Experimental evaluation of the strut-and-tie method applied to low-rise concrete walls
Evaluación experimental del método de puntales y tensores aplicado a muros de concreto de baja altura
Keywords:
concrete wall, strut-and-tie model, cellular concrete, shaking table test, shear strength degradation, loading rate (en)muros de concreto, modelo de puntales y tensores, concreto celular, ensayos en mesa vibradora, degradación de resistencia a cortante, velocidad de aplicación de carga (es)
The strut-and-tie method (S-T) is a practical tool for the seismic design of reinforced concrete elements. Experimental and analytical research with low-rise concrete walls was carried out for assessing the S-T method proposed by the current ACI-318 building code. Four specimens designed to fail during shear and shaking table tests were included in the experimental programme. The variables studied consisted of the type of concrete (normal and cellular weight), the amount of steel web (0.125% and 0.25%) and the type of web reinforcement against shear (corrugated bars and welded wire mesh). Wall properties were typical of low-rise housing in Mexico. When the calculated shear strength was compared with the measured one it was found that the S-T method proposed by the ACI-318 building code suitably estimated the shear capacity of the models being studied. However, the walls shear failure mode, loading rate, the number of cycles and the cumulative energy dissipated would noticeably affect the degradation in strength of low-rise, reinforced concrete walls.
El método de puntales y tensores (P-T) es una herramienta práctica para el diseño sísmico de elementos de concreto reforzado. Con el propósito de evaluar el método de P-T propuesto en el reglamento vigente ACI-318 se llevó a cabo una investigación experimental y analítica con muros de concreto de baja altura. En el programa experimental se incluyeron cuatro especímenes diseñados para fallar por cortante, los cuales se ensayaron dinámicamente en mesa vibradora. Las variables estudiadas fueron el tipo de concreto (peso normal y celular), la cuantía de acero (0,125 y 0,25%) y el tipo de refuerzo a cortante en el alma de los muros (barras corrugadas y malla de alambre soldado). Las propiedades de los muros fueron típicas de viviendas mexicanas de baja altura. Cuando se comparó la resistencia calculada con la resistencia medida se encontró que el método de puntales y tensores del reglamento ACI-318 hace una estimación adecuada de la capacidad a cortante de los muros estudiados. Sin embargo, el modo de falla a cortante del muro, la velocidad de aplicación de carga, el número de ciclos y la energía disipada acumulada, pueden afectar significativamente la degradación de resistencia de muros de concreto reforzado de baja altura.
Downloads
References
Alcocer, S., Uribe, C., Monolithic and cyclic behavior of deep beams designed using strut-and-tie models., ACI Structural Journal, Vol. 105, No. 3, 2008, pp. 327-337.
American Concrete Institute - ACI., Building code requirements for structural concrete (ACI 318-08) and commentary (ACI 318R-08)., Farmington Hills, MI, USA, 2008.
Carrillo, J., Evaluación del comportamiento a cortante de muros de concreto por medio de ensayes dinámicos., Tesis doctoral, Universidad Nacional Autónoma de México, 2010.
Carrillo, J., Estimación de los periodos naturales de vibración de viviendas de baja altura con muros de concreto., Revista Ciencia e Ingeniería Neogranadadina, Vol. 19, No. 1, 2009, pp. 39-54.
Carrillo, J., Alcocer, S., Shaking table test of RC shear walls with openings., 9th US National and 10th Canadian Conference on Earthquake Engineering, Toronto, Canadá, 2010a, Art. 072.
Carrillo, J., Alcocer, S., Improved external device for a mass-carrying sliding system for shaking table testing., Journal of Earthquake Engineering and Structural Dynamics, 2010b.
Carrillo, J., Alcocer, S., Shaking table test of low-rise concrete walls for housing., 14th World Conference on Earthquake Engineering, Beijing, China, 2008, Art. 12-01-0011.
Flores, L., Alcocer, S., Carrillo, J., Sánchez, A., Uribe, R., Ponce, A., Ensaye de muros de concreto con diferente relación de aspecto y bajas cuantías de refuerzo para uso en vivienda., XVI Congreso Nacional de Ingeniería Sísmica, Ixtapa-Zihuatanejo,
Guerrero, México, 2007, Tema XI, Art. 2. Gulec, C., Whittaker, A., Stojadinovic, B., Shear strength of squat rectangular reinforced concrete walls., ACI Structural Journal, Vol. 105, No. 4, 2008, pp. 488-497.
Hwang, S., Fang, W., Lee, H., Yu, H., Analytical model for predicting shear strength of squat walls., Journal of Structural Engineering - ASCE, Vol. 127, No. 1, 2001, pp. 43-50.
Ordaz, M., Arboleda, J., Singh, S., A Scheme of random summation of an empirical Green´ s function to estimate ground motions from future large earthquakes., Bulletin of the Seismological Society of America, Vol. 85, No. 6, 1995, pp. 1635-1647.
Reineck, K., Examples for the design of structural concrete with strut-and-tie models., Publicación SP-208, American Concrete Institute, Detroit, 2002, pp. 244.
Sánchez, A., Comportamiento sísmico de viviendas construidas con muros de concreto., Tesis doctoral, Universidad Nacional Autónoma de México, 2010.
Santoyo, M., Singh, S., Mikumo, T., Source process and stress change associated with the 11 January, 1997 (Mw = 7.1) Michoacán - Mexico - inslab earthquake., Geofísica internacional, Vol. 44, No. 4, 2005, pp. 317-330.
Siao, W., Shear strength of short reinforced concrete walls, corbels and deep beams., ACI Structural Journal, Vol. 91, No. 2, 1994, pp. 123-132.
Tomazevic, M., Velechovsky, T., Some aspects of testing small-scale masonry building model on simple earthquake simulator., Journal of Earthquake Engineering and structural Dynamics, Vol. 21, No. 11, 1992, pp. 945-963.
License
Copyright (c) 2010 Julian Carrillo León, Sergio M. Alcocer

This work is licensed under a Creative Commons Attribution 4.0 International License.
The authors or holders of the copyright for each article hereby confer exclusive, limited and free authorization on the Universidad Nacional de Colombia's journal Ingeniería e Investigación concerning the aforementioned article which, once it has been evaluated and approved, will be submitted for publication, in line with the following items:
1. The version which has been corrected according to the evaluators' suggestions will be remitted and it will be made clear whether the aforementioned article is an unedited document regarding which the rights to be authorized are held and total responsibility will be assumed by the authors for the content of the work being submitted to Ingeniería e Investigación, the Universidad Nacional de Colombia and third-parties;
2. The authorization conferred on the journal will come into force from the date on which it is included in the respective volume and issue of Ingeniería e Investigación in the Open Journal Systems and on the journal's main page (https://revistas.unal.edu.co/index.php/ingeinv), as well as in different databases and indices in which the publication is indexed;
3. The authors authorize the Universidad Nacional de Colombia's journal Ingeniería e Investigación to publish the document in whatever required format (printed, digital, electronic or whatsoever known or yet to be discovered form) and authorize Ingeniería e Investigación to include the work in any indices and/or search engines deemed necessary for promoting its diffusion;
4. The authors accept that such authorization is given free of charge and they, therefore, waive any right to receive remuneration from the publication, distribution, public communication and any use whatsoever referred to in the terms of this authorization.