Publicado

2011-01-01

Disconnection and Connection of CCVTs Applying Live Line Working Methodology

Palabras clave:

Live working methodologies and procedures, transient analysis for live line working procedures, Potential Transformers (PT), Capacitive Coupling Voltage Transformer (CCVT) (es)

Autores/as

  • IVAN ALBERTO SANIN RINCON
The present document describes the results reached by the analysis about the procedures to disconnect and connect CCVTs with LLW technics. Additionally, the document describes the application of these results in maintenance activities on San Bernardino 230kV and Caño Limón 230kV substations. The first one was realized to make electrical diagnostics tests on Busbar’s CCVTs without turn off the substation. The second one was realized to replace a CCVT in one pole of Banadía-Caño Limón’s overhead line bay.

Cómo citar

APA

SANIN RINCON, I. A. (2011). Disconnection and Connection of CCVTs Applying Live Line Working Methodology. Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, 6. https://revistas.unal.edu.co/index.php/SICEL/article/view/21884

ACM

[1]
SANIN RINCON, I.A. 2011. Disconnection and Connection of CCVTs Applying Live Line Working Methodology. Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL. 6, (ene. 2011).

ACS

(1)
SANIN RINCON, I. A. Disconnection and Connection of CCVTs Applying Live Line Working Methodology. SICEL 2011, 6.

ABNT

SANIN RINCON, I. A. Disconnection and Connection of CCVTs Applying Live Line Working Methodology. Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, [S. l.], v. 6, 2011. Disponível em: https://revistas.unal.edu.co/index.php/SICEL/article/view/21884. Acesso em: 10 feb. 2025.

Chicago

SANIN RINCON, IVAN ALBERTO. 2011. «Disconnection and Connection of CCVTs Applying Live Line Working Methodology». Simposio Internacional Sobre La Calidad De La Energía Eléctrica - SICEL 6 (enero). https://revistas.unal.edu.co/index.php/SICEL/article/view/21884.

Harvard

SANIN RINCON, I. A. (2011) «Disconnection and Connection of CCVTs Applying Live Line Working Methodology», Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, 6. Disponible en: https://revistas.unal.edu.co/index.php/SICEL/article/view/21884 (Accedido: 10 febrero 2025).

IEEE

[1]
I. A. SANIN RINCON, «Disconnection and Connection of CCVTs Applying Live Line Working Methodology», SICEL, vol. 6, ene. 2011.

MLA

SANIN RINCON, I. A. «Disconnection and Connection of CCVTs Applying Live Line Working Methodology». Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, vol. 6, enero de 2011, https://revistas.unal.edu.co/index.php/SICEL/article/view/21884.

Turabian

SANIN RINCON, IVAN ALBERTO. «Disconnection and Connection of CCVTs Applying Live Line Working Methodology». Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL 6 (enero 1, 2011). Accedido febrero 10, 2025. https://revistas.unal.edu.co/index.php/SICEL/article/view/21884.

Vancouver

1.
SANIN RINCON IA. Disconnection and Connection of CCVTs Applying Live Line Working Methodology. SICEL [Internet]. 1 de enero de 2011 [citado 10 de febrero de 2025];6. Disponible en: https://revistas.unal.edu.co/index.php/SICEL/article/view/21884

Descargar cita

Visitas a la página del resumen del artículo

200

Descargas

Los datos de descargas todavía no están disponibles.