Starting-up and operating a full-scale activated sludge system for slaughterhouse wastewater
Arranque y operación a escala real de un sistema de tratamiento de lodos activos para aguas residuales de matadero
DOI:
https://doi.org/10.15446/ing.investig.v29n2.15161Keywords:
activated sludge, treatment, slaughterhouse wastewater (en)lodos activos, tratamiento, aguas residuales de matadero (es)
Downloads
This research was conducted at the Frigofrontera wastewater plant which has screening, de-sanding, a grease trap and sedimentation as its primary treatment system, an activated sludge recirculation reactor for secondary treatment and a descending bed filter for tertiary treatment. Average treated flow is 1.38 L/s; the activated sludge reactor has a 144 m3 volume and 2-day cell retention time. Reactor oxygen levels are guaranteed by injecting air using high-efficiency equipment. Basic wastewater concentration parameters are: 5,242.13 mg / L BOD5; 9,039.75 mg / L COD and 2,972.69 mg / L SS. The treatment plant was started up during February 2006 and has been in constant operation since then. It has achieved 89.73% five-day biological oxygen demand (BOD5), 89.03% chemical oxygen demand (COD) and 94.09% soluble solid (SS) load removal efficiency. The sludge produced by the process is treated by screening where the solids are separated from wastewater. The liquid is returned to the sedimenters and solids are composted.
La investigación se desarrolló en la planta de tratamiento de aguas residuales de la empresa Frigorífico Frigofrontera Ltda., la cual está constituida por un sistema de tratamiento primario que incluye cribado, desarenado, trampa de grasas y sedimentación, un reactor de lodo activo con recirculación para el tratamiento secundario y un filtro descendente como tratamiento terciario. El caudal tratado en promedio es de 1,38 L/s; el reactor de lodo activo tiene un volumen de 144 m3, un tiempo de retención celular de 2 días. Los niveles de oxígeno en el reactor son garantizados mediante la inyección de aire con equipos de alta eficiencia. Las concentraciones de los parámetros básicos del agua residual son: 5242,13 mg/L de DBO5; 9039,75 mg/L de DQO y 2972,69 mg/L de SS. El arranque de la planta de tratamiento se realizó durante el mes de febrero de 2006 y a partir de esa fecha ha operado continuamente, obteniéndose una eficiencia de remoción en carga de DBO5 de 89,73 %, 89,03 de DQO y 94,09 de SS. Los lodos generados por el proceso son tratados mediante cribado donde se separan los sólidos del agua residual. El líquido es retornado a los sedimentadotes y el sólido es compostado.
References
American Public Health Association (APHA)., American Water Works Association (AWWA)., Water Environment Federation (WEF), Standard Methods for The Examination of Water and Wastewater, 20 ed., Washington D.C., APHA-WEF, 1998, pp. 1195.
Benavides, L., Evaluación de la planta de tratamiento de aguas residuales de la Central de Sacrificio de Túquerres (Nariño)., Trabajo de grado presentado a la Universidad Nacional para optar al título de especialista en Ingeniería Ambiental, 2006.
Finamore, C., Blanco, H., López, E., Constantes Cinéticas de un sistema de lodos activos a escala de laboratorio., Memorias XXVII Congresso Interamericano de Engenharia Sanitaria Ambiental,1999
Hincapié, S. J., Hincapié, Y. R., Mataderos municipales su administración y operación., Universidad Distrital Francisco José de Caldas, 1997, pp.110.
Li, J., Healy, M. G., Zhan, X., Rodgers, M., Effect of Aeration Rate on Nutrient Removal from Slaughterhouse Wastewater in Intermittently Aerated Sequencing Batch Reactors Water., Air & Soil Pollution, Vol 192, No 1-4, 2008, pp.251–261.
López, A., De la Barrera-Fraire, J., Vallejo, R., Acoplamiento de un sistema anaerobio/aerobio para el tratamiento de agua residual de rastro., Revista Latinoamericana de Recursos Naturales, Vol. 4, No 2, 2008, pp.269-277.
Massé D. I, Masse L., Characterization of wastewater from hog slaughterhouses in Eastern Canada and evaluation of their in-plant wastewater., Canadian Agricultural Engineering, Vol. 42, No. 3, 2000, pp. 139-146.
Metcalff & Eddy., Ingeniería de aguas residuales., Tratamiento, vertido y reutilización, Vol. I y II., España, Editorial Mc Graw- Hill, 1995, pp. 235.
Minambiente. Ministerio del Medio Ambiente., Guía ambiental para las plantas de beneficio de ganado., Bogotá, 2002.
Mitta, G. S., Treatment of wastewater from abattoirs before land application a review., Bioresource Tecnnology, Vol. 97, No. 9, Jun, 2006, pp. 1119-1135.
Oliveira, R. C., Barbosa, O., Giordano, G., Proposta de um método de cálculo do tempo desedimentação no tratamento de esgotos por lodos ativados em bateladas., Engenharia Sanitária e Ambiental – ABES, Vol.10, No. 3, 2005, pp. 185-193
Pedott, C., Peruzzolo, M., Di Luccio, M., Qualitative study of organic compounds in wastewaters of a swine slaughterhouse., Environmental Monitoring and Assessment, Vol. 116, No. 1-3, 2006, pp.103-110.
Parada, P. A., Sánchez, C. A., Diseño de un sistema de tratamiento para el manejo de los residuos sólidos generados por la planta de tratamiento de aguas residuales (PTAR) del Frigorífico La Frontera Ltda., Municipio Villa del Rosario (Norte de Santander)., Proyecto de Grado presentado a la Universidad Francisco de Paula Santander, para optar al título de Ingeniero de Producción Biotecnológica, 2006.
Pabón, S. L., Urbina, N. A., Diseño e Implementación de un Sistema de Tratamiento de Aguas Residuales para el Frigorífico La Frontera Ltda., Villa del Rosario (Norte de Santander)., Proyecto de Grado presentado a la Universidad Francisco de Paula Santander, para optar al título de Ingeniero de Producción Biotecnológica, 2005.
Pabón, L., Arranque y operación de un sistema de tratamiento de lodos activos para las aguas residuales del Frigorifico La Frontera Ltda., informe final joven investigadora COLCIENCIAS-UFPS-FRIGOFRONTERA, 2008.
Romero, J. A., Tratamiento de Aguas Residuales., Editorial Escuela Colombiana de Ingeniería, Bogotá, 1998.
Takahashi, S., Evaluación de alternativa de tratamiento de aguas residuales utilizando la tecnología de lodos activados., Proyecto de Grado, presentado a la Universidad del Valle para optar al título de Ingeniera Ambiental, 1996.
Urbina, N., Pabón, L., Suárez, J., Tratamiento biológico de aguas residuales de Matadero. Caso: Frigorífico La Frontera Ltda, Villa Del Rosario Norte De Santander., Revista Respuestas UFPS, Año 11, No. 2, 2006, pp. 39-50.
Von Sperling, M., Dimensionamento de lodos ativados por batelada utilizando os princípios da teoria do fluxo de sólidos., Engenharia Sanitária e Ambiental – ABES, Vol. 6, No. 3, 2001, pp.147-156.
Dimensions
PlumX
Article abstract page views
Downloads
How to Cite
License
Copyright (c) 2009 Sandra Liliana Pabón, John Hermógenes Suárez Gélvez

This work is licensed under a Creative Commons Attribution 4.0 International License.
The authors or holders of the copyright for each article hereby confer exclusive, limited and free authorization on the Universidad Nacional de Colombia's journal Ingeniería e Investigación concerning the aforementioned article which, once it has been evaluated and approved, will be submitted for publication, in line with the following items:
1. The version which has been corrected according to the evaluators' suggestions will be remitted and it will be made clear whether the aforementioned article is an unedited document regarding which the rights to be authorized are held and total responsibility will be assumed by the authors for the content of the work being submitted to Ingeniería e Investigación, the Universidad Nacional de Colombia and third-parties;
2. The authorization conferred on the journal will come into force from the date on which it is included in the respective volume and issue of Ingeniería e Investigación in the Open Journal Systems and on the journal's main page (https://revistas.unal.edu.co/index.php/ingeinv), as well as in different databases and indices in which the publication is indexed;
3. The authors authorize the Universidad Nacional de Colombia's journal Ingeniería e Investigación to publish the document in whatever required format (printed, digital, electronic or whatsoever known or yet to be discovered form) and authorize Ingeniería e Investigación to include the work in any indices and/or search engines deemed necessary for promoting its diffusion;
4. The authors accept that such authorization is given free of charge and they, therefore, waive any right to receive remuneration from the publication, distribution, public communication and any use whatsoever referred to in the terms of this authorization.