Published

2018-05-01

Fast Determination of Earthquake Depth Using Seismic Records of a Single Station, Implementing Machine Learning Techniques

Determinación rápida de la profundidad de un terremoto utilizando registros sísmicos de solo una estación implementando técnicas de aprendizaje de máquina

DOI:

https://doi.org/10.15446/ing.investig.v38n2.68407

Keywords:

Earthquake Early Warning, Rapid Response, Earthquake Depth, Seismic Event, Bogota – Colombia, Support Vector Machine Regression (SVMR), Seismology, Earthquakes. (en)
Alerta Temprana de Terremoto, Respuesta Rápida, Profundidad de un Terremoto, Evento Sísmico, Bogotá - Colombia, Máquinas de Soporte Vectorial (MSV), Sismología, Terremotos (es)

Downloads

Authors

  • Luis Hernán Ochoa Gutierrez Universidad Nacional de Colombia
  • Luis Fernando Niño Vasquez Universidad Nacional de Colombia
  • Carlos Alberto Vargas Jimenez Universidad Nacional de Colombia

The purpose of this research is to apply a new approach to make a fast determination of earthquake depth using seismic records of the “El Rosal” station, near to the city of Bogota – Colombia, by applying support vector machine regression (SVMR). The algorithm was trained with descriptors obtained from time signals of 863 seismic events acquired between January 1998 and October 2008; only earthquakes with magnitude ≥ 2 were contemplated, filtering its signals to remove diverse kind of noises not related to earth tremors. During training stages of SVMR several combinations of kernel function exponent and complexity factor were considered for time signals of 5, 10 and 15 seconds along with earthquake magnitudes of 2.0, 2.5, 3.0 and 3.5 (Ml). The best classification of SVMR was obtained using time signals of 15 seconds and earthquake magnitudes of 3.5 with kernel exponent of 10 and complexity factor of 2, showing accuracy of 0.6 ± 16.5 kilometers, which is good enough to be used in an early warning system for the city of Bogota. It is recommended to provide this model with a previous phase of deep-shallow classification.

El propósito de esta investigación es aplicar métodos de máquinas de vector de soporte (MVS) para determinar rápidamente las profundidades de terremotos utilizando registros sísmicos de la estación El Rosal, cerca de la ciudad de Bogotá – Colombia. El algoritmo fue entrenado con descriptores de señales de tiempo de 863 eventos sísmicos adquiridos entre enero de 1998 y octubre de 2008; solo se contemplaron terremotos de magnitudes ≥ 2 M_L, filtrando sus señales para remover diversos tipos de ruidos no relacionados con temblores terrestres. Durante las etapas de entrenamiento de la MVS varias combinaciones del exponente de la función kernel y factor de complejidad fueron considerados para señales de tiempo de 5, 10 y 15 segundos junto con terremotos de magnitudes 2.0, 2.5, 3.0 y 3.5 M_L. La mejor clasificación de la MVS fue obtenida utilizando señales de tiempo de 15 segundos y terremotos de magnitudes 3.5 M_L con exponente kernel de 10 y factor de complejidad de 2, mostrando precisión de 0,6 ± 16,5 kilómetros, lo cual es suficientemente bueno para ser utilizado en un sistema de alerta temprana para la ciudad de Bogotá. Se recomienda proveer este modelo con eventos sísmicos recientes, con la finalidad de mejorar su precisión. 

RIIv38n2Art_68407

Fast Determination of Earthquake Depth Using Seismic Records of a Single Station, Implementing Machine Learning Techniques

Determinación rápida de la profundidad de un terremoto utilizando registros sísmicos de solo una estación implementando técnicas de aprendizaje de máquina

 

Luis H. Ochoa 1, Luis F. Niño 2, and Carlos A. Vargas 3

 


 

1 Civil Engineer, M.Sc. Geophysics, M.Sc. Geomatics, Ph.D. System Engineering, Universidad Nacional de Colombia, Colombia. Affiliation: Associated Professor at Sciences Faculty, Geosciences Department, Universidad Nacional de Colombia (Colombia). lhochoag@unal.edu.co.

2 Systems Engineer, M.Sc. Mathematics, Universidad Nacional de Colombia, Colombia. M.Sc. and Ph.D. Computer Science, the University of Memphis, United States of America. Affiliation: Professor at Sciences Faculty, System Engineering Department, Universidad Nacional de Colombia (Colombia). lfninov@unal.edu.co.

3 Geologist, Universidad de Caldas, Colombia. M.Sc. and Ph.D. Seismic Engineering and Structural Dynamic, Universidad Politécnica de Catalunya, Spain. M.Sc. Physics Intrumentation, Universidad Tecnológica de Pereira, Colombia. Affiliation: Professor at Sciences Faculty, Geosciences Department, Universidad Nacional de Colombia (Colombia). E-mail: cavargasj@unal.edu.co.

 


How to cite: Ochoa, Luis H., Niño, Luis F., Vargas, Carlos A. Fast Determination of Earthquake Depth Using Seismic Records of a Single Station, implementing Machine Learning Techniques., Ingeniería e Investigación, 38(2), 91-103.

DOI:10.15446/ing.investig.v38n2.68407


ABSTRACT

The purpose of this research is to apply methods of support vector machines (SVMs) for fast determination of earthquake depths using seismic records of the “El Rosal” station, near to the city of Bogotá – Colombia. The algorithm was trained with time signal descriptors of 863 seismic events acquired between January 1998 and October 2008. Only earthquakes with magnitude ≥ 2 ML were contemplated, filtering its signals to remove diverse kind of noises not related to earth tremors. During training stages of SVM several combinations of kernel function exponent and complexity factor were considered for time signals of 5, 10 and 15 seconds along with earthquake magnitudes of 2.0, 2.5, 3.0 and 3.5 ML. The best classification of SVM was obtained using time signals of 15 seconds and earthquake magnitudes of 3.5 M_L with kernel exponent of 10 and complexity factor of 2, showing accuracy of 0,6 ± 16,5 kilometers, which is good enough to be used in an early warning system for the city of Bogotá. It is recommended to provide this model with more recent seismic events in order to improve its accuracy.


Keywords: Earthquake early warning, rapid response, earthquake depth, seismic event, Bogotá – Colombia, support vector machine regression (SVMR), seismology, earthquakes.


RESUMEN

El propósito de esta investigación es aplicar métodos de máquinas de vector de soporte (MVS) para determinar rápidamente las profundidades de terremotos utilizando registros sísmicos de la estación El Rosal, cerca de la ciudad de Bogotá – Colombia. El algoritmo fue entrenado con descriptores de señales de tiempo de 863 eventos sísmicos adquiridos entre enero de 1998 y octubre de 2008; solo se contemplaron terremotos de magnitudes ≥ 2 ML, filtrando sus señales para remover diversos tipos de ruidos no relacionados con temblores terrestres. Durante las etapas de entrenamiento de la MVS varias combinaciones del exponente de la función kernel y factor de complejidad fueron considerados para señales de tiempo de 5, 10 y 15 segundos junto con terremotos de magnitudes 2.0, 2.5, 3.0 y 3.5 ML. La mejor clasificación de la MVS fue obtenida utilizando señales de tiempo de 15 segundos y terremotos de magnitudes 3.5 ML con exponente kernel de 10 y factor de complejidad de 2, mostrando precisión de 0,6 ± 16,5 kilómetros, lo cual es suficientemente bueno para ser utilizado en un sistema de alerta temprana para la ciudad de Bogotá. Se recomienda proveer este modelo con eventos sísmicos recientes, con la finalidad de mejorar su precisión.


Palabras clave: Alerta temprana de terremoto, respuesta rápida, profundidad de un terremoto, evento sísmico, Bogotá - Colombia, máquina de soporte vectorial (MSV), sismología, terremotos.


Received: October 19th 2017

Accepted: January 18th 2018


Introduction

This study is part of an investigation line which proposes calculation of earthquake hypocentral parameters by using machine learning techniques, in order to develop an early warning system for the city of Bogotá. Bogotá’s Savannah and surrounding areas hold almost a third of Colombian population, being the main economic center of the country with almost 40% of the gross domestic product (Ojeda et al., 2002); this is why a seismic early warning system around Bogotá is so important, and the earthquake depth is one of the main parameter in this system.

The common way to calculate hypocentral parameters, including earthquake depth, consists to apply velocity models for different rock layers of the earth and processing travel time signals of P and S waves recorded in seismic stations (Zhang et al., 2014). In recent years, alternative approaches based on machine learning techniques have been developed, most of them using genetic algorithms (GA) and fuzzy logic (FL). The FL approaches allow efficient exploration of the searching space (Lin and Sanford, 2001), while the GA are manly used to determine X, Y, Z coordinates of earthquake hypocenter (Sambrige & Gallagher, 1993). Ochoa et al. (2014) and Ochoa et al. (2017) successfully applied methods of support vector machines (SVMs) on estimations of hypocentral parameters using only a few signal seconds registered at a single seismological station achieving reliable results.

The aim of this study consist to apply SVMs to figure the earthquakes depth out by using data acquired at the “El Rosal” seismic station. This station is located northwest to Bogotá and it is part of the Colombian seismic network ( Figure 1) administrated by the “Servicio Geológico Colombiano - SGC” (Colombian Geological Service). The earthquakes depth distributions around Bogotá are also shown in Figure 1, suggesting high seismicity in surrounding areas.

 

Figure 1. Distribution of Seismic Events Around Bogotá. Plane coordinates Gauss Bogotá Origin.

Source : Authors

 

“El Rosal” Station and Dataset Used

The “El Rosal” station employs a Guralp CMG - T3E007 sensor in three components and a nanometrics RD3-HRD24 digitizer, which provides simultaneous sampling of the three channels with 24-bit of resolution (Bermudez & Rengifo, 2002). The used data correspond to three component raw waveforms recorded in the station and its seismic not declustered catalogue of 2164 events, embracing between January 1st of 1998 and October 27th of 2008; all these events located less than 120 kilometers from the seismic station (Figure 1).

Before starting the processing related to SVMs, the waveform files were converted to the American standard code for information interchange (ASCII) format, using a Seisan package tool (Ottemoller et al., 2016). Because of earthquakes with magnitudes lower than 2.0 M_L can be related to man-made tremors, these events along with all extreme or anomalous values were removed, reducing the data set to 863 events. Since the selected seismic records present variable levels of noise, it was necessary to filter them out with both high and low frequency filters. Low frequencies correspond to instrumental noise, easily eliminated through implementation of a high-pass filter with cutoff frequency of 0,075 Hz, and high frequencies were removed with a low-pass filter with cutoff of 150 Hz (Wu & Zhao, 2006).

The statistical distribution of earthquakes depth in the area is presented in Figure 2. This bar chart shows a bimodal pattern, suggesting two levels of seismic sources; the first around 15 kilometers and the second around 150 kilometers of depth. The seismicity 15 kilometers of depth is one of the main interests in early warning systems; because of these shallow earthquakes usually produce great damage to near populations.

 

Figure 2. Statistical Distribution of Earthquakes Depth.

Source : Authors

 

Support Vector Machines (SVMs)

The SVMs are a group of supervised learning algorithms related to classification and regression problems. When a sample is given to train, it can be separated into classes and train a SVM model to predict the classes within a new sample; a SVM represents the points of a sample in space, separating classes within these points in a widest possible spaces. When new samples are projected in this model, they can be classified to any class in function of proximity of the points. The model of SVM applied in this research is based on its complexity factor “C” and the kernel function selected. The complexity factor regulates accuracy of the model; this factor can lead the model trains properly (generalization), or else, it can reach a point of overfitting. A proper generalization refers the model ability to classify accurately several samples different than the employed during training stage; moreover, overfitting occurs when the model can only classify correctly the sample used during training.

The Kernel function project a dataset in a space of specific characteristics and uses algorithms related to linear algebra, geometry and statistics to identify linear patterns in the dataset. Any solution using kernel methods comprises two phases; first phase consists of a module that performs a mapping of the projected data; second phase contains an algorithm designed to detect linear patterns in the space where this data is projected (Taylor & Cristianini, 2004). The function kernel applied in this study was a polynomial type using the Equation (1).

 

(1)

 

Where “E” is a parameter representing the kernel exponent and (K) represents the kernel function depending on variables (x) and (y).

 

The Input Data Set of the SVM

On the first stage, parameters that have been previously used for other authors to earthquake magnitude estimation were calculated and employed as input variables or descriptors for the SVM of this research. In this sense, the relationship between maximum P wave amplitudes and local earthquake magnitudes was considered (Wu & Kanamori, 2005), where a linear regression was performed for each one of the three components. Three parameters were taken from this linear regressions which correspond to slope (M), independent term (B) and correlation coefficient (R). The maximum amplitude values (Mx) obtained for each component’s time window were used as descriptors as well. Therefore, each event had 12 descriptors associated with this concept.

In second place, 9 descriptors used for epicenter distance estimation were added, by adjusting a linear regression of an exponential expression in time (t) using the Equation (2).

 

(2)

This equation belongs to the envelope of the seismic record in a logarithmic scale (Odaka et al., 2003) determined also by a linear regression and its respective correlation coefficient (R), for each of component in the seismic station. The correlation coefficient (R) along with the parameters (A) and (B) were calculated for each component of the station; where (B) represents the slope of initial part of P waves and (A) is a parameter related to amplitude variations in time.

Finally, parameters used for back-azimuth determination were used to include information about sources location of the seismic events into the model. Maximum eigenvalues of two-dimensional covariance matrix were used as input, calculated as described in Magotra et al. (1987) and Magotra et al. (1989). A windowing scheme with one second time windows was performed, to obtain consecutive values for which a linear regression was calculated, also determining the slope (M), the independent term (B), the correlation factor (R) of the regression, and this time with addition of the arithmetic mean of the eigenvalues (P). This last processing works with all components of the station together, so only 4 descriptors were added as input related to this process.

 

Table 1. Summary Of Descriptors Employ as Input data of the SVM

Related to earthquake magnitude estimation (Wu & Kanamori, 2005)

Related to epicenter distance estimation (Odaka et al., 2003)

Related to back-azimuth estimation (Magotra et al., 1987) & (Magotra et al., 1989)

Slope (M)

Ind. Term (B)

Corr. Coeff. (R)

Max. Amp. (Mx)

Parm. (A)

Parm. (B)

Corr. Coeff. (R)

Slope (M)

Ind. Term (B)

Corr. Coeff. (R)

M. Eig. (P)

12 Descriptors (4 in each component of the station).

9 Descriptors (3 in each component of the station).

4 Descriptors (all components work together).

Source: Authors

 

In summary, the SVM of this study employs 25 time signal descriptors as input data (Table 1); 12 of them related to works on magnitude calculation, 9 were associated with epicenter distance estimations and the last 4 were used in back-azimuth determination. These descriptors were calculated for 5, 10 and 15 seconds signal of the 863 selected events.

 

Results

Using the descriptors explained before and real magnitudes for each considered seismic event, a group of 12 datasets were evaluated in order to find the best combination of cutoff magnitude and time signal length (Table 2). Each dataset corresponds to 4 magnitudes (2.0, 2.5, 3.0 and 3.5 M_L) and 3 time signal length (5, 10 and 15 s), along with 7 values of kernel exponent “E” and 6 values of complexity factor “C”, summarizing 504 tested models of SVM. This processing was developed using the Weka 3.6 software (Eibe et al., 2016); this algorithm has a strong statistical support and is easily implemented on the station by electronic processing cards. The free parameter “C” and “E” of the SVM were randomly considered in this step, and they were precisely selected after the best combination of magnitude and time signal length was obtained.

The Pearson’s coefficient was calculated for each partition, measuring linear relationship between two variables independently of their scales (Table 2). Positive values mean that two variables change in the same way, i.e. high values of one variable correspond to high values of the other and vice-versa. The closer is this value to one, the greater certainty that two variables have linear relation. It can be observed that best values of Pearson’s coefficient are 0.857 and 0.898 for time signals of 10 and 15 seconds respectively with magnitude ≥ 3.5 M_L.

Table 3 shows low standard deviation but high kurtosis for time signal of 10 seconds, indicating that dispersion in residual values is too high and not recommended for depth determination; instead, it is better to choose a time signal of 15 seconds which has standard deviation of 16.5 kilometers and lower kurtosis for a magnitude of 3.5. Once the best combination of magnitude and time signal is obtained, the free parameters “C” and “E” are chosen using the Table 4, where Pearson’s coefficient and mean absolute error are presented for each combination. Based on these results, a SVM can be implemented using “E” of 10 and “C” of 2, indicating a reliable model with accuracy of 0,6 ± 16,5 kilometers in earthquake depth determination. Figure 3 shows the cross-plot with relationship between the real earthquake depth (X axis) and the calculated depth by the model (Y axis). The dashed line represents the linear behavior of predicted data, corresponding to the locus where prediction is equal to real values.

 

Figure 3. Relationship between real and calculated depth.

Source: Authors

Conclusions

The model proposed in this study is an important step towards implementation of an early earthquake warning system for the city of Bogotá – Colombia, and its results can supply reliable information to this system using data of the “El Rosal” station in only 15 seconds before arrival of an earthquake. The accuracy of this study is as high as 0,6 ± 16,5 kilometers in earthquake depth determination, employing a support vector machine with complexity factor of 2 and a polynomial function kernel with exponent of 10.

This model can be implemented in seismological stations directly in the electronic devices embedded at each station, where the main mathematical process corresponds to a simple matrix product involving the given kernel and a vector which contains calculated descriptors of the seismic events.

The results showed in this study are in the same order than (Hsiao, 2011), who reported accuracy of 7,9 ± 6,6 kilometers using data of 5 stations in earthquake depth determination. Also these results are an improvement on that of Romeu (2016) who was as accurate as ± 23 kilometers.

 

Recommendations

According to Figure 2, this model may be improved by applying two different SVM models; the first one for shallow earthquakes with depth of 15 kilometers and the second for deeper earthquakes with 150 kilometers of depth.

It is important to find ways to improve the prediction accuracy based on further research, supported by computational intelligence and geophysics research groups as well as the seismological network of the Bogotá’s Savannah and its surroundings administrated by the Universidad Nacional de Colombia. Additionally, datasets should be complemented with recent seismic events, not considered in this research.

 

Acknowledgements

The authors are grateful to the “Servicio Geológico Colombiano” (SGC) for providing the data used in this research and to the “Universidad Nacional de Colombia” for supporting our efforts to achieve a fast and reliable early warning system for the city of Bogotá – Colombia.

 

Table 2. Cutoff Magnitude and Time Length Combinations

Pearson’s Coefficient for Each Combination of Magnitude and Time Signal

Magnitude ≥ 2.0 M_L – “E”

Magnitude ≥ 2.5 M_L – “E”

Time Signal = 15 s – “C”

1.5

2

4

5

10

20

50

1.5

2

4

5

10

20

50

1

0,573

0,589

0,634

0,646

0,677

0,709

0,707

1

0,565

0,584

0,614

0,629

0,691

0,732

0,728

3

0,598

0,622

0,665

0,665

0,708

0,714

0,705

3

0,591

0,609

0,663

0,684

0,738

0,757

0,728

5

0,614

0,637

0,676

0,638

0,717

0,709

0,696

5

0,607

0,63

0,686

0,709

0,754

0,755

0,726

10

0,634

0,654

0,688

0,701

0,717

0,689

0,683

10

0,628

0,657

0,706

0,72

0,736

0,735

0,726

20

0,649

0,670

0,703

0,710

0,704

0,674

0,674

20

0,663

0,674

0,718

0,733

0,744

0,721

0,726

50

0,672

0,685

0,711

0,713

0,668

0,638

0,665

50

0,685

0,699

0,725

0,733

0,697

0,71

0,726

Time Signal = 10 s – “C”

1,5

2

4

5

10

20

50

1,5

2

4

5

10

20

50

1

0,488

0,51

0,564

0,576

0,597

0,622

0,621

1

0,493

0,52

0,574

0,594

0,642

0,662

0,639

3

0,519

0,542

0,587

0,593

0,611

0,631

0,583

3

0,538

0,56

0,621

0,636

0,662

0,666

0,627

5

0,533

0,562

0,594

0,602

0,617

0,627

0,569

5

0,553

0,59

0,637

0,651

0,662

0,64

0,618

10

0,555

0,588

0,602

0,603

0,63

0,601

0,553

10

0,59

0,617

0,652

0,656

0,667

0,602

0,605

20

0,581

0,59

0,06

0,608

0,621

0,554

0,548

20

0,617

0,63

0,652

0,649

0,639

0,57

0,605

50

0,586

0,596

0,608

0,625

0,575

0,502

0,546

50

0,624

0,64

0,628

0,629

0,574

0,529

0,605

Time Signal = 05 s – “C”

1.5

2

4

5

10

20

50

1.5

2

4

5

10

20

50

1

0,38

0,406

0,443

0,45

0,459

0,464

0,43

1

0,359

0,38

0,442

0,453

0,496

0,515

0,502

3

0,415

0,434

0,451

0,457

0,464

0,447

0,4

3

0,375

0,41

0,466

0,479

0,517

0,512

0,488

5

0,427

0,441

0,456

0,461

0,459

0,429

0,392

5

0,385

0,419

0,475

0,487

0,52

0,51

0,473

10

0,435

0,445

0,458

0,461

0,449

0,401

0,372

10

0,392

0,44

0,491

0,506

0,507

0,485

0,459

20

0,439

0,446

0,454

0,453

0,422

0,377

0,349

20

0,424

450

0,5

0,511

0,486

0,462

0,456

50

0,439

0,435

0,437

0,44

0,384

0,349

0,334

50

0,444

0,467

0,495

0,492

0,435

0,436

0,456

Magnitude ≥ 3.0 M_L – “E”

Magnitude ≥ 3.5 M_L – “E”

Time Signal = 15 s – “C”

1.5

2

4

5

10

20

50

1.5

2

4

5

10

20

50

1

0,547

0,579

0,658

0,667

0,706

0,673

0,603

1

0,808

0,814

0,815

0,807

0,747

0,643

0,466

3

0,590

0,624

0,686

0,696

0,686

0,660

0,601

3

0,869

0,878

0,851

0,834

0,767

0,64

0,466

5

0,597

0,641

0,686

0,689

0,682

0,659

0,601

5

0,898

889

0,86

854

0,772

0,64

0,466

10

0,611

0,661

0,675

0,674

0,683

0,659

0,601

10

0,897

0,892

0,883

0,869

0,772

0,64

0,466

20

0,639

0,667

0,647

0,660

0,686

0,659

0,601

20

0,89

0,895

0,891

0,873

0,772

0,64

0,466

50

0,647

0,597

0,636

0,655

0,685

0,659

0,601

50

0,89

0,896

0,891

0,873

0,772

0,64

0,466

Time Signal = 10 s – “C”

1.5

2

4

5

10

20

50

1.5

2

4

5

10

20

50

1

0,513

0,544

0,587

0,613

0,708

0,732

0,661

1

0,744

0,778

0,793

0,779

0,75

0,07

0,551

3

0,524

0,547

0,625

0,665

0,761

0,716

0,662

3

0,843

0,838

0,795

0,788

0,752

0,07

0,551

5

0,515

0,536

0,65

0,702

0,757

0,714

0,662

5

0,848

0,839

0,799

0,788

0,752

0,07

0,551

10

0,511

0,544

0,7

0,74

0,715

0,716

0,662

10

0,857

0,823

0,798

0,789

0,752

0,07

0,551

20

0,509

0,576

0,729

0,732

0,711

0,716

0,662

20

0,837

0,816

0,8

0,789

0,752

0,07

0,551

50

0,557

0,625

0,685

0,655

0,717

0,716

0,662

50

0,804

0,81

0,8

0,789

0,752

0,07

0,551

Time Signal = 05 s – “C”

1.5

2

4

5

10

20

50

1.5

2

4

5

10

20

50

1

0,25

0,268

0,484

0,392

0,496

0,578

0,483

1

0,438

0,443

0,463

0,491

0,462

0,505

0,545

3

0,238

0,277

0,477

0,538

0,622

0,584

0,483

3

0,48

0,523

0,548

0,489

0,419

0,507

0,545

5

0,242

0,3

0,541

0,582

0,63

0,564

0,483

5

0,558

0,599

0,504

0,464

0,421

0,507

0,545

10

0,255

0,374

0,577

0,599

0,619

0,521

0,483

10

0,649

0,631

0,453

0,387

0,421

0,507

0,545

20

0,341

0,472

0,572

0,602

0,574

0,521

0,483

20

0,673

0,59

0,394

0,389

0,421

0,507

0,545

50

0,45

0,484

0,549

0,558

0,525

0,521

0,483

50

0,596

0,493

0,398

0,389

0,421

0,507

0,545

Surce: Authors

 

Table 3. Statistical Summary for Best Models in Each Combination

SUMMARY OF DEPTH DETERMINATION - RESIDUAL

Signal Time = 15 s

Signal Time = 10 s

Signal Time = 05 s

Minimum Magnitude

2.0

2.5

3.0

3.5

2.0

2.5

3.0

3.5

2.0

2.5

3.0

3.5

Mean

1.35

0.97

3.79

0.60

2.03

2.24

-0.53

-1.00

1.2

4.15

-1.55

0.67

Typical Error

1.12

1.25

2.30

2.87

0.78

1.12

1.48

2.35

1.65

1.98

1.74

4.05

Standard Deviation

32.9

24.3

25.8

16.5

23.0

21.7

16.6

13.5

48.6

38.5

19.6

23.3

Kurtosis

1.86

4.88

3.13

4.63

5.19

5.85

8.50

5.02

0.03

0.93

11.49

6.05

Asymmetric Coefficient

0.20

0.55

0.66

-1.15

0.87

0.63

-1.15

0.20

0.05

0.38

-1.91

1.36

Count

863

379

126

33

863

379

126

33

864

377

126

33

Level of Confidence (95%)

2.201

2.453

4.454

5.855

1.537

2.196

2.920

4.778

3.247

3.895

3.449

8.260

Source: Authors

 

Table 4. Pearson’s Coefficient and Mean Absolute Error Used to Determent “E” and “C”

Pearson’s Coefficient 0.5

Exponent “E”

0.8

1.1

1.5

2

4

5

10

20

50

Complexity Factor “C”

0.1

0,379

0,397

0,424

0,456

0,483

0,529

0,538

0,58

0,591

0,502

0.5

0,53

0,478

0,496

0,516

0,546

0,634

0,653

0,662

0,684

0,608

0.8

0,471

0,493

0,513

0,538

0,568

0,655

0,661

0,698

0,676

0,602

1

0,48

0,499

0,52

0,546

0,579

0,658

0,668

0,706

0,673

0,603

2

0,496

0,508

0,53

0,572

0,605

0,675

0,69

0,698

0,661

0,601

4

0,487

0,523

0,564

0,596

0,637

0,689

0,69

0,678

0,66

0,601

5

0,49

0,54

0,571

0,596

0,641

0,686

0,689

0,682

0,659

0,601

10

0,526

0,554

0,569

0,611

0,661

0,675

0,674

0,683

0,659

0,601

20

0,492

0,529

0,551

0,639

0,667

0,646

0,66

0,686

0,659

0,601

50

0,352

0,452

0,575

0,646

0,597

0,637

0,654

0,685

0,659

0,601

Mean Absolute Error 0.5

Exponent “E”

0.8

1.1

1.5

2

4

5

10

20

50

Complexity Factor “C”

0.1

57,5

56,5

55,5

54

52,5

49,1

48,2

46,3

47,3

52,2

0.5

48,7

48,9

48

47,2

45,7

41,2

40,4

40,1

39

44,4

0.8

49,2

48,2

47,4

46,1

44,5

40,2

39,7

37,9

38,9

44,7

1

48,7

48

47

45,7

44

40

39,4

37,1

38,7

44,7

2

48,2

47,5

46,7

45

42,5

38,8

38

36,5

38,7

44,8

4

48,7

47,7

45,5

43,3

41

38

37,5

35,9

38,7

44,8

5

48,9

47,1

45

43,2

40,7

37,9

37

35,7

38,8

44,8

10

48

45,9

44,9

41,9

39,4

37,4

37

35,7

39,1

44,8

20

49,9

6,8

44,9

40,3

38,2

37,7

36,9

36,3

39,1

44,8

50

62,2

53,5

42,9

38,9

40,4

38,4

37,5

36,6

39,1

44,8

Source: Authors

 

References

 

Bermudez, M., & Rengifo, F. (2002). EL ROSAL: La Estación Sismológica del CTBTO en Colombia. (8). Bogotá: Primer Simposio Colombiano de Sismología.

Eibe, F., Hall, M., & Witten, I. (2016). The WEKA Workbench. Online Appendix for “Data Mining: Practical Machine Learning Tools and Techniques (Fourth Edition eEd.). Morgan Kaufmann.

Hsiao, N. (2011). A new prototype system for earthquake early warning system in Taiwan. soil Dynamic and Earthquake Engineering, 201-208. https://doi.org/10.1016/j.soildyn.2010.01.008

Lin, K.-W., & Sanford, A. (2001). Improving Regional Earthquake Locations Using Modified G Matrix and Fussy Logic. Bulletin of the Seismological Society of America, 82-93.

Magotra, N., Ahmed, N., & Chael, E. (1987, June). Seismic event detection and source location using single station (three component) data. Bull. Seism. Asoc. Am., 77(3), 958-971.

Magotra, N., Ahmed, N., & Chael, E. (1989, January). Single-station seismic event detection and location. IEEE Transactions on Geoscience and Remote Sensing, 27(1), 15-23. 10.1109/36.20270

Ochoa, L. H., Niño, L. F., & Vargas, C. A. (2017). Fast magnitude determination using a single seismological station record implementing machine learning techniques. Sciences Direct, Geodesy and Geodynamic, 1-8. https://doi.org/10.1016/j.geog.2017.03.010

Ochoa, L., Niño, L., & Vargas, C. (2014, December). Severity Classification of a Seismic Event based on the Magnitude-Distance Ratio Using Only One Seismological Station. Earth Sciences Research Journal, 18(2), 115-122. https://doi.org/10.15446/esrj.v18n2.41083

Odaka, T., Ashiya, K., Tsukada, S., Sato, S., Ohtake, K., & Nozaka, D. (2003, February). A new method for quickly estimating epicentral distance and magnitude from a single seismic record. Bull. Seism. Soc. Am., 93(1), 526-532. 10.1785/0120020008

Ojeda, A., Martinez, S., Bermudez, M., & Atakan, K. (2002, October). The new accelerograph network for Santa Fe De Bogota, Colombia. Soil Dynamics and Earthquake Engineering, 791-797. https://doi.org/10.1016/S0267-7261 (02)00100-8

Ottemoller, L., Voss, P., & Havskov, J. (2016). SEISAN EARTHQUAKE ANALYSIS SOFTWARE FOR WINDOWS, SOLARIS, LINUX and MACOSX.

Romeu, P. (2016). Development of an Early Warning System Based on Earthworm: Application to Southwest Iberia. Bulletin of Seismological Socierty of America, 1-12. https://doi.org/10.1785/0120150192

Sambrige, M., & Gallagher, K. (1993). Earthquake hypocenter locations using genetic algorithms. Bulleting of the Seismological Society of America, 1467-1491.

Taylor, J., & Cristianini, N. (2004). Kernel Methods for Pattern Analysis. Cambridge, United Kingdom: Cambridge University Press.

Wu, Y. M., & Zhao, L. (2006, August). Magnitude estimation using the first three seconds P-wave amplitude in earthquake early warning. Geophysics. Res. Lett., 33(16), L16312. 10.1029/2006GL026871

Wu, Y., & Kanamori, H. (2005). Experiment on an onsite early warning method for the Taiwan early warning system. Bulletin of the Seismoligical Society of America, 347-353. https://doi.org/10.1785/0120040193

Zhang, M., Tian, D., & Wen, L. (2014, February 25). A new method for earthquake depth determination: stacking multiple-station autocorrelograms. (A. Access, Ed.) Geophysical Journal International (197), 1107-1116. 10.1093/gji/ggu044

 

 

Attribution 4.0 International (CC BY 4.0) Share - Adapt

References

Bermudez, M., & Rengifo, F. (2002). EL ROSAL: La Estación Sismológica del CTBTO en Colombia. (8). Bogotá: Primer Simposio Colombiano de Sismología.

Eibe, F., Hall, M., & Witten, I. (2016). The WEKA Workbench. Online Appendix for “Data Mining: Practical Machine Learning Tools and Techniques (Fourth Edition eEd.). Morgan Kaufmann.

Hsiao, N. (2011). A new prototype system for earthquake early warning system in Taiwan. soil Dynamic and Earthquake Engineering, 201-208. DOI: https://doi.org/10.1016/j.soildyn.2010.01.008

Lin, K.-W., & Sanford, A. (2001). Improving Regional Earthquake Locations Using Modified G Matrix and Fussy Logic. Bulletin of the Seismological Society of America, 82-93.

Magotra, N., Ahmed, N., & Chael, E. (1989, January). Single-station seismic event detection and location. IEEE Transactions on Geoscience and Remote Sensing, 27(1), 15-23. DOI: https://doi.org/10.1109/36.20270

Ochoa, L. H., Niño, L. F., & Vargas, C. A. (2017). Fast magnitude determination using a single seismological station record implementing machine learning techniques. Sciences Direct, Geodesy and Geodynamic, 1-8. DOI: https://doi.org/10.1016/j.geog.2017.03.010

Ochoa, L., Niño, L., & Vargas, C. (2014, December). Severity Classification of a Seismic Event based on the Magnitude-Distance Ratio Using Only One Seismological Station. Earth Sciences Research Journal, 18(2), 115-122. DOI: https://doi.org/10.15446/esrj.v18n2.41083

Odaka, T., Ashiya, K., Tsukada, S., Sato, S., Ohtake, K., & Nozaka, D. (2003, February). A new method for quickly estimating epicentral distance and magnitude from a single seismic record. Bull. Seism. Soc. Am., 93(1), 526-532. DOI: https://doi.org/10.1785/0120020008

Ojeda, A., Martinez, S., Bermudez, M., & Atakan, K. (2002, October). The new accelerograph network for Santa Fe De Bogota, Colombia. Soil Dynamics and Earthquake Engineering, 791-797. DOI: https://doi.org/10.1016/S0267-7261(02)00100-8

Ottemoller, L., Voss, P., & Havskov, J. (2016). SEISAN EARTHQUAKE ANALYSIS SOFTWARE FOR WINDOWS, SOLARIS, LINUX and MACOSX.

Romeu, P. (2016). Development of an Early Warning System Based on Earthworm: Application to Southwest Iberia. Bulletin of Seismological Socierty of America, 1-12. DOI: https://doi.org/10.1785/0120150192

Sambrige, M., & Gallagher, K. (1993). Earthquake hypocenter locations using genetic algorithms. Bulleting of the Seismological Society of America, 1467-1491.

Taylor, J., & Cristianini, N. (2004). Kernel Methods for Pattern Analysis. Cambridge, United Kingdom: Cambridge University Press.

Wu, Y. M., & Zhao, L. (2006, August). Magnitude estimation using the first three seconds P-wave amplitude in earthquake early warning. Geophysics. Res. Lett., 33(16), L16312. DOI: https://doi.org/10.1029/2006GL026871

Wu, Y., & Kanamori, H. (2005). Experiment on an onsite early warning method for the Taiwan early warning system. Bulletin of the Seismoligical Society of America, 347-353. DOI: https://doi.org/10.1785/0120040193

Zhang, M., Tian, D., & Wen, L. (2014, February 25). A new method for earthquake depth determination: stacking multiple-station autocorrelograms. (A. Access, Ed.) Geophysical Journal International (197), 1107-1116. DOI: https://doi.org/10.1093/gji/ggu044

How to Cite

APA

Ochoa Gutierrez, L. H., Niño Vasquez, L. F. and Vargas Jimenez, C. A. (2018). Fast Determination of Earthquake Depth Using Seismic Records of a Single Station, Implementing Machine Learning Techniques. Ingeniería e Investigación, 38(2), 97–103. https://doi.org/10.15446/ing.investig.v38n2.68407

ACM

[1]
Ochoa Gutierrez, L.H., Niño Vasquez, L.F. and Vargas Jimenez, C.A. 2018. Fast Determination of Earthquake Depth Using Seismic Records of a Single Station, Implementing Machine Learning Techniques. Ingeniería e Investigación. 38, 2 (May 2018), 97–103. DOI:https://doi.org/10.15446/ing.investig.v38n2.68407.

ACS

(1)
Ochoa Gutierrez, L. H.; Niño Vasquez, L. F.; Vargas Jimenez, C. A. Fast Determination of Earthquake Depth Using Seismic Records of a Single Station, Implementing Machine Learning Techniques. Ing. Inv. 2018, 38, 97-103.

ABNT

OCHOA GUTIERREZ, L. H.; NIÑO VASQUEZ, L. F.; VARGAS JIMENEZ, C. A. Fast Determination of Earthquake Depth Using Seismic Records of a Single Station, Implementing Machine Learning Techniques. Ingeniería e Investigación, [S. l.], v. 38, n. 2, p. 97–103, 2018. DOI: 10.15446/ing.investig.v38n2.68407. Disponível em: https://revistas.unal.edu.co/index.php/ingeinv/article/view/68407. Acesso em: 13 apr. 2025.

Chicago

Ochoa Gutierrez, Luis Hernán, Luis Fernando Niño Vasquez, and Carlos Alberto Vargas Jimenez. 2018. “Fast Determination of Earthquake Depth Using Seismic Records of a Single Station, Implementing Machine Learning Techniques”. Ingeniería E Investigación 38 (2):97-103. https://doi.org/10.15446/ing.investig.v38n2.68407.

Harvard

Ochoa Gutierrez, L. H., Niño Vasquez, L. F. and Vargas Jimenez, C. A. (2018) “Fast Determination of Earthquake Depth Using Seismic Records of a Single Station, Implementing Machine Learning Techniques”, Ingeniería e Investigación, 38(2), pp. 97–103. doi: 10.15446/ing.investig.v38n2.68407.

IEEE

[1]
L. H. Ochoa Gutierrez, L. F. Niño Vasquez, and C. A. Vargas Jimenez, “Fast Determination of Earthquake Depth Using Seismic Records of a Single Station, Implementing Machine Learning Techniques”, Ing. Inv., vol. 38, no. 2, pp. 97–103, May 2018.

MLA

Ochoa Gutierrez, L. H., L. F. Niño Vasquez, and C. A. Vargas Jimenez. “Fast Determination of Earthquake Depth Using Seismic Records of a Single Station, Implementing Machine Learning Techniques”. Ingeniería e Investigación, vol. 38, no. 2, May 2018, pp. 97-103, doi:10.15446/ing.investig.v38n2.68407.

Turabian

Ochoa Gutierrez, Luis Hernán, Luis Fernando Niño Vasquez, and Carlos Alberto Vargas Jimenez. “Fast Determination of Earthquake Depth Using Seismic Records of a Single Station, Implementing Machine Learning Techniques”. Ingeniería e Investigación 38, no. 2 (May 1, 2018): 97–103. Accessed April 13, 2025. https://revistas.unal.edu.co/index.php/ingeinv/article/view/68407.

Vancouver

1.
Ochoa Gutierrez LH, Niño Vasquez LF, Vargas Jimenez CA. Fast Determination of Earthquake Depth Using Seismic Records of a Single Station, Implementing Machine Learning Techniques. Ing. Inv. [Internet]. 2018 May 1 [cited 2025 Apr. 13];38(2):97-103. Available from: https://revistas.unal.edu.co/index.php/ingeinv/article/view/68407

Download Citation

CrossRef Cited-by

CrossRef citations2

1. Hapsoro Agung Nugroho, Haryas Subyantara Wicaksana. (2019). Acceleration classification of earthquake signals and linear signals of human activity using smartphone accelerometer based on support vector machine algorithm. Jurnal Teknologi dan Sistem Komputer, 7(4), p.166. https://doi.org/10.14710/jtsiskom.7.4.2019.166-171.

2. Luis Hernán Ochoa Gutierrez, Luis Fernando Niño Vasquez, Carlos Alberto Vargas Jimenez. (2019). Support vector machines applied to fast determination of the geographical coordinates of earthquakes, The case of El Rosal seismological station, Bogotá Colombia. DYNA, 86(209), p.230. https://doi.org/10.15446/dyna.v86n209.75444.

Dimensions

PlumX

  • Citations
  • CrossRef - Citation Indexes: 2
  • Scopus - Citation Indexes: 3
  • Usage
  • SciELO - Full Text Views: 285
  • SciELO - Abstract Views: 97
  • Captures
  • Mendeley - Readers: 24
  • Social Media
  • Facebook - Shares, Likes & Comments: 44

Article abstract page views

2518

Downloads

Most read articles by the same author(s)