Publicado

2019-01-01

Cálculo de H(50) y E(50) para 90sr - 90y utilizando el hatm y los modelos voxelizado de la mujer y hombre adultos de referencia de la ICRP

Estimation of h(50) and e(50) for 90sr - 90y using hatm and the voxelized model for ICRP reference adult male and adult female

Palabras clave:

Dosimetría interna, fracción absorbida (es)
Absorbed fraction, internal dosimetry (en)

Descargas

Autores/as

  • Jorge Anselmo Puerta Ortiz Universidad Nacional de Colombia Sede Medellín
  • Bibiana Andrea Peña Velásquez Universidad Nacional de Colombia - Sede Medellín
  • Vanessa Peña Marín Universidad Nacional de Colombia - Sede Medellín https://orcid.org/0000-0001-9551-1185
  • Juan Camilo Ocampo Ramos Universidad Nacional de Colombia - Sede Medellín
  • Javier Morales Aramburo Universidad Nacional de Colombia - Sede Medellín
La Comisión Internacional de Protección Radiológica, ICRP, propuso una nueva metodología para el cálculo de coeficientes de dosis para trabajador ocupacionalmente expuesto que cambia la propuesta en las publicaciones 60 y 78 de la misma comisión. En este trabajo se reprodujeron los valores AF para hombre adulto reportados en la publicación 100 de la ICRP utilizando el software MCNPx y se calcularon con la misma metodología los SAFs para los compartimentos del HATM de mujer adulta, para electrones monoenergéticos dentro del rango de energías de 0.01 a 4 MeV. Se calcularon los SAFs en phantom voxelizados para hombre y mujer adulto, cuya estructura anatómica se reporta en la publicación 110 de la misma Comisión, usando la misma metodología de cálculo con el software MCNPx. Con estos datos se calcularon los coeficientes h(50) y e(50) para incorporación única por ingestión del 90Sr – 90Y, dada su importancia dosimétrica. Se consideraron las fracciones de absorción en intestino delgado reportados por la ICRP 78 y la metodología recomendada por la publicación 103 de la ICRP, encontrando valores de e(50) menores que los reportados por la ICRP en sus publicaciones. Finalmente se comparan los valores obtenidos con los reportados por Wei Bo Li et al.
International Commission for Radiological Protection, ICRP, proposed a new methodology for the calculation of dose coefficients for occupationally exposed workers that changes the proposal in publications 60 and 78 of the same commission. In this work, the AF values for adult men reported in publication 100 of the ICRP were reproduced using the MCNPx software and the SAFs were calculated with the same methodology for the compartments of the HATM of adult women, for monoenergetic electrons within the energy range of 0.01 to 4 MeV. We calculated voxel phantom SAFs for adult men and women, whose anatomical structure is reported in publication 110 of the same Commission, using the same calculation methodology with the MCNPx software. With this data, the coefficients h (50) and e (50) were calculated for single incorporation by ingestion of 90Sr - 90Y, given their dosimetric importance. We considered the absorption fractions in the small intestine reported by ICRP 78 and the methodology recommended by publication 103 of the ICRP, finding values of e (50) lower than reported by the ICRP in its publications. Finally, the obtained values are compared with those reported by Wei Bo Li et al.

Referencias

AIDE Software. (2007). Activities and Internal Dose Estimates. Versión 6.0.

Cristy, M., Eckerman, K.F., (1993). SEECAL: Program to Calculate Age-dependent Specific Effective Energies, ORNL/TM-12351, Oak Ridge National Laboratory,

ICRP. (1979). Limits for intakes of radionuclides by workers. Publication 30, Part 1. Ann. ICRP (3/4). Pergamon Press.

ICRP. (2007). Human Alimentary Tract Model for Radiological Protection, Publication 100. ESEVIER.

ICRP. (1993) Age-Dependent Doses to Members of the Public from Intakes of radionuclides, Part 2, Publication 67, Pergamon Press.

ICRP. (2009). Adult reference computational phantoms. ICRP Publication 110. Ann. ICRP 39(2). Elsevier.

ICRP. (2008). Nuclear Decay Data for Dosimetric Calculations. Publication 107.Ann. ICRP 38 (3). Elsevier.

ICRP. (2007). Recommendations of the International Commission on Radiological Protection. Publication 103. Ann. ICRP 37(2–4). Elsevier.

ICRP. (1991). Recommendations of the International Commission on Radiological Protection. Publication 60, Pergamon Press,

ICRP. (1994). Human. Respiratory Tract Model for Radiological protection, Publication 66. Ann. ICRP 24 (1-3).

Ocampo, J.C., Puerta, J.A. and Morales, J. (2013). Evaluation of specific absorbed fractions from internal photon sources in the ICRP reference male phantom. Radiation Protection Dosimetry, Vol. 157, No. 1, pp. 133–141.

Pelowitz, D. B. (2005). MCNPX User’s Manual Version 2.5.0.Report LA-CP-05–0369. Los Alamos National Laboratory.

Wei Bo Li, Vera Höllriegl, Paul Roth, Uwe Oeh. (2006). Human biokinetics of strontium. Part I: Intestinal absorption rate and its impact on the dose coefficient of 90Sr after ingestion. Radiation Environmental Biophysics 45: 115–124

Cómo citar

Cálculo de H(50) y E(50) para 90sr - 90y utilizando el hatm y los modelos voxelizado de la mujer y hombre adultos de referencia de la ICRP. (2019). Revista De La Facultad De Ciencias, 8(1), 6-19. https://doi.org/10.15446/rev.fac.cienc.v8n1.71572