Development of a system for detecting and locating damaged insulator strings with signals collected at substations
Desarrollo de un sistema para detección y localización de cadenas de aisladores dañadas a partir de señales registradas en subestaciones
DOI:
https://doi.org/10.15446/ing.investig.v35n1.41832Keywords:
insulator strings, transmission line, neural network, current transformer (en)cadenas de aisladores, línea de transmisión, redes neuronales, transformador de corriente (es)
This paper presents a novel technique for remotely identifying and locating of damaged insulator strings based on an analysis of noise signals recorded on the ground connection of current transformers installed on transmission line substations. Damaged insulators usually present electrical surface activity. Surface and corona discharges may result in the generation of high frequency signals that can travel through the transmission line conductors, which are recorded by a data acquisition system. Each signal generated by the surface or corona discharge has a unique signature. This signature changes according to the position of the source, i.e., the damaged string along the line, which enables the association between the signal signature and the location of the string along the line. A method proposed to achieve this association is discussed in this paper as well as the tools and tests carried out during its development. An innovative way for capacitive coupling, which reduce detection system implementation costs is presented
Dimensions
PlumX
Article abstract page views
Downloads
How to Cite
License
Copyright (c) 2015 Renato Massoni Capelini

This work is licensed under a Creative Commons Attribution 4.0 International License.
The authors or holders of the copyright for each article hereby confer exclusive, limited and free authorization on the Universidad Nacional de Colombia's journal Ingeniería e Investigación concerning the aforementioned article which, once it has been evaluated and approved, will be submitted for publication, in line with the following items:
1. The version which has been corrected according to the evaluators' suggestions will be remitted and it will be made clear whether the aforementioned article is an unedited document regarding which the rights to be authorized are held and total responsibility will be assumed by the authors for the content of the work being submitted to Ingeniería e Investigación, the Universidad Nacional de Colombia and third-parties;
2. The authorization conferred on the journal will come into force from the date on which it is included in the respective volume and issue of Ingeniería e Investigación in the Open Journal Systems and on the journal's main page (https://revistas.unal.edu.co/index.php/ingeinv), as well as in different databases and indices in which the publication is indexed;
3. The authors authorize the Universidad Nacional de Colombia's journal Ingeniería e Investigación to publish the document in whatever required format (printed, digital, electronic or whatsoever known or yet to be discovered form) and authorize Ingeniería e Investigación to include the work in any indices and/or search engines deemed necessary for promoting its diffusion;
4. The authors accept that such authorization is given free of charge and they, therefore, waive any right to receive remuneration from the publication, distribution, public communication and any use whatsoever referred to in the terms of this authorization.