Evaluation of internal curing effects on concrete
Evaluación de los efectos del curado interno del concreto
DOI:
https://doi.org/10.15446/ing.investig.v39n2.76505Keywords:
Absorption, Chloride resistance, Contraction, Internal curing, Lightweight aggregates, Lightweight concrete, Slum, Superabsorbent polymers (SAP) (en)Absorción, Agregados ligeros, Asentamiento, Concreto ligero, Contracción, Curado interno, Polímeros superabsorbentes SAP, Resistencia a cloruros (es)
The objective of the present research was the evaluation of some fresh and hardenedstate properties of concretes, in which coarse aggregates were partially replaced by lightweight ones previously saturated, in percentages of 15% and 25 %. The lightweight aggregates were calcined clays and crushed clay bricks. In parallel, the effect of an internal curing agent composed of superabsorbent polymers (SAP) was evaluated. The properties evaluated in the fresh and hardenedstate of concretes with a/c of 0,30 were: slum, air content, density, compression resistance, modulus of elasticity, initial superficial absorption and chlorine resistance. Results showed the efficiency of crushed clay bricks as internal curing, as well as the need for deeper research on the use of the evaluated lightweight aggregate as internal curing aggregate in concrete. Results indicate that the crushed clay bricks and the internal curing agent fulfill the behavior expected, in terms of strength and durability. However, the evaluated lightweight aggregate produces a reduction in the resistance and durability of the concrete. The observed behavior in strength and durability is especially variable for the age of 180 days, compared with conventional concretes.
La presente investigación tuvo como objetivo la evaluación de algunas propiedades en estado fresco y endurecido de concretos, en los cuales se realizaron reemplazos parciales de agregado grueso por agregados ligeros previamente saturados, en porcentajes de 15 % y 25 %. Los agregados ligeros fueron arcillas calcinadas y ladrillos de arcilla triturados. Paralelamente, se evaluó el efecto de un agente de curado interno compuesto por polímeros súper absorbentes (SAP). Las propiedades evaluadas en estado fresco y endurecido de los concretos con una relación a/c de 0,30 fueron: asentamiento, contenido de aire, densidad, resistencia a compresión, módulo de elasticidad, tasa de absorción superficial inicial y resistencia a cloruros. Los resultados mostraron la eficiencia de los ladrillos de arcilla triturados y del agente curador interno, así como también la necesidad de realizar investigación más profunda en la utilización del agregado ligero evaluado como agregado de curado interno en el concreto. La investigación prueba que La mampostería de arcilla triturada cumple el comportamiento esperado en un agente de curado interno desde el punto de vista de durabilidad y resistencia, mientras que el agregado ligero evaluado produjo una reducción en la resistencia y la durabilidad del concreto. El comportamiento observado en cuestión de resistencia y durabilidad es especialmente cambiante para la edad de 180 días, en comparación con los concretos convencionales.
References
ACI Committee 211 (1991). Standard Practice for Selecting Proportions for Normal, Heavyweight, and Mass Concrete (ACI 211.191). Farmington Hills, MI: American Concrete Institute.
ACI Committee 308 (2008). Guide to Curing Concrete (ACI 308 R01). Farmington Hills, MI: American Concrete Institute.
ACI Committee 308213 (2013). Report on Internally Cured Concrete Using Prewetted Absorptive Lightweight
Aggregate (ACI 308213 R13).Farmington Hills, MI: American Concrete Institute.
AIS (2010). Reglamento colombiano de construcción sismo resistente (NSR10). Bogotá: Asociación Colombiana de Ingeniería Sísmica,
ASTM C157/C157M17 (2017). Standard Test Method for Length Change of Hardened HydraulicCement Mortar and Concrete. West Conshohocken, PA: ASTM International. DOI: 10.1520/C0157_C0157M17
ASTM C158513 (2013). Standard Test Method for Measurement of Rate of Absorption of Water by HydraulicCement Concretes. West Conshohocken, PA: ASTM International. DOI: 10.1520/C158513
ASTM C1202 (2012). Standard Test Method for Electrical Indication of Concrete’s Ability to Resist Chloride Ion Penetration. West Conshohocken, PA: ASTM International. DOI: 10.1520/C120219
ASTM C469/C469M (2014). Standard Test Method for Static Modulus of Elasticity and Poisson’s Ratio of Concrete in Compression. West Conshohocken, PA: ASTM International. DOI: 10.1520/C0469
Bentz, D. P., and Weiss, W. J. (2011). Internal Curing: A 2010 StateoftheArt Review (NIST Interagency/Internal Report (NISTIR) – 7765). Retrieved from: DOI: 10.6028/NIST.IR.7765
Castro, J., Keiser, L., Golias, M., and Weiss, J. (2011). Absorption and desorption properties of fine lightweight aggregate for application to internally cured concrete mixtures. Cement and Concrete Composites, 33(10), 1001–1008. DOI: 10.1016/j.cemconcomp.2011.07.006
Dayalan, J., and Buellah, M. (2014). Internal Curing of Concrete Using Prewetted Light Weight Aggregates. International Journal of Innovative Research in Science, Engineering and Technology, 3(3), 1055410560. Retrieved from: http://www.ijirset.com/upload/2014/march/95_Internal.pdf
ICONTEC. (1994). NTC 4022 – Masa unitaria de concreto liviano estructural. Bogotá: ICONTEC.
ICONTEC. (1997). NTC 4045 – Agregados livianos para concreto estructural. Bogotá: ICONTEC.
ICONTEC. (2005). NTC 3494 – Determinación de la retención de agua de los materiales utilizados para el curado del concreto, NTC. Bogotá: ICONTEC.
Kovler, K. and Jensen, M.O. (Eds.). (2007) Internal Curing of Concrete StateoftheArt Report of RILEM Technical Committee 196ICC. Bagneux : RILEM publications.
Neville, A. M. M., and Brooks, J. J. (2010). Concrete Technology. Harlow, England, New York: Prentice Hall. DOI: 10.1016/03601323(76)900093
Shafigh, P., Jumaat, M. Z., Mahmud, H. Bin, and Hamid, N. A. A. (2012). Lightweight concrete made from crushed oil palm shell: Tensile strength and effect of initial curing on compressive strength. Construction and Building Materials, 27(1),252–258. DOI: 10.1016/j.conbuildmat.2011.07.051
Saffar, D. M. Al, Saad, A. J. K. Al, and Tayeh, B. A. (2019). Effect of internal curing on behavior of highperformance concrete: An overview. Case Studies in Construction Materials, 10(e00229). DOI: 10.1016/j.cscm.2019.e00229
How to Cite
APA
ACM
ACS
ABNT
Chicago
Harvard
IEEE
MLA
Turabian
Vancouver
Download Citation
CrossRef Cited-by
1. Javier Coronel-Gaviro, Virginia Yagüe-Jiménez, José Luis Blanco-Murillo. (2022). Radiofrequency Absorbance as a Novel Concentration Indicator in Sucrose Aqueous Solutions. Ingeniería e Investigación, 43(1), p.e94695. https://doi.org/10.15446/ing.investig.94695.
2. Hamidah Mohd Saman, Norhaliza Hamzah. (2025). Self Curing Concrete. SpringerBriefs in Applied Sciences and Technology. , p.1. https://doi.org/10.1007/978-981-96-2964-0_1.
3. Sócrates Pedro Muñoz-Pérez, Felipe Mimbela-Orderique, Ernesto Dante Rodriguez-Lafitte. (2021). Uso de ladrillos triturados en concreto: una revisión literaria. Revista Politécnica, 17(34), p.82. https://doi.org/10.33571/rpolitec.v17n34a6.
Dimensions
PlumX
Article abstract page views
Downloads
License
Copyright (c) 2019 Nancy Torres Castellanos, Sergio David Rodríguez-Torres

This work is licensed under a Creative Commons Attribution 4.0 International License.
The authors or holders of the copyright for each article hereby confer exclusive, limited and free authorization on the Universidad Nacional de Colombia's journal Ingeniería e Investigación concerning the aforementioned article which, once it has been evaluated and approved, will be submitted for publication, in line with the following items:
1. The version which has been corrected according to the evaluators' suggestions will be remitted and it will be made clear whether the aforementioned article is an unedited document regarding which the rights to be authorized are held and total responsibility will be assumed by the authors for the content of the work being submitted to Ingeniería e Investigación, the Universidad Nacional de Colombia and third-parties;
2. The authorization conferred on the journal will come into force from the date on which it is included in the respective volume and issue of Ingeniería e Investigación in the Open Journal Systems and on the journal's main page (https://revistas.unal.edu.co/index.php/ingeinv), as well as in different databases and indices in which the publication is indexed;
3. The authors authorize the Universidad Nacional de Colombia's journal Ingeniería e Investigación to publish the document in whatever required format (printed, digital, electronic or whatsoever known or yet to be discovered form) and authorize Ingeniería e Investigación to include the work in any indices and/or search engines deemed necessary for promoting its diffusion;
4. The authors accept that such authorization is given free of charge and they, therefore, waive any right to receive remuneration from the publication, distribution, public communication and any use whatsoever referred to in the terms of this authorization.