Dosymmetric estimates of 99mTc (MAA) and 133Xe in newborn lungs using Cristy-Eckerman / Segars representations

Estimaciones dosimétricas del 99mTc (MAA) y 133Xe en los pulmones de recién nacidos utilizando las representaciones de Cristy-Eckerman/Segars

DOI:

https://doi.org/10.15446/mo.n64.99290

Palabras clave:

MIRD dosimetry, Cristy-Eckerman /segars representations, lungs (en)
representaciones Cristy-Eckerman/Segars, pulmones, dosimetría MIRD (es)

Descargas

Autores/as

  • Marcial Vasquez-Arteaga Universidad Señor de Sipan, Chiclayo.
  • Héctor Vega-Carrillo Unidad Académica de Estudios Nucleares, Universidad Autónoma de Zacatecas.
  • Gustavo Montalvo-Soberon Universidad Señor de Sipán, Chiclayo.
  • Juan Rivera-Vásquez Universidad Señor de Sipán, Chiclayo.
  • Pedro Jaramillo-Arica Universidad Señor de Sipán, Chiclayo.
  • Marcela Vasquez-Silva Universidad Privada del Norte, Trujillo.
  • Carlos Cabrera-Salvatierra Universidad Privada del Norte, Trujillo.
  • Roberto Rojas-Alegría Universidad Nacional de Trujillo.

Using the Cristy-Eckerman (C-E) / Segars anatomical representations and the MIRD formalism, the Absorbed doses in lungs of newborn patients scanned with radiopharmaceuticals 133Xe (ventilation) and 99mTc (MAA) (perfusion) are estimated. These representations are phantoms used in Monte Carlo calculations to determine specific absorbed fractions, which, associated with the pharmaceutical residence time, determine the absorbed dose. Concerns about the dosimetric impact of using these ventilation / perfusion agents, as well as the use of different phantoms, were explored in newborn patients. When the lungs were scanned with 99mTc (MAA), the relative difference in total dose between the C-E / Segars anatomical representations was 1.0%. When the lungs were scanned with 133Xe, the relative difference in total dose between the anthropomorphic representations of C-E / Segars was 0.5%. Regardless of the radiopharmaceutical used for the pulmonary studies of a newborn patient, the substitution of the C-E representation for that of Segars does not reflect very significant changes in the calculation of the absorbed dose in the lungs, where the greatest dosimetric contribution is its self-dose, which is supplied mainly by the electrons produced during the 99mTc and 133Xe decay.

Usando las representaciones anatómicas de Cristy-Eckerman (C-E) / Segars y el formalismo MIRD, se estiman las dosis absorbidas en pulmones de pacientes recién nacidos explorados con radiofarmacos 133Xe (Ventilación) y   99mTc (MAA) (perfusión). Estas representaciones son fantomas utilizados en los cálculos de Monte Carlo en la determinación de   fracciones absorbidas específicas, que asociadas al tiempo de residencia farmacéutica determinan la dosis absorbida. Preocupaciones sobre el impacto dosimétrico de usar estos agentes ventilación /perfusión, así como el uso de diferentes fantomas, se exploraron en pacientes recién nacidos. Cuando a los pulmones se exploran con   99mTc(MAA), la diferencia relativa en la dosis total entre las representaciones anatómicas de C-E / Segars fue de 1,0 %. Cuando a los pulmones se exploran con 133Xe, la diferencia relativa en la dosis total entre las representaciones antropomórficas de C-E / Segars fue de 0,5 %.  Independientemente del radiofármaco utilizado para los estudios pulmonares de un paciente recién nacido, la sustitución de la representación de C-E por la de Segars no refleja cambios significativos en el cálculo de la dosis absorbida en los pulmones, donde la mayor contribución dosimétrica es su autodosis que es suministrada principalmente por los electrones producidos a lo largo de la desintegración del 99mTc y 133Xe.

Referencias

E. E. Watson, M. G. Stabin, and J. A. Siegel, Med. Phys. 20, 511 (1993).

J. Bevelacqua and B. Resources, Radiation Protection Management 22, 7 (2005).

M. Vasquez-Arteaga, H. Vega-Carrillo, C. Rodriguez-Benites, C. Castillo, H. Rodriguez, R. Chanduvi, and C. Chirinos, MOMENTO 63, 22–33 (2021).

M. Stabin, Internal dose assessment: extrapolation from animal species to human. (Springer, 2004) p. 77.

M. Cristy, Mathematical phantoms representing children at various ages for use in estimates of internal dose (Oak Ridge National Laboratory Rep. ORNL/TM-8377, 1980).

M. Stabin, E. Watson, M. Cristy, J. Ryman, K. Eckerman, J. Davis, D. Marshall, and M. Gehlen, Mathematical models and specific absorbed fractions of photon energy in the nonpregnant adult female and at the end of each trimester of pregnancy (Oak Ridge National Lab. (ORNL), Oak Ridge, 1995).

W. S. Snyder and et al., Report on the Task Group on Reference Man. ICR Publication 23 (Pergamon Press, 1975).

N. Petoussi, M. Zankl, U. Fill, and D. Regulla, Phys. Med. Biol. 47, 89 (2001).

W. Segars, Development of a new dynamic NURBS-based cardiac-torso (NCAT) phantom (Chapel Hill, NC: University of North Carolina, 2001).

J. Valentin, Pergamon. ICRP Publication 89 32, 1 (2002).

T. C. Chao and X. G. Xu, Phys. Med. Biol. 46, 901 (2001).

X. G. Xu, C. Shi, M. G. Stabin, and V. Taranenko, Handbook of Anatomical Models for Radiation Dosimetry - Chapter: Pregnant Female/Fetus Computational Phantoms and the Latest RPI-P Series Representing 3, 6, and 9 Month Gestational Periods (CRC Press, 2009) p. 32.

M. G. Stabin and J. A. Siegel, J. Nucl. Med. 59, 154 (2018).

R. Kramer, J. W. Vieira, H. J. Khoury, E. C. M. Loureiro, F. R. A. Lima, and G. Hoff, IRPA 11 (2004).

M. Vasquez -Arteaga and et al., Appl. Radiat. Isotopes 176, 109888 (2021).

G. Nicolas and et al., J. Nucl. Med. 59, 516 (2018).

K. Eckerman and K. Endo, MIRD: Radionuclide Data and Decay Schemes (The Society of Nuclear Medicine, 2007).

J. Parker and et al., J. Nucl. Med. 37, 1906 (1996).

M. Cristy and K. F. Eckerman, Specific absorbed fractions of energy at various ages from internal photon sources: 1, Methods, Vol. 1 (Oak Ridge National Lab. (ORNL), Oak Ridge, 1987).

M. Cristy and K. F. Eckerman, Specific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn, Vol. 6 (Oak Ridge National Lab. (ORNL), Oak Ridge, 1987).

M. Stabin and J. Siegel, Health Physics 85, 294 (2003).

S. Mattsson and et al., Annals of the ICRP - Publication 128 44(2 suppl), 7 (2015).

H. P. Society, Kinetic models used as the basic for the dose estimates (2013)(Reviewed on March 2021).

H. P. Society, Kinetic models used as the basic for the dose estimates (2013)(Reviewed on March 2021).

M. Ferrari, P. De Marco, D. Origgi, and G. Pedroli, Clin. Transl. Imaging 2, 557 (2014).

J. Parker, R. Coleman, B. Siegel, H. Sostman, K. McKusick, H. Royal, and J. Wilson, J. Nucl. Med. 37, 1906 (1996).

M. Stabin, S. Kost, J. Clark, and D. Pickens, Vanderbilt University, Nashville, TN, USA (2015).

Cómo citar

APA

Vasquez-Arteaga, M., Vega-Carrillo, H., Montalvo-Soberon, G., Rivera-Vásquez, J., Jaramillo-Arica, P., Vasquez-Silva, M., Cabrera-Salvatierra, C. y Rojas-Alegría, R. (2022). Dosymmetric estimates of 99mTc (MAA) and 133Xe in newborn lungs using Cristy-Eckerman / Segars representations. MOMENTO, (64), 54–65. https://doi.org/10.15446/mo.n64.99290

ACM

[1]
Vasquez-Arteaga, M., Vega-Carrillo, H., Montalvo-Soberon, G., Rivera-Vásquez, J., Jaramillo-Arica, P., Vasquez-Silva, M., Cabrera-Salvatierra, C. y Rojas-Alegría, R. 2022. Dosymmetric estimates of 99mTc (MAA) and 133Xe in newborn lungs using Cristy-Eckerman / Segars representations. MOMENTO. 64 (ene. 2022), 54–65. DOI:https://doi.org/10.15446/mo.n64.99290.

ACS

(1)
Vasquez-Arteaga, M.; Vega-Carrillo, H.; Montalvo-Soberon, G.; Rivera-Vásquez, J.; Jaramillo-Arica, P.; Vasquez-Silva, M.; Cabrera-Salvatierra, C.; Rojas-Alegría, R. Dosymmetric estimates of 99mTc (MAA) and 133Xe in newborn lungs using Cristy-Eckerman / Segars representations. Momento 2022, 54-65.

ABNT

VASQUEZ-ARTEAGA, M.; VEGA-CARRILLO, H.; MONTALVO-SOBERON, G.; RIVERA-VÁSQUEZ, J.; JARAMILLO-ARICA, P.; VASQUEZ-SILVA, M.; CABRERA-SALVATIERRA, C.; ROJAS-ALEGRÍA, R. Dosymmetric estimates of 99mTc (MAA) and 133Xe in newborn lungs using Cristy-Eckerman / Segars representations. MOMENTO, [S. l.], n. 64, p. 54–65, 2022. DOI: 10.15446/mo.n64.99290. Disponível em: https://revistas.unal.edu.co/index.php/momento/article/view/99290. Acesso em: 30 jul. 2024.

Chicago

Vasquez-Arteaga, Marcial, Héctor Vega-Carrillo, Gustavo Montalvo-Soberon, Juan Rivera-Vásquez, Pedro Jaramillo-Arica, Marcela Vasquez-Silva, Carlos Cabrera-Salvatierra, y Roberto Rojas-Alegría. 2022. «Dosymmetric estimates of 99mTc (MAA) and 133Xe in newborn lungs using Cristy-Eckerman / Segars representations». MOMENTO, n.º 64 (enero):54-65. https://doi.org/10.15446/mo.n64.99290.

Harvard

Vasquez-Arteaga, M., Vega-Carrillo, H., Montalvo-Soberon, G., Rivera-Vásquez, J., Jaramillo-Arica, P., Vasquez-Silva, M., Cabrera-Salvatierra, C. y Rojas-Alegría, R. (2022) «Dosymmetric estimates of 99mTc (MAA) and 133Xe in newborn lungs using Cristy-Eckerman / Segars representations», MOMENTO, (64), pp. 54–65. doi: 10.15446/mo.n64.99290.

IEEE

[1]
M. Vasquez-Arteaga, «Dosymmetric estimates of 99mTc (MAA) and 133Xe in newborn lungs using Cristy-Eckerman / Segars representations», Momento, n.º 64, pp. 54–65, ene. 2022.

MLA

Vasquez-Arteaga, M., H. Vega-Carrillo, G. Montalvo-Soberon, J. Rivera-Vásquez, P. Jaramillo-Arica, M. Vasquez-Silva, C. Cabrera-Salvatierra, y R. Rojas-Alegría. «Dosymmetric estimates of 99mTc (MAA) and 133Xe in newborn lungs using Cristy-Eckerman / Segars representations». MOMENTO, n.º 64, enero de 2022, pp. 54-65, doi:10.15446/mo.n64.99290.

Turabian

Vasquez-Arteaga, Marcial, Héctor Vega-Carrillo, Gustavo Montalvo-Soberon, Juan Rivera-Vásquez, Pedro Jaramillo-Arica, Marcela Vasquez-Silva, Carlos Cabrera-Salvatierra, y Roberto Rojas-Alegría. «Dosymmetric estimates of 99mTc (MAA) and 133Xe in newborn lungs using Cristy-Eckerman / Segars representations». MOMENTO, no. 64 (enero 5, 2022): 54–65. Accedido julio 30, 2024. https://revistas.unal.edu.co/index.php/momento/article/view/99290.

Vancouver

1.
Vasquez-Arteaga M, Vega-Carrillo H, Montalvo-Soberon G, Rivera-Vásquez J, Jaramillo-Arica P, Vasquez-Silva M, Cabrera-Salvatierra C, Rojas-Alegría R. Dosymmetric estimates of 99mTc (MAA) and 133Xe in newborn lungs using Cristy-Eckerman / Segars representations. Momento [Internet]. 5 de enero de 2022 [citado 30 de julio de 2024];(64):54-65. Disponible en: https://revistas.unal.edu.co/index.php/momento/article/view/99290

Descargar cita

CrossRef Cited-by

CrossRef citations1

1. Marcial V. Vasquez, Héctor R. Vega, Santos L. Acuña, Huber E. Rodriguez, Marcela A. Vasquez, Hipólito F. Flores, Santos M. Tantaquispe. (2024). RADIOPHARMACEUTICAL RENAL DOSIMETRY USING SNYDER / CRISTY-ECKERMAN / SEGARS ANTHROPOMORPHIC REPRESENTATIONS. MOMENTO, (68), p.1. https://doi.org/10.15446/mo.n68.102552.

Dimensions

PlumX

Visitas a la página del resumen del artículo

542

Descargas

Los datos de descargas todavía no están disponibles.