This work evaluates, through a case study of a regional transmission system of the country, the potential of increase of capability that would have the use of the dynamic thermal rating, DTR. In the first part, the traditional (conservative) procedures and criteria used in the design of transmission lines and the background and successful experiences of DTR are reviewed worldwide. The work continues proposing alternative schemes, of dynamic thermal rating, that integrate sotfware, communications and technologies for the capture of electromechanical and meteorological variables applicable to the country's transmission sector. After identifying the best scheme, the work continues with the focus on the application of the conductor thermal model (IEEE Standard 738) [1] for a 115kV transmission line of a regional system of the center of the country. In the final part, a baseline or reference case is define and operational scenarios (with changes in meteorological variables) are proposed in order to execute simulations with the thermal model and to identify the potential of increase that could be achieved, for this line, with the use of these new technologies.
Cómo citar
APA
Correa Salazar, L. H. (2017). Assessment of the Potential for Increased Capability in Electric Lines by the Use of DTR (Dynamic Thermal Rating) Case Study for a Regional Transmission System. Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, 9. https://revistas.unal.edu.co/index.php/SICEL/article/view/63715
ACM
[1]
Correa Salazar, L.H. 2017. Assessment of the Potential for Increased Capability in Electric Lines by the Use of DTR (Dynamic Thermal Rating) Case Study for a Regional Transmission System. Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL. 9, (ene. 2017).
ACS
(1)
Correa Salazar, L. H. Assessment of the Potential for Increased Capability in Electric Lines by the Use of DTR (Dynamic Thermal Rating) Case Study for a Regional Transmission System. SICEL 2017, 9.
ABNT
CORREA SALAZAR, L. H. Assessment of the Potential for Increased Capability in Electric Lines by the Use of DTR (Dynamic Thermal Rating) Case Study for a Regional Transmission System. Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, [S. l.], v. 9, 2017. Disponível em: https://revistas.unal.edu.co/index.php/SICEL/article/view/63715. Acesso em: 13 feb. 2025.
Chicago
Correa Salazar, Luis Hernando. 2017. «Assessment of the Potential for Increased Capability in Electric Lines by the Use of DTR (Dynamic Thermal Rating) Case Study for a Regional Transmission System». Simposio Internacional Sobre La Calidad De La Energía Eléctrica - SICEL 9 (enero). https://revistas.unal.edu.co/index.php/SICEL/article/view/63715.
Harvard
Correa Salazar, L. H. (2017) «Assessment of the Potential for Increased Capability in Electric Lines by the Use of DTR (Dynamic Thermal Rating) Case Study for a Regional Transmission System», Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, 9. Disponible en: https://revistas.unal.edu.co/index.php/SICEL/article/view/63715 (Accedido: 13 febrero 2025).
IEEE
[1]
L. H. Correa Salazar, «Assessment of the Potential for Increased Capability in Electric Lines by the Use of DTR (Dynamic Thermal Rating) Case Study for a Regional Transmission System», SICEL, vol. 9, ene. 2017.
MLA
Correa Salazar, L. H. «Assessment of the Potential for Increased Capability in Electric Lines by the Use of DTR (Dynamic Thermal Rating) Case Study for a Regional Transmission System». Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL, vol. 9, enero de 2017, https://revistas.unal.edu.co/index.php/SICEL/article/view/63715.
Turabian
Correa Salazar, Luis Hernando. «Assessment of the Potential for Increased Capability in Electric Lines by the Use of DTR (Dynamic Thermal Rating) Case Study for a Regional Transmission System». Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL 9 (enero 1, 2017). Accedido febrero 13, 2025. https://revistas.unal.edu.co/index.php/SICEL/article/view/63715.
Vancouver
1.
Correa Salazar LH. Assessment of the Potential for Increased Capability in Electric Lines by the Use of DTR (Dynamic Thermal Rating) Case Study for a Regional Transmission System. SICEL [Internet]. 1 de enero de 2017 [citado 13 de febrero de 2025];9. Disponible en: https://revistas.unal.edu.co/index.php/SICEL/article/view/63715
Descargar cita
Visitas a la página del resumen del artículo
215
Descargas
Los datos de descargas todavía no están disponibles.
Licencia
Derechos de autor 2018 Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL