Publicado

2021-04-01

Characterization of ocular biometric parameters in Colombian candidates for cataract surgery

Caracterización de los parámetros biométricos oculares de pacientes colombianos candidatos a cirugía de catarata

DOI:

https://doi.org/10.15446/revfacmed.v69n2.78870

Palabras clave:

Biometry, Cataract, Astigmatism, Axial Length, Eye, Lenses, Intraocular, Cataract Extraction (en)
Biometría, Catarata, Astigmatismo, Longitud axial del ojo, Lentes intraoculares, Extracción de catarata (es)

Autores/as

  • Jose David Paulo Universidad de Antioquia - Facultad de Medicina - Departamento Cirugía - Medellín - Colombia. | Universidad Pontificia Bolivariana - Facultad de Medicina - Medellín - Colombia. | Hospital Pablo Tobón Uribe - Unidad de Investigaciones y Docencia - Medellín - Colombia. | Clínica de Oftalmología - Organización Santa Lucía - Medellín - Colombia. https://orcid.org/0000-0002-5470-4279
  • Luis Santiago Hurtado Clínica de Oftalmología - Organización Santa Lucía - Medellín - Colombia. https://orcid.org/0000-0001-5293-2633
  • Jorge Hernando Donado-Gómez Universidad Pontificia Bolivariana - Facultad de Medicina - Medellín - Colombia. | Hospital Pablo Tobón Uribe - Unidad de Investigaciones y Docencia - Medellín - Colombia. https://orcid.org/0000-0001-8581-2267
  • Natalia González-Lopera Universidad Pontificia Bolivariana - Facultad de Medicina - Medellín - Colombia. https://orcid.org/0000-0001-6327-0073

Introduction: Intraocular lens (IOL) power calculation, based on ocular biometry, is a determinant for the success of cataract surgery.

Objectives: To characterize the ocular biometric parameters of Colombian patients over 40 years of age who are candidates for cataract surgery and to determine the prevalence of the 9 clinical conditions proposed by Holladay according to the interaction between axial length (AL) and anterior chamber depth (ACD).

Materials and methods: Analytical cross-sectional study. The ocular biometry results of 781 patients (831 eyes) who were going to be taken to cataract surgery between January 2014 and January 2015 in Medellín, Colombia, were reviewed. After applying exclusion criteria, 716 eyes were included for analysis. Data on age, sex, AL, keratometry (flat keratometry (K1) and steep keratometry (K2)), ACD and white-to-white distance were collected. Results are presented using descriptive statistics.

Results: Most eyes were from women (62.3%). The mean values of AL, K1 and ACD were 23.37±1.51mm, 43.52±2.06 and 3.03mm±0.41, respectively. Mean AL in men was 23.62±1.37mm, and in women, 23.21±1.67mm. The highest mean AL was observed in patients <50 years old (23.84±2.41) and the lowest in patients ≥80 years old (22.96±1.03 mm). Regarding eye size according to their AL, 90.5% were normal, 4.89% long, and 4.61% short.

Conclusions: 85% of the participants had normal biometric parameters. For the remaining 15%, it is necessary to take some precautions when calculating IOL power, such as using fourth-generation formulas like Holladay 2 in long eyes, because the same refractive behavior will not be obtained using traditional prediction formulas in these patients. Furthermore, according to the Holladay classification, excluding normal eyes, the most frequent eyes were those with myopia and axial hyperopia.

Introducción. El cálculo del poder del lente intraocular (LIO), basado en la biometría ocular, es un factor determinante del éxito en la cirugía de catarata.

Objetivos. Caracterizar los parámetros biométricos oculares de pacientes colombianos mayores de 40 años candidatos a cirugía de catarata y determinar la prevalencia de las 9 condiciones clínicas propuestas por Holladay según la interacción entre longitud axial (LA) y profundidad de la cámara anterior (ACD).

Materiales y métodos. Estudio transversal analítico. Se revisaron los resultados de biometría ocular de 781 pacientes (831 ojos) que iban a ser sometidos a cirugía de cataratas entre enero de 2014 y enero de 2015 en Medellín, Colombia. Luego de aplicar los criterios de exclusión, se incluyeron 716 ojos para análisis. Se recolectaron datos sobre edad, sexo, LA, queratometría (queratometría más plana (K1), queratometría más curva (K2)), ACD y distancia blanco-blanco. Los resultados se presentan mediante estadística descriptiva.

Resultados. La mayoría de ojos eran de mujeres (62.3%). Las medias de LA, K1 y ACD fueron 23.37±1.51mm, 43.52±2.06 y 3.03±0.41mm, respectivamente. La media de LA en hombres fue 23.62±1.37mm, y en mujeres, 23.21±1.67mm. La media más alta de LA se observó en pacientes <50 años (23.84±2.41mm) y la más baja en aquellos ≥80 años (22.96±1.03mm). Respecto al tamaño de los ojos según su LA, 90.5% fueron normales; 4.89%, largos, y 4.61%, cortos.

Conclusiones. 85% de los participantes tuvo parámetros biométricos normales. Para el 15% restante es necesario tomar precauciones al calcular el poder del LIO, tales como el uso de fórmulas de cuarta generación como la Holladay 2 en ojos largos, pues en estos pacientes no se obtendrá el mismo comportamiento refractivo con las fórmulas de predicción tradicionales. Además, según la clasificación de Holladay, excluyendo a los ojos normales, los ojos más frecuentes fueron aquellos con miopía e hipermetropía axial.

Referencias

Furtado JM, Lansingh VC, Carter MJ, Milanese MF, Peña BN, Ghersi HA et al. Causes of blindness and visual impairment in Latin America. Surv Ophthalmol. 2012 ;57(2):149-77. https://doi.org/bvbpvh.

Coleman AL. How Big Data Informs Us About Cataract Surgery: The LXXII Edward Jackson Memorial Lecture. Am J Ophthalmol. 2015;160(6):1091-103. https://doi.org/f7z8rg.

Lundström M, Barry P, Henry Y, Rosen P, Stenevi U. Visual outcome of cataract surgery; study from the European Registry of Quality Outcomes for Cataract and Refractive Surgery. J Cataract Refract Surg. 2013;39(5):673-9. https://doi.org/f2h46r.

Apple DJ, Escobar-Gomez M, Zaugg B, Kleinmann G, Borkenstein AF. Modern cataract surgery: unfinished business and unanswered questions. Surv Ophthalmol. 2011;56(Suppl 6):S3-53. https://doi.org/c4fpd4.

Lee AC, Qazi MA, Pepose JS. Biometry and intraocular lens power calculation. Curr Opin Ophthalmol. 2008;19(1):13-7. https://doi.org/dqt26c.

Fotedar R, Wang JJ, Burlutsky G, Morgan IG, Rose K, Wong TY, et al. Distribution of axial length and ocular biometry measured using partial coherence laser interferometry (IOL Master) in an older white population. Ophthalmology. 2010;117(3):417-23. https://doi.org/bdm728.

Wong TY, Foster PJ, Ng TP, Tielsch JM, Johnson GJ, Seah SK. Variations in ocular biometry in an adult Chinese population in Singapore: the Tanjong Pagar Survey. Invest Ophthalmol Vis Sci. 2001;42(1):73–80.

Zhang L, He X, Qu X, You X, Wang B, Shi H, et al. Refraction and Ocular Biometry of Preschool Children in Shanghai, China. J Ophthalmol. 2018;2018:5205946. https://doi.org/gdfm7f.

Hilkert SM, Parness-Yossifon R, Mets-Halgrimson R, Mets MB. Ocular biometry and determinants of refractive error in a founder population of European ancestry. Ophthalmic Genet. 2018;39(1):11-6. https://doi.org/f3h9.

Warrier S, Wu HM, Newland HS, Muecke J, Selva D, Aung T, et al. Ocular biometry and determinants of refractive error in rural Myanmar: the Meiktila Eye Study. Br J Ophthalmol. 2008;92(12):1591-4. https://doi.org/dk3q3j.

Shufelt C, Fraser-Bell S, Ying-Lai M, Torres M, Varma R. Refractive error, ocular biometry, and lens opalescence in an adult population: the Los Angeles Latino Eye Study. Invest Ophthalmol Vis Sci. 2005;46(12):4450-60. https://doi.org/fv65jh.

Wickremasinghe S, Foster PJ, Uranchimeg D, Lee PS, Devereux JG, Alsbirk PH, et al. Ocular biometry and refraction in Mongolian adults. Invest Ophthalmol Vis Sci. 2004;45(3):776-83. https://doi.org/bs75jf.

Fontes BM, Fontes BM, Castro E. Intraocular lens power calculation by measuring axial length with partial optical coherence and ultrasonic biometry. Arq Bras Oftalmol. 2011;74(3):166-70. https://doi.org/f3jb.

Ferrer-Blasco T, Esteve-Taboada JJ., Domínguez-Vicent A, Aloy MA, Adsuara JE, Mimica P, et al. Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography. Arq Bras Oftalmol. 2019; 82(2):129-35. https://doi.org/gh56tq.

Araque R, Bastidas SM, Van Heyl L. Estudio biométrico ocular en una población adulta del Hospital de San José. Rev Soc Col Oftalmol. 2008;41:751-7.

Pereira GC, Allemann N. Biometria ocular, erro refrativo e sua relação com a estatura, idade, sexo e escolaridade em adultos brasileiros. Arq. Bras. Oftalmol. 2007;70(3):487-93. https://doi.org/cg2r7t.

Morales-Avalos JM, Torres-Moreno AJ. Estudio biométrico ocular en una población adulta del estado de Sinaloa. Rev Mex Oftalmol. 2016;90(1):14-7. https://doi.org/f3nf.

Holladay JT, Gills JP, Leidlein J, Cherchio M. Achieving emmetropia in extremely short eyes with two piggyback posterior chamber intraocular lenses. Ophthalmology. 1996;103(7):1118-23. https://doi.org/f3mn.

World Medical Association (WMA). WMA Declaration of Helsinki – Ethical principles for medical research involving human subjects. Fortaleza: 64th WMA General Assembly; 2013.

Colombia. Ministerio de Salud. Resolución 8430 de 1993 (octubre 4): Por la cual se establecen las normas científicas, técnicas y administrativas para la investigación en salud. Bogotá D.C.; octubre 4 de 1993.

Fysteinsson T, Jonasson F, Arnarsson A, Sasaki H, Sasaki K. Relationships between ocular dimensions and adult stature among participants in the Reykjavik Eye Study. Acta Ophthalmol Scand. 2005;83(6):734-8. https://doi.org/dh6fs6.

Cui Y, Meng Q, Guo H, Zeng J, Zhang H, Zhang G, et al. Biometry and corneal astigmatism in cataract surgery candidates from Southern China. J Cataract Refract Surg. 2014;40(10):1661-9. https://doi.org/f2vd65.

Quigley HA, Broman AT. The number of people with glaucoma worldwide in 2010 and 2020. Br J Ophthalmol. 2006;90(3):262-7. https://doi.org/dwjvw4.

Ridley H. Intra-ocular acrylic lenses; a recent development in the surgery of cataract. Br J Ophthalmol. 1952;36(3):113-22. https://doi.org/fqw2dj.

Sahin A, Hamrah P. Clinically relevant biometry. Curr Opin Ophthalmol. 2012;23(1):47-53. https://doi.org/fqsmsq.

Aristodemou P, Knox-Cartwright NE, Sparrow JM, Johnston RL. Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry. J Cataract Refract Surg. 2011;37(1):63-71. https://doi.org/czgsdz.

Dimensions

PlumX

Visitas a la página del resumen del artículo

1005

Descargas

Los datos de descarga aún no están disponibles.

Cómo citar

Caracterización de los parámetros biométricos oculares de pacientes colombianos candidatos a cirugía de catarata. (2021). Revista De La Facultad De Medicina, 69(2), e78870. https://doi.org/10.15446/revfacmed.v69n2.78870