Publicado

2019-07-01

False-positive fourth-generation HIV test associated with autoimmune hemolytic anemia. Case report

Falso positivo de prueba para VIH de cuarta generación asociado a anemia hemolítica autoinmune. Reporte de caso

DOI:

https://doi.org/10.15446/cr.v5n2.78532

Palabras clave:

Enzyme-Linked Immunosorbent Assay, HIV, Anemia, Hemolytic. (en)
Ensayo de inmunoadsorción enzimática, Serodiagnóstico del sida, Anemia hemolítica. (es)

Autores/as

Introduction: The fourth-generation ELISA human immunodeficiency virus (HIV) screening test has a high sensitivity and specificity >99% to detect both antigens and antibodies. Estimates are that only 0.5% yield false positive results.

Case description: 61-year-old female patient with a clinical picture consisting of malaise, unquantified fever, asthenia and adynamia. Laboratory tests revealed anemia, so a Coombs test was performed, obtaining a positive result along with other findings of mixed autoimmune hemolytic anemia. Two fourth-generation ELISA HIV screening tests were performed obtaining positive results. Given the national recommendations on the diagnosis of HIV infection, a viral load was performed, which turned out to be negative, so the result was considered a false positive.

Discussion: Clinical and biological factors are related to false positive results. There are descriptions about autoimmunity phenomena, such as systemic lupus erythematosus or autoimmune hemolytic anemia, with few cases in older adults.

Conclusions: Rapid tests have changed the diagnosis of HIV infection worldwide; however, like any other diagnostic test, they may yield false positive results with differential diagnoses, including autoimmune hemolytic anemia.

Introducción. La prueba de tamizaje para virus de la inmunodeficiencia humana (VIH) con ELISA de cuarta generación tiene gran sensibilidad y una especificidad >99% para detectar tanto antígenos como anticuerpos. Se estima que solo el 0.5% son falsos positivos.

Presentación del caso. Paciente femenino de 61 años con cuadro clínico consistente en malestar general, fiebre no cuantificada, astenia y adinamia. En los paraclínicos se evidenció anemia, por lo que se realizó prueba de Coombs, la cual resultó positiva junto con otros hallazgos de anemia hemolítica autoinmune mixta. Se realizaron dos pruebas de tamizaje para VIH con técnica ELISA de cuarta generación que fueron positivas. Dadas las recomendaciones nacionales sobre el diagnóstico de la infección por VIH, se realizó una carga viral que resultó ser negativa, por lo que se consideró el resultado como un falso positivo.

Discusión. Factores clínicos y biológicos se relacionan con resultados falsos positivos. Existen descripciones sobre fenómenos de autoinmunidad, como el lupus eritematoso sistémico o la anemia hemolítica autoinmune, con pocos casos en adultos mayores.

Conclusiones. Las pruebas rápidas han cambiado el diagnóstico de la infección por VIH en el mundo; sin embargo, como toda prueba diagnóstica, tienen falsos positivos con diagnósticos diferenciales, incluidos la anemia hemolítica autoinmune.

Referencias

Teva I, Bermúdez MP, Ramiro MT, Buela-Casal G. Situación epidemiológica actual del VIH/SIDA en Latinoamérica en la primera década del siglo XXI: Análisis de las diferencias entre países. Rev. méd. Chile. 2012;140(1):50-8. http://doi.org/c5rk.

Mejía-Arreguí MH. Anemias hemolíticas autoinmunes. Rev MédInst Mex Seguro Soc.2005;43(Suppl 1):S25-8.

Alfonso-Valdés ME, Bencomo-Hernández A, Espinosa-Martínez E, Guerrero-Calderón R, Guerra-Borrego E, Guerrero-Calderón AI. Caracterización de pacientes adultos con anemia hemolítica autoinmune atendidos en el Instituto de Hematología e Inmunología. Rev Cubana Hematol Inmunol Hemoter. 2009 [cited2018Oct13];25(3). Available from: https://bit.ly/31ncpTA.

Liu P, Jackson P, Shaw N, Heysell S. Spectrum of false positivity for the fourth-generation human immunodeficiency virus diagnostic tests. AIDS Res Ther. 2016;13:1. http://doi.org/c65h.

Shida S, Takahashi N, Fujishima N, Kameoka Y, Nara M, Fujishima M, et al. False-positive human immunodeficiency virus antibody test and autoimmune hemolytic anemia in a patient with angioimmunoblastic T-cell lymphoma. Intern Med. 2011;50(20):2383-7. http://doi.org/dhgps8.

Petri M, Orbai AM, Alarcón GS, Gordon C, Merrill JT, Fortin PR, et al. Derivation and validation of the Systemic Lupus International Collaborating Clinics classification criteria for systemic lupus erythematosus. Arthritis Rheum. 2012;64(8):2677-786. http://doi.org/f239xz.

Colombia. Ministerio de Salud y Protección Social. Guía de práctica clínica basada en la evidencia científica para la atención de la infección por VIH/Sida en adolescentes (con 13 años de edad o más) y adultos. Guía completaGPC-2014-39. Bogotá D.C.: MinSalud; 2014.

Esteva MH, Blasini AM, Ogly D, Rodríguez MA. False positive results for antibody to HIV in two men with systemic lupus erythematosus. Ann Rheum Dis. 1992;51(9):1071-3. http://doi.org/dkv3sf.

Liao HY, Tao CM, Su J. Concomitant systemic lupus erythematosus and HIV infection: A rare case report and literature review. Medicine (Baltimore). 2017;96(51):e9337. http://doi.org/c65m.

Daikh BE, Holyst MM. Lupus-specific autoantibodies in concomitant human immunodeficiency virus and systemic lupus erythematosus: case report and literature review. Semin Arthritis Rheum. 2001;30(6):418-25. http://doi.org/bm2drs.

Barthel HR, Wallace DJ. False-positive human immunodeficiency virus testing in patients with lupus erythematosus. Semin Arthritis Rheum. 1993;23(1):1-7. http://doi.org/c8s5rd.

Muta T, Yamano Y. Angioimmunoblastic T-cell lymphoma associated with an antibody to human immunodeficiency virus protein. Int J Hematol. 2003;78(2):160-2. http://doi.org/fgnfhf.

Everett DB, Baisely KJ, McNerney R, Hambleton I, Chirwa T, Ross DA, et al. Association of schistosomiasis with false-positive HIV test Results in an African adolescent population. J Clin Microbiol. 2010;48(5):1570-7.http://doi.org/fnqpjv.

Khalife J, Grzych JM, Pierce R, Ameisen JC, Schacht AM, Gras-Masse H, et al. Immunological crossreactivity between the human immunodeficiency virus type 1 virion infectivity factor and a 170- kD surface antigen of Schistosoma mansoni. J Exp Med. 1990;172(3):1001-4. http://doi.org/dck3jh.

Jian L, Liang W, Zhang Y, Li L, Mei Y, Tan R, et al. Systemic lupus erythematosus patient with false positive results of antibody to HIV: A case report and a comprehensive literature review. Technol Health Care. 2015;23(Suppl 1):S99-S103. http://doi.org/c65r.

Zacharias NM, Athanassaki ID, Sangi-Haghpeykar H, Gardner MO. High false-positive rate of human immunodeficiency virus rapid serum screening in a predominantly hispanic prenatal population. J Perinatol. 2004;24(12):743- 7. http://doi.org/cts93j.

Colombia. Ministerio de Salud. Resolución 8430 de 1993 (octubre 4):Por la cual se establecen las normas científicas, técnicas y administrativas para la investigación en salud. Bogotá D.C.; octubre 4 de 1993 [cited 2019 Apr 6]. Available from: https://bit.ly/2nH9STI.

Asociación Médica Mundial. Declaración de Helsinki de la AMM. Principios éticos para las investigaciones médicas en seres humanos. Fortaleza: 64.a Asamblea General de la AMM; 2013 [cited 2019 Apr 6]. Available from: https://bit.ly/2r2W2cs.

Dimensions

PlumX

Visitas a la página del resumen del artículo

4407

Descargas

Los datos de descarga aún no están disponibles.

Cómo citar

Sánchez-Pardo, S., Osorio-Ramírez, J. A., Choi-Park, I., Rojas-Holguín, D. F., & Bolívar-Mejía, A. (2019). Falso positivo de prueba para VIH de cuarta generación asociado a anemia hemolítica autoinmune. Reporte de caso. Case Reports, 5(2), 132-138. https://doi.org/10.15446/cr.v5n2.78532