In this paper a portable high voltage impulse generator is presented, which is designed and built with an insulation up to 20 kV. This design is based on a previous work in which we developed a simulation software for standard waves.  Commercial components and low-cost components were used in this work. However, these particular elements are not generally used for high voltage applications.  The impulse generators used in the industry and laboratories are usually expensive, they are built to withstand extra high voltage, and they are big, making them impossible to transport. Otherwise, the proposed generator is portable, which allows to make test on devices that cannot be moved from its location. The results obtained with the proposed impulse generator were satisfactory in terms of time and waveforms, against other commercial impulse generators and against the standard impulse wave simulator.

 In this paper a portable high voltage impulse generator is presented, which is designed and built with an insulation up to 20 kV. This design is based on a previous work in which we developed a simulation software for standard waves.  Commercial components and low-cost components were used in this work. However, these particular elements are not generally used for high voltage applications.  The impulse generators used in the industry and laboratories are usually expensive, they are built to withstand extra high voltage, and they are big, making them impossible to transport. Otherwise, the proposed generator is portable, which allows to make test on devices that cannot be moved from its location. The results obtained with the proposed impulse generator were satisfactory in terms of time and waveforms, against other commercial impulse generators and against the standard impulse wave simulator.

 

Cómo citar

APA

Gómez Arango, S. (2011). Portable High Voltage Impulse Generator. Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, 6. https://revistas.unal.edu.co/index.php/SICEL/article/view/22642

ACM

[1]
Gómez Arango, S. 2011. Portable High Voltage Impulse Generator. Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL. 6, (ene. 2011).

ACS

(1)
Gómez Arango, S. Portable High Voltage Impulse Generator. SICEL 2011, 6.

ABNT

GÓMEZ ARANGO, S. Portable High Voltage Impulse Generator. Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, [S. l.], v. 6, 2011. Disponível em: https://revistas.unal.edu.co/index.php/SICEL/article/view/22642. Acesso em: 16 feb. 2025.

Chicago

Gómez Arango, Santiago. 2011. «Portable High Voltage Impulse Generator». Simposio Internacional Sobre La Calidad De La Energía Eléctrica - SICEL 6 (enero). https://revistas.unal.edu.co/index.php/SICEL/article/view/22642.

Harvard

Gómez Arango, S. (2011) «Portable High Voltage Impulse Generator», Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, 6. Disponible en: https://revistas.unal.edu.co/index.php/SICEL/article/view/22642 (Accedido: 16 febrero 2025).

IEEE

[1]
S. Gómez Arango, «Portable High Voltage Impulse Generator», SICEL, vol. 6, ene. 2011.

MLA

Gómez Arango, S. «Portable High Voltage Impulse Generator». Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, vol. 6, enero de 2011, https://revistas.unal.edu.co/index.php/SICEL/article/view/22642.

Turabian

Gómez Arango, Santiago. «Portable High Voltage Impulse Generator». Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL 6 (enero 1, 2011). Accedido febrero 16, 2025. https://revistas.unal.edu.co/index.php/SICEL/article/view/22642.

Vancouver

1.
Gómez Arango S. Portable High Voltage Impulse Generator. SICEL [Internet]. 1 de enero de 2011 [citado 16 de febrero de 2025];6. Disponible en: https://revistas.unal.edu.co/index.php/SICEL/article/view/22642

Descargar cita

Visitas a la página del resumen del artículo

247

Descargas

Los datos de descargas todavía no están disponibles.