This paper present an evaluation of over voltages in low-voltage LV installation in buildings in cases of direct lightning strikes to overhead medium voltage lines. The study considered typical power systems with low – and medium voltage surge arresters. The calculation have been performed using the EMTP-ATP
Cómo citar
APA
Sowa, A. y Wiater, J. (2003). EVALUATION OF ARRESTER’S PROTECTION LEVELS DURING LIGHTNING STRIKES TO OVERHEAD MEDIUM VOLTAGE LINES. Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, 2. https://revistas.unal.edu.co/index.php/SICEL/article/view/377
ACM
[1]
Sowa, A. y Wiater, J. 2003. EVALUATION OF ARRESTER’S PROTECTION LEVELS DURING LIGHTNING STRIKES TO OVERHEAD MEDIUM VOLTAGE LINES. Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL. 2, (ene. 2003).
ACS
(1)
Sowa, A.; Wiater, J. EVALUATION OF ARRESTER’S PROTECTION LEVELS DURING LIGHTNING STRIKES TO OVERHEAD MEDIUM VOLTAGE LINES. SICEL 2003, 2.
ABNT
SOWA, A.; WIATER, J. EVALUATION OF ARRESTER’S PROTECTION LEVELS DURING LIGHTNING STRIKES TO OVERHEAD MEDIUM VOLTAGE LINES. Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, [S. l.], v. 2, 2003. Disponível em: https://revistas.unal.edu.co/index.php/SICEL/article/view/377. Acesso em: 14 feb. 2025.
Chicago
Sowa, Andrzej, y JarosÅ‚aw Wiater. 2003. «EVALUATION OF ARRESTER’S PROTECTION LEVELS DURING LIGHTNING STRIKES TO OVERHEAD MEDIUM VOLTAGE LINES». Simposio Internacional Sobre La Calidad De La Energía Eléctrica - SICEL 2 (enero). https://revistas.unal.edu.co/index.php/SICEL/article/view/377.
Harvard
Sowa, A. y Wiater, J. (2003) «EVALUATION OF ARRESTER’S PROTECTION LEVELS DURING LIGHTNING STRIKES TO OVERHEAD MEDIUM VOLTAGE LINES», Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, 2. Disponible en: https://revistas.unal.edu.co/index.php/SICEL/article/view/377 (Accedido: 14 febrero 2025).
IEEE
[1]
A. Sowa y J. Wiater, «EVALUATION OF ARRESTER’S PROTECTION LEVELS DURING LIGHTNING STRIKES TO OVERHEAD MEDIUM VOLTAGE LINES», SICEL, vol. 2, ene. 2003.
MLA
Sowa, A., y J. Wiater. «EVALUATION OF ARRESTER’S PROTECTION LEVELS DURING LIGHTNING STRIKES TO OVERHEAD MEDIUM VOLTAGE LINES». Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, vol. 2, enero de 2003, https://revistas.unal.edu.co/index.php/SICEL/article/view/377.
Turabian
Sowa, Andrzej, y JarosÅ‚aw Wiater. «EVALUATION OF ARRESTER’S PROTECTION LEVELS DURING LIGHTNING STRIKES TO OVERHEAD MEDIUM VOLTAGE LINES». Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL 2 (enero 1, 2003). Accedido febrero 14, 2025. https://revistas.unal.edu.co/index.php/SICEL/article/view/377.
Vancouver
1.
Sowa A, Wiater J. EVALUATION OF ARRESTER’S PROTECTION LEVELS DURING LIGHTNING STRIKES TO OVERHEAD MEDIUM VOLTAGE LINES. SICEL [Internet]. 1 de enero de 2003 [citado 14 de febrero de 2025];2. Disponible en: https://revistas.unal.edu.co/index.php/SICEL/article/view/377
Descargar cita
Visitas a la página del resumen del artículo
97
Descargas
Los datos de descargas todavía no están disponibles.