Asystole in an older patient with recurrent falls. Case report
Asistolia en paciente mayor con caídas a repetición. Reporte de caso
DOI:
https://doi.org/10.15446/cr.v6n1.82558Palabras clave:
Syncope, Asystole, Pacemaker Artificial, Sinus Arrest Cardiac (en)Síncope, Asistolia, Marcapasos artificial, Paro sinusal cardíaco (es)
Descargas
Introduction: Recurrent falls are a usual problema in older patients. It is therefore important to learn how to differentiate a pathological or syncopal episode from a simple stumbling fall, especially in patients who have limitations for communicating clearly and are poorly understood, in general terms, during the medical consultation. Implantable loop recorders (ILR) have been used as an investigation tool in selected cases of recurrent falls in older patients. Consequently, this case report aims to describe its usefulness in this type of patients.
Case presentation: An 87-year-old female patient, hypertensive, with a history of recent stroke and frequent falls —referred to as stumbling—, received an implantable loop recorder due to atrial fibrillation. During one follow-up appointment, a 36-second pause related to a fall was documented, so a bicameral pacemaker was implanted.
Conclusions: Evaluating repeated falls in older patients is complex; it must be done in detail to rule out syncopal episodes. Implantable devices to diagnose arrhythmic causes are useful and allow achieving accurate diagnoses and establish specific behaviors aimed at improving the quality of life of patients.
Introducción. Las caídas frecuentes son un problema común en pacientes de la tercera y la cuarta edad, por tanto es importante saber diferenciar cuando se trata de un evento patológico o sincopal, y cuando es un simple tropiezo, sobre todo en pacientes que tienen limitaciones para comunicarse de forma clara y son poco entendidos en términos generales durante la consulta médica. Los monitores de eventos cardiacos pueden ser usados en casos seleccionados de caídas frecuentes en adultos mayores para determinar las posibles causas de estos eventos, por lo que el presente reporte de caso pretende mostrar cuál es su utilidad en un paciente con caídas no sincopales a repetición.
Presentación del caso. Paciente femenina de 87 años, hipertensa, con evento cerebrovascular reciente e historia de caídas a repetición referidas como tropiezos, a quien se le implantó un dispositivo diagnóstico de fibrilación auricular. En uno de los controles se observó pausa de 36 segundos relacionada con episodio de caída, por lo que se implantó un marcapasos bicameral.
Conclusiones. La evaluación de caídas a repetición en pacientes mayores es compleja y debe realizarse de forma detallada para descartar síncope. El uso de monitores de eventos cardiacos para la identificación de causas arrítmicas de estos eventos permite diagnósticos certeros, con lo que a su vez es posible establecer tratamientos específicos que mejoren la calidad de vida de los pacientes.
Referencias
Thobaben M. Fall prevention for older adults. Home Heal Care Manag Pract. 2009;21(6):445-7. http://doi.org/fr7mkv.
Méndez-Flórez J, Agudelo-zapata Y, Torres-Villareal MC, León LP, Guarín-Loaiza G, Torres-Zaavedra F, et al. Uso de desfibriladores implantables y terapia de resincronización cardiaca en ancianos mayores de 70 a 80 años: controversias y evidencia. Rev. Colomb Cardiol. 2019;26(4):211-7. http://doi.org/dg7p.
Nölker G, Mayer J, Boldt LH, Seidl K, VAN Driel V, Massa T, et al. Performance of an Implantable Cardiac Monitor to Detect Atrial Fibrillation: Results of the DETECT AF Study. J Cardiovasc Electrophysiol. 2016;27(12):1403-10. http://doi.org/f9f6gz.
Healey JS, Alings M, Ha A, Leong-Sit P, Birnie DH, De Graaf JJ, et al. Subclinical atrial fibrillation in older patients. Circulation. 2017;136(14):1276-83. http://doi.org/dg7q.
Ungar A, Sgobino P, Russo V, Vitale E, Sutton R, Melissano D, et al. Diagnosis of neurally mediated syncope at initial evaluation and with tilt table testing compared with that revealed by prolonged ECG monitoring. An analysis from the Third International Study on Syncope of Uncertain Etiology (ISSUE-3). Heart. 2013;99(24):1825-31. http://doi.org/dg7r.
Zungsontiporn N, Link MS. Newer technologies for detection of atrial fibrillation. BMJ. 2018;363:K3946. http://doi.org/dg7s.
Bhangu J, mcmahon CG, Hall P, Bennett K, Rice C, Crean P, et al. Long-term cardiac monitoring in older adults with unexplained falls and syncope. Heart. 2016;102(9):681-6. http://doi.org/f8jkvt.
Shanmugam N, Liew R. The implantable loop recorder-an important addition to the armentarium in the management of unexplained syncope. Ann Acad Med Singapore. 2012;41(3):115-24.
Sanna T, Diener HC, Passman RS, Di Lazzaro V, Bernstein RA, Morillo CA, et al. Cryptogenic Stroke and Underlying Atrial Fibrillation. N Engl J Med. 2014;370(26):2478-86. http://doi.org/trg.
Cuevas-Trisan R. Balance Problems and Fall Risks in the Elderly. Clin Geriatr Med. 2019;35(2):173-83. http://doi.org/dg7v.
Andersen LW, Holmberg MJ, Berg KM, Donnino MW, Granfeldt A. In-Hospital Cardiac Arrest: A review. JAMA. 2019;321(12):1200-10. http://doi.org/ggdh4h.
Armstrong VL, Lawson J, Kamper AM, Newton J, Kenny RA. The use of an implantable loop recorder in the investigation of unexplained syncope in older people. Age Ageing. 2003;32(2):185-8. http://doi.org/dq79t7.
Brignole M, Moya A, de Lange FJ, Deharo JC, Elliott PM, Fanciulli A, et al. 2018 ESC Guidelines for the diagnosis and management of syncope. Eur Heart J. 2018;39(21):1883-948. http://doi.org/gc8v9w.
Iriki Y, Oketani N, Ohishi M. The implantation of a loop recorder to detect the cause of pre-syncope in an 85-year-old man. Nihon Ronen Igakkai Zasshi. 2016;53(4):419-23. http://doi.org/dg7w.
Soteriades ES, Evans JC, Larson MG, Chen MH, Chen L, Benjamin EJ, et al. Incidence and prognosis of syncope. N Engl J Med. 2002;347(12):878-85. http://doi.org/c33rj6.
Gau JT, Barcikowski RS. Falls and supplementation of vitamin D and calcium. J Am Geriatr Soc. 2006;54(6):1020-1. http://doi.org/dfh5px.
Ryan DJ, Nick S, Colette SM, Roseanne K. Carotid sinus syndrome, should we pace? A multicentre, randomised control trial (Safepace 2). Heart. 2010;96(5):347-51. http://doi.org/cs9hcr.
Maggi R, Rafanelli M, Ceccofiglio A, Solari D, Brignole M, Ungar A. Additional diagnostic value of implantable loop recorder in patients with initial diagnosis of real or apparent transient loss of consciousness of uncertain origin. Europace. 2014;16(8):1226-30. http://doi.org/f6hb84.
Dimensions
PlumX
Visitas a la página del resumen del artículo
Descargas
Cómo citar
Licencia
Derechos de autor 2020 Case Reports

Esta obra está bajo una licencia internacional Creative Commons Atribución 4.0.
Los autores al someter sus manuscritos conservarán sus derechos de autor. La revista tiene el derecho del uso, reproducción, transmisión, distribución y publicación en cualquier forma o medio.
El Formulario de Divulgación Uniforme para posibles Conflictos de Interés y los oficios de cesión de derechos y de responsabilidad deben ser entregados junto con el original.
Aquellos autores/as que tengan publicaciones con esta revista, aceptan los términos siguientes:
Los autores/as conservarán sus derechos de autor y garantizarán a la revista el derecho de primera publicación de su obra, el cual estará simultáneamente sujeto a la Licencia de reconocimiento de Creative Commons 4.0 que permite a terceros compartir la obra siempre que se indique su autor y su primera publicación en esta revista.
Los autores/as podrán adoptar otros acuerdos de licencia no exclusiva de distribución de la versión de la obra publicada (p. ej.: depositarla en un archivo telemático institucional o publicarla en un volumen monográfico) siempre que se indique la publicación inicial en esta revista.
Se permite y recomienda a los autores/as difundir su obra a través de Internet (p. ej.: en archivos telemáticos institucionales o en su página web) antes y durante el proceso de envío, lo cual puede producir intercambios interesantes y aumentar las citas de la obra publicada. (Véase El efecto del acceso abierto).