Publicado

2023-03-03

Rehabilitation and reforms of issues in vehicle parks lots and tower blocks structures

Rehabilitación y reformas de emisiones en aparcamientos de vehículos y estructuras de torres

DOI:

https://doi.org/10.15446/dyna.v90n225.102596

Palabras clave:

building envelope; cladding system; rehabilitation; reforms; vehicle parks; tower blocks (en)
envoltura de construcción; sistema de revestimiento; rehabilitación; reformas; aparcamientos de vehículos; bloques de torre (es)

Autores/as

Unsafe, offensive, and damaging to the environment. Homeowners and builders are searching for efficient ways to transform worn-out houses into desirable ones in light of these difficulties. In this study, we sought to address the issue of rehabilitation and reforms in parking lots for vehicles (VP) and tower buildings (TB). The most effective cladding system for building envelope purposes currently has been discovered to be a new generation of rainproof substructures, whose installation is actually much easier than it first appears and is a constructive solution that perfectly fits with current sustainable architecture trends.

Inseguros, ofensivos y dañinos para el medio ambiente. Los propietarios de viviendas y los constructores están buscando formas eficientes de transformar casas desgastadas en casas deseables a la luz de estas dificultades. En este estudio se buscó abordar el tema de rehabilitación y reformas en estacionamientos de vehículos (VP) y edificios torre (TB). Se ha descubierto que el sistema de revestimiento más eficaz para la envolvente de edificios en la actualidad es una nueva generación de subestructuras impermeables, cuya instalación es mucho más fácil de lo que parece y es una solución constructiva que encaja perfectamente con las tendencias actuales de arquitectura sostenible.

Referencias

Straube, J. and Finch, G., Report 0906. Ventilated wall claddings: review, field performance, and hygrothermal, and hygrothermal modelling. Test Waterloo, 2009, 25 P.

Gudum, C., Moisture transport and convection in building envelopes. Thesis, Department of Civil Engineering, Technical University of Denmark, Denmark, 2003.

Bassett, M. and McNeil, S., Ventilating wall cavities windows. Journal of Building Physics, 32(4), pp. 305-318, 2009. DOI: https://doi.org/10.1177/1744259108093682

Sandin, K., Skalmurskonstuktionens fuktoch temperature betingelser, R43:1991, Technical University College, Lund [in Swedish].

Blocken, B. and Carmeliet, J., High- resolution wind-driven-rain measurements on a low-rise building- experimental data for model development and model validation. Journal of Wind Engineering and Industrial aerodynamics, 93(12), pp. 905-928, 2005. DOI: https://doi.org/10.1016/j.jweia.2005.09.004

Straube, J.G. and Finch, G., Report 0906: ventilated wall claddings: review, field performance, and hygrothermal modeling. test, Building X, Science Corporation, 25, 2009, 16 P.

Cladding Market Analysis by Product (Steel, Aluminum, Composite Panels, Fiber Cement, Terracotta, Ceramic), by Application, Competitive Landscape, and Segment Forecasts, Grand View Research, 2018-2025.

Finch, G. and Straube, J., Ventilated wall claddings: review, field performance and hygrothermal modeling, in: Proceedings of the thermal performance of the exterior envelopes of whole buildings Clearwater, Florida. X, 2, 2007

Falk, J. and Sandin, K., Ventilated rainscreen cladding: measurements of cavity air velocities, estimation of air change rates and evaluation of driving forces, Build. Environ. 59, pp. 164-176, 2013. DOI: https://doi.org/10.1016/j.buildenv.2012.08.017

Falk, J. and Sandin, K., Ventilated rainscreen cladding: a study of the ventilation drying process, Build. Environ. 60, pp. 173–184, 2013. DOI: https://doi.org/10.1016/j.buildenv.2012.11.015

Langmans, J. and Roels, S., Experimental analysis of cavity ventilation behind rainscreen cladding systems: a comparison of four measuring techniques, Build. Environ. 87, pp. 177-192, 2015. DOI: https://doi.org/10.1016/j.buildenv.2015.01.030

Vanpachtenbeke, M., Langmans, J., Van den Bulcke, J. and Van Acker, S., Roels, on the drying potential of cavity ventilation behind brick veneer cladding: a detailed field study, Build. Environ. 123, pp. 133-145, 2017. DOI: https://doi.org/10.1016/j.buildenv.2017.06.047

Manuel, V., Franc’s, S., Jose, E., Manuel, J., Bannier, E., Cantavella, V. and Silva, G., Modeling of ventilated facades for energy building simulation software, Energy Build. 65, pp. 419-428, 2013. DOI: http://dx.doi.org/10.1016/j.enbuild.2013.06.015

Patania, F., Gagliano, A., Nocera, F.A. and Ferlito, A.G., Thermofluid-dynamic analysis of ventilated facades, Energy Build. 42(7), pp. 1148-1155, 2010. DOI: https://doi.org/10.1016/j.enbuild.2010.02.006

Gagliano, A. and Aneli, S., Analysis of the energy performance of an Opaque Ventilated Façade under winter and summer weather conditions, Sol. Energy 205, pp. 531-544, 2020. DOI: https://doi.org/10.1016/j.solener.2020.05.078

Stazi, F., Ulpiani, G., Pergolini, M., Di Perna, C. and D’Orazio, M., The role of wall layers properties on the thermal performance of ventilated facades: experimental investigation on narrow-cavity design, Energy Build, 209, art. 109622, 2020. DOI: https://doi.org/10.1016/j.enbuild.2019.109622

Nore, K., Blocken, B. and Thue, J.V., On CFD simulation of wind-induced airflow in narrow ventilated facade cavities: coupled and decoupled simulations and modelling limitations, Build. Environ. 45(8), pp. 1834-1846, 2010. DOI: https://doi.org/10.1016/j.buildenv.2010.02.014

Labat, M., Woloszyn, M., Garnier, G., Rusaouen, G.J.J. and Roux, J.J., Impact of direct solar irradiance on heat transfer behind an open-jointed ventilated cladding: experimental and numerical investigations, Sol. Energy 86(9), pp. 2549-2560, 2012. DOI: https://doi.org/10.1016/j.solener.2012.05.030

Sanjuan, C., Suarez, M.J., Gonzalez, M., Pistono, J. and Blanco, E., Energy performance of an open-joint ventilated facade compared with a conventional sealed cavity facade, Sol. Energy 85, pp. 1851-1863, 2011. DOI: https://doi.org/10.1016/j.solener.2011.04.028

Sanchez, M.N., Sanjuan, C., Suarez, M.J. and Heras, M.R., Experimental assessment of the performance of open joint ventilated facades with buoyancy-driven airflow, Sol. Energy, 91, pp. 131-144, 2013. DOI: https://doi.org/10.1016/j.solener.2013.01.019

Sanchez, M.N., Giancola, E., Suarez, M.J., Blanco, E. and Heras, M.R., Experimental evaluation of the airflow behaviour in horizontal and vertical Open Joint Ventilated Facades using Stereo-PIV, Renew. Energy 109, pp. 613-623, 2017. DOI: https://doi.org/10.1016/j.renene.2017.03.082

Sanjuan, C., Jose, M., Blanco, E. and Heras, R., Development and experimental validation of a simulation model for open joint ventilated facades, Energy Build. 43(12), pp. 3446-3456, 2011. DOI: https://doi.org/10.1016/j.enbuild.2011.09.005

Lopez, F.P., Numerical and experimental analysis of the energy saving and potential of ventilation of opaque ventilates facades, 2012.

Sag, E. and Matejka, L., Numerical study of the influence of insect grille on airflow in ventilated facade constructions, Adv. Mater. Res. 1041, pp. 31-34, 2014. DOI: https://doi.org/10.4028/www.scientific.net/AMR.1041.31

Stazi, F., Tomassoni, F., Veglio, A. and Perna, C.D., Experimental evaluation of ventilated walls with an external clay cladding, Renew. Energy 36(12), pp. 3373-3385, 2011. DOI: https://doi.org/10.1016/j.renene.2011.05.016

Stazi, F., Veglio, A. and Di Perna, C., Experimental assessment of a zinc-titanium ventilated facade in a Mediterranean climate, Energy Build. 69, pp. 525-534, 2014. DOI: https://doi.org/10.1016/j.enbuild.2013.11.043

Cómo citar

IEEE

[1]
M. Bajad, «Rehabilitation and reforms of issues in vehicle parks lots and tower blocks structures », DYNA, vol. 90, n.º 225, pp. 39–44, mar. 2023.

ACM

[1]
Bajad, M. 2023. Rehabilitation and reforms of issues in vehicle parks lots and tower blocks structures . DYNA. 90, 225 (mar. 2023), 39–44. DOI:https://doi.org/10.15446/dyna.v90n225.102596.

ACS

(1)
Bajad, M. Rehabilitation and reforms of issues in vehicle parks lots and tower blocks structures . DYNA 2023, 90, 39-44.

APA

Bajad, M. (2023). Rehabilitation and reforms of issues in vehicle parks lots and tower blocks structures . DYNA, 90(225), 39–44. https://doi.org/10.15446/dyna.v90n225.102596

ABNT

BAJAD, M. Rehabilitation and reforms of issues in vehicle parks lots and tower blocks structures . DYNA, [S. l.], v. 90, n. 225, p. 39–44, 2023. DOI: 10.15446/dyna.v90n225.102596. Disponível em: https://revistas.unal.edu.co/index.php/dyna/article/view/102596. Acesso em: 20 mar. 2026.

Chicago

Bajad, Mohankumar. 2023. «Rehabilitation and reforms of issues in vehicle parks lots and tower blocks structures ». DYNA 90 (225):39-44. https://doi.org/10.15446/dyna.v90n225.102596.

Harvard

Bajad, M. (2023) «Rehabilitation and reforms of issues in vehicle parks lots and tower blocks structures », DYNA, 90(225), pp. 39–44. doi: 10.15446/dyna.v90n225.102596.

MLA

Bajad, M. «Rehabilitation and reforms of issues in vehicle parks lots and tower blocks structures ». DYNA, vol. 90, n.º 225, marzo de 2023, pp. 39-44, doi:10.15446/dyna.v90n225.102596.

Turabian

Bajad, Mohankumar. «Rehabilitation and reforms of issues in vehicle parks lots and tower blocks structures ». DYNA 90, no. 225 (marzo 3, 2023): 39–44. Accedido marzo 20, 2026. https://revistas.unal.edu.co/index.php/dyna/article/view/102596.

Vancouver

1.
Bajad M. Rehabilitation and reforms of issues in vehicle parks lots and tower blocks structures . DYNA [Internet]. 3 de marzo de 2023 [citado 20 de marzo de 2026];90(225):39-44. Disponible en: https://revistas.unal.edu.co/index.php/dyna/article/view/102596

Descargar cita

CrossRef Cited-by

CrossRef citations0

Dimensions

PlumX

Visitas a la página del resumen del artículo

650

Descargas

Los datos de descargas todavía no están disponibles.