Publicado

2019-01-01

Development of an easy-to-assemble external fixation system for bone transport

Desarrollo de un sistema de fijación externa fácil de ensamblar para transporte óseo

DOI:

https://doi.org/10.15446/dyna.v86n208.68012

Palabras clave:

bone elongation, external fixation system, bone fractures (en)

Autores/as

We developed a monolateral external fixation system for bone elongation easier to assemble than commercial systems since the clamps can be laterally assembled to the rail in contrast to the commercial systems where the clamps can only be assembled from the ends. The system is formed by clamps, screws, and a rail. The rail is composed of two carbon fiber circular rods of ½” diameter and 42-cm length. The clamps can slide with respect to the rail to allow bone distraction or may be fixed to the rail by using a wedge and a screw. The prototype was mechanically evaluated under the ASTM F1541 standard. The stiffness in axial, Medio Lateral bending (ML), Antero Posterior bending (AP), and flexo-torsional load were 117 N/mm, 46 N/mm, 8.7 N/mm, and 5.8 N-mm/°, respectively, which are on the range of stiffness of commercial systems. 

Referencias

Valbuena-Cortes S., Muertes y lesiones no fatales por accidentes de transporte, Colombia, 2011. Instituto Nacional de Medicina Legal y Ciencias Forenses, Bogotá, Colombia. [en línea]. [Consultado: 10 de julio de 2017]. Disponible en: http://www.medicinalegal.gov.co/documents/10180/34616/7-F-11-Transito.pdf/40ea4d45-f98b-4289-879e-73dbb811789d.

Aro, H.T. and Chao, E.Y.S., Biomechanical performance of the standard orthofix external fixtor and cortical screws. In De Bastiani, G., Apley, A.G. and Goldberg ,A., Orthofix external fixation in trauma and orthopaedics, Springer [online]. 2000, pp. 45-70. Available at: https://link.springer.com/book/10.1007%2F978-1-4471-0691-3

Cánovas, C.S., Bone elongation using monolateral external fixation: a practical guide. Strategies Trauma Limb Reconstr. [online]. 10(3), pp. 175-188, 2015. Available at: https://link.springer.com/article/10.1007%2Fs11751-015-0236-0.

Goldberg, A. y Scott, J., Fijación externa Orthofix: conceptos básicos, [en línea]. [Consultado: 10 de julio de 2017]. Disponible en: http://webs.ono.com/jmbarrera/Documentos/Conceptos%20basicos.pdf.

Leyton, A., García, J.J., Machado, A. y Echeverry, A., Caracterización mecánica del fijador multiaxial “Atlas” para fractura de huesos, Ingeniería y Competitividad, 5(1), pp. 7-15, 2003. DOI: 10.25100/iyc.v5i1.2300

Grande, J.F. y López, J.O., Diseño, construcción y evaluación de un prototipo de fijación externa para transporte y alargamiento óseo. Trabajo de grado de Ingeniería Mecánica, Universidad del Valle, Cali, Colombia, 2015.

Ortega, F., Diseño y evaluación de un riel hecho de material compuesto reforzado con fibra de carbono para un sistema de fijación externa, trabajo de grado de Ingeniería Mecánica, Cali, Universidad del Valle, Cali, Colombia, 2010.

Blanding, D.L., Exact constraint: machine design using kinematic principles. New York: ASME Press, 1999.

ASTM F1541-02, 2015. Standard specification and test methods for external skeletal fixation devices. [online]. Available at: https://compass.astm.org/download/F1541.38465.pdf

Burgers, P.T.P.W., van Riel, M.P.J.M., Vogels, L.M.M., Stam, R., Patka, P. and van Lieshout, E.M.M., Rigidity of unilateral externa fixators – A biomechanical study. Injury, Int. J. Care Injured, 42, pp. 1449-1454. DOI: 10.1016/j.injury.2011.05.024

Iturbe-Arguelles M. del R., Transporte y dispersión de compuestos químicos orgánicos a través del flujo en medios porosos, Tesis (Doctorado en Ingeniería), Universidad Nacional Autónoma de México, México, 1997, 120 P.

Cómo citar

IEEE

[1]
F. Casanova Garcia, A. Carrera Pinzon, A. Leyton, A. Machado Caicedo, y J. J. GarcIa Alvarez, «Development of an easy-to-assemble external fixation system for bone transport», DYNA, vol. 86, n.º 208, pp. 53–59, ene. 2019.

ACM

[1]
Casanova Garcia, F., Carrera Pinzon, A., Leyton, A., Machado Caicedo, A. y GarcIa Alvarez, J.J. 2019. Development of an easy-to-assemble external fixation system for bone transport. DYNA. 86, 208 (ene. 2019), 53–59. DOI:https://doi.org/10.15446/dyna.v86n208.68012.

ACS

(1)
Casanova Garcia, F.; Carrera Pinzon, A.; Leyton, A.; Machado Caicedo, A.; GarcIa Alvarez, J. J. Development of an easy-to-assemble external fixation system for bone transport. DYNA 2019, 86, 53-59.

APA

Casanova Garcia, F., Carrera Pinzon, A., Leyton, A., Machado Caicedo, A. & GarcIa Alvarez, J. J. (2019). Development of an easy-to-assemble external fixation system for bone transport. DYNA, 86(208), 53–59. https://doi.org/10.15446/dyna.v86n208.68012

ABNT

CASANOVA GARCIA, F.; CARRERA PINZON, A.; LEYTON, A.; MACHADO CAICEDO, A.; GARCIA ALVAREZ, J. J. Development of an easy-to-assemble external fixation system for bone transport. DYNA, [S. l.], v. 86, n. 208, p. 53–59, 2019. DOI: 10.15446/dyna.v86n208.68012. Disponível em: https://revistas.unal.edu.co/index.php/dyna/article/view/68012. Acesso em: 18 mar. 2026.

Chicago

Casanova Garcia, Fernando, Andres Carrera Pinzon, Arlex Leyton, Andres Machado Caicedo, y Jose Jaime GarcIa Alvarez. 2019. «Development of an easy-to-assemble external fixation system for bone transport». DYNA 86 (208):53-59. https://doi.org/10.15446/dyna.v86n208.68012.

Harvard

Casanova Garcia, F., Carrera Pinzon, A., Leyton, A., Machado Caicedo, A. y GarcIa Alvarez, J. J. (2019) «Development of an easy-to-assemble external fixation system for bone transport», DYNA, 86(208), pp. 53–59. doi: 10.15446/dyna.v86n208.68012.

MLA

Casanova Garcia, F., A. Carrera Pinzon, A. Leyton, A. Machado Caicedo, y J. J. GarcIa Alvarez. «Development of an easy-to-assemble external fixation system for bone transport». DYNA, vol. 86, n.º 208, enero de 2019, pp. 53-59, doi:10.15446/dyna.v86n208.68012.

Turabian

Casanova Garcia, Fernando, Andres Carrera Pinzon, Arlex Leyton, Andres Machado Caicedo, y Jose Jaime GarcIa Alvarez. «Development of an easy-to-assemble external fixation system for bone transport». DYNA 86, no. 208 (enero 1, 2019): 53–59. Accedido marzo 18, 2026. https://revistas.unal.edu.co/index.php/dyna/article/view/68012.

Vancouver

1.
Casanova Garcia F, Carrera Pinzon A, Leyton A, Machado Caicedo A, GarcIa Alvarez JJ. Development of an easy-to-assemble external fixation system for bone transport. DYNA [Internet]. 1 de enero de 2019 [citado 18 de marzo de 2026];86(208):53-9. Disponible en: https://revistas.unal.edu.co/index.php/dyna/article/view/68012

Descargar cita

CrossRef Cited-by

CrossRef citations1

1. Elmedin Mešić, Nedim Pervan, Adil Muminović, Edvin Rahman, Bakir Muminović. (2025). Stability Assessment of Unilateral External Fixator Configurations for Open Tibial Fractures: An Experimental Study. Applied Sciences, 15(22), p.12327. https://doi.org/10.3390/app152212327.

Dimensions

PlumX

Visitas a la página del resumen del artículo

580

Descargas

Los datos de descargas todavía no están disponibles.