bibr" rid="B17">Osorio <italic>et al</italic>., 2020</xref>). </p>
		<p>On the one hand, according to <xref ref-type="bibr" rid="B21">Todd and Valleron (2015)</xref>, the heat generated by humans increases with increasing physical activity. <xref ref-type="bibr" rid="B19">Roscani <italic>et al</italic>. (2017)</xref> and <xref ref-type="bibr" rid="B9">Gutiérrez <italic>et al</italic>. (2018)</xref> stated that the combination of this situation with a stressful thermal environment can result in considerable occupational hazards. Workers in the wet coffee process develop physically demanding activities, in a hot and humid environment, which can generate heat stress, weakness in the general state of health, alterations in psychosensory reactions, and decreased productivity (<xref ref-type="bibr" rid="B19">Roscani <italic>et al</italic>. 2017</xref>; <xref ref-type="bibr" rid="B12">ISTAS-C, 2017</xref>; <xref ref-type="bibr" rid="B9">Gutiérrez <italic>et al</italic>. 2018</xref>).</p>
		<p>For the evaluation of workers&amp;apos; hygrothermal environment, the Ministry of Labor and Social Security of Colombia proposes that the appropriate temperature range should be between 14 and 25°C, and the relative humidity between 30 and 70%. For a more complete comfort analysis, the use of comfort indices is required.</p>
		<p>To evaluate human performance in work under conditions of exposure to heat, different standards have defined the use of the Wet Bulb Index and Globe Thermometer (WBGT). Among them, Resolution 2400 of 1979 establishes some provisions on housing, hygiene, and safety in the workplace in Colombia (<xref ref-type="bibr" rid="B13">MTSS, 1979</xref>), the international standard <xref ref-type="bibr" rid="B11">ISO 7243, (1982)</xref> estimates the heat stress of workers, as well as the Brazilian regulatory standard - NR 15, attachment n. 3 (<xref ref-type="bibr" rid="B2">ABNT-NBR, 2011</xref>). These last two standards also establish the lines for calculating the WBGT index, in addition to proposing its limits.</p>
		<p>The WBGT index is an indicator of thermal comfort that considers air temperature, metabolism, radiant heat, air velocity, and relative humidity as the main drivers of thermal overload (<xref ref-type="bibr" rid="B13">MTSS, 1979</xref>; <xref ref-type="bibr" rid="B11">ISO 7243, 1982</xref>; <xref ref-type="bibr" rid="B2">ABNT-NBR, 2011</xref>; <xref ref-type="bibr" rid="B19">Roscani <italic>et al</italic>. 2017</xref>). <xref ref-type="bibr" rid="B8">Guerra-García <italic>et al</italic>. (2019)</xref> used this index for comfort analysis in coffee post-harvest facilities in Colombia, obtaining satisfactory results.</p>
		<p>On the other hand, the quality of dry parchment coffee can be compromised during storage due to the hygrothermal conditions of the environment. According to <xref ref-type="bibr" rid="B18">Puerta (2016)</xref>, The quality of dry parchment coffee stored in Colombia, with humidity between 10 and 12% in the bean, can be preserved for a maximum of six months, with an air temperature below 20 °C and relative humidity between 60 and 70%. Different environmental conditions ultimately affect the taste and quality of the coffee drink.</p>
		<p>Studies on the bioclimatic performance of facilities for wet coffee processing are few. The available literature suggests that these buildings present unsuitable storage environments that can affect the quality of the coffee (<xref ref-type="bibr" rid="B17">Osorio <italic>et al</italic>., 2020</xref>). Additionally, there is very little research that evaluates the thermal comfort of workers within post-harvest facilities (<xref ref-type="bibr" rid="B8">Guerra-García <italic>et al</italic>., 2019</xref>). According to <xref ref-type="bibr" rid="B10">Herrera <italic>et al</italic>. (2015)</xref>, this is a widespread problem in the food industry, mainly in Latin America and the Caribbean.</p>
		<p>Computational simulation has become a useful tool for the design and bioclimatic evaluation of buildings since it allows the analysis of mass and energy transfer phenomena, internal loads, occupancy patterns, transitory analysis, among others (<xref ref-type="bibr" rid="B3">Al-Saadi and Al-Jabri, 2020</xref>). However, in the evaluation of the built environment, the computational simulation models must be validated with experimental data to obtain reliable results.</p>
		<p>One of the most internationally recognized bioclimatic and energy simulation software for buildings is EnergyPlus<sup>TM</sup>. This open-source software, developed by the US Department of Energy (DoE), is capable of simulating long periods of time with the help of local weather files. The EnergyPlus<sup>TM</sup> program is a collection of many program modules that work together to calculate the energy required for air conditioning of buildings using 3D geometries, climate files, internal loads (machines and metabolism), usage patterns, thermal properties of materials, among others (<xref ref-type="bibr" rid="B6">DoE, 2019</xref>).</p>
		<p>The EnergyPlus<sup>TM</sup> software allows generating computational models to evaluate the bioclimatic performance of coffee post-harvest facilities (<xref ref-type="bibr" rid="B16">Osorio <italic>et al</italic>., 2018</xref>), seeking solutions that benefit both the conservation of parchment coffee and the thermal comfort of the worker (<xref ref-type="bibr" rid="B8">Guerra-Gracía <italic>et al</italic>., 2019</xref>). This study aimed to evaluate the bioclimatic performance of three wet coffee processing plants in Colombia, focused on the comfort conditions of the workers and the environmental conditions for the conservation of parchment coffee.</p>
		<sec sec-type="materials|methods">
			<title>MATERIALS AND METHODS</title>
			<p>Three case studies corresponding to three wet coffee processing facilities were compared, which from now on will be called case 1, 2, and 3. Except for their architecture, the three cases have similar geographic location conditions (municipalities of the north region of Antioquia - Colombia), mechanical drying, annual production of 30 t of dry parchment coffee, and peak production in November. <xref ref-type="table" rid="t1">Table 1</xref> summarizes the description of the location and architectural details of the three case studies.</p>
			<p>
				<table-wrap id="t1">
					<label>Table 1</label>
					<caption>
						<title>Description of location and architectural details of the case studies.</title>
					</caption>
					<graphic xlink:href="2248-7026-rfnam-75-01-9763-gt1.png"/>
				</table-wrap>
			</p>
			<p>Data of air temperature and relative humidity inside the three study cases were collected employing an Extech Instruments datalogger of the RHT20 brand, using a temperature measurement interval between -40 and 70 °C with a resolution of 0.1 °C, as well as a range between 0 and 100% relative humidity, with a resolution of 0.1. The collections were carried out every 5 min during three continuous days in each case, in November 2016, by fixing the equipment in the geometric center of each installation. </p>
			<p>The computational simulation analysis was carried out in the EnergyPlus<sup>TM</sup> program, based on the weather file of the city of Medellín, due to its availability, proximity (linear distance from Medellín to Bello 12 km, Barbosa 34 km, and San Roque 65km), and a similar climate to the location zones of the facilities under study (<xref ref-type="bibr" rid="B5">DesignBuilder, 2017</xref>).</p>
			<p>For the simulation model, a 3D geometry of each case study was elaborated in the Sketchup® software. With the help of the OpenStudio plugin, thermal zones were created. Finally, files with an idf extension were generated for each case (<xref ref-type="fig" rid="f1">Figure 1</xref>).</p>
			<p>
				<fig id="f1">
					<label>Figure 1</label>
					<caption>
						<title>3D geometries of the three case studies: A case 1, B case 2 (yellow area), and C case 3.</title>
					</caption>
					<graphic xlink:href="2248-7026-rfnam-75-01-9763-gf1.jpg"/>
				</fig>
			</p>
			<p>The thermal properties of construction materials such as density, thermal conductivity, and specific heat were obtained from the <xref ref-type="bibr" rid="B1">ABNT-NBR 15220-2 (2005)</xref>. To simplify the 3D model in case 1, the areas with openwork brick were assumed as windows, adding sun protection to simulate interference with light (<xref ref-type="bibr" rid="B15">Osorio <italic>et al</italic>., 2016</xref>). The mass of the material composed of brick and concrete, constituted by stairs, hydraulic classifier, and fermentation tanks was quantified and added to the immediate wall, to consider the effect of thermal inertia in the three cases.</p>
			<p>For the calculation of the energy balances (<xref ref-type="disp-formula" rid="e1">Equation 1</xref>), the internal loads were considered: powers of the coffee processing equipment (pulping machines and mechanical drying), and the luminaires (<xref ref-type="table" rid="t2">Table 2</xref>). Likewise, the heat generated from the human metabolism was considered as 440 kcal h<sup>-1</sup> (512 W), corresponding to an intermittent work of lifting, pushing, or dragging weights (<xref ref-type="bibr" rid="B2">ABNT-NBR, 2011</xref>). </p>
			<p>
				<disp-formula id="e1">
					<graphic xlink:href="2248-7026-rfnam-75-01-9763-e1.png"/>
				</disp-formula>
			</p>
			<p>where,</p>
			<p>
				<inline-graphic xlink:href="2248-7026-rfnam-75-01-9763-i004.png"/>: Sum of internal convective loads (w);</p>
			<p>
				<inline-graphic xlink:href="2248-7026-rfnam-75-01-9763-i005.png"/>: Convective heat transfers from area surfaces (w);</p>
			<p>
				<inline-graphic xlink:href="2248-7026-rfnam-75-01-9763-i006.png"/>: Heat transferred through the grooves (w);</p>
			<p>
				<inline-graphic xlink:href="2248-7026-rfnam-75-01-9763-i007.png"/>: Heat transfer due to interzone air mixing (w);</p>
			<p>
				<inline-graphic xlink:href="2248-7026-rfnam-75-01-9763-i008.png"/>: Air systems outlet (w);</p>
			<p>
				<inline-graphic xlink:href="2248-7026-rfnam-75-01-9763-i009.png"/>: Stored energy (w);</p>
			<p>
				<inline-graphic xlink:href="2248-7026-rfnam-75-01-9763-i010.png"/>: <inline-graphic xlink:href="2248-7026-rfnam-75-01-9763-i011.png"/>
			</p>
			<p>
				<inline-graphic xlink:href="2248-7026-rfnam-75-01-9763-i012.png"/>: Zone air density (kg m<sup>-3</sup>);</p>
			<p>
				<inline-graphic xlink:href="2248-7026-rfnam-75-01-9763-i010.png"/>: Specific heat of the air (J kg<sup>-1</sup> °K<sup>-1</sup>);</p>
			<p>
				<inline-graphic xlink:href="2248-7026-rfnam-75-01-9763-i011.png"/>: Sensible heat capacity multiplier (J kg-1 °K-1).</p>
			<p>
				<table-wrap id="t2">
					<label>Table 2</label>
					<caption>
						<title>Power of machines for wet processing of coffee.</title>
					</caption>
					<graphic xlink:href="2248-7026-rfnam-75-01-9763-gt2.png"/>
				</table-wrap>
			</p>
			<p>The simulation was carried out for the entire month of November in each case, from hour to hour, to determine the bioclimatic performance of the facilities during the peak period of coffee production, specifically for analyzing the conditions for the workers and parchment coffee. <xref ref-type="table" rid="t3">Table 3</xref> shows the schedules used for the computational simulation in EnergyPlus<sup>TM</sup>. </p>
			<p>
				<table-wrap id="t3">
					<label>Table 3</label>
					<caption>
						<title>Schedules used for the computational simulation.</title>
					</caption>
					<graphic xlink:href="2248-7026-rfnam-75-01-9763-gt3.png"/>
				</table-wrap>
			</p>
			<p>For the validation of the computational model, the experimental data (720 data) of temperature and relative humidity of the air was used to calculate the Normal Mean Square Error (NMSE) (<xref ref-type="bibr" rid="B4">ASTM, 2002</xref>) (<xref ref-type="disp-formula" rid="e2">Equation 2</xref>). NMSE values less than 0.25 are considered acceptable and good indicators of concordance. The agreement between the experimental values and the simulated values increases as the value is closer to zero. </p>
			<p>
				<disp-formula id="e2">
					<graphic xlink:href="2248-7026-rfnam-75-01-9763-e2.png"/>
				</disp-formula>
			</p>
			<p>where Y<sub>pi</sub> is the predicted value, Y<sub>mi</sub> is the measured value, and <italic>n</italic> is the number of data.</p>
			<p>
				<xref ref-type="disp-formula" rid="e3">Equation 3</xref> was used to analyze the WBGT index in the three case studies from the simulations. It is suitable for the evaluation of internal environments (without solar load), according to NR 15, annex n. 3 (<xref ref-type="bibr" rid="B2">ABNT-NBR, 2011</xref>).</p>
			<p>
				<disp-formula id="e3">
					<graphic xlink:href="2248-7026-rfnam-75-01-9763-e3.png"/>
				</disp-formula>
			</p>
			<p>Where:</p>
			<p>T<sub>W</sub>: Natural wet bulb temperature, °C; and </p>
			<p>T<sub>g</sub>: Black globe temperature, °C.</p>
			<p>Since EnergyPlus<sup>TM</sup> provides no output data for the WBGT index, it was calculated from other output data that can be obtained through the software: the black globe temperature (T<sub>g</sub>) was cleared from the Radiant Mean Temperature (TRM) equation, proposed by <xref ref-type="bibr" rid="B7">Fanger (1972)</xref>. In <xref ref-type="disp-formula" rid="e4">Equation 4</xref>, TRM, T<sub>db</sub> and V<sub>a</sub> are data provided by the software.</p>
			<p>
				<disp-formula id="e4">
					<graphic xlink:href="2248-7026-rfnam-75-01-9763-e4.png"/>
				</disp-formula>
			</p>
			<p>Where:</p>
			<p>T<sub>g</sub>: Black globe temperature, (°C); </p>
			<p>T<sub>db</sub>: Dry bulb temperature, (°C); and </p>
			<p>V<sub>a</sub>: Air speed, (m s<sup>-1</sup>).</p>
			<p>The Wet Bulb Temperature was obtained by <xref ref-type="disp-formula" rid="e5">Equation 5</xref> (<xref ref-type="bibr" rid="B20">Stull, 2011</xref>), using data of T<sub>db</sub> and relative humidity of the air, supplied by EnergyPlus<sup>TM</sup>.</p>
			<p>
				<disp-formula id="e5">
					<graphic xlink:href="2248-7026-rfnam-75-01-9763-e5.png"/>
				</disp-formula>
			</p>
			<p>Where T<sub>W</sub>: wet bulb temperature, (°C); T<sub>db</sub>: dry bulb temperature and RH: relative air humidity (%).</p>
			<p>The tolerance limits of workers to heat exposure based on the WBGT index (°C) were determined by considering the most repetitive work in the three study cases, that is, lifting, pushing, or dragging heavy loads, with a metabolic rate of 440 kcal h<sup>-1</sup> (512 W), classified as heavy according to (<xref ref-type="bibr" rid="B2">ABNT-NBR, 2011</xref>). Based on these parameters, it was determined that the limit for the WBGT index of heavy activity, developed continuously during 1 h is 25 °C (<xref ref-type="bibr" rid="B2">ABNT-NBR, 2011</xref>).</p>
			<p>The WBGT index and hygrothermal behavior of the three study cases and of these cases with the external environment according to the simulations were compared using hourly data of November 2016. For this comparison, box plots were made for the three cases.</p>
			<p>Results were compared with the temperature of 20 °C and relative humidity of the air between 65 and 70% recommended by <xref ref-type="bibr" rid="B18">Puerta (2016)</xref> to preserve the quality of the stored dry parchment coffee.</p>
		</sec>
		<sec sec-type="results|discussion">
			<title>RESULTS AND DISCUSSION</title>
			<p>
				<xref ref-type="table" rid="t4">Table 4</xref> shows the results of validation of the models for the dry bulb temperature and relative humidity of the air, in the three study cases. The value of the NMSE in the three cases is less than 0.25, that is, the models represent the real conditions (<xref ref-type="bibr" rid="B4">ASTM, 2002</xref>), as well as the agreement between the measured and simulated temperature data for the three cases is observed in <xref ref-type="fig" rid="f2">Figure 2</xref>. </p>
			<p>
				<table-wrap id="t4">
					<label>Table 4</label>
					<caption>
						<title>Comparison of temperature and relative humidity of the air from experimental and simulation data with NMSE.</title>
					</caption>
					<graphic xlink:href="2248-7026-rfnam-75-01-9763-gt4.png"/>
				</table-wrap>
			</p>
			<p>
				<fig id="f2">
					<label>Figure 2</label>
					<caption>
						<title>Comparison of measured data and simulated temperature data, A. case 1, B. case 2, C. case 3.</title>
					</caption>
					<graphic xlink:href="2248-7026-rfnam-75-01-9763-gf2.jpg"/>
				</fig>
			</p>
			<p>Therefore, it is possible to affirm that the proposed simulation models are capable of predicting the hygrothermal behavior within the three facilities. The models can facilitate decision-making to improve the behavior of environmental variables within this type of construction. </p>
			<p>According to the simulations in EnergyPlus<sup>TM</sup>, <xref ref-type="fig" rid="f3">Figures 3A</xref> and <xref ref-type="fig" rid="f4">4A</xref> show the thermal behavior of the three cases and the external environment on an average day in November, and the general behavior in a box diagram, respectively. It is observed that the warmest environment occurs in case 3, and the coolest environment in case 2. Concerning workers, the temperature range must be between 14 and 25 °C (<xref ref-type="bibr" rid="B13">MTSS, 1979</xref>) and it is observed that the low limit is not exceeded. However, in the warmest hours of the day when there was greater solar radiation, case 3 exceeded the value of 30 °C, thus generating an environment of thermal stress at these hours. This effect can be corrected with passive strategies of natural ventilation. </p>
			<p>
				<fig id="f3">
					<label>Figure 3</label>
					<caption>
						<title>A. Average day temperature, B. Relative humidity of an average day of November for the three study cases.</title>
					</caption>
					<graphic xlink:href="2248-7026-rfnam-75-01-9763-gf3.jpg"/>
				</fig>
			</p>
			<p>
				<fig id="f4">
					<label>Figure 4</label>
					<caption>
						<title>Box plot for the three case studies for November: A. temperature, B. relative humidity.</title>
					</caption>
					<graphic xlink:href="2248-7026-rfnam-75-01-9763-gf4.jpg"/>
				</fig>
			</p>
			<p>For coffee, in the three study cases more than half of the time, the temperature was higher than the recommended limit to preserve the quality of the coffee (20 °C in storage). Similar to the behavior of the external environment, this behavior occurs during daylight hours (<xref ref-type="fig" rid="f3">Figure 3A</xref>). Case 3 was the most critical, since more than 80% of the time the temperature was above 20 °C. In this case, the temperature above the desired limit can be mitigated with passive strategies that decrease heat transfer by solar radiation, for example, the use of light or reflective colors on the roof.</p>
			<p>In case 1 and case 3, the heat exchangers of the coffee drying machines, which work with coffee husk and firewood, respectively (as the energy source for the drying process), had an impact on the increase in internal temperature, since their efficiency was 50%. The rest of the energy is emitted to the environment in the form of sensible heat. Additionally, in case 3 the aluminum cover (material with high thermal conductivity) and its low height contributed to higher temperatures during the hottest hours of the day.</p>
			<p>In case 2, there was a lower temperature inside because the drying machine has no heat exchanger. The coffee is dried with the direct flame from propane gas, therefore, the process emits less heat to the environment (<xref ref-type="bibr" rid="B14">Oliveros <italic>et al</italic>., 2009</xref>). Additionally, the construction has a large volume and receives little solar radiation due to neighboring buildings. However, this is not enough to keep the values within the recommended limit to preserve the quality of dry parchment coffee.</p>
			<p>
				<xref ref-type="fig" rid="f3">Figures 3B</xref> and <xref ref-type="fig" rid="f4">4B</xref> show the relative humidity behavior of the three cases and the external environment on an average day in November, and the general behavior in the box plot according to the simulations, respectively. It was observed that case 2 and case 1 presented the most and least humid environments. In <xref ref-type="fig" rid="f5">Figure 5</xref>, referred to workers, the relative humidity range should be between 30 and 70%. (<xref ref-type="bibr" rid="B13">MTSS, 1979</xref>), but it was observed that during the morning and at night this value was exceeded due to the steam emitted by the facility in the drying process and the reduction in the external temperature. Nevertheless, the relative humidity did not fall below 40%.</p>
			<p>
				<fig id="f5">
					<label>Figure 5</label>
					<caption>
						<title>Box plot of WBGT index in the three case studies.</title>
					</caption>
					<graphic xlink:href="2248-7026-rfnam-75-01-9763-gf5.jpg"/>
				</fig>
			</p>
			<p>
				<xref ref-type="fig" rid="f4">Figure 4B</xref> shows a wide range of relative humidity in the external environment, with values between 30% and close to 100%, due to the rains during the coffee harvest season in the area but also to some dry days with clear sky. Similar behavior was found in the case studies. Most of the data were outside the recommended range to preserve the quality of coffee (60 to 70%), and for the wellbeing of workers (30 to 70%). The most humid and critical environment was case 2.</p>
			<p>Case 1 has a greater area of natural ventilation openings; thus the relative humidity was lower, followed by case 3, with 32% and 49% of data above 70% relative humidity, respectively. In case 2, the area of ventilation openings is not sufficient for its volume, making it difficult to evacuate the steam generated by the drying process. This caused that 60% of the data exceeded the value of 70% relative humidity. This case represents a great biological risk for the proliferation of fungi and bacteria in coffee. </p>
			<p>The hygrothermal performance results indicate that none of the three facilities is suitable for the storage of dry parchment coffee all the time, since they require modifications through passive conditioning methods or the use of active conditioning systems as last resort. Regarding the comfort level of workers in coffee post-harvest facilities, the behavior of the WBGT index, calculated from the results of the simulations of the three case studies, can be observed in <xref ref-type="fig" rid="f5">Figure 5</xref>. </p>
			<p>It was found that the WBGT index exceeded 45% of the time in case 3, 3.3% in case 2 and less than 1% in case 1. Data that exceeded the limit of the index appeared due to both the high temperature and the humidity of the air, mainly because of the combination of wet coffee and drying processes within the same facilities. This hinders the loss of heat by perspiration (latent heat) and causes thermal stress (<xref ref-type="bibr" rid="B19">Roscani <italic>et al</italic>. 2017</xref>; <xref ref-type="bibr" rid="B12">ISTAS-C, 2017</xref>; <xref ref-type="bibr" rid="B9">Gutiérrez <italic>et al</italic>. 2018</xref>).</p>
			<p>It is possible to state that, with the predominance of values lower than the 25 °C limits in the three cases, the WBGT index does not represent a difficult problem, since it could be solved with the application of passive conditioning methods, mainly the physical separation of the spaces of the drying processes from those that generate heat and humidity in the environment. In other words, the heat exchangers of the drying machines should ideally be located externally to the post-harvest facility, and the steam produced in the drying must be quickly evacuated from the building, either with ventilation openings close to the steam outlet and favoring the chimney effect (<xref ref-type="bibr" rid="B17">Osorio <italic>et al</italic>., 2020</xref>) or with designs where the construction drying machine stands out.</p>
		</sec>
		<sec sec-type="conclusions">
			<title>CONCLUSIONS</title>
			<p>The proposed computational model is capable of predicting hygrothermal behavior, within the three case studies of facilities for wet coffee processing. Case 1 presented the best hygrothermal and comfort conditions, due to its design with the largest natural ventilation area and the largest volume of the three cases. Case 2 presented the most humid environment, and case 3 the warmest environment, which increases the biological risk for coffee storage. Regarding the WBGT index, case 3 presented the most unfavorable condition.</p>
			<p>To improve the environmental conditions for the workers and the coffee, constructive modifications are suggested. First of all, the heat exchangers of the dryers should ideally be located outside the post-harvest facility. Secondly, the steam produced in the drying should be quickly evacuated from the building, either with ventilation openings close to the steam outlet that favor the chimney effect or with designs where the construction dryer protrudes from the roof. Additionally, passive air conditioning strategies should be implemented to reduce the gain of solar radiation, such as painting the ceiling in light colors or with reflective colors or materials.</p>
		</sec>
	</body>
	<back>
		<ack>
			<title>ACKNOWLEDGMENTS</title>
			<p>The authors thank the Universidad Nacional de Colombia, the Universidade Federal de Viçosa, CAPES, CNPq, and the National Federation of Coffee Growers of Colombia. Special thanks to the coffee growers of Colombia.</p>
		</ack>
		<ref-list>
			<title>REFERENCES</title>
			<ref id="B1">
				<mixed-citation>ABNT - NBR. 2005. Associação Brasileira de Normas Tecnicas. Desempenho Térmico de Edificações-Parte 2: Métodos de cálculo da transmitância térmica, da capacidade térmica, do atraso térmico e do fator de calor solar de elementos e componentes de edificações. NBR 15220-2. Brasil.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>ABNT - NBR</collab>
					</person-group>
					<year>2005</year>
					<source>Desempenho Térmico de Edificações</source>
					<chapter-title>Parte 2: Métodos de cálculo da transmitância térmica, da capacidade térmica, do atraso térmico e do fator de calor solar de elementos e componentes de edificações</chapter-title>
					<comment>NBR 15220-2</comment>
					<publisher-loc>Brasil</publisher-loc>
				</element-citation>
			</ref>
			<ref id="B2">
				<mixed-citation>ABNT - NBR. 2011. Associação Brasileira de Normas Tecnicas. NORMA REGULAMENTADORA 15 - Atividades e Operações Insalubres. NR - 15. Brasil.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>ABNT - NBR</collab>
					</person-group>
					<year>2011</year>
					<source>NORMA REGULAMENTADORA 15 - Atividades e Operações Insalubres</source>
					<comment>NR - 15</comment>
					<publisher-loc>Brasil</publisher-loc>
				</element-citation>
			</ref>
			<ref id="B3">
				<mixed-citation>Al-Saadi SN and Al-Jabri KS. 2020. Optimization of envelope design for housing in hot climates using a genetic algorithm (GA) computational approach. Journal Building Engineering 32: 1-20. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jobe.2020.101712">https://doi.org/10.1016/j.jobe.2020.101712</ext-link>.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Al-Saadi</surname>
							<given-names>SN</given-names>
						</name>
						<name>
							<surname>Al-Jabri</surname>
							<given-names>KS</given-names>
						</name>
					</person-group>
					<year>2020</year>
					<article-title>Optimization of envelope design for housing in hot climates using a genetic algorithm (GA) computational approach</article-title>
					<source>Journal Building Engineering</source>
					<issue>32</issue>
					<fpage>1</fpage>
					<lpage>20</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.jobe.2020.101712">https://doi.org/10.1016/j.jobe.2020.101712</ext-link>
				</element-citation>
			</ref>
			<ref id="B4">
				<mixed-citation>ASTM. 2002. Guide for statistical evaluation of indoor air quality models. ASTM D5157-97. American Society for Testing Materials. United States. </mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>ASTM</collab>
					</person-group>
					<year>2002</year>
					<source>Guide for statistical evaluation of indoor air quality models</source>
					<comment>ASTM D5157-97</comment>
					<publisher-name>American Society for Testing Materials</publisher-name>
					<publisher-loc>United States</publisher-loc>
				</element-citation>
			</ref>
			<ref id="B5">
				<mixed-citation>DesignBuilder. 2017. Manual de ayuda DesignBuilder. In: <ext-link ext-link-type="uri" xlink:href="https://www.designbuilder-lat.com/soporte/manual-de-ayuda">https://www.designbuilder-lat.com/soporte/manual-de-ayuda</ext-link>
				</mixed-citation>
				<element-citation publication-type="software">
					<person-group person-group-type="author">
						<collab>DesignBuilder</collab>
					</person-group>
					<year>2017</year>
					<source>Manual de ayuda DesignBuilder</source>
					<ext-link ext-link-type="uri" xlink:href="https://www.designbuilder-lat.com/soporte/manual-de-ayuda">https://www.designbuilder-lat.com/soporte/manual-de-ayuda</ext-link>
				</element-citation>
			</ref>
			<ref id="B6">
				<mixed-citation>DoE. 2019. U. S. Departament of Energy. Engineering Reference - EnergyPlusTM Version 9.2.0 Documentation. U.S. Department of Energy, Washington D.C. 1741 p. </mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>DoE</collab>
					</person-group>
					<year>2019</year>
					<source>EnergyPlusTM</source>
					<comment>Version 9.2.0 Documentation</comment>
					<publisher-name>U.S. Department of Energy</publisher-name>
					<publisher-loc>Washington D.C.</publisher-loc>
					<size units="pages">1741</size>
				</element-citation>
			</ref>
			<ref id="B7">
				<mixed-citation>Fanger PO. 1972. Thermal comfort. Analysis and applications in environmental engineering (McGraw-Hill (ed.)).</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Fanger</surname>
							<given-names>PO</given-names>
						</name>
					</person-group>
					<year>1972</year>
					<source>Thermal comfort. Analysis and applications in environmental engineering</source>
					<publisher-name>McGraw-Hill</publisher-name>
				</element-citation>
			</ref>
			<ref id="B8">
				<mixed-citation>Guerra-García LM, Osorio-Saraz JA, Tinôco IFF and Osorio-Hernández R. 2019. Thermal comfort in buildings for wet processing of coffee. Revista de Arquitectura 21(2): 101-111. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.14718/RevArq.2019.21.2.2597">https://doi.org/10.14718/RevArq.2019.21.2.2597</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Guerra-García</surname>
							<given-names>LM</given-names>
						</name>
						<name>
							<surname>Osorio-Saraz</surname>
							<given-names>JA</given-names>
						</name>
						<name>
							<surname>Tinôco</surname>
							<given-names>IFF</given-names>
						</name>
						<name>
							<surname>Osorio-Hernández</surname>
							<given-names>R</given-names>
						</name>
					</person-group>
					<year>2019</year>
					<article-title>Thermal comfort in buildings for wet processing of coffee</article-title>
					<source>Revista de Arquitectura</source>
					<volume>21</volume>
					<issue>2</issue>
					<fpage>101</fpage>
					<lpage>111</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.14718/RevArq.2019.21.2.2597">https://doi.org/10.14718/RevArq.2019.21.2.2597</ext-link>
				</element-citation>
			</ref>
			<ref id="B9">
				<mixed-citation>Gutiérrez RE, Guerra KB and Gutiérrez MD. 2018. Evaluación de Riesgo por Estrés Térmico en Trabajadores de los Procesos de Incineración y Secado de una Empresa de Tableros Contrachapados. Informacion Tecnologica 29(3): 133-144. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.4067/S0718-07642018000300133">https://doi.org/10.4067/S0718-07642018000300133</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Gutiérrez</surname>
							<given-names>RE</given-names>
						</name>
						<name>
							<surname>Guerra</surname>
							<given-names>KB</given-names>
						</name>
						<name>
							<surname>Gutiérrez</surname>
							<given-names>MD</given-names>
						</name>
					</person-group>
					<year>2018</year>
					<article-title>Evaluación de Riesgo por Estrés Térmico en Trabajadores de los Procesos de Incineración y Secado de una Empresa de Tableros Contrachapados</article-title>
					<source>Informacion Tecnologica</source>
					<volume>29</volume>
					<issue>3</issue>
					<fpage>133</fpage>
					<lpage>144</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.4067/S0718-07642018000300133">https://doi.org/10.4067/S0718-07642018000300133</ext-link>
				</element-citation>
			</ref>
			<ref id="B10">
				<mixed-citation>Herrera JAA, Castellón EC, Barrera LMT and Novoa IPV. 2015. Evaluación de estrés térmico en una empresa productora de alimentos en Córdoba-Colombia. Revista Clepsidra 10(19): 113-124. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Herrera</surname>
							<given-names>JAA</given-names>
						</name>
						<name>
							<surname>Castellón</surname>
							<given-names>EC</given-names>
						</name>
						<name>
							<surname>Barrera</surname>
							<given-names>LMT</given-names>
						</name>
						<name>
							<surname>Novoa</surname>
							<given-names>IPV</given-names>
						</name>
					</person-group>
					<year>2015</year>
					<article-title>Evaluación de estrés térmico en una empresa productora de alimentos en Córdoba-Colombia</article-title>
					<source>Revista Clepsidra</source>
					<volume>10</volume>
					<issue>19</issue>
					<fpage>113</fpage>
					<lpage>124</lpage>
				</element-citation>
			</ref>
			<ref id="B11">
				<mixed-citation>ISO. 1982. Hot environments: estimation of the heat stress on working man, based on the WBGT index (wet bulb globe temperature). International Organization for Standardizationhttps ISO 7243. Switzerland.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>ISO</collab>
					</person-group>
					<year>1982</year>
					<source>Hot environments: estimation of the heat stress on working man, based on the WBGT index (wet bulb globe temperature)</source>
					<publisher-name>International Organization for Standardizationhttps</publisher-name>
					<comment>ISO 7243</comment>
					<publisher-loc>Switzerland</publisher-loc>
				</element-citation>
			</ref>
			<ref id="B12">
				<mixed-citation>ISTAS-C. 2017. Exposición laboral a estrés térmico por calor y sus efectos en la salud. España. In Fundacion Estatal para la prevencion de riesgos laborlaes. Instituto Sindical de Trabajo, Ambiente y Salud. </mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>ISTAS-C</collab>
					</person-group>
					<year>2017</year>
					<source>Exposición laboral a estrés térmico por calor y sus efectos en la salud</source>
					<publisher-loc>España</publisher-loc>
					<publisher-name>Fundacion Estatal para la prevencion de riesgos laborlaes</publisher-name>
					<publisher-name>Instituto Sindical de Trabajo, Ambiente y Salud</publisher-name>
				</element-citation>
			</ref>
			<ref id="B13">
				<mixed-citation>MTSS.1979. Por la cual se establecen algunas disposiciones sobre vivienda, higiene y seguridad en los establecimientos de trabajo. RESOLUCIÓN 2400 DE 1979. Ministério de Trabajo y Seguridad Social de Colombia. </mixed-citation>
				<element-citation publication-type="legal-doc">
					<person-group person-group-type="author">
						<collab>MTSS</collab>
					</person-group>
					<year>1979</year>
					<source>Por la cual se establecen algunas disposiciones sobre vivienda, higiene y seguridad en los establecimientos de trabajo</source>
					<comment>RESOLUCIÓN 2400 DE 1979</comment>
					<publisher-name>Ministério de Trabajo y Seguridad Social de Colombia</publisher-name>
				</element-citation>
			</ref>
			<ref id="B14">
				<mixed-citation>Oliveros CE, Sanz JR, Ramirez CA and Peñuela AE. 2009. Aprovechamiento eficiente de la energía en el secado mecánico del café. </mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Oliveros</surname>
							<given-names>CE</given-names>
						</name>
						<name>
							<surname>Sanz</surname>
							<given-names>JR</given-names>
						</name>
						<name>
							<surname>Ramirez</surname>
							<given-names>CA</given-names>
						</name>
						<name>
							<surname>Peñuela</surname>
							<given-names>AE</given-names>
						</name>
					</person-group>
					<year>2009</year>
					<source>Aprovechamiento eficiente de la energía en el secado mecánico del café</source>
				</element-citation>
			</ref>
			<ref id="B15">
				<mixed-citation>Osorio R., Guerra LM., Tinôco IFF, Martins JH, Souza CDF and Osorio J. 2016. Simulation of the internal environment of a post-harvest installation and a solar dryer of coffee. Revista Brasileira de Engenharia Agrícola e Ambiental 20(2): 163-168. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1590/1807-1929/agriambi.v20n2p163-168">https://doi.org/10.1590/1807-1929/agriambi.v20n2p163-168</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Osorio</surname>
							<given-names>R.</given-names>
						</name>
						<name>
							<surname>Guerra</surname>
							<given-names>LM.</given-names>
						</name>
						<name>
							<surname>Tinôco</surname>
							<given-names>IFF</given-names>
						</name>
						<name>
							<surname>Martins</surname>
							<given-names>JH</given-names>
						</name>
						<name>
							<surname>Souza</surname>
							<given-names>CDF</given-names>
						</name>
						<name>
							<surname>Osorio</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<year>2016</year>
					<article-title>Simulation of the internal environment of a post-harvest installation and a solar dryer of coffee</article-title>
					<source>Revista Brasileira de Engenharia Agrícola e Ambiental</source>
					<volume>20</volume>
					<issue>2</issue>
					<fpage>163</fpage>
					<lpage>168</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1590/1807-1929/agriambi.v20n2p163-168">https://doi.org/10.1590/1807-1929/agriambi.v20n2p163-168</ext-link>
				</element-citation>
			</ref>
			<ref id="B16">
				<mixed-citation>Osorio R, Tinôco I de FF, Carlo JC, Saraz JAO and Torres IDA. 2018. Bioclimatic analysis of three buildings for wet processing of coffee in Colombia. Revista Facultad Nacional de Agronomia Medellin 71(3): 8609-8616. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.15446/rfnam.v71n3.64566">https://doi.org/10.15446/rfnam.v71n3.64566</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Osorio</surname>
							<given-names>R</given-names>
						</name>
						<name>
							<surname>Tinôco I de</surname>
							<given-names>FF</given-names>
						</name>
						<name>
							<surname>Carlo</surname>
							<given-names>JC</given-names>
						</name>
						<name>
							<surname>Saraz</surname>
							<given-names>JAO</given-names>
						</name>
						<name>
							<surname>Torres</surname>
							<given-names>IDA</given-names>
						</name>
					</person-group>
					<year>2018</year>
					<article-title>Bioclimatic analysis of three buildings for wet processing of coffee in Colombia</article-title>
					<source>Revista Facultad Nacional de Agronomia Medellin</source>
					<volume>71</volume>
					<issue>3</issue>
					<fpage>8609</fpage>
					<lpage>8616</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.15446/rfnam.v71n3.64566">https://doi.org/10.15446/rfnam.v71n3.64566</ext-link>
				</element-citation>
			</ref>
			<ref id="B17">
				<mixed-citation>Osorio R, Saraz JAO, Oliveira KS, Aristizaba ID and Arango JC. 2020. Computational fluid dynamics assessment of effect of different openings configurations on the thermal environment of a facility for coffee wet processing. Journal of Agricultural Engineering 51(1): 21-26. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.4081/jae.2020.892">https://doi.org/10.4081/jae.2020.892</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Osorio</surname>
							<given-names>R</given-names>
						</name>
						<name>
							<surname>Saraz</surname>
							<given-names>JAO</given-names>
						</name>
						<name>
							<surname>Oliveira</surname>
							<given-names>KS</given-names>
						</name>
						<name>
							<surname>Aristizaba</surname>
							<given-names>ID</given-names>
						</name>
						<name>
							<surname>Arango</surname>
							<given-names>JC</given-names>
						</name>
					</person-group>
					<year>2020</year>
					<article-title>Computational fluid dynamics assessment of effect of different openings configurations on the thermal environment of a facility for coffee wet processing</article-title>
					<source>Journal of Agricultural Engineering</source>
					<volume>51</volume>
					<issue>1</issue>
					<fpage>21</fpage>
					<lpage>26</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.4081/jae.2020.892">https://doi.org/10.4081/jae.2020.892</ext-link>
				</element-citation>
			</ref>
			<ref id="B18">
				<mixed-citation>Puerta G. 2016. Calidad física del café de varias regiones de Colombia según altitud, suelos y buenas prácticas de beneficio. Cenicafé 67(1): 7-40. </mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Puerta</surname>
							<given-names>G</given-names>
						</name>
					</person-group>
					<year>2016</year>
					<article-title>Calidad física del café de varias regiones de Colombia según altitud, suelos y buenas prácticas de beneficio</article-title>
					<source>Cenicafé</source>
					<volume>67</volume>
					<issue>1</issue>
					<fpage>7</fpage>
					<lpage>40</lpage>
				</element-citation>
			</ref>
			<ref id="B19">
				<mixed-citation>Roscani RC, Bitencourt DP, Maia PA and Ruas AC. 2017. Risco de exposição à sobrecarga térmica para trabalhadores da cultura de cana-de-açúcar no Estado de São Paulo, Brasil. Cadernos de Saúde Pública 33(3): 1-15. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1590/0102-311X00211415">https://doi.org/10.1590/0102-311X00211415</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Roscani</surname>
							<given-names>RC</given-names>
						</name>
						<name>
							<surname>Bitencourt</surname>
							<given-names>DP</given-names>
						</name>
						<name>
							<surname>Maia</surname>
							<given-names>PA</given-names>
						</name>
						<name>
							<surname>Ruas</surname>
							<given-names>AC</given-names>
						</name>
					</person-group>
					<year>2017</year>
					<article-title>Risco de exposição à sobrecarga térmica para trabalhadores da cultura de cana-de-açúcar no Estado de São Paulo, Brasil</article-title>
					<source>Cadernos de Saúde Pública</source>
					<volume>33</volume>
					<issue>3</issue>
					<fpage>1</fpage>
					<lpage>15</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1590/0102-311X00211415">https://doi.org/10.1590/0102-311X00211415</ext-link>
				</element-citation>
			</ref>
			<ref id="B20">
				<mixed-citation>Stull R. 2011. Wet-bulb temperature from relative humidity and air temperature. Journal of Applied Meteorology and Climatology 50(11): 2267-2269. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1175/JAMC-D-11-0143.1">https://doi.org/10.1175/JAMC-D-11-0143.1</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Stull</surname>
							<given-names>R</given-names>
						</name>
					</person-group>
					<year>2011</year>
					<article-title>Wet-bulb temperature from relative humidity and air temperature</article-title>
					<source>Journal of Applied Meteorology and Climatology</source>
					<volume>50</volume>
					<issue>11</issue>
					<fpage>2267</fpage>
					<lpage>2269</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1175/JAMC-D-11-0143.1">https://doi.org/10.1175/JAMC-D-11-0143.1</ext-link>
				</element-citation>
			</ref>
			<ref id="B21">
				<mixed-citation>Todd N and Valleron AJ. 2015. Space-time covariation of mortality with temperature: a systematic study of deaths in France, 1968-2009. Environmental Health Perspectives 123(7): 659. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1289/ehp.1307771">https://doi.org/10.1289/ehp.1307771</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Todd</surname>
							<given-names>N</given-names>
						</name>
						<name>
							<surname>Valleron</surname>
							<given-names>AJ</given-names>
						</name>
					</person-group>
					<year>2015</year>
					<article-title>Space-time covariation of mortality with temperature: a systematic study of deaths in France, 1968-2009</article-title>
					<source>Environmental Health Perspectives</source>
					<volume>123</volume>
					<issue>7</issue>
					<fpage>659</fpage>
					<lpage>659</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1289/ehp.1307771">https://doi.org/10.1289/ehp.1307771</ext-link>
				</element-citation>
			</ref>
		</ref-list>
	</back>
</article>