Publicado

2013-01-01

Impact of Twelve-pulse D-STATCOM on Voltage Sags Mitigation in Distribution Systems

Palabras clave:

Voltage Sags, D-STATCOM, ATP/EMTP, Sags Mitigation, Power Quality, Simulations (es)

Descargas

Autores/as

  • Herbert Enrique Rojas Cubides Universidad Distrital Francisco José de Caldas
This paper presents a study about response of distribution system under presence of voltage sags implementing distribution static compensator (D-STATCOM). From simulations, it analyzes the modified IEEE-13 distribution system identifying those nodes that highly affect the voltage profiles in the distribution system using a method of fault positions (critical nodes). It presents D-STATCOM model based on twelve-pulse inverter, taking advantage of the available elements and the TACS-MODELS tool from ATP/EMTP. Further, the performance of the distribution system using D-STATCOM in several cases is analyzed, showing that this device is a good alternative for sags mitigation. In addition, the relation between the injected D-STATCOM reactive power, the type of sag and the location of affected nodes is considered.

Cómo citar

APA

Rojas Cubides, H. E. (2013). Impact of Twelve-pulse D-STATCOM on Voltage Sags Mitigation in Distribution Systems. Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, 7. https://revistas.unal.edu.co/index.php/SICEL/article/view/38810

ACM

[1]
Rojas Cubides, H.E. 2013. Impact of Twelve-pulse D-STATCOM on Voltage Sags Mitigation in Distribution Systems. Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL. 7, (ene. 2013).

ACS

(1)
Rojas Cubides, H. E. Impact of Twelve-pulse D-STATCOM on Voltage Sags Mitigation in Distribution Systems. SICEL 2013, 7.

ABNT

ROJAS CUBIDES, H. E. Impact of Twelve-pulse D-STATCOM on Voltage Sags Mitigation in Distribution Systems. Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, [S. l.], v. 7, 2013. Disponível em: https://revistas.unal.edu.co/index.php/SICEL/article/view/38810. Acesso em: 7 feb. 2025.

Chicago

Rojas Cubides, Herbert Enrique. 2013. «Impact of Twelve-pulse D-STATCOM on Voltage Sags Mitigation in Distribution Systems». Simposio Internacional Sobre La Calidad De La Energía Eléctrica - SICEL 7 (enero). https://revistas.unal.edu.co/index.php/SICEL/article/view/38810.

Harvard

Rojas Cubides, H. E. (2013) «Impact of Twelve-pulse D-STATCOM on Voltage Sags Mitigation in Distribution Systems», Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, 7. Disponible en: https://revistas.unal.edu.co/index.php/SICEL/article/view/38810 (Accedido: 7 febrero 2025).

IEEE

[1]
H. E. Rojas Cubides, «Impact of Twelve-pulse D-STATCOM on Voltage Sags Mitigation in Distribution Systems», SICEL, vol. 7, ene. 2013.

MLA

Rojas Cubides, H. E. «Impact of Twelve-pulse D-STATCOM on Voltage Sags Mitigation in Distribution Systems». Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, vol. 7, enero de 2013, https://revistas.unal.edu.co/index.php/SICEL/article/view/38810.

Turabian

Rojas Cubides, Herbert Enrique. «Impact of Twelve-pulse D-STATCOM on Voltage Sags Mitigation in Distribution Systems». Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL 7 (enero 1, 2013). Accedido febrero 7, 2025. https://revistas.unal.edu.co/index.php/SICEL/article/view/38810.

Vancouver

1.
Rojas Cubides HE. Impact of Twelve-pulse D-STATCOM on Voltage Sags Mitigation in Distribution Systems. SICEL [Internet]. 1 de enero de 2013 [citado 7 de febrero de 2025];7. Disponible en: https://revistas.unal.edu.co/index.php/SICEL/article/view/38810

Descargar cita

Visitas a la página del resumen del artículo

205

Descargas

Los datos de descargas todavía no están disponibles.