Comparative Study of the performance of a hybrid PVT panel with water as coolant under two different weather conditions
Palabras clave:
Hybrid photovoltaic thermal solar collector PVT, thermosyphon, electrical yield, thermal energy, primary energy savings. (es)
Descargas
This paper describes the performance comparison of a PVT solar collector in thermosyphon closed loop mode under two different weather conditions, fully cloudy and partially cloudy scenarios. The PVT electrical and thermal performance were evaluated and compared with a same unmodified factory PV panel for both scenarios. The PVT performance was evaluated by electrical, thermal and primary energy savings efficiencies. It was found that the PVT total efficiency increased 7.28 % under the partially cloudy scenario, due mainly to the thermal energy gain. At the fully cloudy scenario this improvement was 2.12 %, which indicates that for places where present mostly cloudy conditions, the PVT enhancement will not be so significant.
Visitas a la página del resumen del artículo
338
Descargas
Los datos de descarga aún no están disponibles.
Cómo citar
Arias Forero, H. E., Cabrera Fuertes, J. H., & Hernández Mora, J. A. (2015). Comparative Study of the performance of a hybrid PVT panel with water as coolant under two different weather conditions. Simposio Internacional Sobre La Calidad De La Energía Eléctrica - SICEL, 8. https://revistas.unal.edu.co/index.php/SICEL/article/view/51636