Formulating a design for a screw-type shear connector in a composite section
Formulación para el diseño de conectores de cortante tipo tornillo en secciones compuestas
Keywords:
shear connector, push-out test, shear design formulation, composite section. (en)conectores de cortante, ensayos de corte directo, formulación de diseño, sección compuesta. (es)
Downloads
Screws-type shear connectors have been most used in Colombia during the last decade; however, an expression for their design in composite sections has only recently been presented (NSR10, paragraph F.2.9.8.2.2). This paper outlines shear design formulation development for screw connectors, analysing the influence of different composite section behaviour parameters. This research studied 18 composite section models using two 42MPa concrete slabs having different arrangements of 1/2", 5/8" or 3/4" diameter 1, 2 or 3 screw shear connectors and 0.08m, 0.12m or 0.14m spacing between connectors. Three specimens were tested by push-out for each model. The laboratory results using the methodology proposed by Ollgaard revealed connector diameter and spacing influence on the model’s behaviour. A design formulation for screws in composite sections is presented.
En Colombia, durante la última década, uno de los tipos de conectores de cortante más utilizados ha sido el de los tornillos, pero hasta ahora surge una formulación para su diseño en secciones compuestas, incluida en el numeral F.2.9.8.2.2 de NSR10. En este artículo se muestra la deducción de dicha formulación de diseño para conectores tipo tornillo, analizando la influencia de diferentes parámetros en el comportamiento de las secciones compuestas cuando se emplean tornillos como conectores de cortante. En esta investigación se estudiaron 18 modelos de sección compuesta fabricados con perfiles de alma llena y losas de concreto de 42 MPa, en las cuales se manejaron configuraciones de 1, 2 o 3 conectores de cortante tipo tornillo con diámetros 1/2", 5/8" o 3/4"; y para separaciones de 0,08 m, 0,12 m o 0,14 m; por cada modelo se ensayaron tres probetas ante solicitación de corte directo (push-out). De acuerdo con los resultados experimentales obtenidos, se efectuó el análisis por medio de la metodología planteada por Ollgaard, donde se evaluó la incidencia del diámetro y la separación de los conectores en el comportamiento de los modelos, y finalmente se plantea la formulación para el diseño de los conectores tipo tornillo en secciones compuestas.
References
American Institute of Steel Construction., Specification for Structural Steel Buildings, Chicago, 2005.
Asociación de Ingeniería Sísmica., NSR-98, Tomo 3, Bogotá, 1998, pp. F38-F39.
Asociación de Ingeniería Sísmica., NSR-10, Título F, Bogotá, 2010, pp. F102-F103.
Burnet, M., Oehlers D., Fracture of Mechanical Shear Connectors in Composite Beams MECH., STRUCT & MACH, 2001, pp. 1-41.
García, A., Molina, M., Comportamiento de vigas de sección compuesta con perfiles de acero laminado y losa de concreto empleando conectores de cortante tipo tornillo grado dos (2)., Ingeniería e Investigación, 2008, pp. 11-21.
Hurtado, X., Molina, M., Linero, D., Comportamiento de conectores de cortante tipo tornillo de resistencia grado dos para un sistema de sección compuesta., Ingeniería e Investigación, 2008, pp. 4-14.
Hurtado, X., Comportamiento de conectores tipo tornillo grado dos para un sistema de sección compuesta con concreto de 21MPa ante solicitación de corte directo., Tesis de Magister en Ingeniería- Estructuras, Universidad Nacional de Colombia, 2007.
Nie, J., Caí, C., Steel-Concrete Composite Beams Considering Shear Slip Effects., Journal of Structural Engineering, Vol. 129, 2008, pp. 4-14.
Ollgaard, J., Slutter, R., Fisher, J., Shear strength of stud connectors in lightweight and normal-weight concrete., Engineering Journal, AISC, 1971, pp. 55-64.
Viest, I., Investigation of stud shear connectors for composite concrete and steel t-beams., Journal of the American Concrete Institute, ACI, 1956, pp. 875-890.
License
Copyright (c) 2011 Maritzabel Molina Herrera, Xavier Fernando Hurtado Amézquita

This work is licensed under a Creative Commons Attribution 4.0 International License.
The authors or holders of the copyright for each article hereby confer exclusive, limited and free authorization on the Universidad Nacional de Colombia's journal Ingeniería e Investigación concerning the aforementioned article which, once it has been evaluated and approved, will be submitted for publication, in line with the following items:
1. The version which has been corrected according to the evaluators' suggestions will be remitted and it will be made clear whether the aforementioned article is an unedited document regarding which the rights to be authorized are held and total responsibility will be assumed by the authors for the content of the work being submitted to Ingeniería e Investigación, the Universidad Nacional de Colombia and third-parties;
2. The authorization conferred on the journal will come into force from the date on which it is included in the respective volume and issue of Ingeniería e Investigación in the Open Journal Systems and on the journal's main page (https://revistas.unal.edu.co/index.php/ingeinv), as well as in different databases and indices in which the publication is indexed;
3. The authors authorize the Universidad Nacional de Colombia's journal Ingeniería e Investigación to publish the document in whatever required format (printed, digital, electronic or whatsoever known or yet to be discovered form) and authorize Ingeniería e Investigación to include the work in any indices and/or search engines deemed necessary for promoting its diffusion;
4. The authors accept that such authorization is given free of charge and they, therefore, waive any right to receive remuneration from the publication, distribution, public communication and any use whatsoever referred to in the terms of this authorization.