Publicado

2018-01-01

Ensayo de migración global en empaques para alimentos: evaluación de patrones internos alternativos

Overall migration test in food packaging: Evaluation of alternative internal standards

Ensaio de migração global em embalagens de alimentos: avaliação de padrões internos alternativos

DOI:

https://doi.org/10.15446/rev.colomb.quim.v47n1.63859

Palabras clave:

empaques plásticos, Cromatografía de gases, ésteres metílicos de ácidos grasos (FAMEs) (es)
plastic packaging, gas chromatography, fatty acid methyl esters (FAMEs) (en)

Autores/as

  • Edgar Andres Avendaño Florez Universidad Nacional de Colombia Facultad de Ciencias Departamento de Química Bogotá-Colombia
  • Elianna Castillo Serna Universidad Nacional de Colombia Facultad de Ciencias Departamento de Química Bogotá-Colombia
  • Diana Cristina Sinuco León Universidad Nacional de Colombia Facultad de Ciencias Departamento de Química Bogotá-Colombia https://orcid.org/0000-0002-1782-0676

En el ensayo de migración global para empaques plásticos destinados a alimentos grasos se emplea triheptadecanoato de glicerilo (GTM) como patrón interno para la cuantificación de los ésteres metílicos de ácidos grasos (FAMEs) por cromatografía de gases. En este trabajo se evaluaron 3-fenil propanoato de etilo (EFP) y ácido tetradecanóico (AM) como patrones internos alternativos. El uso de AM presentó comportamiento lineal (r > 0,99 y %Sb < 5%), buena precisión intermedia (HORRATr = 0,9) y exactitud (%R = 100,6%). En contraste, la evaluación del EFP, demostró que este no es un patrón interno adecuado para la cuantificación de FAMEs. De otra parte, se evaluó estadísticamente que no hay diferencias significativas en el cálculo de la migración global a partir de FAMEs cuantificados usando como patrón interno GTM o AM, mientras que el uso de EFP sí presenta diferencias significativas.

In the global migration test for plastic packaging intended for fatty foods, glyceryl triheptadecanoate (GTM) is used as the internal standard for the quantification of fatty acid methyl esters (FAMEs) by gas chromatography. In this work, ethyl 3-phenyl propanoate (EFP) and tetradecanoic acid (AM) were evaluated as alternative internal standards. The use of (AM) presented linear behavior (r > 0.99 and %Sb < 5%), good intermediate precision (HORRATr = 0.9), and accuracy (%R = 100.6%). In contrast, the evaluation of (EFP) demonstrated that this is not an adequate internal standard for the quantification of FAMEs. In addition, it was statistically evaluated that there are no significant differences in the calculation of the global migration from FAMEs quantified using GTM or AM as internal standards, but the use of EFP presents significant differences.
No ensaio de migração global para embalagens plásticas destinadas aos alimentos gordurosos, é usado o triheptadecanoato de glicerina (GTM) como padrão interno para a quantificação dos ésteres metílicos de ácidos gordos (FAMEs) mediante cromatografia em fase gasosa. Neste papel foram avaliados 3-fenil propanoato de etilo (EFP) e ácido tetradecanóico (AM) como padrões internos alternativos. O (AM) apresentou comportamento linear (r > 0,99 e %Sb < 5%), boa precisão intermédia (HORRATr = 0,9) e precisão (%R = 100,6%). Em contraste, a avaliação do (EFP), mostrou que este não é um padrão interno adequado para a quantificação de FAMEs. Por outro lado, uma avaliação estatística indicou que não há diferenças significativas no cálculo da migração global de FAMEs quantificadas utilizando como padrão interno GTM ou AM, em contrapartida o uso do EFP apresenta diferenças significativas.

Referencias

ICONTEC, NTC 5022-1. Materiales y artículos en contacto con productos Alimenticios. Plásticos. Parte 1: Elección de condiciones y métodos de ensayo para la migración global, 2010.

EUR-Lex - 32014R0865. Reglamento (UE) No 10/2011 de la Comisión, de 14 de enero de 2011, sobre materiales y objetos plásticos destinados a entrar en contacto con alimentos. OJ 238 982014 P 1–2.

MERCOSUR, Resolución GMC 056/1992, 1992.

George, S.C.; Thomas, S. Transport phenomena through polymeric systems. Prog. Polym. Sci. 2001, 26, 985–1017. DOI:10.1016/S0079-6700(00)00036-8.

Siracusa, V. Food Packaging Permeability Behaviour: A Report. Int. J. Polym. Sci. 2012, e302029. DOI: http://dx.doi.org/10.1155/2012/302029.

Elskens M.; Vloeberghs D.; Van Elsen L.; Baeyens W.; Goeyens L. Multiple Testing Of Food Contact Materials: A Predictive Algorithm For Assessing The Global Migration From Silicone Moulds. Talanta. 2012, 99, 161-1666. DOI: http://dx.doi.org/10.1016/j.talanta.2012.05.034.

Atek, D.; Belhaneche-Bensemra, N., FTIR investigation of the specific migration of additives from rigid poly(vinyl chloride). Eur. Polym. J. 2005, 41, 707-714, DOI: http://dx.doi.org/10.1016/j.eurpolymj.2004.10.043.

Song H, Li B, Lin QB, Wu HJ, Chen Y. Migration of silver from nanosilver–polyethylene composite packaging into food simulants. Food Addit. Contam., Part A. 2011, 28, 1758-62. DOI: http://dx.doi.org/10.1080/19440049.2011.603705.

Welle F, Franz R. Migration of antimony from PET bottles into beverages: determination of the activation energy of diffusion and migration modelling compared with literature data. Food Addit. Contam., Part A. 2011, 28, 115-126. DOI: http://dx.doi.org/10.1080/19440049.2010.530296.

Welle F, Franz R. Diffusion coefficients and activation energies of diffusion of low molecular weight migrants in Poly(ethylene terephthalate) bottles. Polym. Test. 2012, 31, 93–101. DOI: http://dx.doi.org/10.1016/j.polymertesting.2011.09.011.

Grob, K. The future of simulants in compliance testing regarding the migration from food contact materials into food. Food Control. 2008, 19, 263–268. DOI: http://dx.doi.org/10.1016/j.foodcont.2007.04.001.

BSI, British Standards Institute. I. Materials and articles in contact with foodstuffs. Plastics. Guide to the selection of conditions and test methods for overall migration. BSI: London. UK, 2002; pp. 27-29.

Aguirre, L.; Pérez, J.; Pujol, M;. Validación de métodos analíticos. Publicaciones Asociación Española de Farmacéuticos de la Industria: Barcelona, España, 2001; pp. 39-134.

Arvanitoyannis, I.S.; Bosnea, L. Migration of substances from food packaging materials to foods. Crit. Rev. Food Sci. Nutr. 2004, 44, 63–76. DOI: http://dx.doi.org/10.1080/10408690490424621.

IOFI Working Group on Methods of Analysis, Guidelines for the quantitative gas chromatography of volatile flavouring substances, from the Working Group on Methods of Analysis of the International Organization of the Flavor Industry (IOFI). Flavor Fragr. J. 2011, 26, 297-299. DOI: http://dx.doi.org/10.1002/ffj.2061.

Juárez, M.; Polvillo, O.; Contò, M.; Ficco, A.; Ballico, S.; Failla, S.. Comparison of four extraction/methylation analytical methods to measure fatty acid composition by gas chromatography in meat. J. Chromatogr. A 2008, 1190, 327–332. DOI: http://dx.doi.org/10.1016/j.chroma.2008.03.004.

Salimon, J.; Omar, T.; Salih, N. Comparison of two derivatization methods for the analysis of fatty acids and trans fatty acids in bakery products using gas chromatography. Sci. World J. 2014, ID906407. DOI: http://dx.doi.org/10.1155/2014/906407.

Yurchenko, S.; Sats, A.; Poikalainen, V.; Karus, A. Method for determination of fatty acids in bovine colostrum using GC-FID. Food Chem. 2016, 212, 117–122. DOI: http://dx.doi.org/10.1016/j.foodchem.2016.05.103.

Bratinova, S.; Raffael, B.; Simoneau, C. Guidelines for performance criteria and validation procedures of analytical methods used in controls of food contact materials. Joint Research Centre, Scientific and Technical Reports: Italia, 2009; pp. 15-56.

Visentainer, J.; Claus, T.; Santos Junior, O.; Chiavelli, L.; Maruyama, S., Analytical Aspects of the Flame Ionization Detection in Comparison with Mass Spectrometry with Emphasis on Fatty Acids and Their Esters. In: Advances in Gas Chromatography. Guo, X. Ed.; InTech. 2014. DOI: http://dx.doi.org/10.5772/57016

Horwitz, W.; Kamps, L.R.; Boyer, K.W., Quality assurance in the analysis of foods and trace constituents. J. Assoc. Off. Anal. Chem. 1980, 63, 1344–1354.

AOAC International. Appendix F: Guidelines for Standard Method Performance Requirements. In: AOAC Official Methods of Analysis. AOAC International: Maryland, USA, 2012; pp. 1–17.

Ribani, M.; Collins, C.H.; Bottoli, C.B., Validation of chromatographic methods: evaluation of detection and quantification limits in the determination of impurities in omeprazole. J. Chromatogr. A, 2007, 1156, 201–205. DOI: http://dx.doi.org/10.1016/j.chroma.2006.12.080.

Dimensions

PlumX

Visitas a la página del resumen del artículo

2783

Descargas

Los datos de descarga aún no están disponibles.

Cómo citar

[1]
E. A. Avendaño Florez, E. Castillo Serna, y D. C. Sinuco León, «Ensayo de migración global en empaques para alimentos: evaluación de patrones internos alternativos», Rev. Colomb. Quim., vol. 47, n.º 1, pp. 34–40, ene. 2018, doi: 10.15446/rev.colomb.quim.v47n1.63859.