Publicado

2018-09-01

Avaliação teórica do uso do oxihidróxido de vanádio trivalente na detecção eletroquímica de nandrolona

The theoretical evaluation of the use of trivalent vanadium oxyhydroxide in the electrochemical determination of nandrolone

DOI:

https://doi.org/10.15446/rcciquifa.v47n3.77372

Palabras clave:

elétrodos quimicamente modificados, nandrolona, oxihidróxido de vanádio (III), eletrorredução catódica, estado estacionário estável (pt)
chemically modified electrodes, nandrolone, vanadium (III) oxyhydroxide, cathodic electrochemical reduction, stable steady-state (en)

Autores/as

  • Volodymyr Tkach Universidade Nacional de Chernivtsi, 58012, Rua de Kotsyubyns’ky, 2, Chernivtsi, Ucrânia.
  • Yana G. Ivanushko Universidade Nacional de Chernivtsi, 58012, Rua de Kotsyubyns’ky, 2, Chernivtsi, Ucrânia.
  • Svitlana M. Lukanova Universidade Nacional de Chernivtsi, 58012, Rua de Kotsyubyns’ky, 2, Chernivtsi, Ucrânia.
  • Sílvio C. de Oliveira Universidade Federal de Mato Grosso do Sul, Av. Sen. Felinto. Müller, 1555, C/P. 549, 79074- 460, Campo Grande, MS, Brasil.
  • Fauze J. Anaissi Universidade Estadual do Centro-Oeste, Setor de Ciências Exatas e da Terra, Departamento de Química, Laboratório de Materiais e Compostos Inorgânicos, Rua Simeão Varela de Sá, 03, 85040-080, Guarapuava, PR, Brasil.
  • Nataliia M. Storoshchuk Universidade Nacional de Chernivtsi, 58012, Rua de Kotsyubyns’ky, 2, Chernivtsi, Ucrânia.
  • Petro I. Yagodynets´ Universidade Nacional de Chernivtsi, 58012, Rua de Kotsyubyns’ky, 2, Chernivtsi, Ucrânia.

Pela primeira vez foi descrito um caso interessante de uso do oxihidróxido de vanádio trivalente (VO(OH)) como modificador de elétrodo na detecção eletroquímica de nandrolona. Foi mostrado que o oxihidróxido de vanádio pode ser um modificador eficiente para a detecção de nandrolona, mas, ao contrário da maioria dos casos de uso de oxihidróxido de cobalto, composto parecido, o processo é catódico e dá-se em meio moderadamente ácido a neutro. O comportamento oscilatório, no sistema, é possível apenas por causa das influências do processo da eletrorredução de vanádio tetravalente em trivalente na dupla camada elétrica.

An interesting case of the use of trivalent vanadium oxyhydroxide (VO(OH)) as an electrode modifier for nandrolone electrochemical determination has been described for the first time. It was shown that vanadium (III) oxyhydroxide may be an efficient electrode modifier for nandrolone determination, but, contrarily to the majority of the cases of the use of cobalt (III) oxyhydroxide, which is a relative compound, the process is cathodic and it is realized in moderately acid solutions, tending to neutral. The oscillatory behavior in the system is possible, due to the influence of the electrochemical reduction of tetravalent vanadium to trivalent in double electric layer.

Referencias

A.J. Higgins, From ancient Greece to modern Athens: 3000 years of doping in competition horses, J. Vet. Pharm. Ther., 29, 4 (2006).

J. Clarke, The doping of racehorses, Med. Leg. J., 30, 180 (1962).

“Ratsch: The Encyclopedia of Psychoactive Plants: Ethnopharmacology and its Applications”, Ed. Park Street Press, Rochester, 2005.

R. Kumar, Doping Competing against doping, Br. J. Sport. Med., 44, 1 (2010).

Parliament of Austria, Where in the world is doping a crime? (doping in sports pt.6), https://www.aph.gov.au/About_Parliament/Parliamentary_Departments/Parliamentary_Library/FlagPost/2013/April/Where_in_the_world_is_doping_a_crime_doping_in_sports_pt_6

Wikipedia, Nandrolone sulfate sodium, https://ipfs.io/ipfs/QmXoypizjW3Wkn-FiJnKLwHCnL72vedxjQkDDP1mXWo6uco/wiki/Nandrolone_sulfate_sodium.html

Open Chemistry Database, Nandrolone hydrogen sulfate, https://pubchem.ncbi.nlm.nih.gov/compound/3085201#section=Top

Index Nominum International Drug Directory, Taylor & Francis, January 2000, pp. 716-717, ISBN 978-3-88763-075-1

Drugs and and supplement, https://www.sdrugs.com/?c=ing&s=nandrolone%20sodium%20sulfate

Nandrolone Side Effects, https://www.drugs.com/sfx/nandrolone-side-effects.html

K.L. Johansen, K. Mulligan, M. Schambelan, Anabolic effects of nandrolone decanoate in patients receiving dialysis: a randomized controlled trial, JAMA, 281, 1275 (1999).

J. Mukherjee, A. Das, U.S. Chakrabarty et al., Development and validation of RP HPLC method to determine nandrolone phenylpropionate in different pharmaceutical formulation, Acta Pol. Pharm., 68, 155 (2011).

R.N. Goyal, V.K. Gupta, N. Bachcheti, Fullerene-C60-modified electrode as a sensitive voltammetric sensor for detection of nandrolone--an anabolic steroid used in doping, Anal. Chim. Acta, 597, 82 (2007).

D.M.W. Arrigan, “Electrochemical Strategies in Detection Sciences”, RSC Edition, London, 2016.

W. Jin, Y. Zheng, X. Chen, Adsorption Voltammetry of nandrolone phenylpropionate, Electroanal., 9, 498 (1997).

Y. Zhang, X. Jing, Hydrothermal synthesis and supercapacitor electrode of low crystallinity VOOH hollow spheres with pseudocapacitance in aqueous solution, Mat. Lett., 205, 1 (2017).

O. Stadnik, “Synthesis electrochemical and photoelectrochemical properties of the oxide-hydroxide compounds of cobalt”, Diss. Kand. Chim. N.-Kyiv., 2011.

O. Stadnik, N. Ivanova, Y. Boldyrev, Int. Electrochem. Soc. Meeting. Abstract, 2240, http://ma.ecsdl.org/content/MA201002/38/2240.full.pdf

V. Tkach, Ya.G. Ivanushko, S.M. Lukanova et al., The theoretical evaluation for the possibility of CoO(OH)-assisted electroanalytical pyriproxyfen detection in water, Appl. J. Envir. Eng. Sci., 3, 90 (2017).

V. Tkach, S.C. de Oliveira, F.J. Anaissi et al., The Possibility of the use of CoO(OH) as an electrode modifier for hydrazine detection and its mathematical evaluation, Anal. Bioanal. Electrochem., 8, 557 (2016).

V. Tkach, Ya. Ivanushko, S.C. de Oliveira et al., The theoretical evaluation of the posiibility of CoO(OH)-assisted omeprazole electrochemical detection, Anal. Bioanal. Electrochem., 8, 749 (2016).

Cómo citar

APA

Tkach, V., Ivanushko, Y. G., Lukanova, S. M., de Oliveira, S. C., Anaissi, F. J., Storoshchuk, N. M. & Yagodynets´, P. I. (2018). Avaliação teórica do uso do oxihidróxido de vanádio trivalente na detecção eletroquímica de nandrolona. Revista Colombiana de Ciencias Químico-Farmacéuticas, 47(3), 400–409. https://doi.org/10.15446/rcciquifa.v47n3.77372

ACM

[1]
Tkach, V., Ivanushko, Y.G., Lukanova, S.M., de Oliveira, S.C., Anaissi, F.J., Storoshchuk, N.M. y Yagodynets´, P.I. 2018. Avaliação teórica do uso do oxihidróxido de vanádio trivalente na detecção eletroquímica de nandrolona. Revista Colombiana de Ciencias Químico-Farmacéuticas. 47, 3 (sep. 2018), 400–409. DOI:https://doi.org/10.15446/rcciquifa.v47n3.77372.

ACS

(1)
Tkach, V.; Ivanushko, Y. G.; Lukanova, S. M.; de Oliveira, S. C.; Anaissi, F. J.; Storoshchuk, N. M.; Yagodynets´, P. I. Avaliação teórica do uso do oxihidróxido de vanádio trivalente na detecção eletroquímica de nandrolona. Rev. Colomb. Cienc. Quím. Farm. 2018, 47, 400-409.

ABNT

TKACH, V.; IVANUSHKO, Y. G.; LUKANOVA, S. M.; DE OLIVEIRA, S. C.; ANAISSI, F. J.; STOROSHCHUK, N. M.; YAGODYNETS´, P. I. Avaliação teórica do uso do oxihidróxido de vanádio trivalente na detecção eletroquímica de nandrolona. Revista Colombiana de Ciencias Químico-Farmacéuticas, [S. l.], v. 47, n. 3, p. 400–409, 2018. DOI: 10.15446/rcciquifa.v47n3.77372. Disponível em: https://revistas.unal.edu.co/index.php/rccquifa/article/view/77372. Acesso em: 19 mar. 2026.

Chicago

Tkach, Volodymyr, Yana G. Ivanushko, Svitlana M. Lukanova, Sílvio C. de Oliveira, Fauze J. Anaissi, Nataliia M. Storoshchuk, y Petro I. Yagodynets´. 2018. «Avaliação teórica do uso do oxihidróxido de vanádio trivalente na detecção eletroquímica de nandrolona». Revista Colombiana De Ciencias Químico-Farmacéuticas 47 (3):400-409. https://doi.org/10.15446/rcciquifa.v47n3.77372.

Harvard

Tkach, V., Ivanushko, Y. G., Lukanova, S. M., de Oliveira, S. C., Anaissi, F. J., Storoshchuk, N. M. y Yagodynets´, P. I. (2018) «Avaliação teórica do uso do oxihidróxido de vanádio trivalente na detecção eletroquímica de nandrolona», Revista Colombiana de Ciencias Químico-Farmacéuticas, 47(3), pp. 400–409. doi: 10.15446/rcciquifa.v47n3.77372.

IEEE

[1]
V. Tkach, «Avaliação teórica do uso do oxihidróxido de vanádio trivalente na detecção eletroquímica de nandrolona», Rev. Colomb. Cienc. Quím. Farm., vol. 47, n.º 3, pp. 400–409, sep. 2018.

MLA

Tkach, V., Y. G. Ivanushko, S. M. Lukanova, S. C. de Oliveira, F. J. Anaissi, N. M. Storoshchuk, y P. I. Yagodynets´. «Avaliação teórica do uso do oxihidróxido de vanádio trivalente na detecção eletroquímica de nandrolona». Revista Colombiana de Ciencias Químico-Farmacéuticas, vol. 47, n.º 3, septiembre de 2018, pp. 400-9, doi:10.15446/rcciquifa.v47n3.77372.

Turabian

Tkach, Volodymyr, Yana G. Ivanushko, Svitlana M. Lukanova, Sílvio C. de Oliveira, Fauze J. Anaissi, Nataliia M. Storoshchuk, y Petro I. Yagodynets´. «Avaliação teórica do uso do oxihidróxido de vanádio trivalente na detecção eletroquímica de nandrolona». Revista Colombiana de Ciencias Químico-Farmacéuticas 47, no. 3 (septiembre 1, 2018): 400–409. Accedido marzo 19, 2026. https://revistas.unal.edu.co/index.php/rccquifa/article/view/77372.

Vancouver

1.
Tkach V, Ivanushko YG, Lukanova SM, de Oliveira SC, Anaissi FJ, Storoshchuk NM, Yagodynets´ PI. Avaliação teórica do uso do oxihidróxido de vanádio trivalente na detecção eletroquímica de nandrolona. Rev. Colomb. Cienc. Quím. Farm. [Internet]. 1 de septiembre de 2018 [citado 19 de marzo de 2026];47(3):400-9. Disponible en: https://revistas.unal.edu.co/index.php/rccquifa/article/view/77372

Descargar cita

CrossRef Cited-by

CrossRef citations0

Dimensions

PlumX

Visitas a la página del resumen del artículo

488

Descargas

Los datos de descargas todavía no están disponibles.